簡要描述:Illumina 簇生成和測序試劑 MS-102-3003上海易匯生物科技有限公司于17年正式銷售Illumina公司基因芯片、二代測序NGS測序儀及相關(guān)測序試劑盒等產(chǎn)品Illumina/TruSeq Amplicon - Cancer Panel (96 samples)/FC-130-1008/1 Ea
相關(guān)文章
Related Articles詳細(xì)介紹
品牌 | illumina/美國因美納 | 貨號 | Illumina 簇生成和測序試劑 MS-102-3003 |
---|---|---|---|
規(guī)格 | 1 kit | 供貨周期 | 兩周 |
主要用途 | 小型全基因組測序 組合試劑 試劑盒 | 應(yīng)用領(lǐng)域 | 醫(yī)療衛(wèi)生,化工,生物產(chǎn)業(yè),制藥 |
Illumina 簇生成和測序試劑 MS-102-3003
Illumina公司,致力于新一代測序和芯片技術(shù)的生產(chǎn)與開發(fā),提供產(chǎn)品與應(yīng)用資訊
Illumina公司創(chuàng)立于1998年4月,是遺傳變異和生物學(xué)功能分析領(lǐng)域的優(yōu)秀的產(chǎn)品、技術(shù)和服務(wù)供應(yīng)商。通過幫助客戶加快實(shí)現(xiàn)生物信息的采集、分析和應(yīng)用,來改善人類健康。
Sequencing Kits/ Microarray Kits/Informatics Products/ Clinical Research Products/In Vitro Diagnostic/ Products/Molecular Biology Reagents/ Accessory Products
上海易匯生物科技有限公司于17年正式銷售Illumina公司基因芯片、二代測序NGS測序儀及相關(guān)測序試劑盒等產(chǎn)品
咨詢illumina MiSeq測序試劑盒等產(chǎn)品歡迎您致電 上海易匯生物科技有限公司:1850 1609 238張經(jīng)理
Illumina/TruSeq DNA Methylation Kit (12 reactions)/EGMK81312/1 Ea EGMK81312 Illumina 產(chǎn)品編號: EGMK81312美 元 價: $1009.00會 員 價: 待定品 牌: Illumina產(chǎn) 地: 美國公 司: Illumina, Inc.產(chǎn)品分類: 分子類>二代測序>DNA文庫制備試劑盒公司分類: Library Preparation Kits "Product Highlights:
Unlock small samples (50–100 ng DNA input)
CpG, CHH, & CHG regions included for comprehensive, whole-genome results
Fast protocol – five-hour method
Capture full sample diversity
Sequence the entire sample–no loss of information
The process of bisulfite treatment denatures genomic DNA into single stranded DNA. TruSeq DNA Methylation converts single stranded DNA into an Illumina sequencing library. All ssDNA fragments are captured into an Illumina sequencing library, therefore eliminating the loss of diversity associated with other methods.
Supported analysis in the cloud
TruSeq DNA Methylation libraries can be aligned to the human genome and compared for differential methylation with Illumina BaseSpace Apps MethylSeq and MethylKit. These applications are fully supported and were developed specifically for TruSeq DNA Methylation library preparation.
Example data sets for TruSeq DNA Methylation libraries, also available in BaseSpace Sequence Hub Data Central (use the “Methyl Seq” category filter), demonstrate unparalleled quality and seamless analysis.
Deep coverage of critical genomic regions
Depth of coverage is enhanced in genomic areas with BIOLOGical utility. TruSeq DNA Methylation captures full sample diversity of critical areas, including:
Coding region start and end for exons from the canonical transcript of protein coding genes for genes known to be involved in cancer, taken from SOMA and CRUK panels (as well as literature-derived cancer genes)
Genes defined by the American College of Medical Genetics as being medically relevant (ACMG genes)
Exonic coding regions from Ensemble 70
List of 100 promoters defined by the Broad Institute as being of high interest and difficult to sequence"
"Illumina/TruSeq Small RNA Set C MiniSeq Kit (1 library prep and 2 MiniSeq reagents)/20005615/1 Ea
" 20005615 Illumina 產(chǎn)品編號: 20005615美 元 價: $3200.00會 員 價: 待定品 牌: Illumina產(chǎn) 地: 美國公 司: Illumina, Inc.產(chǎn)品分類: 分子類>二代測序>DNA文庫制備試劑盒公司分類: Library Preparation Kits "Product Highlights:
TruSeq Small RNA Library Preparation Kits provide reagents to generate small RNA libraries directly from total RNA. MicroRNAs (miRNAs) generated by Dicer processing are efficiently targeted by the included modified adapters.
These kits enable multiplexed sequencing with the introduction of 48 unique indexes, allowing miRNA and small RNA discovery and profiling throughput to match the unparalleled output of Illumina sequencing. Indexes are added in a universal amplification reaction, greatly reducing ligation bias and ensuring accurate measurement of miRNA expression.
Workflow improvements enable streamlined sample preparation, allowing economical studies covering all small RNA transcripts in any species. CompatIBLe applications include finding novel miRNAs, characterizing variation such as isomers with single-base resolution, and analyzing differential expression without prior assumptions.
TruSeq Small RNA Sample Datasets
The Human Brain Reference RNA (HBRR) and Universal Human Reference RNA (UHRR) samples were prepared using the TruSeq Small RNA Library Prep Kit. These libraries were sequenced on the MiniSeq System using the MiniSeq High Output Reagent Kit at a 1 x 36 bp read length configuration. The total yield was 0.91 Gb with 97% of bases at or above Q30.
Browse the Data In BaseSpace Sequence Hub:
View Run (primary analysis and metrics)
View Project (secondary analysis with BaseSpace Apps)"
"Illumina/MiSeq FGx Reagent Kit/TG-143-1001/1 Ea
" TG-143-1001 Illumina 產(chǎn)品編號: TG-143-1001美 元 價: $1400.00會 員 價: 待定品 牌: Illumina產(chǎn) 地: 美國公 司: Illumina, Inc.產(chǎn)品分類: 分子類>二代測序>簇生成和測序試劑公司分類: Cluster Generation & Sequencing Reagents "Product Highlights:
This sequencing kit for forensic genomics applications is based on the MiSeq Reagent Kit v3, which enables the highest output of all MiSeq kits. This kit allows forensic genomics laboratories to:
Simultaneously analyze a dense set of forensically relevant Markers at low, medium, or high sample throughput
Extend read lengths
Increase the number of reads to unlock new applications
The MiSeq FGx Reagent Kit uses pre-filled, ready-to-use reagent cartridges, and offers the improved v3 chemistry to increase cluster density and read length as well as improve quality.
MiSeq FGx Reagent Kit components are RFID-encoded and interact intelligently with the MiSeq FGx System to validate compatibility with forensic genomic applications.
Specifications:
Maximum Output 15 Gb
Maximum Reads per Run 14 million
Reagent Type Paired-End Sequencing,Cluster Generation,Sequencing by Synthesis
Technology Sequencing
System Compatibility MiSeq FGx"
Illumina/TruSeq Targeted RNA Index Kit D (96 indexes, 384 samples)/RT-402-1004/1 Ea RT-402-1004 Illumina 產(chǎn)品編號: RT-402-1004美 元 價: $1019.00會 員 價: 待定品 牌: Illumina產(chǎn) 地: 美國公 司: Illumina, Inc.產(chǎn)品分類: 分子類>二代測序>DNA文庫制備試劑盒公司分類: Library Preparation Kits "Product Highlights:
TruSeq Targeted RNA Expression Kits enable highly customizable mid- to high-plex gene expression profiling studies.
You can define panels of 12-1,000 assays to target individual exons, isoforms, splice junctions, coding SNPS (cSNPs), gene fusions, and non-coding RNA transcripts, plus multiplex up to 384 samples. Generate the data equivalent of up to 25,000 individual RT-PCR assays in a single run.*
Assays include convenient online panel design and ordering, a rapid and simple workflow starting with as little as 50 ng of RNA, and automated, on-instrument data analysis.
Types of Study Designs
Custom panels—select up to 1000 targets from a database of over 400,000 predesigned assays.
Add-on (supplemental) content—add a second oligo pool of up to 1000 targets to a previously designed TruSeq Targeted RNA Expression custom panel.
Start a Custom Project
Order custom panels using DesignStudio, a free, user-friendly, web-based tool. Simply select the assays you need and add them to your order, with no design time.
Log in to DesignStudio
Browse TruSeq Targeted RNA Sample Data
Human Brain Reference RNA (HBRR), Universal Human Reference RNA (UHRR), and human liver RNA samples were prepared using the TruSeq Targeted RNA Expression Kit.
These libraries were sequenced on the MiniSeq System using the MiniSeq High Output Reagent Kit at a 1 x 51 bp read length configuration. The total yield was 2.04 Gb with 96.5% of bases at or above Q30.
Note that access to this data requires a BaseSpace Sequence Hub login.
Register for BaseSpace Sequence Hub
View TruSeq Targeted RNA Project Data
(secondary analysis with BaseSpace Apps)
*Refers to instruments with catalog number SY-410-1001 and upgrade, or catalog number SY-410-1003
Specifications:
Assay Time 1 day
Hands-On Time 4 hours
Input Quantity 50 ng RNA,50 ng high-quality total RNA,≥ 200 ng FFPE total RNA; Recommended quantity may vary with expression level, target plexity, and sample quality
Content Specifications Choose from 400,000+ pre-designed targeted RNA-Seq assays. Or add content to a fixed panel or previously designed custom panel.
Multiplexing Up to 384 samples per sequencing run
Mechanism of Action Amplification
Method Targeted RNA Sequencing
Variant Class Single Nucleotide Polymorphisms (SNPs),Gene Fusions,Transcript Variants
Specialized Sample Types FFPE
"
Illumina/TruSeq Small RNA Set B MiniSeq Kit (1 library prep and 2 MiniSeq reagents)/20005614/1 Ea 20005614 Illumina 產(chǎn)品編號: 20005614美 元 價: $3200.00會 員 價: 待定品 牌: Illumina產(chǎn) 地: 美國公 司: Illumina, Inc.產(chǎn)品分類: 分子類>二代測序>DNA文庫制備試劑盒公司分類: Library Preparation Kits "Product Highlights:
TruSeq Small RNA Library Preparation Kits provide reagents to generate small RNA libraries directly from total RNA. MicroRNAs (miRNAs) generated by Dicer processing are efficiently targeted by the included modified adapters.
These kits enable multiplexed sequencing with the introduction of 48 unique indexes, allowing miRNA and small RNA discovery and profiling throughput to match the unparalleled output of Illumina sequencing. Indexes are added in a universal amplification reaction, greatly reducing ligation bias and ensuring accurate measurement of miRNA expression.
Workflow improvements enable streamlined sample preparation, allowing economical studies covering all small RNA transcripts in any species. CompatIBLe applications include finding novel miRNAs, characterizing variation such as isomers with single-base resolution, and analyzing differential expression without prior assumptions.
TruSeq Small RNA Sample Datasets
The Human Brain Reference RNA (HBRR) and Universal Human Reference RNA (UHRR) samples were prepared using the TruSeq Small RNA Library Prep Kit. These libraries were sequenced on the MiniSeq System using the MiniSeq High Output Reagent Kit at a 1 x 36 bp read length configuration. The total yield was 0.91 Gb with 97% of bases at or above Q30.
Browse the Data In BaseSpace Sequence Hub:
View Run (primary analysis and metrics)
View Project (secondary analysis with BaseSpace Apps)
Specifications:
Assay Time ~10.5 hours
Hands-On Time ~30 minutes
Input Quantity 25 to 100 ng total RNA from species with polyA tails
Content Specifications Captures the coding transcriptome with strand information
Mechanism of Action Oligo-dT beads capture polyA tails
Multiplexing Up to 24-plex pooling with additional NeoPrep runs
Sample Throughput Up to 16 samples per NeoPrep library card
Species Category Drosophila,Any Species,Mouse,Zebrafish,Human,Rat,Plant,Nematode
System Compatibility MiSeq,NextSeq 550,MiniSeq,NextSeq 500
Specialized Sample Types FFPE,Low Input
Technology Sequencing
Automation CapABIlity Liquid Handling Robots
Variant Class Novel Transcripts,Transcript Variants
Method miRNA and Small RNA Sequencing"
Illumina/TruSeq Small RNA Library Prep Kit -Set B (24 rxns) (Set B: indexes 13-24)/RS-200-0024/1 Ea RS-200-0024 Illumina 產(chǎn)品編號: RS-200-0024美 元 價: $2450.00會 員 價: 待定品 牌: Illumina產(chǎn) 地: 美國公 司: Illumina, Inc.產(chǎn)品分類: 分子類>二代測序>DNA文庫制備試劑盒公司分類: Library Preparation Kits "Product Highlights:
TruSeq Small RNA Library Preparation Kits provide reagents to generate small RNA libraries directly from total RNA. MicroRNAs (miRNAs) generated by Dicer processing are efficiently targeted by the included modified adapters.
These kits enable multiplexed sequencing with the introduction of 48 unique indexes, allowing miRNA and small RNA discovery and profiling throughput to match the unparalleled output of Illumina sequencing. Indexes are added in a universal amplification reaction, greatly reducing ligation bias and ensuring accurate measurement of miRNA expression.
Workflow improvements enable streamlined sample preparation, allowing economical studies covering all small RNA transcripts in any species. CompatIBLe applications include finding novel miRNAs, characterizing variation such as isomers with single-base resolution, and analyzing differential expression without prior assumptions.
TruSeq Small RNA Sample Datasets
The Human Brain Reference RNA (HBRR) and Universal Human Reference RNA (UHRR) samples were prepared using the TruSeq Small RNA Library Prep Kit. These libraries were sequenced on the MiniSeq System using the MiniSeq High Output Reagent Kit at a 1 x 36 bp read length configuration. The total yield was 0.91 Gb with 97% of bases at or above Q30.
Browse the Data In BaseSpace Sequence Hub:
View Run (primary analysis and metrics)
View Project (secondary analysis with BaseSpace Apps)
Specifications:
Assay Time ~10.5 hours
Hands-On Time ~30 minutes
Input Quantity 25 to 100 ng total RNA from species with polyA tails
Content Specifications Captures the coding transcriptome with strand information
Mechanism of Action Oligo-dT beads capture polyA tails
Multiplexing Up to 24-plex pooling with additional NeoPrep runs
Sample Throughput Up to 16 samples per NeoPrep library card
Species Category Drosophila,Any Species,Mouse,Zebrafish,Human,Rat,Plant,Nematode
System Compatibility MiSeq,NextSeq 550,MiniSeq,NextSeq 500
Specialized Sample Types FFPE,Low Input
Technology Sequencing
Automation CapABIlity Liquid Handling Robots
Variant Class Novel Transcripts,Transcript Variants
Method miRNA and Small RNA Sequencing"
Illumina/TruSeq Stranded mRNA Library Prep Kit for NeoPrep (16 samples, 24 indexes)/NP-202-1001/1 Ea NP-202-1001 Illumina 產(chǎn)品編號: NP-202-1001美 元 價: $880.00會 員 價: 待定品 牌: Illumina產(chǎn) 地: 美國公 司: Illumina, Inc.產(chǎn)品分類: 分子類>二代測序>DNA文庫制備試劑盒公司分類: Library Preparation Kits "Product Highlights:
The TruSeq Stranded mRNA Library Prep Kit for NeoPrep offers a streamlined, cost-efficient, and scalable solution for coding transcriptome analysis. It enables robust interrogation of both standard and low-quality samples.
Simplified and seamless workflow solution – Generate libraries with minimal hands-on time
Unparalleled performance and reproducibility – Interrogate gene expression with TruSeq Stranded mRNA coverage and quality, and reduced user variABIlity
Low input requirement – Begin library prep with as little as 25 ng total RNA
Precise and Accurate
Get precise measurement of mRNA strand orientation for detection of antisense transcription, enhanced transcript annotation, and increased alignment efficiency. High coverage uniformity enhances the discovery of features such as alternative transcripts, gene fusions, and allele-specific expression.
Cost-Efficient
Stranded information identifies from which of the 2 DNA strands a given RNA transcript was derived. This information provides increased confidence in transcript annotation, particularly for nonhuman samples. Identifying strand origin increases the percentage of reads that align, reducing sequencing costs per sample.
NeoPrep System enhances TruSeq Stranded mRNA performance
The NeoPrep System enhances TruSeq Stranded mRNA performance by providing high-quality reproducIBLe results, even with low input amounts of RNA. Digital microfluidics technology precisely manipulates droplets that perform the library prep workflow, within the tightly controlled environment of the NeoPrep library card.
A simple, intuitive workflow delivers 16 libraries, eliminating most manual steps, and reducing hands-on time from ~4.5 hours to just 30 minutes. In addition, digital microfluidics requires less RNA input, enabling excellent performance from as little as 25 ng of total RNA.
Specifications:
Assay Time ~10.5 hours
Hands-On Time ~30 minutes
Input Quantity 25 to 100 ng total RNA from species with polyA tails
Content Specifications Captures the coding transcriptome with strand information
Mechanism of Action Oligo-dT beads capture polyA tails
Multiplexing Up to 24-plex pooling with additional NeoPrep runs
Sample Throughput Up to 16 samples per NeoPrep library card
System Compatibility Genome Analyzer IIx,HiSeq 2000,MiSeq,NextSeq 550,HiSeq 3000,HiSeq 1000,NeoPrep,HiSeq 1500,NextSeq 500,HiSeq 2500,HiSeq 4000
Species Category Other,Mammalian,Bovine,Mouse,Human,Rat
Variant Class Single Nucleotide Polymorphisms (SNPs),Gene Fusions,Novel Transcripts,Transcript Variants
Technology Sequencing
Method mRNA Sequencing
Automation CapABIlity NeoPrep Digital Microfluidics"
Illumina/TruSeq Targeted RNA Index Kit A (96 indexes, 384 samples)/RT-402-1001/1 Ea RT-402-1001 Illumina 產(chǎn)品編號: RT-402-1001美 元 價: $1019.00會 員 價: 待定品 牌: Illumina產(chǎn) 地: 美國公 司: Illumina, Inc.產(chǎn)品分類: 分子類>二代測序>DNA文庫制備試劑盒公司分類: Library Preparation Kits "Product Highlights:
TruSeq Targeted RNA Expression Kits enable highly customizable mid- to high-plex gene expression profiling studies.
You can define panels of 12-1,000 assays to target individual exons, isoforms, splice junctions, coding SNPS (cSNPs), gene fusions, and non-coding RNA transcripts, plus multiplex up to 384 samples. Generate the data equivalent of up to 25,000 individual RT-PCR assays in a single run.*
Assays include convenient online panel design and ordering, a rapid and simple workflow starting with as little as 50 ng of RNA, and automated, on-instrument data analysis.
Types of Study Designs
Custom panels—select up to 1000 targets from a database of over 400,000 predesigned assays.
Add-on (supplemental) content—add a second oligo pool of up to 1000 targets to a previously designed TruSeq Targeted RNA Expression custom panel.
Start a Custom Project
Order custom panels using DesignStudio, a free, user-friendly, web-based tool. Simply select the assays you need and add them to your order, with no design time.
Log in to DesignStudio
Browse TruSeq Targeted RNA Sample Data
Human Brain Reference RNA (HBRR), Universal Human Reference RNA (UHRR), and human liver RNA samples were prepared using the TruSeq Targeted RNA Expression Kit.
These libraries were sequenced on the MiniSeq System using the MiniSeq High Output Reagent Kit at a 1 x 51 bp read length configuration. The total yield was 2.04 Gb with 96.5% of bases at or above Q30.
Note that access to this data requires a BaseSpace Sequence Hub login.
Register for BaseSpace Sequence Hub
View TruSeq Targeted RNA Project Data
(secondary analysis with BaseSpace Apps)
*Refers to instruments with catalog number SY-410-1001 and upgrade, or catalog number SY-410-1003
Specifications:
Assay Time 1 day
Hands-On Time 4 hours
Input Quantity 50 ng RNA,50 ng high-quality total RNA,≥ 200 ng FFPE total RNA; Recommended quantity may vary with expression level, target plexity, and sample quality
Content Specifications Choose from 400,000+ pre-designed targeted RNA-Seq assays. Or add content to a fixed panel or previously designed custom panel.
Multiplexing Up to 384 samples per sequencing run
Mechanism of Action Amplification
Method Targeted RNA Sequencing
Variant Class Single Nucleotide Polymorphisms (SNPs),Gene Fusions,Transcript Variants
Specialized Sample Types FFPE
"
Illumina/TruSeq Small RNA Library Prep Kit -Set C (24 rxns) (Set C: indexes 25-36)/RS-200-0036/1 Ea RS-200-0036 Illumina 產(chǎn)品編號: RS-200-0036美 元 價: $2450.00會 員 價: 待定品 牌: Illumina產(chǎn) 地: 美國公 司: Illumina, Inc.產(chǎn)品分類: 分子類>二代測序>DNA文庫制備試劑盒公司分類: Library Preparation Kits "Product Highlights:
TruSeq Small RNA Library Preparation Kits provide reagents to generate small RNA libraries directly from total RNA. MicroRNAs (miRNAs) generated by Dicer processing are efficiently targeted by the included modified adapters.
These kits enable multiplexed sequencing with the introduction of 48 unique indexes, allowing miRNA and small RNA discovery and profiling throughput to match the unparalleled output of Illumina sequencing. Indexes are added in a universal amplification reaction, greatly reducing ligation bias and ensuring accurate measurement of miRNA expression.
Workflow improvements enable streamlined sample preparation, allowing economical studies covering all small RNA transcripts in any species. CompatIBLe applications include finding novel miRNAs, characterizing variation such as isomers with single-base resolution, and analyzing differential expression without prior assumptions.
TruSeq Small RNA Sample Datasets
The Human Brain Reference RNA (HBRR) and Universal Human Reference RNA (UHRR) samples were prepared using the TruSeq Small RNA Library Prep Kit. These libraries were sequenced on the MiniSeq System using the MiniSeq High Output Reagent Kit at a 1 x 36 bp read length configuration. The total yield was 0.91 Gb with 97% of bases at or above Q30.
Browse the Data In BaseSpace Sequence Hub:
View Run (primary analysis and metrics)
View Project (secondary analysis with BaseSpace Apps)
Specifications:
Assay Time ~10.5 hours
Hands-On Time ~30 minutes
Input Quantity 25 to 100 ng total RNA from species with polyA tails
Content Specifications Captures the coding transcriptome with strand information
Mechanism of Action Oligo-dT beads capture polyA tails
Multiplexing Up to 24-plex pooling with additional NeoPrep runs
Sample Throughput Up to 16 samples per NeoPrep library card
Species Category Drosophila,Any Species,Mouse,Zebrafish,Human,Rat,Plant,Nematode
System Compatibility MiSeq,NextSeq 550,MiniSeq,NextSeq 500
Specialized Sample Types FFPE,Low Input
Technology Sequencing
Automation CapABIlity Liquid Handling Robots
Variant Class Novel Transcripts,Transcript Variants
Method miRNA and Small RNA Sequencing"
Illumina/TruSeq Small RNA Library Prep Kit -Set A (24 rxns) (Set A: indexes 1-12)/RS-200-0012/1 Ea RS-200-0012 Illumina 產(chǎn)品編號: RS-200-0012美 元 價: $2450.00會 員 價: 待定品 牌: Illumina產(chǎn) 地: 美國公 司: Illumina, Inc.產(chǎn)品分類: 分子類>二代測序>DNA文庫制備試劑盒公司分類: Library Preparation Kits "Product Highlights:
TruSeq Small RNA Library Preparation Kits provide reagents to generate small RNA libraries directly from total RNA. MicroRNAs (miRNAs) generated by Dicer processing are efficiently targeted by the included modified adapters.
These kits enable multiplexed sequencing with the introduction of 48 unique indexes, allowing miRNA and small RNA discovery and profiling throughput to match the unparalleled output of Illumina sequencing. Indexes are added in a universal amplification reaction, greatly reducing ligation bias and ensuring accurate measurement of miRNA expression.
Workflow improvements enable streamlined sample preparation, allowing economical studies covering all small RNA transcripts in any species. CompatIBLe applications include finding novel miRNAs, characterizing variation such as isomers with single-base resolution, and analyzing differential expression without prior assumptions.
TruSeq Small RNA Sample Datasets
The Human Brain Reference RNA (HBRR) and Universal Human Reference RNA (UHRR) samples were prepared using the TruSeq Small RNA Library Prep Kit. These libraries were sequenced on the MiniSeq System using the MiniSeq High Output Reagent Kit at a 1 x 36 bp read length configuration. The total yield was 0.91 Gb with 97% of bases at or above Q30.
Browse the Data In BaseSpace Sequence Hub:
View Run (primary analysis and metrics)
View Project (secondary analysis with BaseSpace Apps)
Specifications:
Assay Time ~10.5 hours
Hands-On Time ~30 minutes
Input Quantity 25 to 100 ng total RNA from species with polyA tails
Content Specifications Captures the coding transcriptome with strand information
Mechanism of Action Oligo-dT beads capture polyA tails
Multiplexing Up to 24-plex pooling with additional NeoPrep runs
Sample Throughput Up to 16 samples per NeoPrep library card
Species Category Drosophila,Any Species,Mouse,Zebrafish,Human,Rat,Plant,Nematode
System Compatibility MiSeq,NextSeq 550,MiniSeq,NextSeq 500
Specialized Sample Types FFPE,Low Input
Technology Sequencing
Automation CapABIlity Liquid Handling Robots
Variant Class Novel Transcripts,Transcript Variants
Method miRNA and Small RNA Sequencing"
Illumina/TruSeq Targeted RNA Index Kit C (96 indexes, 384 samples)/RT-402-1003/1 Ea RT-402-1003 Illumina 產(chǎn)品編號: RT-402-1003美 元 價: $1019.00會 員 價: 待定品 牌: Illumina產(chǎn) 地: 美國公 司: Illumina, Inc.產(chǎn)品分類: 分子類>二代測序>DNA文庫制備試劑盒公司分類: Library Preparation Kits "Product Highlights:
TruSeq Targeted RNA Expression Kits enable highly customizable mid- to high-plex gene expression profiling studies.
You can define panels of 12-1,000 assays to target individual exons, isoforms, splice junctions, coding SNPS (cSNPs), gene fusions, and non-coding RNA transcripts, plus multiplex up to 384 samples. Generate the data equivalent of up to 25,000 individual RT-PCR assays in a single run.*
Assays include convenient online panel design and ordering, a rapid and simple workflow starting with as little as 50 ng of RNA, and automated, on-instrument data analysis.
Types of Study Designs
Custom panels—select up to 1000 targets from a database of over 400,000 predesigned assays.
Add-on (supplemental) content—add a second oligo pool of up to 1000 targets to a previously designed TruSeq Targeted RNA Expression custom panel.
Start a Custom Project
Order custom panels using DesignStudio, a free, user-friendly, web-based tool. Simply select the assays you need and add them to your order, with no design time.
Log in to DesignStudio
Browse TruSeq Targeted RNA Sample Data
Human Brain Reference RNA (HBRR), Universal Human Reference RNA (UHRR), and human liver RNA samples were prepared using the TruSeq Targeted RNA Expression Kit.
These libraries were sequenced on the MiniSeq System using the MiniSeq High Output Reagent Kit at a 1 x 51 bp read length configuration. The total yield was 2.04 Gb with 96.5% of bases at or above Q30.
Note that access to this data requires a BaseSpace Sequence Hub login.
Register for BaseSpace Sequence Hub
View TruSeq Targeted RNA Project Data
(secondary analysis with BaseSpace Apps)
*Refers to instruments with catalog number SY-410-1001 and upgrade, or catalog number SY-410-1003
Specifications:
Assay Time 1 day
Hands-On Time 4 hours
Input Quantity 50 ng RNA,50 ng high-quality total RNA,≥ 200 ng FFPE total RNA; Recommended quantity may vary with expression level, target plexity, and sample quality
Content Specifications Choose from 400,000+ pre-designed targeted RNA-Seq assays. Or add content to a fixed panel or previously designed custom panel.
Multiplexing Up to 384 samples per sequencing run
Mechanism of Action Amplification
Method Targeted RNA Sequencing
Variant Class Single Nucleotide Polymorphisms (SNPs),Gene Fusions,Transcript Variants
Specialized Sample Types FFPE
"
Illumina/TruSeq DNA Methylation Kit (96 reactions)/EGMK91396/1 Ea EGMK91396 Illumina 產(chǎn)品編號: EGMK91396美 元 價: $5567.00會 員 價: 待定品 牌: Illumina產(chǎn) 地: 美國公 司: Illumina, Inc.產(chǎn)品分類: 分子類>二代測序>DNA文庫制備試劑盒公司分類: Library Preparation Kits "Product Highlights:
Unlock small samples (50–100 ng DNA input)
CpG, CHH, & CHG regions included for comprehensive, whole-genome results
Fast protocol – five-hour method
Capture full sample diversity
Sequence the entire sample–no loss of information
The process of bisulfite treatment denatures genomic DNA into single stranded DNA. TruSeq DNA Methylation converts single stranded DNA into an Illumina sequencing library. All ssDNA fragments are captured into an Illumina sequencing library, therefore eliminating the loss of diversity associated with other methods.
Supported analysis in the cloud
TruSeq DNA Methylation libraries can be aligned to the human genome and compared for differential methylation with Illumina BaseSpace Apps MethylSeq and MethylKit. These applications are fully supported and were developed specifically for TruSeq DNA Methylation library preparation.
Example data sets for TruSeq DNA Methylation libraries, also available in BaseSpace Sequence Hub Data Central (use the “Methyl Seq” category filter), demonstrate unparalleled quality and seamless analysis.
Deep coverage of critical genomic regions
Depth of coverage is enhanced in genomic areas with BIOLOGical utility. TruSeq DNA Methylation captures full sample diversity of critical areas, including:
Coding region start and end for exons from the canonical transcript of protein coding genes for genes known to be involved in cancer, taken from SOMA and CRUK panels (as well as literature-derived cancer genes)
Genes defined by the American College of Medical Genetics as being medically relevant (ACMG genes)
Exonic coding regions from Ensemble 70
List of 100 promoters defined by the Broad Institute as being of high interest and difficult to sequence"
Illumina/TruSeq Targeted RNA Index Kit (48 indexes, 48 samples)/RT-401-1001/1 Ea RT-401-1001 Illumina 產(chǎn)品編號: RT-401-1001美 元 價: $698.00會 員 價: 待定品 牌: Illumina產(chǎn) 地: 美國公 司: Illumina, Inc.產(chǎn)品分類: 分子類>二代測序>DNA文庫制備試劑盒公司分類: Library Preparation Kits "Product Highlights:
TruSeq Targeted RNA Expression Kits enable highly customizable mid- to high-plex gene expression profiling studies.
You can define panels of 12-1,000 assays to target individual exons, isoforms, splice junctions, coding SNPS (cSNPs), gene fusions, and non-coding RNA transcripts, plus multiplex up to 384 samples. Generate the data equivalent of up to 25,000 individual RT-PCR assays in a single run.*
Assays include convenient online panel design and ordering, a rapid and simple workflow starting with as little as 50 ng of RNA, and automated, on-instrument data analysis.
Types of Study Designs
Custom panels—select up to 1000 targets from a database of over 400,000 predesigned assays.
Add-on (supplemental) content—add a second oligo pool of up to 1000 targets to a previously designed TruSeq Targeted RNA Expression custom panel.
Start a Custom Project
Order custom panels using DesignStudio, a free, user-friendly, web-based tool. Simply select the assays you need and add them to your order, with no design time.
Log in to DesignStudio
Browse TruSeq Targeted RNA Sample Data
Human Brain Reference RNA (HBRR), Universal Human Reference RNA (UHRR), and human liver RNA samples were prepared using the TruSeq Targeted RNA Expression Kit.
These libraries were sequenced on the MiniSeq System using the MiniSeq High Output Reagent Kit at a 1 x 51 bp read length configuration. The total yield was 2.04 Gb with 96.5% of bases at or above Q30.
Note that access to this data requires a BaseSpace Sequence Hub login.
Register for BaseSpace Sequence Hub
View TruSeq Targeted RNA Project Data
(secondary analysis with BaseSpace Apps)
*Refers to instruments with catalog number SY-410-1001 and upgrade, or catalog number SY-410-1003
Specifications:
Assay Time 1 day
Hands-On Time 4 hours
Input Quantity 50 ng RNA,50 ng high-quality total RNA,≥ 200 ng FFPE total RNA; Recommended quantity may vary with expression level, target plexity, and sample quality
Content Specifications Choose from 400,000+ pre-designed targeted RNA-Seq assays. Or add content to a fixed panel or previously designed custom panel.
Multiplexing Up to 384 samples per sequencing run
Mechanism of Action Amplification
Method Targeted RNA Sequencing
Variant Class Single Nucleotide Polymorphisms (SNPs),Gene Fusions,Transcript Variants
Specialized Sample Types FFPE
"
"Illumina/TruSeq DNA Methylation Kit (24 reactions)/EGMK91324/1 Ea
" EGMK91324 Illumina 產(chǎn)品編號: EGMK91324美 元 價: $1787.00會 員 價: 待定品 牌: Illumina產(chǎn) 地: 美國公 司: Illumina, Inc.產(chǎn)品分類: 分子類>二代測序>DNA文庫制備試劑盒公司分類: Library Preparation Kits "Product Highlights:
Unlock small samples (50–100 ng DNA input)
CpG, CHH, & CHG regions included for comprehensive, whole-genome results
Fast protocol – five-hour method
Capture full sample diversity
Sequence the entire sample–no loss of information
The process of bisulfite treatment denatures genomic DNA into single stranded DNA. TruSeq DNA Methylation converts single stranded DNA into an Illumina sequencing library. All ssDNA fragments are captured into an Illumina sequencing library, therefore eliminating the loss of diversity associated with other methods.
Supported analysis in the cloud
TruSeq DNA Methylation libraries can be aligned to the human genome and compared for differential methylation with Illumina BaseSpace Apps MethylSeq and MethylKit. These applications are fully supported and were developed specifically for TruSeq DNA Methylation library preparation.
Example data sets for TruSeq DNA Methylation libraries, also available in BaseSpace Sequence Hub Data Central (use the “Methyl Seq” category filter), demonstrate unparalleled quality and seamless analysis.
Deep coverage of critical genomic regions
Depth of coverage is enhanced in genomic areas with BIOLOGical utility. TruSeq DNA Methylation captures full sample diversity of critical areas, including:
Coding region start and end for exons from the canonical transcript of protein coding genes for genes known to be involved in cancer, taken from SOMA and CRUK panels (as well as literature-derived cancer genes)
Genes defined by the American College of Medical Genetics as being medically relevant (ACMG genes)
Exonic coding regions from Ensemble 70
List of 100 promoters defined by the Broad Institute as being of high interest and difficult to sequence"
"Illumina/TruSeq Small RNA Set D MiniSeq Kit (1 library prep and 2 MiniSeq reagents)/20005616/1 Ea
" 20005616 Illumina 產(chǎn)品編號: 20005616美 元 價: $3200.00會 員 價: 待定品 牌: Illumina產(chǎn) 地: 美國公 司: Illumina, Inc.產(chǎn)品分類: 分子類>二代測序>DNA文庫制備試劑盒公司分類: Library Preparation Kits "Product Highlights:
TruSeq Small RNA Library Preparation Kits provide reagents to generate small RNA libraries directly from total RNA. MicroRNAs (miRNAs) generated by Dicer processing are efficiently targeted by the included modified adapters.
These kits enable multiplexed sequencing with the introduction of 48 unique indexes, allowing miRNA and small RNA discovery and profiling throughput to match the unparalleled output of Illumina sequencing. Indexes are added in a universal amplification reaction, greatly reducing ligation bias and ensuring accurate measurement of miRNA expression.
Workflow improvements enable streamlined sample preparation, allowing economical studies covering all small RNA transcripts in any species. CompatIBLe applications include finding novel miRNAs, characterizing variation such as isomers with single-base resolution, and analyzing differential expression without prior assumptions.
TruSeq Small RNA Sample Datasets
The Human Brain Reference RNA (HBRR) and Universal Human Reference RNA (UHRR) samples were prepared using the TruSeq Small RNA Library Prep Kit. These libraries were sequenced on the MiniSeq System using the MiniSeq High Output Reagent Kit at a 1 x 36 bp read length configuration. The total yield was 0.91 Gb with 97% of bases at or above Q30.
Browse the Data In BaseSpace Sequence Hub:
View Run (primary analysis and metrics)
View Project (secondary analysis with BaseSpace Apps)
Specifications:
Assay Time ~10.5 hours
Hands-On Time ~30 minutes
Input Quantity 25 to 100 ng total RNA from species with polyA tails
Content Specifications Captures the coding transcriptome with strand information
Mechanism of Action Oligo-dT beads capture polyA tails
Multiplexing Up to 24-plex pooling with additional NeoPrep runs
Sample Throughput Up to 16 samples per NeoPrep library card
Species Category Drosophila,Any Species,Mouse,Zebrafish,Human,Rat,Plant,Nematode
System Compatibility MiSeq,NextSeq 550,MiniSeq,NextSeq 500
Specialized Sample Types FFPE,Low Input
Technology Sequencing
Automation CapABIlity Liquid Handling Robots
Variant Class Novel Transcripts,Transcript Variants
Method miRNA and Small RNA Sequencing"
Illumina/TruSeq DNA Methylation Index PCR Primers (10 reactions, 12 indexes)/EGIDX81312/1 Ea EGIDX81312 Illumina 產(chǎn)品編號: EGIDX81312美 元 價: $78.00會 員 價: 待定品 牌: Illumina產(chǎn) 地: 美國公 司: Illumina, Inc.產(chǎn)品分類: 分子類>二代測序>DNA文庫制備試劑盒公司分類: Library Preparation Kits "Product Highlights:
Unlock small samples (50–100 ng DNA input)
CpG, CHH, & CHG regions included for comprehensive, whole-genome results
Fast protocol – five-hour method
Capture full sample diversity
Sequence the entire sample–no loss of information
The process of bisulfite treatment denatures genomic DNA into single stranded DNA. TruSeq DNA Methylation converts single stranded DNA into an Illumina sequencing library. All ssDNA fragments are captured into an Illumina sequencing library, therefore eliminating the loss of diversity associated with other methods.
Supported analysis in the cloud
TruSeq DNA Methylation libraries can be aligned to the human genome and compared for differential methylation with Illumina BaseSpace Apps MethylSeq and MethylKit. These applications are fully supported and were developed specifically for TruSeq DNA Methylation library preparation.
Example data sets for TruSeq DNA Methylation libraries, also available in BaseSpace Sequence Hub Data Central (use the “Methyl Seq” category filter), demonstrate unparalleled quality and seamless analysis.
Deep coverage of critical genomic regions
Depth of coverage is enhanced in genomic areas with BIOLOGical utility. TruSeq DNA Methylation captures full sample diversity of critical areas, including:
Coding region start and end for exons from the canonical transcript of protein coding genes for genes known to be involved in cancer, taken from SOMA and CRUK panels (as well as literature-derived cancer genes)
Genes defined by the American College of Medical Genetics as being medically relevant (ACMG genes)
Exonic coding regions from Ensemble 70
List of 100 promoters defined by the Broad Institute as being of high interest and difficult to sequence"
Illumina/TruSeq Bovine Parentage Kit (96 indexes, 96 samples)/20004795/1 Ea 20004795 Illumina 產(chǎn)品編號: 20004795美 元 價: $960.00會 員 價: 待定品 牌: Illumina產(chǎn) 地: 美國公 司: Illumina, Inc.產(chǎn)品分類: 分子類>二代測序>DNA文庫制備試劑盒公司分類: Library Preparation Kits "Product Highlights:
This solution for parentage testing of multiple beef and dairy cattle breeds has added genotyping of relevant traits. By offering more information in a single assay than from parentage testing alone, service labs can use the TruSeq Bovine Parentage Sequencing Panel to make more informed herd management recommendations.
Includes all International Society of Animal Genetics (ISAG) recommended content, plus disease-associated and economically relevant traits
Content design, high accuracy, and reliABIlity eliminate need for multiple or repeat testing
Analysis software converts sequencing results to genotype calls without the need for bioinformatics expertise
The TruSeq Bovine Parentage Sequencing Panel uses proven Illumina next-generation sequencing (NGS) technology to deliver accurate genotyping results for SNP-based parentage determination in cattle. The high accuracy and reliABIlity of Illumina sequencing reduces the amount of required testing and shortens the time to answer, leADIng to efficiency gains and cost savings. It features a streamlined workflow that goes from DNA to report in 1.5 days with minimal hands-on time.
Have confidence that the typing result is accurate, the first time. TruSeq Bovine Parentage has been tested with multiple breeds, DNA inputs, and extraction methods. It provides deep sequencing coverage across SNPs.
Specifications:
Input Quantity ≤ 1 ng genomic DNA, or 2 ul crude lysates, or 1.2 mm FTA card punch
Hands-On Time ~1 hour
Assay Time 9 hours
Mechanism of Action PCR
Multiplexing Maximum of 32 casework samples or 96 database or reference samples
System Compatibility MiSeq
Variant Class Single Nucleotide Polymorphisms (SNPs)
Species Category Bovine
Technology Sequencing
Method Genotyping by Sequencing,Amplicon Sequencing,Targeted DNA Sequencing"
"Illumina/TruSeq Ribo Profile for Mammalian (12 reactions, 12 indexes)/RPHMR12126/1 Ea
" RPHMR12126 Illumina 產(chǎn)品編號: RPHMR12126美 元 價: $1575.00會 員 價: 待定品 牌: Illumina產(chǎn) 地: 美國公 司: Illumina, Inc.產(chǎn)品分類: 分子類>二代測序>DNA文庫制備試劑盒公司分類: Library Preparation Kits "Product Highlights:
Study active mRNA translation with sequencing
Sequence ribosome-protected mRNA
Predict protein abundance
Investigate translational control
Measure gene expression
Rapid, scalable spin-column method
No ultracentrifuge required
CompatIBLe with yeast and mammalian samples
Sequence actively translated transcripts
Ribosome profiling is a technique for investigating translational control that provides a snapshot of all the ribosomes active in a cell at a specific time. TruSeq Ribo Profile generates RNA-Seq libraries from ribosome-protected fragments of mRNAs that are actively being translated.
Use TruSeq Ribo Profile to sequence mRNA fragments undergoing translation by ribosomes. These mRNA fragments are called ""footprinted"" or ribosome-protected mRNA fragments.
You can also identify proteins being actively translated from samples prepared with TruSeq Ribo Profile. Samples collected at different times often show changes in translation. Samples treated with different drugs often show different translation patterns.
Specifications:
Input Quantity 0.1 – 1 ug high-quality purified total RNA from blood
Content Specifications Captures coding RNA plus multiple forms of non-coding RNA
Mechanism of Action Bead-based rRNA depletion, CDNA synthesis, and PCR
Multiplexing Low-throughput kits: Pool up to 12 samples. Or pool up to 24 samples with sets A and B together,High-throughput kit version: Prepare 96 uniquely indexed samples
System Compatibility NovaSeq 5000,Genome Analyzer IIx,HiSeq 2000,NextSeq 500,HiSeq 2500
Automation CapABIlity Liquid Handling Robots
Variant Class Transcript Variants
Species Category Rat"
Illumina/TruSeq Small RNA Library Prep Kit -Set D (24 rxns) (Set D: indices 37-48)/RS-200-0048/1 Ea RS-200-0048 Illumina 產(chǎn)品編號: RS-200-0048美 元 價: $2450.00會 員 價: 待定品 牌: Illumina產(chǎn) 地: 美國公 司: Illumina, Inc.產(chǎn)品分類: 分子類>二代測序>DNA文庫制備試劑盒公司分類: Library Preparation Kits "Product Highlights:
TruSeq Small RNA Library Preparation Kits provide reagents to generate small RNA libraries directly from total RNA. MicroRNAs (miRNAs) generated by Dicer processing are efficiently targeted by the included modified adapters.
These kits enable multiplexed sequencing with the introduction of 48 unique indexes, allowing miRNA and small RNA discovery and profiling throughput to match the unparalleled output of Illumina sequencing. Indexes are added in a universal amplification reaction, greatly reducing ligation bias and ensuring accurate measurement of miRNA expression.
Workflow improvements enable streamlined sample preparation, allowing economical studies covering all small RNA transcripts in any species. CompatIBLe applications include finding novel miRNAs, characterizing variation such as isomers with single-base resolution, and analyzing differential expression without prior assumptions.
TruSeq Small RNA Sample Datasets
The Human Brain Reference RNA (HBRR) and Universal Human Reference RNA (UHRR) samples were prepared using the TruSeq Small RNA Library Prep Kit. These libraries were sequenced on the MiniSeq System using the MiniSeq High Output Reagent Kit at a 1 x 36 bp read length configuration. The total yield was 0.91 Gb with 97% of bases at or above Q30.
Browse the Data In BaseSpace Sequence Hub:
View Run (primary analysis and metrics)
View Project (secondary analysis with BaseSpace Apps)
Specifications:
Assay Time ~10.5 hours
Hands-On Time ~30 minutes
Input Quantity 25 to 100 ng total RNA from species with polyA tails
Content Specifications Captures the coding transcriptome with strand information
Mechanism of Action Oligo-dT beads capture polyA tails
Multiplexing Up to 24-plex pooling with additional NeoPrep runs
Sample Throughput Up to 16 samples per NeoPrep library card
Species Category Drosophila,Any Species,Mouse,Zebrafish,Human,Rat,Plant,Nematode
System Compatibility MiSeq,NextSeq 550,MiniSeq,NextSeq 500
Specialized Sample Types FFPE,Low Input
Technology Sequencing
Automation CapABIlity Liquid Handling Robots
Variant Class Novel Transcripts,Transcript Variants
Method miRNA and Small RNA Sequencing"
Illumina/TruSeq Ribo Profile for Yeast (12 reactions, 12 indexes)/RPYSC12116/1 Ea RPYSC12116 Illumina 產(chǎn)品編號: RPYSC12116美 元 價: $1575.00會 員 價: 待定品 牌: Illumina產(chǎn) 地: 美國公 司: Illumina, Inc.產(chǎn)品分類: 分子類>二代測序>DNA文庫制備試劑盒公司分類: Library Preparation Kits "Product Highlights:
Study active mRNA translation with sequencing
Sequence ribosome-protected mRNA
Predict protein abundance
Investigate translational control
Measure gene expression
Rapid, scalable spin-column method
No ultracentrifuge required
CompatIBLe with yeast and mammalian samples
Sequence actively translated transcripts
Ribosome profiling is a technique for investigating translational control that provides a snapshot of all the ribosomes active in a cell at a specific time. TruSeq Ribo Profile generates RNA-Seq libraries from ribosome-protected fragments of mRNAs that are actively being translated.
Use TruSeq Ribo Profile to sequence mRNA fragments undergoing translation by ribosomes. These mRNA fragments are called ""footprinted"" or ribosome-protected mRNA fragments.
You can also identify proteins being actively translated from samples prepared with TruSeq Ribo Profile. Samples collected at different times often show changes in translation. Samples treated with different drugs often show different translation patterns.
Specifications:
Input Quantity 0.1 – 1 ug high-quality purified total RNA from blood
Content Specifications Captures coding RNA plus multiple forms of non-coding RNA
Mechanism of Action Bead-based rRNA depletion, CDNA synthesis, and PCR
Multiplexing Low-throughput kits: Pool up to 12 samples. Or pool up to 24 samples with sets A and B together,High-throughput kit version: Prepare 96 uniquely indexed samples
System Compatibility NovaSeq 5000,Genome Analyzer IIx,HiSeq 2000,NextSeq 500,HiSeq 2500
Automation CapABIlity Liquid Handling Robots
Variant Class Transcript Variants
Species Category Rat"
Illumina/TruSeq Targeted RNA Index Kit B (96 indexes, 384 samples)/RT-402-1002/1 Ea RT-402-1002 Illumina 產(chǎn)品編號: RT-402-1002美 元 價: $1019.00會 員 價: 待定品 牌: Illumina產(chǎn) 地: 美國公 司: Illumina, Inc.產(chǎn)品分類: 分子類>二代測序>DNA文庫制備試劑盒公司分類: Library Preparation Kits "Product Highlights:
TruSeq Targeted RNA Expression Kits enable highly customizable mid- to high-plex gene expression profiling studies.
You can define panels of 12-1,000 assays to target individual exons, isoforms, splice junctions, coding SNPS (cSNPs), gene fusions, and non-coding RNA transcripts, plus multiplex up to 384 samples. Generate the data equivalent of up to 25,000 individual RT-PCR assays in a single run.*
Assays include convenient online panel design and ordering, a rapid and simple workflow starting with as little as 50 ng of RNA, and automated, on-instrument data analysis.
Types of Study Designs
Custom panels—select up to 1000 targets from a database of over 400,000 predesigned assays.
Add-on (supplemental) content—add a second oligo pool of up to 1000 targets to a previously designed TruSeq Targeted RNA Expression custom panel.
Start a Custom Project
Order custom panels using DesignStudio, a free, user-friendly, web-based tool. Simply select the assays you need and add them to your order, with no design time.
Log in to DesignStudio
Browse TruSeq Targeted RNA Sample Data
Human Brain Reference RNA (HBRR), Universal Human Reference RNA (UHRR), and human liver RNA samples were prepared using the TruSeq Targeted RNA Expression Kit.
These libraries were sequenced on the MiniSeq System using the MiniSeq High Output Reagent Kit at a 1 x 51 bp read length configuration. The total yield was 2.04 Gb with 96.5% of bases at or above Q30.
Note that access to this data requires a BaseSpace Sequence Hub login.
Register for BaseSpace Sequence Hub
View TruSeq Targeted RNA Project Data
(secondary analysis with BaseSpace Apps)
*Refers to instruments with catalog number SY-410-1001 and upgrade, or catalog number SY-410-1003
Specifications:
Assay Time 1 day
Hands-On Time 4 hours
Input Quantity 50 ng RNA,50 ng high-quality total RNA,≥ 200 ng FFPE total RNA; Recommended quantity may vary with expression level, target plexity, and sample quality
Content Specifications Choose from 400,000+ pre-designed targeted RNA-Seq assays. Or add content to a fixed panel or previously designed custom panel.
Multiplexing Up to 384 samples per sequencing run
Mechanism of Action Amplification
Method Targeted RNA Sequencing
Variant Class Single Nucleotide Polymorphisms (SNPs),Gene Fusions,Transcript Variants
Specialized Sample Types FFPE
"
Illumina/HiSeq Rapid Duo cBot Sample Loading Kit/CT-403-2001/1 Ea CT-403-2001 Illumina 產(chǎn)品編號: CT-403-2001美 元 價: $440.00會 員 價: 待定品 牌: Illumina產(chǎn) 地: 美國公 司: Illumina, Inc.產(chǎn)品分類: 分子類>二代測序>簇生成和測序試劑公司分類: Cluster Generation & Sequencing Reagents "Product Highlights:
The HiSeq Rapid Duo cBot Sample LoADIng Kit allows maximum indexing freedom in rapid run mode by enabling individually addressable lanes. This kit is an optional accessory for HiSeq Rapid Cluster kits (which require a cBot instrument), and is designed for use in the rapid run workflow of HiSeq 2500 and 1500 sequencers.
Load each flow cell lane independently
Maximize indexing possibilities
Separate precious samples physically
Load different samples in each lane
The HiSeq Rapid Duo cBot Sample LoADIng Kit allows each rapid flow cell lane to be loaded with a unique sample template pool. The duo kit accomplishes individual lane loADIng by allowing a cBot instrument to be used for the template hybridization and first extension steps of the cluster generation process. To use the cBot to load 2 libraries onto a rapid flow cell, 1 HiSeq Rapid Duo cBot Sample LoADIng Kit is required. Each kit contains sufficient reagents for loADIng 1 flow cell.
A specifically designed duo manifold directs each of the 2 samples into the 2 separate rapid flow cell lanes. The cBot portion takes about an hour, after which the flow cell is moved to the HiSeq 2500 or 1500 for further cluster generation steps using a HiSeq Rapid Cluster Kit."
Illumina/PhiX Control v3/FC-110-3001/1 Ea FC-110-3001 Illumina "產(chǎn)品編號: FC-110-3001美 元 價: $160.00會 員 價: 待定品 牌: Illumina產(chǎn) 地: 美國公 司: Illumina, Inc.產(chǎn)品分類: 分子類>二代測序>簇生成和測序試劑公司分類: Cluster Generation & Sequencing Reagents
Size: 1 Ea" "Product Highlights:
PhiX Control v3 is a reliable, adapter-ligated library used as a control for Illumina sequencing runs. The library is derived from the small, well-characterized PhiX genome, offering several benefits for sequencing and alignment.
The versatile PhiX Control v3 is provided as a ready-to-use library, and can be utilized in diverse applications to add value to your workflow and increase confidence in your results.
The PhiX library provides a quality control for cluster generation, sequencing, and alignment, and a calibration control for cross-talk matrix generation, phasing, and prephasing. It can be rapidly aligned to estimate relevant sequencing by synthesis (SBS) metrics such as phasing and error rate.
Depending on the application, PhiX Control v3 may also be utilized:
As a high-concentration spike-in control for unbalanced samples (genomes with AT or GC content of less than 40% or greater than 60%)
As a low-concentration spike-in control for alignment calculations and quantification efficiency
As a dedicated control lane alongside low-diversity samples
As a control for troubleshooting cluster generation problems, to help determine whether an error is related to library preparation
Specifications:
System Compatibility MiSeq,Genome Analyzer IIx,HiSeq 2000,HiSeq X Ten,HiScanSQ,NextSeq 550,HiSeq 3000,HiSeq X Five,HiSeq 1000,MiSeqDx in Research Mode,MiniSeq,HiSeq 1500,NextSeq 500,MiSeq FGx in Research Mode,HiSeq 2500,NovaSeq 6000,HiSeq 4000
Reagent Type Sequencing Control
Technology Sequencing"
Illumina/TruSeq Small RNA Set A MiniSeq Kit (1 library prep and 2 MiniSeq reagents)/20005613/1 Ea 20005613 Illumina 產(chǎn)品編號: 20005613美 元 價: $3200.00會 員 價: 待定品 牌: Illumina產(chǎn) 地: 美國公 司: Illumina, Inc.產(chǎn)品分類: 分子類>二代測序>DNA文庫制備試劑盒公司分類: Library Preparation Kits "Product Highlights:
TruSeq Small RNA Library Preparation Kits provide reagents to generate small RNA libraries directly from total RNA. MicroRNAs (miRNAs) generated by Dicer processing are efficiently targeted by the included modified adapters.
These kits enable multiplexed sequencing with the introduction of 48 unique indexes, allowing miRNA and small RNA discovery and profiling throughput to match the unparalleled output of Illumina sequencing. Indexes are added in a universal amplification reaction, greatly reducing ligation bias and ensuring accurate measurement of miRNA expression.
Workflow improvements enable streamlined sample preparation, allowing economical studies covering all small RNA transcripts in any species. CompatIBLe applications include finding novel miRNAs, characterizing variation such as isomers with single-base resolution, and analyzing differential expression without prior assumptions.
TruSeq Small RNA Sample Datasets
The Human Brain Reference RNA (HBRR) and Universal Human Reference RNA (UHRR) samples were prepared using the TruSeq Small RNA Library Prep Kit. These libraries were sequenced on the MiniSeq System using the MiniSeq High Output Reagent Kit at a 1 x 36 bp read length configuration. The total yield was 0.91 Gb with 97% of bases at or above Q30.
Browse the Data In BaseSpace Sequence Hub:
View Run (primary analysis and metrics)
View Project (secondary analysis with BaseSpace Apps)
Specifications:
Assay Time ~10.5 hours
Hands-On Time ~30 minutes
Input Quantity 25 to 100 ng total RNA from species with polyA tails
Content Specifications Captures the coding transcriptome with strand information
Mechanism of Action Oligo-dT beads capture polyA tails
Multiplexing Up to 24-plex pooling with additional NeoPrep runs
Sample Throughput Up to 16 samples per NeoPrep library card
Species Category Drosophila,Any Species,Mouse,Zebrafish,Human,Rat,Plant,Nematode
System Compatibility MiSeq,NextSeq 550,MiniSeq,NextSeq 500
Specialized Sample Types FFPE,Low Input
Technology Sequencing
Automation CapABIlity Liquid Handling Robots
Variant Class Novel Transcripts,Transcript Variants
Method miRNA and Small RNA Sequencing"
Illumina
Illumina/Infinium Accessory Starter Kit - Mid Throughput (110V)/WG-15-306/1 Ea WG-15-306 Illumina 產(chǎn)品編號: WG-15-306美 元 價: $78000.00會 員 價: 待定品 牌: Illumina產(chǎn) 地: 美國公 司: Illumina, Inc.產(chǎn)品分類: 其它>其它試劑>芯片公司分類: Microarray Kits "Product Highlights:
The Infinium iSelect offers the ABIlity to interrogate virtually any target (e.g. SNP, CNV, INDEL) across any species. Take advantage of the proven Infinium assay technology to create a fully-customized design that is tailored to your unique study needs.
Design a custom genotyping panel that supports up to 700k custom targets (SNPs, indels, and CNVs). The Infinium iSelect can be deployed on either the 24-sample HD (3072 to 90,000 BeadTypes) or 24-sample HTS (90,001 to 700,000 BeadTypes). Creation of these custom assays enables focused, high-throughput genotyping applications tailored to specific project needs.
Keep up-to-date with new discoveries by revising custom content through the Infinium iSelect + (add-on content) option. The Infinium iSelect+ option allows researchers to combine existing Marker sets with new, unique content to create a single BeadChip, thereby increasing the efficiency and cost-effectiveness of custom studies.
Begin custom design and order process
Specifications:
Number of Markers iSelect HD: 3072 to 90,000 custom Markers,iSelect HTS: 90,000 to 700,000 custom Markers
Sample Throughput Up to 5760 samples per week
Input Quantity 200 ng
Species Category Any Species
Technology Microarray
Variant Class Single Nucleotide Polymorphisms (SNPs),Germline Variants,Structural Variants,Insertions-Deletions (indels),Copy Number Variants (CNVs)
Specialized Sample Types FFPE
Automation CapABIlity Liquid Handling Robots,Autoloader 2.x Array Loader
System Compatibility iScan"
"Illumina/Infinium Multi-Ethnic AMR/AFR-8 v1.0 Kit (48 samples)/20001091/1 Ea
" 20001091 Illumina 產(chǎn)品編號: 20001091美 元 價: $5232.00會 員 價: 待定品 牌: Illumina產(chǎn) 地: 美國公 司: Illumina, Inc.產(chǎn)品分類: 其它>其它試劑>芯片公司分類: Infinium Multi-Ethnic AMR "Product Highlights:
The Infinium Multi-Ethnic AMR/AFR-8 Kit provides a multi-purpose, multi-ethnic genotyping array focused on Hispanic and African American populations. With > 1.4 million expertly selected Markers, it enables identification of genetic associations with common and rare traits, providing insight to epidemiologists, health care researchers, population geneticists, and genomic researchers.
Expert-selected content
This kit combines expertly selected Markers and content from the most popular Illumina commercial arrays with the most current genomic information. Researchers can detect both common and rare variants across Hispanic and African American populations and impute variants in a vast number of subpopulations.
Maximized imputation accuracy
Consortium partners developed content for this multi-ethnic AMR/AFR genotyping array using tagging strategies with the power to perform more effective association studies in Hispanic and African American populations. The novel algorithm selects population-specific and transethnic tag SNPs that maximize imputation accuracy, as imputation has become a standard practice in the interpretation of genotyping data and allows for more accurate statistical inference of genotypes not directly genotyped.
Learn More About Human Genotyping
Specifications:
Number of Markers Fixed Markers: 1,430,141u003cbru003eCustom Marker add-on capacity: Up to 245,000
Sample Throughput ~1067 samples per week
Input Quantity 200 ng DNA
Technology Microarray
Variant Class Single Nucleotide Polymorphisms (SNPs),Germline Variants,Structural Variants,Insertions-Deletions (indels),Copy Number Variants (CNVs)
Specialized Sample Types FFPE
Species Category Human
Automation CapABIlity Liquid Handling Robots,Autoloader 2.x Array Loader
System Compatibility iScan"
"Illumina/BovineLD v2.0 BeadChip (48 samples)/WG-451-2001/1 Ea
" WG-451-2001 Illumina 產(chǎn)品編號: WG-451-2001美 元 價: $1200.00會 員 價: 待定品 牌: Illumina產(chǎn) 地: 美國公 司: Illumina, Inc.產(chǎn)品分類: 其它>其它試劑>芯片公司分類: Microarray Kits "Product Highlights:
The BovineLD BeadChip microarray kit enables accurate genotyping to understand the impact of genetics on milk production, reproduction, health, and more. Delivering superior, scalable content at an economical price, it allows you to extend genomic selection to the entire herd. This array offers:
A robust imputation tool to estimate genomic breeding value accurately
High call rates, with demonstrated imputation efficiency of > 98%
Expertly selected content that can be enhanced with up to 80,000 custom Markers
Contains all 200 SNPs on the ISAG panel for bovine parentage (100 core SNPs and 100 additional SNPs)
The ABIlity to interrogate up to 24 samples in parallel
Cost-Effective Genotyping of Herd Animals
The BovineLD v2.0 BeadChip, together with the Infinium BovineSNP50, Infinium BovineHD, and iSelect Custom BeadChips, creates a broad genotyping portfolio that breeders can rely on to characterize genetic variation and accurately estimate genomic breeding value.
While the BovineHD and BovineSNP50 BeadChips provide superior power to interrogate genetic variation in high-value animals and support genome-wide studies, the BovineLD v2.0 BeadChip enables the cost-effective genotyping of lower-value animals.
High Imputation Accuracy
The BeadChip’s strategically selected SNPs possess demonstrated reliABIlity, high average minor allele frequency (MAF), uniform distribution across the bovine genome, and excellent imputation performance for a range of global dairy breeds. The 7,931 SNPs on the BovineLD v2.0 BeadChip were subjected to rigorous functional testing on multiple breeds to ensure strong performance. Illumina ensures that every BovineLD BeadChip offers > 99% average call rate across common dairy and beef cattle breeds.
Superior, Scalable Content
Illumina developed the BovineLD v2.0 BeadChip as part of a BovineLD Consortium in collaboration with global bovine agricultural thought leaders. Illumina scientists and collaborators referenced historical data generated with the BovineSNP50 BeadChip to identify the best SNP content for imputation efficiency among global dairy breeds.1
In silico testing determined that the highest imputation efficiency could be achieved by optimizing MAF among targeted breeds and evenly spacing SNPs across the entire bovine genome with higher Marker densities at the chromosomal ends. Content includes coverage of all chromosomes, including X, known Y haplotypes, and mitochondrial DNA.
High-Throughput Format
The Infinium Assay powers this multi-sample genotyping panel, delivering the industry’s highest call rates and reproducibility. The assay’s PCR-free single-tube sample preparation significantly reduces labor and potential sample handling errors.2,3 A multi-sample format further reduces experimental variABIlity and overall project cost by allowing breeders to interrogate up to 24 samples in parallel.
Learn More About Plant and Animal Genotyping
Specifications:
Input Quantity 200 ng DNA (at 50 ng/ul)
Number of Markers Fixed Markers: 7931 evenly spaced SNPs across the genomeu003cbru003eCustom Marker add-on capacity: Up to 80,000 (with + kit versions)
Technology Microarray
Species Category Bovine
Automation CapABIlity Liquid Handling Robots,Autoloader 2.x Array Loader
System Compatibility iScan"
"Illumina/Infinium® XT Upgrade Kit (24 Beadchips)/20011101/1 Ea
" 20011101 Illumina 產(chǎn)品編號: 20011101美 元 價: $27531.00會 員 價: 待定品 牌: Illumina產(chǎn) 地: 美國公 司: Illumina, Inc.產(chǎn)品分類: 其它>其它試劑>芯片公司分類: Microarray Kits "Product Highlights:
Comprehensive Production-Scale Screening Solution
This solution enables large-scale genetic improvement programs in agrigenomics and supports large-scale screening for biobanks and personalized medicine initiatives. It uses a high-efficiency, flexIBLe workflow.
Production Scale: Optimized assay and 96-sample BeadChip enables processing of 100,000 to upwards of 1,000,000 samples/year per lab
FlexIBLe Content: Targeted single or multispecies assays of 100s to 50,000 SNPs with at least 95% conversion rate guaranteed for custom panels
High Efficiency Workflow: Total assay turnaround time reduced from 3 days to 2 days with less hands-on time
Infinium XT simplifies the custom assay design process, reduces overall hands-on time, and enhances automation robot performance and utilization. The workflow offers an option to reduce the overall turnaround time, if the time to answer is more important than maximum weekly output.
Streamlined Sample Preparation and Data Analysis
A high-throughput solution like Infinium XT needs integrated systems that streamline sample preparation and analysis. The Illumina Automation Control software for the Tecan liquid handling robot has been updated to increase sample processing efficiency. An enhanced data analysis software solution offers real-time data generation and on-demand QC report functionality so production issues can be identified and corrected earlier in the process.
Updated software for GenomeStudio speeds up genotype cluster generation, reducing overall analysis turnaround time. Also, a genotyping module for agricultural and other applications involving polyploid species is now included.
After a cluster file is created, production-level analysis can be transitioned to Beeline Software. This software significantly reduces the time needed to observe quality performance specifications, generate genotyping reports, and analyze polyploid data, without removing the flexibility for manual intervention.
Specifications:
Sample Throughput 100,000 to u003e 1,000,000 samples/year
Number of Markers 100s to 50,000 Markers of interest
Species Category Any Species
Technology Microarray
Variant Class Single Nucleotide Polymorphisms (SNPs),Germline Variants,Insertions-Deletions (indels)
Automation CapABIlity Liquid Handling Robots,Autoloader 2.x Array Loader
System Compatibility iScan
"
"Illumina/Infinium® Omni5Exome-4 v1.3 Kit (16 samples)/20005140/1 Ea
" 20005140 Illumina 產(chǎn)品編號: 20005140美 元 價: $4448.00會 員 價: 待定品 牌: Illumina產(chǎn) 地: 美國公 司: Illumina, Inc.產(chǎn)品分類: 其它>其它試劑>芯片公司分類: Microarray Kits "Product Highlights:
Infinium Omni5Exome-4 BeadChip delivers comprehensive coverage of the genome, providing functional exonic content for whole-genome genotyping and copy number variation (CNV) analysis. The BeadChips include optimized tag SNPs targeting genetic variation down to 1% minor allele frequency (MAF).
Using the proven iScan array scanner and integrated analysis software, these BeadChips offer optimized tag SNPs, exonic content, and fully supported CNV analysis. Combined with convenient packaging and a streamlined PCR-free protocol, these kits provide a comprehensive DNA analysis solution.
Learn More About Human Genotyping
Specifications:
Number of Markers Fixed Markers: 4,548,474
Sample Throughput ~460 samples per week
Input Quantity 400 ng DNA
Technology Microarray
Variant Class Single Nucleotide Polymorphisms (SNPs),Germline Variants,Structural Variants,Insertions-Deletions (indels),Copy Number Variants (CNVs)
Specialized Sample Types FFPE
Species Category Human
Automation CapABIlity Liquid Handling Robots,Autoloader 2.x Array Loader
System Compatibility iScan"
"Illumina/Infinium ImmunoArray-24 v2 BeadChip Kit (1152 samples)/WG-357-1003/1 Ea
" WG-357-1003 Illumina 產(chǎn)品編號: WG-357-1003美 元 價: $49536.00會 員 價: 待定品 牌: Illumina產(chǎn) 地: 美國公 司: Illumina, Inc.產(chǎn)品分類: 其它>其它試劑>芯片公司分類: Microarray Kits "Product Highlights:
The Infinium ImmunoArray-24 v2 BeadChip is the next-generation genotyping array for detecting genetic variation in the human immune system. This BeadChip includes the most valuable content from the HumanImmuno v1 BeadChip, supplemented with newly selected content produced by the immunology research community. This new content includes the majority of the loci currently published in the GWAS catalog for major autoimmune and inflammatory disorders1 as well as published ancestry informative Markers.
Valuable Content
Infinium ImmunoArray-24 v2 BeadChip content highlights:
Over 250,000 immune specific Markers
Over 85,000 new Markers
Includes most valuable content from HumanImmuno v1 BeadChip
Focused on 17 major autoimmune disorders
FlexIBLe Format
The Infinium ImmunoArray-24 v2 can be tailored to incorporate up to ~390,000 custom beadtypes. This BeadChip is available as a standalone version as well as an add-on to several standard Illumina genotyping BeadChips.
Learn More About Human Genotyping
Specifications:
Number of Markers Fixed Markers: ~253,702,Custom Marker add-on capacity: Up to 390,000 (with + kit versions)
Sample Throughput ~5760 samples per week
Input Quantity 200 ng DNA
Technology Microarray
Variant Class Single Nucleotide Polymorphisms (SNPs),Germline Variants,Structural Variants,Insertions-Deletions (indels),Copy Number Variants (CNVs)
Method Targeted Genotyping Array
Specialized Sample Types FFPE
Species Category Human
Automation CapABIlity Liquid Handling Robots,Autoloader 2.x Array Loader
System Compatibility iScan"
"Illumina/Infinium OmniZhongHua-8 v1.3 Kit (96 samples)/20004339/1 Ea
" 20004339 Illumina 產(chǎn)品編號: 20004339美 元 價: $10560.00會 員 價: 待定品 牌: Illumina產(chǎn) 地: 美國公 司: Illumina, Inc.產(chǎn)品分類: 其它>其它試劑>芯片公司分類: Microarray Kits "Product Highlights:
The Infinium OmniZhongHua-8 BeadChip delivers exceptional coverage of common, intermediate, and rare variation found within Chinese populations for genome-wide association studies (GWAS). Optimized tag SNP content from all three HapMap phases and the 1000 Genomes Project (1kGP) has been strategically selected to create a population-focused array for the discovery of novel disease and trait associations in Chinese populations.
The Infinium OmniZhongHua-8 BeadChip allows profiling of > 890,000 Markers per sample. The assay is deployed with proprietary BeadArray technology, delivering exceptionally high data quality with regards to call rates (average > 99%), reproducibility (> 99.9%), and low sample repeat rates. High signal-to-noise ratios and low overall noise levels allow for precise, reliable calls and copy number analyses.
Learn More About Human Genotyping
Specifications:
Number of Markers Fixed Markers: 878,291,Custom Marker add-on capacity: None
Sample Throughput ~960 samples per week
Input Quantity 200 ng DNA
Technology Microarray
Variant Class Single Nucleotide Polymorphisms (SNPs),Germline Variants,Structural Variants,Insertions-Deletions (indels),Copy Number Variants (CNVs)
Specialized Sample Types FFPE
Species Category Human
Automation CapABIlity Liquid Handling Robots,Autoloader 2.x Array Loader
System Compatibility iScan"
"Illumina/Infinium® Omni5Exome-4 v1.3 Kit (48 samples)/20005141/1 Ea
" 20005141 Illumina 產(chǎn)品編號: 20005141美 元 價: $13344.00會 員 價: 待定品 牌: Illumina產(chǎn) 地: 美國公 司: Illumina, Inc.產(chǎn)品分類: 其它>其它試劑>芯片公司分類: Microarray Kits "Product Highlights:
Infinium Omni5Exome-4 BeadChip delivers comprehensive coverage of the genome, providing functional exonic content for whole-genome genotyping and copy number variation (CNV) analysis. The BeadChips include optimized tag SNPs targeting genetic variation down to 1% minor allele frequency (MAF).
Using the proven iScan array scanner and integrated analysis software, these BeadChips offer optimized tag SNPs, exonic content, and fully supported CNV analysis. Combined with convenient packaging and a streamlined PCR-free protocol, these kits provide a comprehensive DNA analysis solution.
Learn More About Human Genotyping
Specifications:
Number of Markers Fixed Markers: 4,548,474
Sample Throughput ~460 samples per week
Input Quantity 400 ng DNA
Technology Microarray
Variant Class Single Nucleotide Polymorphisms (SNPs),Germline Variants,Structural Variants,Insertions-Deletions (indels),Copy Number Variants (CNVs)
Specialized Sample Types FFPE
Species Category Human
Automation CapABIlity Liquid Handling Robots,Autoloader 2.x Array Loader
System Compatibility iScan"
"Illumina/Infinium® Omni5-4 v1.2 Kit (384 samples)/20005153/1 Ea
" 20005153 Illumina 產(chǎn)品編號: 20005153美 元 價: $104832.00會 員 價: 待定品 牌: Illumina產(chǎn) 地: 美國公 司: Illumina, Inc.產(chǎn)品分類: 其它>其它試劑>芯片公司分類: Microarray Kits "Product Highlights:
The Infinium Omni5-4 BeadChip delivers comprehensive coverage of the genome, leveraging powerful tagSNPs selected from the International HapMap and 1000 Genomes Projects that target genetic variation down to 1% minor allele frequency (MAF).
Using the proven iScan System, this four-sample BeadChip offers high-throughput sample processing, and optimized content for whole-genome genotyping and CNV applications.
Learn More About Human Genotyping
Specifications:
Number of Markers Fixed Markers: 4,284,426
Sample Throughput u003e460 samples per week
Input Quantity 400 ng DNA
Technology Microarray
Variant Class Single Nucleotide Polymorphisms (SNPs),Germline Variants,Structural Variants,Insertions-Deletions (indels),Copy Number Variants (CNVs)
Specialized Sample Types FFPE
Species Category Human
Automation CapABIlity Liquid Handling Robots,Autoloader 2.x Array Loader
System Compatibility iScan"
"Illumina/Infinium Multi-Ethnic EUR/EAS/SAS-8 v1.0 Kit (96 samples)/20001102/1 Ea
" 20001102 Illumina 產(chǎn)品編號: 20001102美 元 價: $10464.00會 員 價: 待定品 牌: Illumina產(chǎn) 地: 美國公 司: Illumina, Inc.產(chǎn)品分類: 其它>其它試劑>芯片公司分類: Infinium Multi-Ethnic EUR "Product Highlights:
The Infinium Multi-Ethnic EUR/EAS/SAS-8 Kit provides a multi-purpose, multi-ethnic genotyping array focused on European, East Asian, and South Asian populations. With > 1.4 million expertly selected Markers, it enables identification of genetic associations with common and rare traits, providing insight to epidemiologists, health care researchers, population geneticists, and genomic researchers.
Expert-selected content
This kit combines expertly selected Markers and content from the most popular Illumina commercial arrays with the most current genomic information. Researchers can detect both common and rare variants across European, East Asian, and South Asian populations and impute variants in a vast number of subpopulations.
Maximized imputation accuracy
Consortium partners developed content for this multi-ethnic EUR/EAS/SAS genotyping array using tagging strategies with the power to perform more effective association studies in European, East Asian, and South Asian populations. The novel algorithm selects population-specific and transethnic tag SNPs that maximize imputation accuracy, as imputation has become a standard practice in the interpretation of genotyping data and allows for more accurate statistical inference of genotypes not directly genotyped.
Learn More About Human Genotyping
Specifications:
Number of Markers Fixed Markers: 1,475,140u003cbru003eCustom Marker add-on capacity: Up to 245,000
Sample Throughput ~1067 samples per week
Input Quantity 200 ng DNA
Technology Microarray
Variant Class Single Nucleotide Polymorphisms (SNPs),Germline Variants,Structural Variants,Insertions-Deletions (indels),Copy Number Variants (CNVs)
Specialized Sample Types FFPE
Species Category Human
Automation CapABIlity Liquid Handling Robots,Autoloader 2.x Array Loader
System Compatibility iScan"
"Illumina/Infinium Exome-24 v1.1 Kit (48 samples)/20015246/1 Ea
" 20015246 Illumina 產(chǎn)品編號: 20015246美 元 價: $2256.00會 員 價: 待定品 牌: Illumina產(chǎn) 地: 美國公 司: Illumina, Inc.產(chǎn)品分類: 其它>其它試劑>芯片公司分類: Microarray Kits "Product Highlights:
Infinium Exome-24 BeadChip delivers exceptional coverage of putative functional exonic variants selected from over 12,000 individual exome and whole-genome sequences. Markers were identified through a close collaboration with leADIng geneticists with the goal of developing an extensive catalog of exome variants.
The exonic content consists of >240,000 Markers representing diverse populations - including European, African, Chinese, and Hispanic individuals - and a range of common conditions, such as type 2 diabetes, cancer, metabolic, and psychiatric disorders.
Infinium Exome-24 BeadChip delivers focused coverage of exonic regions, but does not include coverage outside of coding regions. For greater flexibility, the Infinium Exome-24+ version of the BeadChip can be customized to include up to 400,000 additional Markers.
Learn More About Human Genotyping
Specifications:
Number of Markers Fixed Markers: 244,883,Custom Marker add-on capacity: Up to 400,000 (with + kit versions)
Sample Throughput ~2304 samples per week
Input Quantity 200 ng DNA
Technology Microarray
Variant Class Single Nucleotide Polymorphisms (SNPs),Germline Variants,Structural Variants,Insertions-Deletions (indels),Copy Number Variants (CNVs)
Specialized Sample Types FFPE
Species Category Human
Automation CapABIlity Liquid Handling Robots,Autoloader 2.x Array Loader
System Compatibility iScan"
"Illumina/MaizeSNP50 BeadChip (288 samples)/WG-500-1002/1 Ea
" WG-500-1002 Illumina 產(chǎn)品編號: WG-500-1002美 元 價: $14400.00會 員 價: 待定品 牌: Illumina產(chǎn) 地: 美國公 司: Illumina, Inc.產(chǎn)品分類: 其它>其它試劑>芯片公司分類: Microarray Kits "Product Highlights:
The MaizeSNP50 DNA Analysis Kit enables the interrogation of genetic variation across maize lines. Illumina developed this BeadChip array in collaboration with TraitGenetics, the French National Institute for Agricultural Research (INRA), and Syngenta, with the SNP content selected from several public and private sources. This BeadChip contains more than 50,000 validated Markers derived from the B73 reference sequence.
The highly polymorphic SNP content on the MaizeSNP50 BeadChip was subjected to rigorous functional testing across over 30 diverse maize lines to ensure strong performance. Importantly, this BeadChip presents an average of greater than 25 Markers per megabase (Mb), providing ample SNP density for robust whole-genome genotyping studies. In addition, the MaizeSNP50 Marker set increases the ABIlity to perform corn genetic mapping and Marker assisted breeding.
The MaizeSNP50 BeadChip provides high call rates and allows for flexIBLe content deployment.
The assay's single-tube sample preparation without PCR or ligation steps significantly reduces labor and potential sample handling errors
The BeadChip further reduces experimental variABIlity by allowing researchers to interrogate up to 24 samples in parallel
For a low-density option, see the MaizeLD BeadChip Kit.
Learn More About Plant and Animal Genotyping
Specifications:
Input Quantity 200 ng at 50 ng/µl
Number of Markers Fixed Markers: 56,110 evenly distributed SNPs across the genomeu003cbru003eCustom Marker add-on capacity: None
Method Genome-Wide Genotyping Array
Technology Microarray
Automation CapABIlity Liquid Handling Robots,Autoloader 2.x Array Loader
System Compatibility iScan
Species Category Maize"
"Illumina/Infinium CoreExome-24 v1.2 Kit (1152 samples)/20015264/1 Ea
" 20015264 Illumina 產(chǎn)品編號: 20015264美 元 價: $62208.00會 員 價: 待定品 牌: Illumina產(chǎn) 地: 美國公 司: Illumina, Inc.產(chǎn)品分類: 其它>其它試劑>芯片公司分類: Microarray Kits "Product Highlights:
The customizable Infinium CoreExome-24 BeadChip offers an economical way to perform and support large genetic studies, especially large-scale genotyping studies. They can also be used to quickly and easily obtain baseline sample data sets for a variety of downstream applications, including common variant, sex confirmation, mtDNA, ancestry, loss-of-variant, indel, and CNV studies.
Developed in collaboration with several leADIng research institutions, the Infinium CoreExome-24 BeadChip includes all the tag SNPs found on the Infinium Core-24 BeadChip, plus over 240,000 Markers from the Infinium Exome-24 BeadChip. For greater flexibility, the Infinium CoreExome-24+ version of the BeadChip can be customized to include up to 100,000 additional Markers.
The Infinium CoreExome-24 BeadChips use the Infinium high-throughput screening (HTS) 24-sample format, enabling high content flexibility, throughput capacity, and genotyping accuracy. When combined with the proven iScan System, these BeadChips deliver affordable, high-quality, genome-wide information across diverse world populations.
Learn More About Human Genotyping
Specifications:
Number of Markers Fixed Markers: 550,601,Custom Marker add-on capacity: Up to 100,000 (with + kit versions)
Technology Microarray
Variant Class Single Nucleotide Polymorphisms (SNPs),Germline Variants,Structural Variants,Insertions-Deletions (indels),Copy Number Variants (CNVs)
Specialized Sample Types FFPE
Species Category Human
Automation CapABIlity Liquid Handling Robots,Autoloader 2.x Array Loader
System Compatibility iScan"
"Illumina/Infinium Core-24 Kit v1.1 (48 samples)/20015254/1 Ea
" 20015254 Illumina 產(chǎn)品編號: 20015254美 元 價: $2352.00會 員 價: 待定品 牌: Illumina產(chǎn) 地: 美國公 司: Illumina, Inc.產(chǎn)品分類: 其它>其它試劑>芯片公司分類: Microarray Kits "Product Highlights:
The customizable Infinium Core-24 BeadChip offers an economical way to perform and support large genetic studies. Developed in collaboration with several leADIng research institutions, the Infinium Core-24 BeadChip contains highly-informative genome-wide tag SNPs found across diverse world populations, additional high-value Markers (including indels and updated exome-focused content), and has capacity to include up to 300,000 semi-custom Markers.
In addition to cost-effectively performing large-scale genotyping studies, this BeadChip can be used to quickly and easily obtain baseline sample datasets for a variety of downstream applications, including common variant, mtDNA, ancestry, sex confirmation, loss-of-variant, indel, and CNV detection studies.
The Infinium Core-24 BeadChip is based upon the trusted Infinium assay. Using the proven iScan System, this 24-sample BeadChip combines affordABIlity with high-throughput sample processing to deliver high-quality, genome-wide information.
Learn More About Human Genotyping
Specifications:
Number of Markers Fixed Markers: 307,342,Custom Marker add-on capacity: Up to 300,000 (with + kit versions)
Sample Throughput 2304 samples per week
Input Quantity 200 ng DNA
Technology Microarray
Variant Class Single Nucleotide Polymorphisms (SNPs),Germline Variants,Structural Variants,Insertions-Deletions (indels),Copy Number Variants (CNVs)
Specialized Sample Types FFPE
Species Category Human
Automation CapABIlity Liquid Handling Robots,Autoloader 2.x Array Loader
System Compatibility iScan"
"Illumina/CanineHD BeadChip (1152 samples)/WG-440-1003/1 Ea
" WG-440-1003 Illumina 產(chǎn)品編號: WG-440-1003美 元 價: $97920.00會 員 價: 待定品 牌: Illumina產(chǎn) 地: 美國公 司: Illumina, Inc.產(chǎn)品分類: 其它>其它試劑>芯片公司分類: Microarray Kits "Product Highlights:
Featuring highly polymorphic single-nucleotide polymorphism (SNP) content and providing uniform genomic coverage, the CanineHD BeadChip array enables the interrogation of genetic variation in any domestic dog breed.
Importantly, this BeadChip presents an average of greater than 70 Markers per megabase (Mb), providing ample SNP density for robust within-breed association and copy number variation (CNV) studies.
This BeadChip contains more than 170,000 Markers placed on the CanFam2.0 reference sequence. Illumina developed this array in collaboration with the LUPA Consortium, which includes 22 European universities and other partners such as the Broad Institute.
Learn More About Animal and Plant Genotyping
Specifications:
Input Quantity 200 ng DNA (at 50 ng/ul)
Number of Markers Fixed Markers: 172,115 evenly spaced SNPs across the genome
Method Genome-Wide Genotyping Array
Technology Microarray
Specialized Sample Types FFPE
Species Category Canine
Automation CapABIlity Liquid Handling Robots,Autoloader 2.x Array Loader
System Compatibility iScan"
"Illumina/Infinium OncoArray-500K BeadChip Kit (1152 samples) 500,000 loci. Each package contains 48 BeadChips, along wit
" WG-355-1003 Illumina 產(chǎn)品編號: WG-355-1003美 元 價: $74880.00會 員 價: 待定品 牌: Illumina產(chǎn) 地: 美國公 司: Illumina, Inc.產(chǎn)品分類: 其它>其它試劑>芯片公司分類: Microarray Kits "Product Highlights:
The Infinium OncoArray-500K contains 500,000 SNPs with a genome-wide backbone of 250,000 tag SNPs. Additional SNPs include genetic variants associated with breast, colorectal, lung, ovarian, and prostate cancers plus SNPs covering ancestry, quantitative traits, pharmacogenetics, and fine-mapping of common cancer susceptibility loci. To support additional research requirements, the Infinium OncoArray-500K can be tailored to incorporate up to 120,000 custom beadtypes.*
The Infinium OncoArray-500K was developed in collaboration with leADIng experts from the OncoArray consortium†, and draws on many of the features of the successful Collaborative Oncological Gene-environment Study (iCOGS) array1. Designed with candidate SNPs identified by the consortium, the OncoArray provides a cost-effective means to assess candidate variants potentially associated with cancer risk.
The Infinium OncoArray-500K uses a 24-sample high-throughput screening (HTS) BeadChip to enable maximum throughput, productivity, and genotyping accuracy. Using the proven iScan System, the Infinium OncoArray-500K is designed to combine affordABIlity with high-density content, providing insight into the relationship between gene variants and cancer predisposition in five of the most prevalent cancers.
* For additional information about custom add-on content, contact your Illumina account manager or sales specialist.
Learn More About Human Genotyping
Specifications:
Input Quantity 200 ng DNA
Sample Throughput ~2,304 samples per week
Number of Markers Fixed Markers: ~500,000u003cbru003e Custom Marker add-on capacity: Up to 120,000 (with + kit versions)
Technology Microarray
Variant Class Single Nucleotide Polymorphisms (SNPs),Germline Variants,Structural Variants,Insertions-Deletions (indels),Copy Number Variants (CNVs)
Species Category Human
Automation CapABIlity Liquid Handling Robots,Autoloader 2.x Array Loader
System Compatibility iScan"
"Illumina/PorcineSNP60v2 BeadChip (1152 samples)/WG-410-2003/1 Ea
" WG-410-2003 Illumina 產(chǎn)品編號: WG-410-2003美 元 價: $57600.00會 員 價: 待定品 牌: Illumina產(chǎn) 地: 美國公 司: Illumina, Inc.產(chǎn)品分類: 其它>其它試劑>芯片公司分類: Microarray Kits "Product Highlights:
The PorcineSNP60 DNA Analysis Kit v2 features 65,000 evenly spaced probes, offering more than sufficient SNP density for whole-genome association studies, determination of genetic merit, identification of quantitative trait loci, and comparative genetic studies.
This 24-sample BeadChip presents a solution for interrogating genetic variation in multiple porcine breeds, including Duroc, Landrace, Pietran, and Large White. A semi-custom version of the BeadChip, the PorcineSNP60+ DNA Analysis Kit v2, allows researchers to include up to 25,000 additional custom probes for targeted studies.
The Porcine SNP Chip Consortium made the final selection of the highest quality Markers from more than 510,000 single nucleotide polymorphisms (SNPs), after combining novel discovered SNPs with several other existing databases and study results.
The panel was optimized using multiple criteria for Marker selection, including minor allele frequency determined from representative sample sequencing, allele count, quality score, spacing, location, and validation status.
Learn More About Plant and Animal Genotyping
Specifications:
Input Quantity 200 ng DNA
Number of Markers Fixed Markers: 64,232u003cbru003eCustom Marker add-on capacity: Up to 25,000 (with + kit versions)
Method Genome-Wide Genotyping Array
Technology Microarray
Specialized Sample Types FFPE
Species Category Porcine
Automation CapABIlity Liquid Handling Robots,Autoloader 2.x Array Loader
System Compatibility iScan"
"Illumina/Infinium® Omni5Exome-4 v1.3 Kit (96 samples)/20005142/1 Ea
" 20005142 Illumina 產(chǎn)品編號: 20005142美 元 價: $26688.00會 員 價: 待定品 牌: Illumina產(chǎn) 地: 美國公 司: Illumina, Inc.產(chǎn)品分類: 其它>其它試劑>芯片公司分類: Microarray Kits "Product Highlights:
Infinium Omni5Exome-4 BeadChip delivers comprehensive coverage of the genome, providing functional exonic content for whole-genome genotyping and copy number variation (CNV) analysis. The BeadChips include optimized tag SNPs targeting genetic variation down to 1% minor allele frequency (MAF).
Using the proven iScan array scanner and integrated analysis software, these BeadChips offer optimized tag SNPs, exonic content, and fully supported CNV analysis. Combined with convenient packaging and a streamlined PCR-free protocol, these kits provide a comprehensive DNA analysis solution.
Learn More About Human Genotyping
Specifications:
Number of Markers Fixed Markers: 4,548,474
Sample Throughput ~460 samples per week
Input Quantity 400 ng DNA
Technology Microarray
Variant Class Single Nucleotide Polymorphisms (SNPs),Germline Variants,Structural Variants,Insertions-Deletions (indels),Copy Number Variants (CNVs)
Specialized Sample Types FFPE
Species Category Human
Automation CapABIlity Liquid Handling Robots,Autoloader 2.x Array Loader
System Compatibility iScan"
"Illumina/Infinium Exome-24 v1.1 Kit (288 samples)/20015247/1 Ea
" 20015247 Illumina 產(chǎn)品編號: 20015247美 元 價: $13536.00會 員 價: 待定品 牌: Illumina產(chǎn) 地: 美國公 司: Illumina, Inc.產(chǎn)品分類: 其它>其它試劑>芯片公司分類: Microarray Kits "Product Highlights:
Infinium Exome-24 BeadChip delivers exceptional coverage of putative functional exonic variants selected from over 12,000 individual exome and whole-genome sequences. Markers were identified through a close collaboration with leADIng geneticists with the goal of developing an extensive catalog of exome variants.
The exonic content consists of >240,000 Markers representing diverse populations - including European, African, Chinese, and Hispanic individuals - and a range of common conditions, such as type 2 diabetes, cancer, metabolic, and psychiatric disorders.
Infinium Exome-24 BeadChip delivers focused coverage of exonic regions, but does not include coverage outside of coding regions. For greater flexibility, the Infinium Exome-24+ version of the BeadChip can be customized to include up to 400,000 additional Markers.
Learn More About Human Genotyping
Specifications:
Number of Markers Fixed Markers: 244,883,Custom Marker add-on capacity: Up to 400,000 (with + kit versions)
Sample Throughput ~2304 samples per week
Input Quantity 200 ng DNA
Technology Microarray
Variant Class Single Nucleotide Polymorphisms (SNPs),Germline Variants,Structural Variants,Insertions-Deletions (indels),Copy Number Variants (CNVs)
Specialized Sample Types FFPE
Species Category Human
Automation CapABIlity Liquid Handling Robots,Autoloader 2.x Array Loader
System Compatibility iScan"
"Illumina/Infinium CoreExome-24 v1.2 Kit (288 samples)/20015263/1 Ea
" 20015263 Illumina 產(chǎn)品編號: 20015263美 元 價: $15552.00會 員 價: 待定品 牌: Illumina產(chǎn) 地: 美國公 司: Illumina, Inc.產(chǎn)品分類: 其它>其它試劑>芯片公司分類: Microarray Kits "Product Highlights:
The customizable Infinium CoreExome-24 BeadChip offers an economical way to perform and support large genetic studies, especially large-scale genotyping studies. They can also be used to quickly and easily obtain baseline sample data sets for a variety of downstream applications, including common variant, sex confirmation, mtDNA, ancestry, loss-of-variant, indel, and CNV studies.
Developed in collaboration with several leADIng research institutions, the Infinium CoreExome-24 BeadChip includes all the tag SNPs found on the Infinium Core-24 BeadChip, plus over 240,000 Markers from the Infinium Exome-24 BeadChip. For greater flexibility, the Infinium CoreExome-24+ version of the BeadChip can be customized to include up to 100,000 additional Markers.
The Infinium CoreExome-24 BeadChips use the Infinium high-throughput screening (HTS) 24-sample format, enabling high content flexibility, throughput capacity, and genotyping accuracy. When combined with the proven iScan System, these BeadChips deliver affordable, high-quality, genome-wide information across diverse world populations.
Learn More About Human Genotyping
Specifications:
Number of Markers Fixed Markers: 550,601,Custom Marker add-on capacity: Up to 100,000 (with + kit versions)
Technology Microarray
Variant Class Single Nucleotide Polymorphisms (SNPs),Germline Variants,Structural Variants,Insertions-Deletions (indels),Copy Number Variants (CNVs)
Specialized Sample Types FFPE
Species Category Human
Automation CapABIlity Liquid Handling Robots,Autoloader 2.x Array Loader
System Compatibility iScan"
"Illumina/BaseSpace Sequence Hub Enterprise Annual Subscription/SW-411-1003/1 Ea
" SW-411-1003 Illumina 產(chǎn)品編號: SW-411-1003美 元 價: $29995.00會 員 價: 待定品 牌: Illumina產(chǎn) 地: 美國公 司: Illumina, Inc.產(chǎn)品分類: 其它>其它試劑>芯片公司分類: Informatics Products "Product Highlights:
As a key component of the BaseSpace Suite, BaseSpace Sequence Hub is a direct extension of your Illumina instruments. Data flows directly from the instrument into BaseSpace Sequence Hub, which enables you to manage and analyze data using a curated set of analysis apps. BaseSpace Sequence Hub:
Enables you to set up and monitor instrument runs in real-time
Promotes efficiency by converting sequencing data to a standard format and directly streaming them to the cloud
Provides a more economical solution than assembling infrastructures and tools in-house
Increases productivity with easy access and execution of a multitude of genomic analysis apps (provided by you, Illumina, or third-parties). As a result, specialized staff members, such as bioinformaticians are free to work on more complicated analyses
Fosters collaboration and innovation with simplified data sharing
Provides multiple layers of security and supports Health Insurance PortABIlity and AccountABIlity Act (HIPAA) compliance using robust Amazon Web Services cloud infrastructure
Scales to accommodate the need for more storage and computing with a tiered pricing structure
See All BaseSpace Data Analysis Apps
Visit the BaseSpace Suite Blog"
"Illumina/SureRef Reference Female DNA (128 μl)/PR-40-415204-00/1 Ea
" PR-40-415204-00 Illumina 產(chǎn)品編號: PR-40-415204-00美 元 價: $0.00會 員 價: 待定品 牌: Illumina產(chǎn) 地: 美國公 司: Illumina, Inc.產(chǎn)品分類: 其它>其它試劑>芯片公司分類: Clinical Research Products "Product Highlights:
The SureRef Pack contains both SureRef Reference Male DNA and SureRef Reference Female DNA, each sufficient for 16 reference labeling reactions. The individual DNAs are also available separately.
SureRef DNA products are matched, in terms of quality and size of DNA fragment to a single cell or a few cells. Extracted DNA should be amplified with the SurePlex DNA Amplification System and used as part of 24sure laboratory product protocols."
"Illumina/VeriSeq™ PGS Kit - MiSeq®/RH-101-1001/1 Ea
" RH-101-1001 Illumina 產(chǎn)品編號: RH-101-1001美 元 價: $0.00會 員 價: 待定品 牌: Illumina產(chǎn) 地: 美國公 司: Illumina, Inc.產(chǎn)品分類: 其它>其它試劑>芯片公司分類: Clinical Research Products "Product Highlights:
The VeriSeq PGS Kit takes advantage of next-generation sequencing (NGS) technology to provide comprehensive, accurate screening of all 24 chromosomes for selection of embryos most likely to be euploid. Preimplantation genetic screening (PGS) results generated using VeriSeq PGS are comparable to those achieved with the widely used array-based 24sure technology. In addition, NGS offers the opportunity for improved assay workflow, higher throughput, and enhanced performance.1
Industry-leADIng data quality: More than 90% of the world’s sequencing data is generated by Illumina sequencing by synthesis (SBS) chemistry*
Fast, streamlined workflow: Sample to answer in approximately 12 hours
High-throughput analysis: Screen up to 24 samples per run
Ultra-Low Input
NGS offers a highly sensitive method for screening embryos, requiring as little as 1 ng of DNA from a SurePlex DNA amplification reaction. DNA can be obtained from a blastomere biopsy, from a day 3 embryo, or from a trophectodermal (TE) biopsy from a blastocyst.
*Data calculations on file. Illumina, Inc., 2015.
Specifications:
Assay Time 11 hours
Hands-On Time 4 hours
Input Quantity 30 to 300 ng depending on QC results
System Compatibility MiSeq,MiSeqDx in Research Mode
Method PGS Sequencing
Technology Sequencing
Specialized Sample Types Single Cells
Species Category Human
Variant Class Chromosomal Abnormalities,Structural Variants,Copy Number Variants (CNVs)"
"Illumina/Infinium CytoSNP-850K v1.1 BeadChip Kit (48 samples)/WG-322-1103/1 Ea
" WG-322-1103 Illumina 產(chǎn)品編號: WG-322-1103美 元 價: $12000.00會 員 價: 待定品 牌: Illumina產(chǎn) 地: 美國公 司: Illumina, Inc.產(chǎn)品分類: 其它>其它試劑>芯片公司分類: Clinical Research Products "Product Highlights:
The Infinium CytoSNP-850K v1.1 BeadChip is the first SNP-based human microarray to leverage the latest input from the international community for cytogenomics studies. The gene list was defined based on content from the International Collaboration for Clinical Genomics (ICCG)1 and the Cancer Genomics Consortium (CGC)2, providing a comprehensive view of cytogenomic activity.* This enhanced SNP coverage enables copy number calls as small as 10 kb in regions associated with genetic disease.
Thorough Coverage for Constitutional and Cancer Applications
The Infinium CytoSNP-850K v1.1 BeadChip provides comprehensive coverage of cytogenetically relevant genes on a proven platform, helping researchers find valuable information that may be missed by other technologies. It contains approximately 850,000 empirically selected single nucleotide polymorphisms (SNPs) spanning the entire genome with enriched coverage for 3,262 genes of known cytogenetics relevance in both constitutional and cancer applications.
High Detection Sensitivity for Low-level Mosaics
A unique attribute of the Infinium array technology is the use of long 50-mer probes that have high specificity to the SNP target. This increases sensitivity for low-level mosaics3 and offers high resolution for copy-neutral loss of heterozygosity (LOH). In addition, each SNP is represented in at least 15x redundancy to increase the signal-to-noise ratio for making accurate copy number variation (CNV) and absence of heterozygosity (AOH) calls across the genome. As few as 10 consecutive probes are necessary to make accurate CNV calls, demonstrating the high performance level of the Infinium assay.
Specifications:
Assay Time 3 days
Hands-On Time 1 hour 5 min. for automated 8-beadchip workflow,6 hours 15 min. for manual 8-beadchip workflow
Input Quantity 200 ng DNA
Method Genome-Wide Genotyping Array,Cytogenomic Array
Technology Microarray
Variant Class Single Nucleotide Polymorphisms (SNPs),Loss of Heterozygosity (LOH),Chromosomal Abnormalities,Copy Number Variants (CNVs)
Specialized Sample Types FFPE
System Compatibility NextSeq 550,iScan
Species Category Human
Cancer Type Hematological,Solid Tumor"
"Illumina/Infinium CytoSNP-850K v1.1 BeadChip Kit (96 samples)/WG-322-1104/1 Ea
" WG-322-1104 Illumina 產(chǎn)品編號: WG-322-1104美 元 價: $24000.00會 員 價: 待定品 牌: Illumina產(chǎn) 地: 美國公 司: Illumina, Inc.產(chǎn)品分類: 其它>其它試劑>芯片公司分類: Clinical Research Products "Product Highlights:
The Infinium CytoSNP-850K v1.1 BeadChip is the first SNP-based human microarray to leverage the latest input from the international community for cytogenomics studies. The gene list was defined based on content from the International Collaboration for Clinical Genomics (ICCG)1 and the Cancer Genomics Consortium (CGC)2, providing a comprehensive view of cytogenomic activity.* This enhanced SNP coverage enables copy number calls as small as 10 kb in regions associated with genetic disease.
Thorough Coverage for Constitutional and Cancer Applications
The Infinium CytoSNP-850K v1.1 BeadChip provides comprehensive coverage of cytogenetically relevant genes on a proven platform, helping researchers find valuable information that may be missed by other technologies. It contains approximately 850,000 empirically selected single nucleotide polymorphisms (SNPs) spanning the entire genome with enriched coverage for 3,262 genes of known cytogenetics relevance in both constitutional and cancer applications.
High Detection Sensitivity for Low-level Mosaics
A unique attribute of the Infinium array technology is the use of long 50-mer probes that have high specificity to the SNP target. This increases sensitivity for low-level mosaics3 and offers high resolution for copy-neutral loss of heterozygosity (LOH). In addition, each SNP is represented in at least 15x redundancy to increase the signal-to-noise ratio for making accurate copy number variation (CNV) and absence of heterozygosity (AOH) calls across the genome. As few as 10 consecutive probes are necessary to make accurate CNV calls, demonstrating the high performance level of the Infinium assay.
Specifications:
Assay Time 3 days
Hands-On Time 1 hour 5 min. for automated 8-beadchip workflow,6 hours 15 min. for manual 8-beadchip workflow
Input Quantity 200 ng DNA
Method Genome-Wide Genotyping Array,Cytogenomic Array
Technology Microarray
Variant Class Single Nucleotide Polymorphisms (SNPs),Loss of Heterozygosity (LOH),Chromosomal Abnormalities,Copy Number Variants (CNVs)
Specialized Sample Types FFPE
System Compatibility NextSeq 550,iScan
Species Category Human
Cancer Type Hematological,Solid Tumor"
"Illumina/24sure Microarray Pack (16 hybridizations, up to 32 samples)/PR-10-408702-PK/1 Ea
" PR-10-408702-PK Illumina 產(chǎn)品編號: PR-10-408702-PK美 元 價: $3530.00會 員 價: 待定品 牌: Illumina產(chǎn) 地: 美國公 司: Illumina, Inc.產(chǎn)品分類: 其它>其它試劑>芯片公司分類: Clinical Research Products "Product Highlights:
Preimplantation genetic screening (PGS) with 24sure microarrays provides a comprehensive and accurate assessment of all 24 chromosomes from an embryo biopsy. The arrays can be used to screen for aneuploidy in first and second polar bodies, blastomere biopsies, and trophectoderm biopsies. The 24sure assay is objective, ensuring a high degree of confidence in the results and subsequent selection of embryos least likely to have aneuploidy for transfer.
Widely used, proven PGS – Method of choice for many of the world’s reference laboratories
Fast, reliable results – Comprehensive, accurate assessment of all 24 chromosomes in 12 hours
Straightforward workflow – Optimized protocols include minimal tube transfers, documented quality control (QC) stages, and flexIBLe stopping points
Straightforward Workflow Is Complete in 12 Hours
The straightforward 24sure protocol used standard laboratory techniques, providing a fast, accurate method for chromosome screening with minimal sensitivity to technical errors and designed to fit into existing workflows. Screening can be completed in 12 hours, and therefore does not interfere with tight schedules of a fresh IVF cycle.
Specifications:
Assay Time ~12 hours
Hands-On Time ~2.5 hours
Input Quantity Single cell or multi-cell samples
Technology Microarray
Specialized Sample Types Single Cells
Species Category Human
Variant Class Chromosomal Abnormalities,Structural Variants,Copy Number Variants (CNVs)
Method PGS Array
Significantly Higher Rate of Pregnancy May Be PossIBLe with PGS:
The pregnancy rate shown for embryos analyzed using preimplantation genetic screening and morphology is 69.1%, much higher than the 41.7% achieved using morphology screening alone.1 Pilot study of young, good prognosis patients (age < 35, first-time IVF, no history of prior miscarriage, n = 103).
PGS with 24sure Arrays Reduces the Effect of Maternal Age on Implantation and Pregnancy Rates:
Although aneuploidy risk increases with maternal age, PGS using 24sure arrays on either day 3 or day 5 embryos diminishes the effect of maternal age on implantation and pregnancy rates.2
24Sure Laboratory Workflow:
The 24sure laboratory workflow is a straightforward procedure that is completed in <12 hours.
BlueFuse Multi Software Delivers a Complete Data Analysis and Information Management System:
BlueFuse Multi Software provides a complete solution for analyzing, storing, and reporting 24sure results. A. Sample database displays experimental information. B. Array images imported directly from the scanner. C. Profiles for sample and reference chromosomes. D. Automated cycle reports."
"Illumina/HumanCytoSNP FFPE-12 v2.1 DNA Analysis BeadChip Kit (24 samples) 250,000 loci. Each package contains 2 BeadChip
" WG-321-1003 Illumina 產(chǎn)品編號: WG-321-1003美 元 價: $3720.00會 員 價: 待定品 牌: Illumina產(chǎn) 地: 美國公 司: Illumina, Inc.產(chǎn)品分類: 其它>其它試劑>芯片公司分類: Clinical Research Products "Product Highlights:
The HumanCytoSNP FFPE-12 BeadChip interrogates >262,000 genomic Markers. The content consists of intelligently selected tag SNPs that provide comprehensive genomic coverage.
With dense and even Marker spacing, the BeadChip content can also be used to precisely detect structural aberrations, allowing researchers to accurately identify structural differences between paired-normal and tumor samples.
Specifications:
Assay Time 3 days
Hands-On Time 1 hour 5 min. for automated 8-beadchip workflow,2 hours 10 min. for manual 8-beadchip workflow
Input Quantity 200 ng DNA
Method Genome-Wide Genotyping Array,Cytogenomic Array
Technology Microarray
Variant Class Single Nucleotide Polymorphisms (SNPs),Loss of Heterozygosity (LOH),Chromosomal Abnormalities,Copy Number Variants (CNVs)
Specialized Sample Types FFPE
System Compatibility NextSeq 550,iScan
Species Category Human
Cancer Type Hematological,Solid Tumor"
"Illumina/24sure+ Pack (16 samples)/PR-10-408602-PK/1 Ea
" PR-10-408602-PK Illumina 產(chǎn)品編號: PR-10-408602-PK美 元 價: $4460.00會 員 價: 待定品 牌: Illumina產(chǎn) 地: 美國公 司: Illumina, Inc.產(chǎn)品分類: 其它>其它試劑>芯片公司分類: Clinical Research Products "Product Highlights:
The 24sure+ microarray is designed to improve the success of in vitro fertilization (IVF) by detecting subchromosomal imbalances in embryos of reciprocal translocation carriers. 24sure+ includes increased coverage of pericentromeric and subtelomeric regions to ensure the identification and reporting of small derived chromosome fragments from single cells.
24sure+ microarrays offer several key advantages:
24sure+ can more accurately determine balanced or euploid embryos for selection compared to trADItional fluorescent in situ hybridization (FISH) methods1
Rapid workflow enables sample results and reporting within 12 hours
Every 24sure+ purchase includes BlueFuse Multi software for the fully automated analysis, interpretation, and reporting of 24sure+ investigations
24sure+ analysis is ideally offered to couples undergoing IVF due to recurrent miscarriages sUSPected to be caused by the presence of a balanced translocation in either parent. Balanced translocation carriers may not present with a phenotype. However, segregation of the translocated chromosomes during gamete formation can produce a range of normal, balanced, and unbalanced gametes, with unbalanced products expected to represent 50% of gametes.2 Resulting embryos with large structural imbalances are likely to be non-viable. As a result, the balanced carrier may present with infertility or a history of recurrent miscarriage/spontaneous abortion.3
Couples presenting with recurrent miscarriage can be karyotyped, which is a low-resolution analysis that may determine whether the problems they are experiencing are due to a balanced rearrangement. If this is the case, such carriers of balanced translocations may seek 24sure+ analysis of embryos.
Specifications:
Assay Time ~12 hours
Hands-On Time ~3.5 hours
Input Quantity SurePlex whole-genome-amplified single cells from embryo biopsies
Technology Microarray
Method PGD Array
Specialized Sample Types Single Cells
Species Category Human
Variant Class Chromosomal Abnormalities"
"Illumina/HumanCytoSNP-12 v2.1 BeadChip Kit (12 samples)/WG-320-2101/1 Ea
" WG-320-2101 Illumina 產(chǎn)品編號: WG-320-2101美 元 價: $1860.00會 員 價: 待定品 牌: Illumina產(chǎn) 地: 美國公 司: Illumina, Inc.產(chǎn)品分類: 其它>其它試劑>芯片公司分類: Clinical Research Products "Product Highlights:
The 12-sample HumanCytoSNP-12 BeadChip is a powerful, whole-genome scanning panel designed for efficient, high-throughput analysis of genetic and structural variations that are most relevant to human disease. This scalable, proven solution offers substantially better resolution to detect smaller regions than fluorescence in situ hybridization (FISH) or comparative genomic hybridization (CGH).1
Complete panel of genome-wide tag single nucleotide polymorphisms (SNPs) and Markers targeting all regions of known cytogenetic importance, incorporating ~300,000 “best of the best” SNPs with the highest tagging power
Average SNP call rates and reproducibility of > 99.9%, and low noise for copy number measurements
Detect many types and sizes of structural variation in the human genome that affect phenotypes, including duplications, deletions, amplifications, copy-neutral loss of heterozygosity (LOH), and mosaicism
Process up to 12 samples in parallel, increasing sample throughput and decreasing experimental variABIlity
Process samples using the single-tube, PCR-free Infinium HD Assay that requires only 200ng DNA per sample
Comprehensive data analysis with intuitive BlueFuse Multi Software streamlines copy number assessment and results reporting
The HumanCytoSNP-12 BeadChip is optimized to detect cytogenetic abnormalities most relevant to human disease.1-2 Content includes ~300,000 SNPs targeting regions shown to be important for cytogenetic analysis. The result is dense coverage of ~250 disease regions, including subtelomeric regions, pericentromeric regions, and sex chromosomes, commonly screened in cytogenetics labs. Sufficient SNP coverage is provided to determine dosage sensitivity of > 800 genes.
Specifications:
Assay Time 3 days
Hands-On Time 1 hour 5 min. for automated 8-beadchip workflow,6 hours 15 min. for manual 8-beadchip workflow
Input Quantity 200 ng DNA
Method Genome-Wide Genotyping Array,Cytogenomic Array
Technology Microarray
Variant Class Single Nucleotide Polymorphisms (SNPs),Loss of Heterozygosity (LOH),Chromosomal Abnormalities,Copy Number Variants (CNVs)
System Compatibility NextSeq 550,iScan
Species Category Human
Cancer Type Hematological,Solid Tumor"
Illumina/Infinium CytoSNP-850K v1.1 BeadChip Kit (8 samples)/WG-322-1101/1 Ea WG-322-1101 Illumina 產(chǎn)品編號: WG-322-1101美 元 價: $2000.00會 員 價: 待定品 牌: Illumina產(chǎn) 地: 美國公 司: Illumina, Inc.產(chǎn)品分類: 其它>其它試劑>芯片公司分類: Clinical Research Products "Product Highlights:
The Infinium CytoSNP-850K v1.1 BeadChip is the first SNP-based human microarray to leverage the latest input from the international community for cytogenomics studies. The gene list was defined based on content from the International Collaboration for Clinical Genomics (ICCG)1 and the Cancer Genomics Consortium (CGC)2, providing a comprehensive view of cytogenomic activity.* This enhanced SNP coverage enables copy number calls as small as 10 kb in regions associated with genetic disease.
Thorough Coverage for Constitutional and Cancer Applications
The Infinium CytoSNP-850K v1.1 BeadChip provides comprehensive coverage of cytogenetically relevant genes on a proven platform, helping researchers find valuable information that may be missed by other technologies. It contains approximately 850,000 empirically selected single nucleotide polymorphisms (SNPs) spanning the entire genome with enriched coverage for 3,262 genes of known cytogenetics relevance in both constitutional and cancer applications.
High Detection Sensitivity for Low-level Mosaics
A unique attribute of the Infinium array technology is the use of long 50-mer probes that have high specificity to the SNP target. This increases sensitivity for low-level mosaics3 and offers high resolution for copy-neutral loss of heterozygosity (LOH). In addition, each SNP is represented in at least 15x redundancy to increase the signal-to-noise ratio for making accurate copy number variation (CNV) and absence of heterozygosity (AOH) calls across the genome. As few as 10 consecutive probes are necessary to make accurate CNV calls, demonstrating the high performance level of the Infinium assay.
Specifications:
Assay Time 3 days
Hands-On Time 1 hour 5 min. for automated 8-beadchip workflow,6 hours 15 min. for manual 8-beadchip workflow
Input Quantity 200 ng DNA
Method Genome-Wide Genotyping Array,Cytogenomic Array
Technology Microarray
Variant Class Single Nucleotide Polymorphisms (SNPs),Loss of Heterozygosity (LOH),Chromosomal Abnormalities,Copy Number Variants (CNVs)
Specialized Sample Types FFPE
System Compatibility NextSeq 550,iScan
Species Category Human
Cancer Type Hematological,Solid Tumor"
"Illumina/Infinium CytoSNP-850K v1.1 BeadChip Kit (16 samples)/WG-322-1102/1 Ea
" WG-322-1102 Illumina 產(chǎn)品編號: WG-322-1102美 元 價: $4000.00會 員 價: 待定品 牌: Illumina產(chǎn) 地: 美國公 司: Illumina, Inc.產(chǎn)品分類: 其它>其它試劑>芯片公司分類: Clinical Research Products "Product Highlights:
The Infinium CytoSNP-850K v1.1 BeadChip is the first SNP-based human microarray to leverage the latest input from the international community for cytogenomics studies. The gene list was defined based on content from the International Collaboration for Clinical Genomics (ICCG)1 and the Cancer Genomics Consortium (CGC)2, providing a comprehensive view of cytogenomic activity.* This enhanced SNP coverage enables copy number calls as small as 10 kb in regions associated with genetic disease.
Thorough Coverage for Constitutional and Cancer Applications
The Infinium CytoSNP-850K v1.1 BeadChip provides comprehensive coverage of cytogenetically relevant genes on a proven platform, helping researchers find valuable information that may be missed by other technologies. It contains approximately 850,000 empirically selected single nucleotide polymorphisms (SNPs) spanning the entire genome with enriched coverage for 3,262 genes of known cytogenetics relevance in both constitutional and cancer applications.
High Detection Sensitivity for Low-level Mosaics
A unique attribute of the Infinium array technology is the use of long 50-mer probes that have high specificity to the SNP target. This increases sensitivity for low-level mosaics3 and offers high resolution for copy-neutral loss of heterozygosity (LOH). In addition, each SNP is represented in at least 15x redundancy to increase the signal-to-noise ratio for making accurate copy number variation (CNV) and absence of heterozygosity (AOH) calls across the genome. As few as 10 consecutive probes are necessary to make accurate CNV calls, demonstrating the high performance level of the Infinium assay.
Specifications:
Assay Time 3 days
Hands-On Time 1 hour 5 min. for automated 8-beadchip workflow,6 hours 15 min. for manual 8-beadchip workflow
Input Quantity 200 ng DNA
Method Genome-Wide Genotyping Array,Cytogenomic Array
Technology Microarray
Variant Class Single Nucleotide Polymorphisms (SNPs),Loss of Heterozygosity (LOH),Chromosomal Abnormalities,Copy Number Variants (CNVs)
Specialized Sample Types FFPE
System Compatibility NextSeq 550,iScan
Species Category Human
Cancer Type Hematological,Solid Tumor"
"Illumina/HumanCytoSNP FFPE-12 v2.1 DNA Analysis BeadChip Kit (48 samples) 250,000 loci. Each package contains 4 BeadChip
" WG-321-1004 Illumina 產(chǎn)品編號: WG-321-1004美 元 價: $6960.00會 員 價: 待定品 牌: Illumina產(chǎn) 地: 美國公 司: Illumina, Inc.產(chǎn)品分類: 其它>其它試劑>芯片公司分類: Clinical Research Products "Product Highlights:
The HumanCytoSNP FFPE-12 BeadChip interrogates >262,000 genomic Markers. The content consists of intelligently selected tag SNPs that provide comprehensive genomic coverage.
With dense and even Marker spacing, the BeadChip content can also be used to precisely detect structural aberrations, allowing researchers to accurately identify structural differences between paired-normal and tumor samples.
Specifications:
Assay Time 3 days
Hands-On Time 1 hour 5 min. for automated 8-beadchip workflow,2 hours 10 min. for manual 8-beadchip workflow
Input Quantity 200 ng DNA
Method Genome-Wide Genotyping Array,Cytogenomic Array
Technology Microarray
Variant Class Single Nucleotide Polymorphisms (SNPs),Loss of Heterozygosity (LOH),Chromosomal Abnormalities,Copy Number Variants (CNVs)
Specialized Sample Types FFPE
System Compatibility NextSeq 550,iScan
Species Category Human
Cancer Type Hematological,Solid Tumor"
Illumina/HumanKaryomap-12 DNA Analysis Kit (24 samples)/RH-103-1001/1 Ea RH-103-1001 Illumina 產(chǎn)品編號: RH-103-1001美 元 價: $3758.00會 員 價: 待定品 牌: Illumina產(chǎn) 地: 美國公 司: Illumina, Inc.產(chǎn)品分類: 其它>其它試劑>芯片公司分類: Clinical Research Products "Product Highlights:
The HumanKaryomap-12 DNA Analysis Kit is a comprehensive genome-wide test available at the single-cell level. It provides insight into the inheritance of single-gene defects.
This BeadChip array targets ~300,000 of the most informative Markers in the genome for efficient genome-wide coverage. Karyomapping uses bioMarkers within the genome to assess the likelihood of an embryo carrying a gene variant involved in a single-gene disorder.
Preimplantation genetic diagnosis (PGD) with karyomapping enables screening of embryos for the likelihood of carrying the defective gene prior to transfer to the uterus. This method uses SNP (single nucleotide polymorphisms) array technology to confirm the presence or absence of a specific allele.
Specifications:
Assay Time ~2 days (shortened Infinium protocol)
Hands-on Time ~4 hours
Input Quantity 400 ng genomic DNA from parent and reference samples + SureMDA whole-genome-amplified single cells from embryo biopsy samples
Technology Microarray
Variant Class Single Nucleotide Polymorphisms (SNPs)
System Compatibility NextSeq 550,iScan
Method PGD Array
Specialized Sample Types Single Cells
Species Category Human"
Illumina/SureRef Reference Male DNA (128 ?l)/PR-40-415203-00/1 Ea PR-40-415203-00 Illumina 產(chǎn)品編號: PR-40-415203-00美 元 價: $0.00會 員 價: 待定品 牌: Illumina產(chǎn) 地: 美國公 司: Illumina, Inc.產(chǎn)品分類: 其它>其它試劑>芯片公司分類: Clinical Research Products "Product Highlights:
The SureRef Pack contains both SureRef Reference Male DNA and SureRef Reference Female DNA, each sufficient for 16 reference labeling reactions. The individual DNAs are also available separately.
SureRef DNA products are matched, in terms of quality and size of DNA fragment to a single cell or a few cells. Extracted DNA should be amplified with the SurePlex DNA Amplification System and used as part of 24sure laboratory product protocols."
"Illumina/SurePlex DNA Amplification System (50 reactions)/PR-40-415101-00/1 Ea
" PR-40-415101-00 Illumina 產(chǎn)品編號: PR-40-415101-00美 元 價: $1380.00會 員 價: 待定品 牌: Illumina產(chǎn) 地: 美國公 司: Illumina, Inc.產(chǎn)品分類: 其它>其它試劑>芯片公司分類: Clinical Research Products "Product Highlights:
Preimplantation genetic screening (PGS) with 24sure microarrays provides a comprehensive and accurate assessment of all 24 chromosomes from an embryo biopsy. The arrays can be used to screen for aneuploidy in first and second polar bodies, blastomere biopsies, and trophectoderm biopsies. The 24sure assay is objective, ensuring a high degree of confidence in the results and subsequent selection of embryos least likely to have aneuploidy for transfer.
Widely used, proven PGS – Method of choice for many of the world’s reference laboratories
Fast, reliable results – Comprehensive, accurate assessment of all 24 chromosomes in 12 hours
Straightforward workflow – Optimized protocols include minimal tube transfers, documented quality control (QC) stages, and flexIBLe stopping points
Straightforward Workflow Is Complete in 12 Hours
The straightforward 24sure protocol used standard laboratory techniques, providing a fast, accurate method for chromosome screening with minimal sensitivity to technical errors and designed to fit into existing workflows. Screening can be completed in 12 hours, and therefore does not interfere with tight schedules of a fresh IVF cycle.
Specifications:
Assay Time ~12 hours
Hands-On Time ~2.5 hours
Input Quantity Single cell or multi-cell samples
Technology Microarray
Specialized Sample Types Single Cells
Species Category Human
Variant Class Chromosomal Abnormalities,Structural Variants,Copy Number Variants (CNVs)
Method PGS Array
Significantly Higher Rate of Pregnancy May Be PossIBLe with PGS:
The pregnancy rate shown for embryos analyzed using preimplantation genetic screening and morphology is 69.1%, much higher than the 41.7% achieved using morphology screening alone.1 Pilot study of young, good prognosis patients (age < 35, first-time IVF, no history of prior miscarriage, n = 103).
PGS with 24sure Arrays Reduces the Effect of Maternal Age on Implantation and Pregnancy Rates:
Although aneuploidy risk increases with maternal age, PGS using 24sure arrays on either day 3 or day 5 embryos diminishes the effect of maternal age on implantation and pregnancy rates.2
24Sure Laboratory Workflow:
The 24sure laboratory workflow is a straightforward procedure that is completed in <12 hours.
BlueFuse Multi Software Delivers a Complete Data Analysis and Information Management System:
BlueFuse Multi Software provides a complete solution for analyzing, storing, and reporting 24sure results. A. Sample database displays experimental information. B. Array images imported directly from the scanner. C. Profiles for sample and reference chromosomes. D. Automated cycle reports."
"Illumina/HumanCytoSNP-12 v2.1 BeadChip Kit (288 samples)/WG-320-2104/1 Ea
" WG-320-2104 Illumina 產(chǎn)品編號: WG-320-2104美 元 價: $41760.00會 員 價: 待定品 牌: Illumina產(chǎn) 地: 美國公 司: Illumina, Inc.產(chǎn)品分類: 其它>其它試劑>芯片公司分類: Clinical Research Products "Product Highlights:
The 12-sample HumanCytoSNP-12 BeadChip is a powerful, whole-genome scanning panel designed for efficient, high-throughput analysis of genetic and structural variations that are most relevant to human disease. This scalable, proven solution offers substantially better resolution to detect smaller regions than fluorescence in situ hybridization (FISH) or comparative genomic hybridization (CGH).1
Complete panel of genome-wide tag single nucleotide polymorphisms (SNPs) and Markers targeting all regions of known cytogenetic importance, incorporating ~300,000 “best of the best” SNPs with the highest tagging power
Average SNP call rates and reproducibility of > 99.9%, and low noise for copy number measurements
Detect many types and sizes of structural variation in the human genome that affect phenotypes, including duplications, deletions, amplifications, copy-neutral loss of heterozygosity (LOH), and mosaicism
Process up to 12 samples in parallel, increasing sample throughput and decreasing experimental variABIlity
Process samples using the single-tube, PCR-free Infinium HD Assay that requires only 200ng DNA per sample
Comprehensive data analysis with intuitive BlueFuse Multi Software streamlines copy number assessment and results reporting
The HumanCytoSNP-12 BeadChip is optimized to detect cytogenetic abnormalities most relevant to human disease.1-2 Content includes ~300,000 SNPs targeting regions shown to be important for cytogenetic analysis. The result is dense coverage of ~250 disease regions, including subtelomeric regions, pericentromeric regions, and sex chromosomes, commonly screened in cytogenetics labs. Sufficient SNP coverage is provided to determine dosage sensitivity of > 800 genes.
Specifications:
Assay Time 3 days
Hands-On Time 1 hour 5 min. for automated 8-beadchip workflow,6 hours 15 min. for manual 8-beadchip workflow
Input Quantity 200 ng DNA
Method Genome-Wide Genotyping Array,Cytogenomic Array
Technology Microarray
Variant Class Single Nucleotide Polymorphisms (SNPs),Loss of Heterozygosity (LOH),Chromosomal Abnormalities,Copy Number Variants (CNVs)
System Compatibility NextSeq 550,iScan
Species Category Human
Cancer Type Hematological,Solid Tumor"
"Illumina/SureMDA DNA Amplification System (96 reactions)/PR-40-405102-00/1 Ea
" PR-40-405102-00 Illumina 產(chǎn)品編號: PR-40-405102-00美 元 價: $2920.00會 員 價: 待定品 牌: Illumina產(chǎn) 地: 美國公 司: Illumina, Inc.產(chǎn)品分類: 其它>其它試劑>芯片公司分類: Clinical Research Products "Product Highlights:
The HumanKaryomap-12 DNA Analysis Kit is a comprehensive genome-wide test available at the single-cell level. It provides insight into the inheritance of single-gene defects.
This BeadChip array targets ~300,000 of the most informative Markers in the genome for efficient genome-wide coverage. Karyomapping uses bioMarkers within the genome to assess the likelihood of an embryo carrying a gene variant involved in a single-gene disorder.
Preimplantation genetic diagnosis (PGD) with karyomapping enables screening of embryos for the likelihood of carrying the defective gene prior to transfer to the uterus. This method uses SNP (single nucleotide polymorphisms) array technology to confirm the presence or absence of a specific allele.
Specifications:
Assay Time ~2 days (shortened Infinium protocol)
Hands-on Time ~4 hours
Input Quantity 400 ng genomic DNA from parent and reference samples + SureMDA whole-genome-amplified single cells from embryo biopsy samples
Technology Microarray
Variant Class Single Nucleotide Polymorphisms (SNPs)
System Compatibility NextSeq 550,iScan
Method PGD Array
Specialized Sample Types Single Cells
Species Category Human"
"Illumina/HumanCytoSNP-12 v2.1 BeadChip Kit (24 samples)/WG-320-2102/1 Ea
" WG-320-2102 Illumina 產(chǎn)品編號: WG-320-2102美 元 價: $3720.00會 員 價: 待定品 牌: Illumina產(chǎn) 地: 美國公 司: Illumina, Inc.產(chǎn)品分類: 其它>其它試劑>芯片公司分類: Clinical Research Products "Product Highlights:
The 12-sample HumanCytoSNP-12 BeadChip is a powerful, whole-genome scanning panel designed for efficient, high-throughput analysis of genetic and structural variations that are most relevant to human disease. This scalable, proven solution offers substantially better resolution to detect smaller regions than fluorescence in situ hybridization (FISH) or comparative genomic hybridization (CGH).1
Complete panel of genome-wide tag single nucleotide polymorphisms (SNPs) and Markers targeting all regions of known cytogenetic importance, incorporating ~300,000 “best of the best” SNPs with the highest tagging power
Average SNP call rates and reproducibility of > 99.9%, and low noise for copy number measurements
Detect many types and sizes of structural variation in the human genome that affect phenotypes, including duplications, deletions, amplifications, copy-neutral loss of heterozygosity (LOH), and mosaicism
Process up to 12 samples in parallel, increasing sample throughput and decreasing experimental variABIlity
Process samples using the single-tube, PCR-free Infinium HD Assay that requires only 200ng DNA per sample
Comprehensive data analysis with intuitive BlueFuse Multi Software streamlines copy number assessment and results reporting
The HumanCytoSNP-12 BeadChip is optimized to detect cytogenetic abnormalities most relevant to human disease.1-2 Content includes ~300,000 SNPs targeting regions shown to be important for cytogenetic analysis. The result is dense coverage of ~250 disease regions, including subtelomeric regions, pericentromeric regions, and sex chromosomes, commonly screened in cytogenetics labs. Sufficient SNP coverage is provided to determine dosage sensitivity of > 800 genes.
Specifications:
Assay Time 3 days
Hands-On Time 1 hour 5 min. for automated 8-beadchip workflow,6 hours 15 min. for manual 8-beadchip workflow
Input Quantity 200 ng DNA
Method Genome-Wide Genotyping Array,Cytogenomic Array
Technology Microarray
Variant Class Single Nucleotide Polymorphisms (SNPs),Loss of Heterozygosity (LOH),Chromosomal Abnormalities,Copy Number Variants (CNVs)
System Compatibility NextSeq 550,iScan
Species Category Human
Cancer Type Hematological,Solid Tumor"
"Illumina/TruSight Cardio Sequencing Kit for NextSeq (48 indexes, 48 samples, 4 enrichments)/FC-141-1011/1 Ea
" FC-141-1011 Illumina 產(chǎn)品編號: FC-141-1011美 元 價: $0.00會 員 價: 待定品 牌: Illumina產(chǎn) 地: 美國公 司: Illumina, Inc.產(chǎn)品分類: 其它>其它試劑>芯片公司分類: Clinical Research Products "Product Highlights:
Expertly defined genes selected in collaboration with the Imperial College of London
99% of the targeted regions covered at a depth of at least 20×*
Cost to sequence is ~ $1 US per gene; fully supported on Illumina sequencing and informatics platforms
The TruSight Cardio Kit uses next-generation sequencing (NGS) to provide comprehensive coverage of 174 genes with known associations to 17 ICCs, including cardiomyopathies, arrhythmias, aortopathies, and more. Genes were expertly selected with researchers at the National Heart and Lung Institute at the Imperial College of London. Content includes genes known to be associated with hereditary heart disease and emerging genes found in the literature.1
Specifications:
Input Quantity 50 ng DNA
System Compatibility MiSeq,NextSeq 550,MiSeqDx in Research Mode,MiniSeq,NextSeq 500
Variant Class Single Nucleotide Polymorphisms (SNPs),Germline Variants
Specialized Sample Types Low Input
Technology Sequencing
Species Category Human
Method Targeted DNA Sequencing"
"Illumina/MiSeq® Reagent Kit v3 - PGS/RH-102-1001/1 Ea
" RH-102-1001 Illumina 產(chǎn)品編號: RH-102-1001美 元 價: $0.00會 員 價: 待定品 牌: Illumina產(chǎn) 地: 美國公 司: Illumina, Inc.產(chǎn)品分類: 其它>其它試劑>芯片公司分類: Clinical Research Products "Product Highlights:
The VeriSeq PGS Kit takes advantage of next-generation sequencing (NGS) technology to provide comprehensive, accurate screening of all 24 chromosomes for selection of embryos most likely to be euploid. Preimplantation genetic screening (PGS) results generated using VeriSeq PGS are comparable to those achieved with the widely used array-based 24sure technology. In addition, NGS offers the opportunity for improved assay workflow, higher throughput, and enhanced performance.1
Industry-leADIng data quality: More than 90% of the world’s sequencing data is generated by Illumina sequencing by synthesis (SBS) chemistry*
Fast, streamlined workflow: Sample to answer in approximately 12 hours
High-throughput analysis: Screen up to 24 samples per run
Ultra-Low Input
NGS offers a highly sensitive method for screening embryos, requiring as little as 1 ng of DNA from a SurePlex DNA amplification reaction. DNA can be obtained from a blastomere biopsy, from a day 3 embryo, or from a trophectodermal (TE) biopsy from a blastocyst.
*Data calculations on file. Illumina, Inc., 2015.
Specifications:
Assay Time 11 hours
Hands-On Time 4 hours
Input Quantity 30 to 300 ng depending on QC results
System Compatibility MiSeq,MiSeqDx in Research Mode
Method PGS Sequencing
Technology Sequencing
Specialized Sample Types Single Cells
Species Category Human
Variant Class Chromosomal Abnormalities,Structural Variants,Copy Number Variants (CNVs)"
"Illumina/TruSight Cardio Sequencing Kit for MiSeq and MiSeqDx (12 indexes, 12 samples, 1 enrichment)/FC-141-1010/1 Ea
" FC-141-1010 Illumina 產(chǎn)品編號: FC-141-1010美 元 價: $0.00會 員 價: 待定品 牌: Illumina產(chǎn) 地: 美國公 司: Illumina, Inc.產(chǎn)品分類: 其它>其它試劑>芯片公司分類: Clinical Research Products "Product Highlights:
Expertly defined genes selected in collaboration with the Imperial College of London
99% of the targeted regions covered at a depth of at least 20×*
Cost to sequence is ~ $1 US per gene; fully supported on Illumina sequencing and informatics platforms
The TruSight Cardio Kit uses next-generation sequencing (NGS) to provide comprehensive coverage of 174 genes with known associations to 17 ICCs, including cardiomyopathies, arrhythmias, aortopathies, and more. Genes were expertly selected with researchers at the National Heart and Lung Institute at the Imperial College of London. Content includes genes known to be associated with hereditary heart disease and emerging genes found in the literature.1
Specifications:
Input Quantity 50 ng DNA
System Compatibility MiSeq,NextSeq 550,MiSeqDx in Research Mode,MiniSeq,NextSeq 500
Variant Class Single Nucleotide Polymorphisms (SNPs),Germline Variants
Specialized Sample Types Low Input
Technology Sequencing
Species Category Human
Method Targeted DNA Sequencing"
"Illumina/SureRef Pack (16 reference hybridizations)/PR-40-415205-PK/1 Ea
" PR-40-415205-PK Illumina 產(chǎn)品編號: PR-40-415205-PK美 元 價: $349.00會 員 價: 待定品 牌: Illumina產(chǎn) 地: 美國公 司: Illumina, Inc.產(chǎn)品分類: 其它>其它試劑>芯片公司分類: Clinical Research Products "Product Highlights:
Preimplantation genetic screening (PGS) with 24sure microarrays provides a comprehensive and accurate assessment of all 24 chromosomes from an embryo biopsy. The arrays can be used to screen for aneuploidy in first and second polar bodies, blastomere biopsies, and trophectoderm biopsies. The 24sure assay is objective, ensuring a high degree of confidence in the results and subsequent selection of embryos least likely to have aneuploidy for transfer.
Widely used, proven PGS – Method of choice for many of the world’s reference laboratories
Fast, reliable results – Comprehensive, accurate assessment of all 24 chromosomes in 12 hours
Straightforward workflow – Optimized protocols include minimal tube transfers, documented quality control (QC) stages, and flexIBLe stopping points
Straightforward Workflow Is Complete in 12 Hours
The straightforward 24sure protocol used standard laboratory techniques, providing a fast, accurate method for chromosome screening with minimal sensitivity to technical errors and designed to fit into existing workflows. Screening can be completed in 12 hours, and therefore does not interfere with tight schedules of a fresh IVF cycle.
Specifications:
Assay Time ~12 hours
Hands-On Time ~2.5 hours
Input Quantity Single cell or multi-cell samples
Technology Microarray
Specialized Sample Types Single Cells
Species Category Human
Variant Class Chromosomal Abnormalities,Structural Variants,Copy Number Variants (CNVs)
Method PGS Array
Significantly Higher Rate of Pregnancy May Be PossIBLe with PGS:
The pregnancy rate shown for embryos analyzed using preimplantation genetic screening and morphology is 69.1%, much higher than the 41.7% achieved using morphology screening alone.1 Pilot study of young, good prognosis patients (age < 35, first-time IVF, no history of prior miscarriage, n = 103).
PGS with 24sure Arrays Reduces the Effect of Maternal Age on Implantation and Pregnancy Rates:
Although aneuploidy risk increases with maternal age, PGS using 24sure arrays on either day 3 or day 5 embryos diminishes the effect of maternal age on implantation and pregnancy rates.2
24Sure Laboratory Workflow:
The 24sure laboratory workflow is a straightforward procedure that is completed in <12 hours.
BlueFuse Multi Software Delivers a Complete Data Analysis and Information Management System:
BlueFuse Multi Software provides a complete solution for analyzing, storing, and reporting 24sure results. A. Sample database displays experimental information. B. Array images imported directly from the scanner. C. Profiles for sample and reference chromosomes. D. Automated cycle reports."
"Illumina/HumanCytoSNP-12 v2.1 BeadChip Kit (48 samples)/WG-320-2103/1 Ea
" WG-320-2103 Illumina 產(chǎn)品編號: WG-320-2103美 元 價: $6960.00會 員 價: 待定品 牌: Illumina產(chǎn) 地: 美國公 司: Illumina, Inc.產(chǎn)品分類: 其它>其它試劑>芯片公司分類: Clinical Research Products "Product Highlights:
The 12-sample HumanCytoSNP-12 BeadChip is a powerful, whole-genome scanning panel designed for efficient, high-throughput analysis of genetic and structural variations that are most relevant to human disease. This scalable, proven solution offers substantially better resolution to detect smaller regions than fluorescence in situ hybridization (FISH) or comparative genomic hybridization (CGH).1
Complete panel of genome-wide tag single nucleotide polymorphisms (SNPs) and Markers targeting all regions of known cytogenetic importance, incorporating ~300,000 “best of the best” SNPs with the highest tagging power
Average SNP call rates and reproducibility of > 99.9%, and low noise for copy number measurements
Detect many types and sizes of structural variation in the human genome that affect phenotypes, including duplications, deletions, amplifications, copy-neutral loss of heterozygosity (LOH), and mosaicism
Process up to 12 samples in parallel, increasing sample throughput and decreasing experimental variABIlity
Process samples using the single-tube, PCR-free Infinium HD Assay that requires only 200ng DNA per sample
Comprehensive data analysis with intuitive BlueFuse Multi Software streamlines copy number assessment and results reporting
The HumanCytoSNP-12 BeadChip is optimized to detect cytogenetic abnormalities most relevant to human disease.1-2 Content includes ~300,000 SNPs targeting regions shown to be important for cytogenetic analysis. The result is dense coverage of ~250 disease regions, including subtelomeric regions, pericentromeric regions, and sex chromosomes, commonly screened in cytogenetics labs. Sufficient SNP coverage is provided to determine dosage sensitivity of > 800 genes.
Specifications:
Assay Time 3 days
Hands-On Time 1 hour 5 min. for automated 8-beadchip workflow,6 hours 15 min. for manual 8-beadchip workflow
Input Quantity 200 ng DNA
Method Genome-Wide Genotyping Array,Cytogenomic Array
Technology Microarray
Variant Class Single Nucleotide Polymorphisms (SNPs),Loss of Heterozygosity (LOH),Chromosomal Abnormalities,Copy Number Variants (CNVs)
System Compatibility NextSeq 550,iScan
Species Category Human
Cancer Type Hematological,Solid Tumor"
"Illumina/Ribo-Zero rRNA Removal Kit (Bacteria) 24 reactions 99% of rRNA from Gram-negative and Gram-positive bacterial R
" MRZB12424 Illumina 產(chǎn)品編號: MRZB12424美 元 價: $2066.00會 員 價: 待定品 牌: Illumina產(chǎn) 地: 美國公 司: Illumina, Inc.產(chǎn)品分類: 分子類>核酸提取純化>RNA提取純化試劑公司分類: Molecular Biology Reagents "Product Highlights:
Removes ribosomal RNA (rRNA) from intact and partially degraded mixtures of Gram (+) and Gram (–) bacteria in a single pass
Sequencing data contains complete transcriptome of coding and noncoding RNA species
Good for small sample quantities – only 1 μg of total RNA required
Virtually all rRNA is depleted from intact and partially degraded samples in 2 hours.
Sequencing is an important discovery tool for research into disease, development, and more. The sequencing data from samples treated with the Ribo-Zero rRNA Removal Kit (Bacteria) is focused on valuable RNA species, to facilitate discovery of relevant genes, splice variants and isoforms.
This kit offers informative sequencing results by removing unwanted cytoplasmic (nuclear-encoded) rRNA from bacterial mixtures prior to sequencing."
"Illumina/Globin-Zero Gold rRNA Removal Kit 6 reactions 99% of rRNA and >99% of globin mRNA from 1 µg - 5 µg of blood to
" GZG1206 Illumina 產(chǎn)品編號: GZG1206美 元 價: $567.00會 員 價: 待定品 牌: Illumina產(chǎn) 地: 美國公 司: Illumina, Inc.產(chǎn)品分類: 分子類>核酸提取純化>RNA提取純化試劑公司分類: Molecular Biology Reagents "Product Highlights:
Remove globin mRNA and ribosomal RNA (rRNA) in a single pass
Sequencing data contains complete transcriptome of coding and noncoding RNA species
Good for intact and partially degraded small sample quantities – only 1 μg of total RNA required
Blood is an important sample for research into thousands of rare diseases and other disorders. The sequencing data from samples treated with Globin-Zero are focused on valuable RNA species, to facilitate discovery of relevant genes, splice variants, and isoforms. Globin-Zero removes unwanted globin mRNA, as well as cytoplasmic and mitochondrial rRNA, from mammalian blood RNA samples before sequencing library construction.
Alternative kits
ScriptSeq Complete Gold Kit (Blood): Recommended for sequencing low input samples (e.g. 100 ng of total RNA)
Related information
rRNA Removal Kit Selection Guide
Ribo-Zero Kit Species Compatibility
Ribo-Zero Kit FAQs
Globin-Zero Gold removes globin mRNA, as well as rRNA from nuclear and mitochondrial regions:
Globin-Zero Gold depletes unwanted globin mRNA and ribosomal RNA from total RNA extracted from blood. Removal of these unwanted subunits produces sequencing results that are heavily focused on BIOLOGically informative genomic regions.
Globin-Zero Gold efficiently removes both globin mRNA and rRNA:
Removal of these unwanted subunits allows generation of sequencing libraries that produce data heavily focused on BIOLOGically informative genetic regions."
"Illumina/Ribo-Zero rRNA Removal Kit (Gram-Positive Bacteria) 6 reactions 99% of rRNA from 1-5 µg of Gram-positive bacter
" MRZGP126 Illumina 產(chǎn)品編號: MRZGP126美 元 價: $582.00會 員 價: 待定品 牌: Illumina產(chǎn) 地: 美國公 司: Illumina, Inc.產(chǎn)品分類: 分子類>核酸提取純化>RNA提取純化試劑公司分類: Molecular Biology Reagents "Product Highlights:
Removes ribosomal RNA (rRNA) from intact and partially degraded Gram (+) bacteria
Sequencing data contains complete transcriptome of coding and noncoding RNA species
Good for small sample quantities – only 1 μg of total RNA required
Nuclear rRNA removed: 23S, 16S, 5S
Sequencing is an important discovery tool for research into disease, development, and more. The sequencing data from samples treated with the Ribo-Zero rRNA Removal Kit (Gram-Positive Bacteria) are focused on valuable RNA species, to facilitate discovery of relevant genes, splice variants, and isoforms.
The Ribo-Zero rRNA Removal Kit (Gram-Positive Bacteria) offers informative sequencing results by removing unwanted rRNA prior to sequencing. The kit removes rRNA from both intact and partially degraded samples.
Removes all major rRNA subunits
The Ribo-Zero rRNA Removal Kit (Gram-Positive Bacteria) depletes unwanted rRNA from total RNA. Removal of these unwanted subunits produces sequencing results that are heavily focused on BIOLOGically informative genomic regions."
"Illumina/Ribo-Zero Gold rRNA Removal Kit (Epidemiology) 6 reactions/MRZE706/1 Ea
" MRZE706 Illumina 產(chǎn)品編號: MRZE706美 元 價: $582.00會 員 價: 待定品 牌: Illumina產(chǎn) 地: 美國公 司: Illumina, Inc.產(chǎn)品分類: 分子類>核酸提取純化>RNA提取純化試劑公司分類: Molecular Biology Reagents "Product Highlights:
Removes cytoplasmic and mitochondrial ribosomal RNA (rRNA) from samples composed of human/mouse/rat, Gram-positive and Gram-negative bacterial RNA (see table)
Requires 500 ng to 2.5 μg total RNA per sample
rRNA removal from both intact and partially degraded RNA
Single-pass, 90- to 120-minute process
Recovers all fragments of human and bacterial non-ribosomal RNAs
Applicable to a broad spectrum of bacteria
The Ribo-Zero Gold rRNA Removal Kit (Epidemiology) combines Ribo-Zero Gold (Human/Mouse/Rat) and Ribo-Zero (Bacteria) rRNA removal reagents into a single solution that effectively removes rRNA, including human mitochondrial RNA, from samples composed of both human/mouse/rat and bacterial RNA.
Hypothesis-free NGS is more sensitive to diversity than 16S profiling
Ribo-Zero Gold rRNA Removal Kit (Epidemiology) has increased sensitivity to BIOLOGical diversity because it captures all metatranscriptomic information (instead of directed capture with 16S profiling).
Overview of the Ribo-Zero process
Virtually all rRNA is depleted in 2 hours.
Step 1: Wash the magnetic beads
Step 2: Treat samples with rRNA Removal Solution
Step 3: Remove rRNA
Step 4: Purify rRNA-depleted samples, and proceed with library preparation
Related Information
rRNA Removal Kit Selection Guide
Ribo-Zero Kit Species Compatibility
Ribo-Zero Kit FAQs
Specifications:
Technology Sequencing
Species Category Human,Mouse,Rat,Bacteria
Specialized Sample Types FFPE
System Compatibility Genome Analyzer IIx,HiSeq 2000,MiSeq,NextSeq 550,HiSeq 3000,HiSeq 1000,HiSeq 1500,NextSeq 500,HiSeq 2500,HiSeq 4000"
"Illumina/Ribo-Zero rRNA Removal Kit (Plant Leaf) 6 reactions/MRZPL116/1 Ea
" MRZPL116 Illumina 產(chǎn)品編號: MRZPL116美 元 價: $582.00會 員 價: 待定品 牌: Illumina產(chǎn) 地: 美國公 司: Illumina, Inc.產(chǎn)品分類: 分子類>核酸提取純化>RNA提取純化試劑公司分類: Molecular Biology Reagents "Product Highlights:
Removes cytoplasmic, mitochondrial, and chloroplast ribosomal RNA (rRNA) in a single pass
Sequencing data contains complete transcriptome of coding and noncoding RNA species
Good for intact and partially degraded small sample quantities – only 1 μg of total RNA required
Virtually all rRNA is depleted from intact and partially degraded samples in 2 hours.
Sequencing is an important discovery tool for plant research. The sequencing data from samples treated with Ribo-Zero (Plant Leaf) and Ribo-Zero (Plant Seed/Root) is focused on valuable RNA species, to facilitate discovery of relevant genes, splice variants, and isoforms.
Ribo-Zero (Plant Leaf) and Ribo-Zero (Plant Seed/Root) offer informative sequencing results by removing unwanted cytoplasmic, mitochondrial, and chloroplast rRNA prior to sequencing. In order to achieve maximum depletion of rRNA, the Ribo-Zero (Plant Leaf) kit contains a higher percentage of probes to deplete chloroplast rRNA compared to Ribo-Zero (Plant Seed/Root).
Overview of the Ribo-Zero process
Virtually all rRNA is depleted in 2 hours.
Step 1: Wash the magnetic beads
Step 2: Treat samples with rRNA Removal Solution
Step 3: Remove rRNA
Step 4: Purify rRNA-depleted samples, and proceed with library preparation
Alternative kits
ScriptSeq Complete Kit (Plant): Recommended for low input plant samples (e.g. 100 ng of total RNA).
Related information
rRNA Removal Kit Selection Guide
Ribo-Zero Kit Species Compatibility
Ribo-Zero Kit FAQs"
"Illumina/Ribo-Zero rRNA Removal Kit (Gram-Negative Bacteria) 6 reactions 99% of rRNA from 1- 5 µg of Gram-negative bacte
" MRZGN126 Illumina 產(chǎn)品編號: MRZGN126美 元 價: $582.00會 員 價: 待定品 牌: Illumina產(chǎn) 地: 美國公 司: Illumina, Inc.產(chǎn)品分類: 分子類>核酸提取純化>RNA提取純化試劑公司分類: Molecular Biology Reagents "Product Highlights:
Remove ribosomal RNA (rRNA) from intact and partially degraded Gram (-) bacteria
Sequencing data contain complete transcriptome of coding and noncoding RNA species
Good for small sample quantities – only 1 μg of total RNA required
Nuclear rRNA removed: 23S, 16S, 5S
Sequencing is an important discovery tool for research into disease, development, and more. The sequencing data from samples treated with the Ribo-Zero rRNA Removal Kit (Gram-Negative Bacteria) are focused on valuable RNA species, to facilitate discovery of relevant genes, splice variants, and isoforms.
The Ribo-Zero rRNA Removal Kit (Gram-Negative Bacteria) offers informative sequencing results by removing unwanted rRNA prior to sequencing. The kit removes rRNA from intact and partially degraded samples.
Removes all major rRNA subunits
The Ribo-Zero rRNA Removal Kit (Gram-Negative Bacteria) depletes unwanted rRNA from total RNA. Removal of these unwanted subunits produces sequencing results that are heavily focused on BIOLOGically informative genomic regions."
"Illumina/Globin-Zero Gold rRNA Removal Kit 24 reactions 99% of rRNA and >99% of globin mRNA from 1 µg - 5 µg of blood t
" GZG1224 Illumina 產(chǎn)品編號: GZG1224美 元 價: $2016.00會 員 價: 待定品 牌: Illumina產(chǎn) 地: 美國公 司: Illumina, Inc.產(chǎn)品分類: 分子類>核酸提取純化>RNA提取純化試劑公司分類: Molecular Biology Reagents "Product Highlights:
Remove globin mRNA and ribosomal RNA (rRNA) in a single pass
Sequencing data contains complete transcriptome of coding and noncoding RNA species
Good for intact and partially degraded small sample quantities – only 1 μg of total RNA required
Blood is an important sample for research into thousands of rare diseases and other disorders. The sequencing data from samples treated with Globin-Zero are focused on valuable RNA species, to facilitate discovery of relevant genes, splice variants, and isoforms. Globin-Zero removes unwanted globin mRNA, as well as cytoplasmic and mitochondrial rRNA, from mammalian blood RNA samples before sequencing library construction.
Alternative kits
ScriptSeq Complete Gold Kit (Blood): Recommended for sequencing low input samples (e.g. 100 ng of total RNA)
Related information
rRNA Removal Kit Selection Guide
Ribo-Zero Kit Species Compatibility
Ribo-Zero Kit FAQs
Globin-Zero Gold removes globin mRNA, as well as rRNA from nuclear and mitochondrial regions:
Globin-Zero Gold depletes unwanted globin mRNA and ribosomal RNA from total RNA extracted from blood. Removal of these unwanted subunits produces sequencing results that are heavily focused on BIOLOGically informative genomic regions.
Globin-Zero Gold efficiently removes both globin mRNA and rRNA:
Removal of these unwanted subunits allows generation of sequencing libraries that produce data heavily focused on BIOLOGically informative genetic regions."
"Illumina/Ribo-Zero Gold rRNA Removal Kit (Yeast) 24 reactions/MRZY1324/1 Ea
" MRZY1324 Illumina 產(chǎn)品編號: MRZY1324美 元 價: $2016.00會 員 價: 待定品 牌: Illumina產(chǎn) 地: 美國公 司: Illumina, Inc.產(chǎn)品分類: 分子類>核酸提取純化>RNA提取純化試劑公司分類: Molecular Biology Reagents "Product Highlights:
Depletes ribosomal RNA (rRNA)
Sequencing results contain entire transcriptome of coding and noncoding RNA species
Good for intact and partially degraded small samples – only 1 μg of total RNA required
The yeast transcriptome is more complex than previously thought. RNA-Seq of yeast is a valuable approach for mapping the transcriptome to characterize novel and low abundance transcripts. The Ribo-Zero Gold rRNA Removal Kit (Yeast) offers informative sequencing results by removing unwanted rRNA before sequencing.
Gene coverage is enhanced following depletion by Ribo-Zero Gold (Yeast). Subsequent library construction and sequencing produces reads focused on informative genomic regions."
"Illumina/Ribo-Zero rRNA Removal Kit (Plant Leaf) 24 reactions 99% of nuclear-encoded and chloroplast rRNA from 1-5 µg of
" MRZPL1224 Illumina 產(chǎn)品編號: MRZPL1224美 元 價: $2066.00會 員 價: 待定品 牌: Illumina產(chǎn) 地: 美國公 司: Illumina, Inc.產(chǎn)品分類: 分子類>核酸提取純化>RNA提取純化試劑公司分類: Molecular Biology Reagents "Product Highlights:
Removes cytoplasmic, mitochondrial, and chloroplast ribosomal RNA (rRNA) in a single pass
Sequencing data contains complete transcriptome of coding and noncoding RNA species
Good for intact and partially degraded small sample quantities – only 1 μg of total RNA required
Virtually all rRNA is depleted from intact and partially degraded samples in 2 hours.
Sequencing is an important discovery tool for plant research. The sequencing data from samples treated with Ribo-Zero (Plant Leaf) and Ribo-Zero (Plant Seed/Root) is focused on valuable RNA species, to facilitate discovery of relevant genes, splice variants, and isoforms.
Ribo-Zero (Plant Leaf) and Ribo-Zero (Plant Seed/Root) offer informative sequencing results by removing unwanted cytoplasmic, mitochondrial, and chloroplast rRNA prior to sequencing. In order to achieve maximum depletion of rRNA, the Ribo-Zero (Plant Leaf) kit contains a higher percentage of probes to deplete chloroplast rRNA compared to Ribo-Zero (Plant Seed/Root).
Overview of the Ribo-Zero process
Virtually all rRNA is depleted in 2 hours.
Step 1: Wash the magnetic beads
Step 2: Treat samples with rRNA Removal Solution
Step 3: Remove rRNA
Step 4: Purify rRNA-depleted samples, and proceed with library preparation
Alternative kits
ScriptSeq Complete Kit (Plant): Recommended for low input plant samples (e.g. 100 ng of total RNA).
Related information
rRNA Removal Kit Selection Guide
Ribo-Zero Kit Species Compatibility
Ribo-Zero Kit FAQs"
"Illumina/rRNA Removal Kit (Epidemiology) 24 reactions/MRZE724/1 Ea
" MRZE724 Illumina 產(chǎn)品編號: MRZE724美 元 價: $2066.00會 員 價: 待定品 牌: Illumina產(chǎn) 地: 美國公 司: Illumina, Inc.產(chǎn)品分類: 分子類>核酸提取純化>RNA提取純化試劑公司分類: Molecular Biology Reagents "Product Highlights:
Removes cytoplasmic and mitochondrial ribosomal RNA (rRNA) from samples composed of human/mouse/rat, Gram-positive and Gram-negative bacterial RNA (see table)
Requires 500 ng to 2.5 μg total RNA per sample
rRNA removal from both intact and partially degraded RNA
Single-pass, 90- to 120-minute process
Recovers all fragments of human and bacterial non-ribosomal RNAs
Applicable to a broad spectrum of bacteria
The Ribo-Zero Gold rRNA Removal Kit (Epidemiology) combines Ribo-Zero Gold (Human/Mouse/Rat) and Ribo-Zero (Bacteria) rRNA removal reagents into a single solution that effectively removes rRNA, including human mitochondrial RNA, from samples composed of both human/mouse/rat and bacterial RNA.
Hypothesis-free NGS is more sensitive to diversity than 16S profiling
Ribo-Zero Gold rRNA Removal Kit (Epidemiology) has increased sensitivity to BIOLOGical diversity because it captures all metatranscriptomic information (instead of directed capture with 16S profiling).
Overview of the Ribo-Zero process
Virtually all rRNA is depleted in 2 hours.
Step 1: Wash the magnetic beads
Step 2: Treat samples with rRNA Removal Solution
Step 3: Remove rRNA
Step 4: Purify rRNA-depleted samples, and proceed with library preparation
Related Information
rRNA Removal Kit Selection Guide
Ribo-Zero Kit Species Compatibility
Ribo-Zero Kit FAQs
Specifications:
Technology Sequencing
Species Category Human,Mouse,Rat,Bacteria
Specialized Sample Types FFPE
System Compatibility Genome Analyzer IIx,HiSeq 2000,MiSeq,NextSeq 550,HiSeq 3000,HiSeq 1000,HiSeq 1500,NextSeq 500,HiSeq 2500,HiSeq 4000"
"Illumina/Ribo-Zero rRNA Removal Kit (H/M/R) 6 reactions/MRZH116/1 Ea
" MRZH116 Illumina 產(chǎn)品編號: MRZH116美 元 價: $582.00會 員 價: 待定品 牌: Illumina產(chǎn) 地: 美國公 司: Illumina, Inc.產(chǎn)品分類: 分子類>核酸提取純化>RNA提取純化試劑公司分類: Ribo-Zero rRNA Removal Kit (Human "Product Highlights:
Removes ribosomal RNA (rRNA) in a single pass
Sequencing data contains complete transcriptome of coding and noncoding RNA species
Good for intact and partially degraded small samples – only 1 μg of total RNA required
Sequencing is an important discovery tool for research into disease, development, and more. The sequencing data from samples treated with Ribo-Zero (Human/Mouse/Rat) is focused on valuable RNA species, to facilitate discovery of relevant genes, splice variants and isoforms.
Ribo-Zero (Human/Mouse/Rat) offers informative sequencing results by removing unwanted rRNA prior to sequencing. This kit removes cytoplasmic (nuclear-encoded) rRNAs.
Ribo-Zero retains the complete transcriptome
Ribo-Zero removes rRNA in order to retain the regulatory regions of noncoding RNA, even from low-quality samples. Other methods, such as Poly(A) depletion, do not retain noncoding, regulatory information.
Overview of the Ribo-Zero process
Virtually all rRNA is depleted from intact, degraded, and badly degraded (FFPE) samples in 2 hours.
Step 1: Wash the magnetic beads
Step 2: Treat samples with rRNA Removal Solution
Step 3: Remove rRNA
Step 4: Purify rRNA-depleted samples, and proceed with library preparation
Alternative kit versions
The Ribo-Zero Gold (Human/Mouse/Rat) rRNA Removal Kit removes both cytoplasmic and mitochondrial rRNAs, and is compatIBLe with low input samples (e.g. 100 ng of total RNA).
Related information
rRNA Removal Kit Selection Guide
Ribo-Zero Kit Species Compatibility
Ribo-Zero Kit FAQs"
"Illumina/Ribo-Zero Gold rRNA Removal Kit (H/M/R) (24 reactions) 99% of cytoplasmic and mitochondrial rRNA from human, mo
" MRZG12324 Illumina 產(chǎn)品編號: MRZG12324美 元 價: $2066.00會 員 價: 待定品 牌: Illumina產(chǎn) 地: 美國公 司: Illumina, Inc.產(chǎn)品分類: 分子類>核酸提取純化>RNA提取純化試劑公司分類: Ribo-Zero Gold rRNA Removal Kit (Human "Product Highlights:
Removes ribosomal RNA (rRNA) in a single pass
Sequencing data contains complete transcriptome of coding and noncoding RNA species
Good for intact and partially degraded small sample quantities – only 1 μg of total RNA required
Sequencing is an important discovery tool for research into disease, development, and more. The sequencing data from samples treated with Ribo-Zero Gold (Human/Mouse/Rat) is focused on valuable RNA species, to facilitate discovery of relevant genes, splice variants, and isoforms.
Ribo-Zero Gold (Human/Mouse/Rat) offers informative sequencing results by removing unwanted rRNA prior to sequencing. This kit removes both cytoplasmic (nuclear-encoded) and mitochondrial rRNAs.
Ribo-Zero retains the complete transcriptome
Ribo-Zero removes rRNA in order to retain the regulatory regions of noncoding RNA, even from low-quality samples. Other methods, such as Poly(A) depletion, do not retain noncoding, regulatory information.
Overview of the Ribo-Zero process
Virtually all rRNA is depleted from intact, degraded, and badly degraded (FFPE) samples in 2 hours.
Step 1: Wash the magnetic beads
Step 2: Treat samples with rRNA Removal Solution
Step 3: Remove rRNA
Step 4: Purify rRNA-depleted samples, and proceed with library preparation
Alternative kits
Ribo-Zero rRNA Removal Kit (Human/Mouse/Rat): Removes cytoplasmic rRNA only.
Related information
rRNA Removal Kit Selection Guide
Ribo-Zero Kit Species Compatibility
Ribo-Zero Kit FAQs"
"Illumina/Ribo-Zero rRNA Removal Kit (Plant Seed/Root) 6 reactions/MRZSR116/1 Ea
" MRZSR116 Illumina 產(chǎn)品編號: MRZSR116美 元 價: $582.00會 員 價: 待定品 牌: Illumina產(chǎn) 地: 美國公 司: Illumina, Inc.產(chǎn)品分類: 分子類>核酸提取純化>RNA提取純化試劑公司分類: Molecular Biology Reagents "Product Highlights:
Removes cytoplasmic, mitochondrial, and chloroplast ribosomal RNA (rRNA) in a single pass
Sequencing data contains complete transcriptome of coding and noncoding RNA species
Good for intact and partially degraded small sample quantities – only 1 μg of total RNA required
Virtually all rRNA is depleted from intact and partially degraded samples in 2 hours.
Sequencing is an important discovery tool for plant research. The sequencing data from samples treated with Ribo-Zero (Plant Leaf) and Ribo-Zero (Plant Seed/Root) is focused on valuable RNA species, to facilitate discovery of relevant genes, splice variants, and isoforms.
Ribo-Zero (Plant Leaf) and Ribo-Zero (Plant Seed/Root) offer informative sequencing results by removing unwanted cytoplasmic, mitochondrial, and chloroplast rRNA prior to sequencing. In order to achieve maximum depletion of rRNA, the Ribo-Zero (Plant Leaf) kit contains a higher percentage of probes to deplete chloroplast rRNA compared to Ribo-Zero (Plant Seed/Root).
Overview of the Ribo-Zero process
Virtually all rRNA is depleted in 2 hours.
Step 1: Wash the magnetic beads
Step 2: Treat samples with rRNA Removal Solution
Step 3: Remove rRNA
Step 4: Purify rRNA-depleted samples, and proceed with library preparation
Alternative kits
ScriptSeq Complete Kit (Plant): Recommended for low input plant samples (e.g. 100 ng of total RNA).
Related information
rRNA Removal Kit Selection Guide
Ribo-Zero Kit Species Compatibility
Ribo-Zero Kit FAQs"
"Illumina/Ribo-Zero rRNA Removal Kit (H/M/R) 24 reactions/MRZH11124/1 Ea
" MRZH11124 Illumina 產(chǎn)品編號: MRZH11124美 元 價: $2066.00會 員 價: 待定品 牌: Illumina產(chǎn) 地: 美國公 司: Illumina, Inc.產(chǎn)品分類: 分子類>核酸提取純化>RNA提取純化試劑公司分類: Ribo-Zero rRNA Removal Kit (Human "Product Highlights:
Removes ribosomal RNA (rRNA) in a single pass
Sequencing data contains complete transcriptome of coding and noncoding RNA species
Good for intact and partially degraded small samples – only 1 μg of total RNA required
Sequencing is an important discovery tool for research into disease, development, and more. The sequencing data from samples treated with Ribo-Zero (Human/Mouse/Rat) is focused on valuable RNA species, to facilitate discovery of relevant genes, splice variants and isoforms.
Ribo-Zero (Human/Mouse/Rat) offers informative sequencing results by removing unwanted rRNA prior to sequencing. This kit removes cytoplasmic (nuclear-encoded) rRNAs.
Ribo-Zero retains the complete transcriptome
Ribo-Zero removes rRNA in order to retain the regulatory regions of noncoding RNA, even from low-quality samples. Other methods, such as Poly(A) depletion, do not retain noncoding, regulatory information.
Overview of the Ribo-Zero process
Virtually all rRNA is depleted from intact, degraded, and badly degraded (FFPE) samples in 2 hours.
Step 1: Wash the magnetic beads
Step 2: Treat samples with rRNA Removal Solution
Step 3: Remove rRNA
Step 4: Purify rRNA-depleted samples, and proceed with library preparation
Alternative kit versions
The Ribo-Zero Gold (Human/Mouse/Rat) rRNA Removal Kit removes both cytoplasmic and mitochondrial rRNAs, and is compatIBLe with low input samples (e.g. 100 ng of total RNA).
Related information
rRNA Removal Kit Selection Guide
Ribo-Zero Kit Species Compatibility
Ribo-Zero Kit FAQs"
"Illumina/Ribo-Zero Gold rRNA Removal Kit (H/M/R) (6 reactions)/MRZG126/1 Ea
" MRZG126 Illumina 產(chǎn)品編號: MRZG126美 元 價: $582.00會 員 價: 待定品 牌: Illumina產(chǎn) 地: 美國公 司: Illumina, Inc.產(chǎn)品分類: 分子類>核酸提取純化>RNA提取純化試劑公司分類: Ribo-Zero Gold rRNA Removal Kit (Human "Product Highlights:
Removes ribosomal RNA (rRNA) in a single pass
Sequencing data contains complete transcriptome of coding and noncoding RNA species
Good for intact and partially degraded small sample quantities – only 1 μg of total RNA required
Sequencing is an important discovery tool for research into disease, development, and more. The sequencing data from samples treated with Ribo-Zero Gold (Human/Mouse/Rat) is focused on valuable RNA species, to facilitate discovery of relevant genes, splice variants, and isoforms.
Ribo-Zero Gold (Human/Mouse/Rat) offers informative sequencing results by removing unwanted rRNA prior to sequencing. This kit removes both cytoplasmic (nuclear-encoded) and mitochondrial rRNAs.
Ribo-Zero retains the complete transcriptome
Ribo-Zero removes rRNA in order to retain the regulatory regions of noncoding RNA, even from low-quality samples. Other methods, such as Poly(A) depletion, do not retain noncoding, regulatory information.
Overview of the Ribo-Zero process
Virtually all rRNA is depleted from intact, degraded, and badly degraded (FFPE) samples in 2 hours.
Step 1: Wash the magnetic beads
Step 2: Treat samples with rRNA Removal Solution
Step 3: Remove rRNA
Step 4: Purify rRNA-depleted samples, and proceed with library preparation
Alternative kits
Ribo-Zero rRNA Removal Kit (Human/Mouse/Rat): Removes cytoplasmic rRNA only.
Related information
rRNA Removal Kit Selection Guide
Ribo-Zero Kit Species Compatibility
Ribo-Zero Kit FAQs
Specifications:
Technology Sequencing
Specialized Sample Types FFPE
Species Category Human,Mouse,Rat
System Compatibility MiSeq,Genome Analyzer IIx,HiSeq 2000,NextSeq 550,HiSeq 3000,HiSeq 1000,HiSeq 1500,NextSeq 500,HiSeq 2500,HiSeq 4000"
"Illumina/Ribo-Zero rRNA Removal Kit (Bacteria) 6 reactions/MRZMB126/1 Ea
" MRZMB126 Illumina 產(chǎn)品編號: MRZMB126美 元 價: $582.00會 員 價: 待定品 牌: Illumina產(chǎn) 地: 美國公 司: Illumina, Inc.產(chǎn)品分類: 分子類>核酸提取純化>RNA提取純化試劑公司分類: Molecular Biology Reagents "Product Highlights:
Removes ribosomal RNA (rRNA) from intact and partially degraded mixtures of Gram (+) and Gram (–) bacteria in a single pass
Sequencing data contains complete transcriptome of coding and noncoding RNA species
Good for small sample quantities – only 1 μg of total RNA required
Virtually all rRNA is depleted from intact and partially degraded samples in 2 hours.
Sequencing is an important discovery tool for research into disease, development, and more. The sequencing data from samples treated with the Ribo-Zero rRNA Removal Kit (Bacteria) is focused on valuable RNA species, to facilitate discovery of relevant genes, splice variants and isoforms.
This kit offers informative sequencing results by removing unwanted cytoplasmic (nuclear-encoded) rRNA from bacterial mixtures prior to sequencing.
Overview of the Ribo-Zero process
Virtually all rRNA is depleted in 2 hours.
Step 1: Wash the magnetic beads
Step 2: Treat samples with rRNA Removal Solution
Step 3: Remove rRNA
Step 4: Purify rRNA-depleted samples, and proceed with library preparation
Alternative kits
ScriptSeq Complete Kit (Bacteria): Recommended for sequencing low input samples (e.g. 100 ng of total RNA).
Related information
rRNA Removal Kit Selection Guide
Ribo-Zero Kit Species Compatibility
Ribo-Zero Kit FAQs"
"Illumina/Ribo-Zero Gold rRNA Removal Kit (Yeast) 6 reactions/MRZY1306/1 Ea
" MRZY1306 Illumina 產(chǎn)品編號: MRZY1306美 元 價: $567.00會 員 價: 待定品 牌: Illumina產(chǎn) 地: 美國公 司: Illumina, Inc.產(chǎn)品分類: 分子類>核酸提取純化>RNA提取純化試劑公司分類: Molecular Biology Reagents "Product Highlights:
Depletes ribosomal RNA (rRNA)
Sequencing results contain entire transcriptome of coding and noncoding RNA species
Good for intact and partially degraded small samples – only 1 μg of total RNA required
The yeast transcriptome is more complex than previously thought. RNA-Seq of yeast is a valuable approach for mapping the transcriptome to characterize novel and low abundance transcripts. The Ribo-Zero Gold rRNA Removal Kit (Yeast) offers informative sequencing results by removing unwanted rRNA before sequencing.
Gene coverage is enhanced following depletion by Ribo-Zero Gold (Yeast). Subsequent library construction and sequencing produces reads focused on informative genomic regions."
Illumina
"Illumina/Tip Depth Gauge/A1-99-102/1 Ea
" A1-99-102 Illumina 產(chǎn)品編號: A1-99-102美 元 價: $150.00會 員 價: 待定品 牌: Illumina產(chǎn) 地: 美國公 司: Illumina, Inc.產(chǎn)品分類: 其它>配件>常用設(shè)備公司分類: Accessory Products "Product Highlights:
The Tip Depth Gauge calibrates the probe depth for the Tecan Genesis Freedom EVO or Freedom EVO-2 liquid-handling robot used during automation of array-based assays such as the Infinium Assay."
"Illumina/Infinium Te-Flow Thermometer Assembly/A1-99-109/1 Ea
" A1-99-109 Illumina 產(chǎn)品編號: A1-99-109美 元 價: $680.00會 員 價: 待定品 牌: Illumina產(chǎn) 地: 美國公 司: Illumina, Inc.產(chǎn)品分類: 其它>配件>常用設(shè)備公司分類: Accessory Products "Product Highlights:
The Infinium TeFlow Thermometer Assembly, which includes the Thermometer and a temperature probe, reads the temperature in the TeFlow rack during Infinium Whole-Genome Genotyping Assays and Infinium HD Assays."
"Illumina/Infinium Multi-Sample Alignment Fixture (1)/WG-15-310/1 Ea
" WG-15-310 Illumina 產(chǎn)品編號: WG-15-310美 元 價: $650.00會 員 價: 待定品 牌: Illumina產(chǎn) 地: 美國公 司: Illumina, Inc.產(chǎn)品分類: 其它>配件>常用設(shè)備公司分類: Accessory Products "Product Highlights:
The Infinium Alignment Fixture allows correct assembly of the TeFlow Chamber, HD or LCG BeadChip array, and spacer to ensure optimal processing during the Infinium Assay."
Illumina
"Illumina/cBot 2 Barcoded Strip Tubes (8 well)/20005160/1 Ea
" 20005160 Illumina 產(chǎn)品編號: 20005160美 元 價: $500.00會 員 價: 待定品 牌: Illumina產(chǎn) 地: 美國公 司: Illumina, Inc.產(chǎn)品分類: 其它>配件>常用設(shè)備公司分類: Accessory Products "Product Highlights:
The cBot 2 barcoded 8-well strip tube enables sample tracking though the sequencing workflow. The keyed strip tube minimizes sample mix-ups by single orientation loADIng and a unique barcode that is read by an onboard barcode scanner on the cBot 2 System.
Each strip tube has two barcodes enabling sample tracking on liquid handling robots and the cBot 2 System. Each strip tube box contains 100 strip tubes.
This item is an accessory for the cBot 2 System, which automates cluster generation on HiSeq sequencing systems.
Specifications:
Technology Sequencing
System Compatibility HiSeq 4000,HiSeq X Ten,HiScanSQ,HiSeq 3000,HiSeq X Five,HiSeq 2500"
"Illumina/Infinium MIDI Heatblock Insert/BD-60-601/1 Ea
" BD-60-601 Illumina 產(chǎn)品編號: BD-60-601美 元 價: $160.00會 員 價: 待定品 牌: Illumina產(chǎn) 地: 美國公 司: Illumina, Inc.產(chǎn)品分類: 其它>配件>常用設(shè)備公司分類: Accessory Products
"Illumina/Infinium BeadChip Glass Tray (1)/BD-60-460/1 Ea
" BD-60-460 Illumina 產(chǎn)品編號: BD-60-460美 元 價: $62.00會 員 價: 待定品 牌: Illumina產(chǎn) 地: 美國公 司: Illumina, Inc.產(chǎn)品分類: 其它>配件>常用設(shè)備公司分類: Accessory Products "Product Highlights:
The BeadChip Wash Rack and Glass Tray (purchased separately) are used to handle BeadChip arrays following hybridization during Direct Hybridization and Infinium Assays."
"Illumina/Infinium Hybridization Chamber Inserts (8)/WG-15-301/1 Ea
" WG-15-301 Illumina 產(chǎn)品編號: WG-15-301美 元 價: $1200.00會 員 價: 待定品 牌: Illumina產(chǎn) 地: 美國公 司: Illumina, Inc.產(chǎn)品分類: 其它>配件>常用設(shè)備公司分類: Accessory Products
"Illumina/Infinium Hybridization Chamber Inserts (8)/WG-15-301/1 Ea
" WG-15-301 Illumina 產(chǎn)品編號: WG-15-301美 元 價: $1200.00會 員 價: 待定品 牌: Illumina產(chǎn) 地: 美國公 司: Illumina, Inc.產(chǎn)品分類: 其它>配件>常用設(shè)備公司分類: Accessory Products "Product Highlights:
The Infinium Hybridization Chambers are used for BeadChip array hybridization during Infinium Assays. Each Infinium Hybridization Chamber processes four Infinium BeadChip arrays per day.
A gasket fits inside the chamber to ensure proper BeadChip retention and optimal exposure to reagents. One gasket is included in the package, and replacement gaskets are available for purchase separately."
"Illumina/Replacement Infinium Hybridization Chamber Gasket (1)/BD-60-403/1 Ea
" BD-60-403 Illumina 產(chǎn)品編號: BD-60-403美 元 價: $7.00會 員 價: 待定品 牌: Illumina產(chǎn) 地: 美國公 司: Illumina, Inc.產(chǎn)品分類: 其它>配件>常用設(shè)備公司分類: Accessory Products "Product Highlights:
The Infinium Hybridization Chambers are used for BeadChip array hybridization during Infinium Assays. Each Infinium Hybridization Chamber processes four Infinium BeadChip arrays per day.
A gasket fits inside the chamber to ensure proper BeadChip retention and optimal exposure to reagents. One gasket is included in the package, and replacement gaskets are available for purchase separately."
"Illumina/Infinium Hybridization Chamber (1)/BD-60-402/1 Ea
" BD-60-402 Illumina 產(chǎn)品編號: BD-60-402美 元 價: $840.00會 員 價: 待定品 牌: Illumina產(chǎn) 地: 美國公 司: Illumina, Inc.產(chǎn)品分類: 其它>配件>常用設(shè)備公司分類: Accessory Products "Product Highlights:
The Infinium Hybridization Chambers are used for BeadChip array hybridization during Infinium Assays. Each Infinium Hybridization Chamber processes four Infinium BeadChip arrays per day.
A gasket fits inside the chamber to ensure proper BeadChip retention and optimal exposure to reagents. One gasket is included in the package, and replacement gaskets are available for purchase separately."
"Illumina/Infinium BeadChip Boxes (10)/BD-60-500/1 Ea
" BD-60-500 Illumina 產(chǎn)品編號: BD-60-500美 元 價: $40.00會 員 價: 待定品 牌: Illumina產(chǎn) 地: 美國公 司: Illumina, Inc.產(chǎn)品分類: 其它>配件>常用設(shè)備公司分類: Accessory Products "Product Highlights:
Store BeadChips used in Illumina array-based assays. Each BeadChip storage box holds 25 BeadChips."
"Illumina/Infinium BeadChip Expansion Package/WG-10-201/1 Ea
" WG-10-201 Illumina 產(chǎn)品編號: WG-10-201美 元 價: $7000.00會 員 價: 待定品 牌: Illumina產(chǎn) 地: 美國公 司: Illumina, Inc.產(chǎn)品分類: 其它>配件>常用設(shè)備公司分類: Accessory Products "Product Highlights:
Store BeadChips used in Illumina array-based assays. Each BeadChip storage box holds 25 BeadChips."
"Illumina/Teflon-coated replacement probes for Tecan Robot (1)/A1-99-101/1 Ea
" A1-99-101 Illumina 產(chǎn)品編號: A1-99-101美 元 價: $70.00會 員 價: 待定品 牌: Illumina產(chǎn) 地: 美國公 司: Illumina, Inc.產(chǎn)品分類: 其它>配件>常用設(shè)備公司分類: Accessory Products "Product Highlights:
Store BeadChips used in Illumina array-based assays. Each BeadChip storage box holds 25 BeadChips."
Illumina
"Illumina/MiSeqDx Cystic Fibrosis 139-Variant Assay (20 runs, 960 samples)/DX-102-1003/1 Ea
" DX-102-1003 Illumina 產(chǎn)品編號: DX-102-1003美 元 價: $0.00會 員 價: 待定品 牌: Illumina產(chǎn) 地: 美國公 司: Illumina, Inc.產(chǎn)品分類: 其它>其它試劑>臨床研究公司分類: In Vitro Diagnostic (IVD) Products "Product Highlights:
Compared to the current ACMG recommended cystic fibrosis variant panel, the MiSeqDx Cystic Fibrosis 139-Variant Assay offers:
Improved Detection Rates of Cystic Fibrosis-Causing Variants
Detection of couples at risk increased from 72% to ~91%1
Reduced Additional Testing
Highly accurate and reproducIBLe sequencing technology delivers dependable results
The MiSeqDx Cystic Fibrosis 139-Variant Assay is an FDA-cleared in vitro diagnostic (IVD) next-generation sequencing test designed to detect 139 CFTR variants as defined in the CFTR2 database. Other methods test only for those variants most commonly found in Caucasians, potentially missing CF-causing variants across broader ethnic groups. The MiSeqDx Cystic Fibrosis 139-Variant Assay offers the largest CF variant panel to overcome this bias and provide comprehensive detection across diverse demographics.2
Widely adopted next-generation sequencing
The MiSeqDx Cystic Fibrosis 139-Variant Assay provides a fully integrated molecular CF testing solution on the MiSeqDx instrument. Simply prepare libraries from 250 ng gDNA, load on to the MiSeqDx for sequencing using Illumina sequencing by synthesis (SBS) chemistry, and analyze with the user-friendly software. The automated workflow is quick and easy to perform, potentially minimizing human error.
A complete kit for library preparation and sequencing
The MiSeqDx Cystic Fibrosis 139-Variant Assay includes all index primers and reagents needed for library preparation, sample multiplexing, and sequencing in a single kit. MiSeqDx sequencing reagents are packaged in a convenient ready-to-use format, minimizing hands-on time and increasing uniformity in all tests. To accommodate a broad spectrum of testing needs, from small to large volumes, the assay is available in two kit configurations (2 or 20 runs).
Specifications:
Assay Time 2.5 days
Hands-On Time 3.5 hours
Input Quantity 250 ng genomic DNA
System Compatibility MiSeqDx
Technology Sequencing"
"Illumina/MiSeqDx Universal Kit (2 runs, up to 96 samples)/DX-103-1001/1 Ea
" DX-103-1001 Illumina 產(chǎn)品編號: DX-103-1001美 元 價: $12410.00會 員 價: 待定品 牌: Illumina產(chǎn) 地: 美國公 司: Illumina, Inc.產(chǎn)品分類: 其它>其它試劑>臨床研究公司分類: In Vitro Diagnostic (IVD) Products "Product Highlights:
FlexIBLe Assay Design - Develop assays to meet the specific needs of your customers
Validated Kit – Verified performance standards for supplied library preparation and sequencing reagents
Fast Results - Go from genomic DNA to fully analyzed data in < 2 days
High Assay Reproducibility - Consistent results between multiple operators and systems
The MiSeqDx Universal Kit is a validated, FDA-cleared amplicon sequencing solution that enables clinical laboratories to develop their own next-generation sequencing (NGS) assays for use on the FDA-cleared MiSeqDx instrument. Together, the MiSeqDx Universal Kit and instrument offer molecular diagnostics labs the accuracy and reliABIlity needed to bring NGS capABIlities into their facilities.
Customized assay design
With the MiSeqDx Universal Kit, molecular diagnostics labs develop assays using oligonucleotide probes they have designed on their own. This provides users with the flexibility to target specific regions of interest and better meet the needs of their customers.
Streamlined workflow
Prepare libraries, load on to the MiSeqDx for sequencing using the Illumina sequencing by synthesis (SBS) chemistry, and analyze with the user-friendly software. The automated workflow is quick and easy to perform, potentially minimizing human error.
Specifications:
Assay Time 1 day
Hands-On Time 2.5 hours
Input Quantity 250 ng genomic DNA
System Compatibility MiSeqDx
Technology Sequencing"
"Illumina/MiSeqDx Cystic Fibrosis Clinical Sequencing Assay (6 runs, 48 samples)/DX-102-1001/1 Ea
" DX-102-1001 Illumina 產(chǎn)品編號: DX-102-1001美 元 價: $9504.00會 員 價: 待定品 牌: Illumina產(chǎn) 地: 美國公 司: Illumina, Inc.產(chǎn)品分類: 其它>其它試劑>臨床研究公司分類: In Vitro Diagnostic (IVD) Products "Product Highlights:
Complete View of the CFTR Gene
Capture all variants in the protein coding regions and intron/exon boundaries of the CFTR gene
Accurate Results
Deep coverage (> 3,000×) allows detection accuracy with a Positive Agreement (PA) of 99.66%*
No Demographic Bias
Sequencing the CFTR gene removes the bias inherent in existing genotyping panels1
* PA includes polyTG/polyT variants
The MiSeqDx Cystic Fibrosis Clinical Sequencing Assay is the first FDA-cleared in vitro diagnostic (IVD) next-generation sequencing (NGS) test designed to sequence all protein coding regions and intron/exon boundaries of the CFTR gene, including two large deletions, two deep intronic mutations, and indels in homopolymeric regions such as the 2184delA deletion. The assay also automatically detects polyTG/polyT variants. Viewing the CFTR sequence eliminates any bias inherent in existing cystic fibrosis (CF) panels. As a result, the MiSeqDx Cystic Fibrosis Clinical Sequencing Assay can uncover rare mutations not accounted for in standard tests.
Widely adopted next-generation sequencing
The MiSeqDx Cystic Fibrosis Clinical Sequencing Assay provides a fully integrated molecular CF testing solution on the MiSeqDx instrument. Amplify 27 CFTR gene target regions in a single PCR step, and multiplex samples to streamline your workflow. Simply prepare libraries from 250 ng gDNA, load on to the MiSeqDx for sequencing using the Illumina sequencing by synthesis (SBS) chemistry, and analyze with the user-friendly software.
A complete kit for library preparation and sequencing
The MiSeqDx Cystic Fibrosis Clinical Sequencing Assay includes all index primers and reagents needed for library preparation, sample multiplexing, and sequencing in a single kit. MiSeqDx sequencing reagents are packaged in a convenient ready-to-use format, minimizing hands-on time, and increasing uniformity in all tests.
Specifications:
Assay Time 2.5 days
Hands-On Time 3.5 hours
Input Quantity 250 ng genomic DNA
System Compatibility MiSeqDx
Technology Sequencing"
"Illumina/MiSeqDx Cystic Fibrosis 139-Variant Assay (2 runs, 96 samples)/DX-102-1004/1 Ea
" DX-102-1004 Illumina 產(chǎn)品編號: DX-102-1004美 元 價: $5760.00會 員 價: 待定品 牌: Illumina產(chǎn) 地: 美國公 司: Illumina, Inc.產(chǎn)品分類: 其它>其它試劑>臨床研究公司分類: In Vitro Diagnostic (IVD) Products "Product Highlights:
Compared to the current ACMG recommended cystic fibrosis variant panel, the MiSeqDx Cystic Fibrosis 139-Variant Assay offers:
Improved Detection Rates of Cystic Fibrosis-Causing Variants
Detection of couples at risk increased from 72% to ~91%1
Reduced Additional Testing
Highly accurate and reproducIBLe sequencing technology delivers dependable results
The MiSeqDx Cystic Fibrosis 139-Variant Assay is an FDA-cleared in vitro diagnostic (IVD) next-generation sequencing test designed to detect 139 CFTR variants as defined in the CFTR2 database. Other methods test only for those variants most commonly found in Caucasians, potentially missing CF-causing variants across broader ethnic groups. The MiSeqDx Cystic Fibrosis 139-Variant Assay offers the largest CF variant panel to overcome this bias and provide comprehensive detection across diverse demographics.2
Widely adopted next-generation sequencing
The MiSeqDx Cystic Fibrosis 139-Variant Assay provides a fully integrated molecular CF testing solution on the MiSeqDx instrument. Simply prepare libraries from 250 ng gDNA, load on to the MiSeqDx for sequencing using Illumina sequencing by synthesis (SBS) chemistry, and analyze with the user-friendly software. The automated workflow is quick and easy to perform, potentially minimizing human error.
A complete kit for library preparation and sequencing
The MiSeqDx Cystic Fibrosis 139-Variant Assay includes all index primers and reagents needed for library preparation, sample multiplexing, and sequencing in a single kit. MiSeqDx sequencing reagents are packaged in a convenient ready-to-use format, minimizing hands-on time and increasing uniformity in all tests. To accommodate a broad spectrum of testing needs, from small to large volumes, the assay is available in two kit configurations (2 or 20 runs).
Specifications:
Assay Time 2.5 days
Hands-On Time 3.5 hours
Input Quantity 250 ng genomic DNA
System Compatibility MiSeqDx
Technology Sequencing
"
Illumina
Illumina/TruSight RNA Fusion Panel Set A (48 samples)/RS-304-1002/1 Ea RS-304-1002 Illumina 產(chǎn)品編號: RS-304-1002美 元 價: $0.00會 員 價: 待定品 牌: Illumina產(chǎn) 地: 美國公 司: Illumina, Inc.產(chǎn)品分類: 其它>其它試劑>芯片公司分類: Clinical Research Products "Product Highlights:
This targeted RNA sequencing panel is a cost-effective solution to detect gene fusions in multiple cancer types, regardless of origin. Covering 507 fusion-associated genes, a single assay enables researchers to assess most known cancer-related fusions in blood, bone marrow, and FFPE samples, with the power to identify novel fusion gene partners.
Industry-validated content for a comprehensive view of cancer-related fusion genes, detecting common and novel fusions
From RNA to results in 4 days including on-instrument software that displays fusion calls
Compatibility with desktop sequencers to maximize lab budgets
Optimized RNA sequencing for all sample types, including FFPE tissues
Simple Fusion Report for Customers New to NGS
On-instrument fusion calling provides NGS-based fusion detection to labs without additional bioinformatics support. The analysis provides a list of detected fusions, relevant disease associations (as identified by the Mitelman database), and evidence of fusion-supporting reads.
Robust, ReproducIBLe, and Low-Input Fusion Assay
This assay accommodates as little input as 20 ng FFPE RNA or 10 ng fresh-frozen total RNA. The TruSight RNA Fusion Panel provides a sensitive, reproducIBLe, and economical solution for studies of gene fusions in cancer research.
Specifications:
Assay Time 2.5 days
Hands-On Time 11 hours
Input Quantity 10 ng total RNA, 20–100 ng FFPE RNA
System Compatibility MiSeq,NextSeq 550,MiSeqDx in Research Mode,MiniSeq,NextSeq 500
Method Targeted RNA Sequencing,Sequencing for Cytogenomics
Variant Class Gene Fusions
Specialized Sample Types FFPE,Low Input
Technology Sequencing
Species Category Human
Cancer Type Pan-Cancer"
"Illumina/TruSight Rapid Capture (4 indexes, 16 samples, 4 enrichments)/FC-140-1103/1 Ea
" FC-140-1103 Illumina 產(chǎn)品編號: FC-140-1103美 元 價: $0.00會 員 價: 待定品 牌: Illumina產(chǎn) 地: 美國公 司: Illumina, Inc.產(chǎn)品分類: 其它>其它試劑>芯片公司分類: Clinical Research Products "Product Highlights:
Targeting genes previously linked to a predisposition towards cancer.
Developed in collaboration with Professor Nazneen Rahman and team at the Institute of Cancer Research (ICR), London
Targets 94 genes and 284 SNPs associated with a predisposition towards cancer
TruSight Cancer includes genes associated with both common (e.g., breast, colorectal) and rare cancers. In addition, the set includes 284 SNPs found to correlate with cancer through genome-wide association studies (GWAS). Content selection was based on expert curation of the scientific literature and other high-quality resources.
The TruSight Cancer sequencing panel provides custom oligos targeting identified regions of interest. Sufficient product is supplied for four enrichment reactions. TruSight Cancer is compatIBLe with TruSight Rapid Capture.
TruSight Cancer Sample Datasets
6 human reference samples were prepared using the TruSight Cancer sequencing panel. These libraries were sequenced on the MiniSeq System using a high output kit at a 2 x 100 bp read length configuration with dual indexing. The total yield was 5.2 Gb with 95.8% of bases at or above Q30.
Browse the data in BaseSpace Sequence Hub:
View Run
View Project
* Note that access to this data requires a BaseSpace Sequence Hub login.
Register for BaseSpace Sequence Hub
Specifications:
Assay Time 1.5 days
Input Quantity 50 ng
System Compatibility MiSeq,NextSeq 550,MiSeqDx in Research Mode,MiniSeq,NextSeq 500
Specialized Sample Types Low Input
Technology Sequencing
Species Category Human
Variant Class Germline Variants
Cancer Type Pan-Cancer
Method Targeted DNA Sequencing"
"Illumina/TruSight HLA v2 Sequencing Panel (24 samples, automated)/20005170/1 Ea
" 20005170 Illumina 產(chǎn)品編號: 20005170美 元 價: $0.00會 員 價: 待定品 牌: Illumina產(chǎn) 地: 美國公 司: Illumina, Inc.產(chǎn)品分類: 其它>其它試劑>芯片公司分類: Clinical Research Products "Product Highlights:
The TruSight HLA v2 Sequencing Panel provides clinical researchers with a broad-coverage, ultra-high–resolution human leukocyte antigen (HLA) typing solution for simple, rapid assessment of the HLA region in a single assay. It features:
High-resolution sequencing of 11 HLA loci
Workflow with library preparation, sequencing and data analysis/reporting
Accurate and high-resolution HLA typing for unambiguous results
Capture Full HLA Gene Sequences
TruSight HLA v2 covers all commonly typed HLA loci, plus those with emerging relevance. This panel enables sequencing of Class I HLA-A, B, and C; Class II HLA-DRB1/3/4/5, HLA-DQA1, HLA-DQB1, HLA-DPA1, and HLA-DPB1. This expands coverage beyond the classic loci, with full gene coverage, enabling discovery of new alleles without the need to design new primers.
Sample-to-Report Workflow with Optimized Data Analysis
The comprehensive solution includes reagents and software optimized for HLA analysis. A simplified workflow enables turnaround time of less than 48 hours and increased efficiency with less than 4.5 hours of hands-on time. On-instrument software analyzes sequence data; TruSight HLA Assign Software provides flexIBLe options for post-analysis reporting of results.
High-Accuracy HLA Typing
The expanded coverage of TruSight HLA v2 provides high resolution, eliminating the need for follow-up testing to obtain a confident typing result. View HLA Loci.
How TruSight HLA v2 Works
TruSight HLA v2 amplifies HLA loci with long-range PCR. After amplification, Nextera tagmentation fragments the DNA and leaves behind a sequence tag. An additional PCR then adds sequence adapters and indexing primers to generate sequencing-ready DNA libraries. Prepared libraries are then loaded directly onto a MiniSeq, MiSeq or NextSeq System for sequencing.
Analysis Software Highlights
The Assign 2.0 TruSight HLA analysis software assists with the assignment of a human leukocyte antigen (HLA) type. The software is designed to analyze data from libraries prepared with Illumina TruSight HLA Sequencing Panels and then sequenced on an Illumina sequencer. Use Assign 2.0 to import sequence data, perform base calling, edit sequences, and compare a sample consensus sequence with the IMGT/HLA database of alleles.
Specifications:
Assay Time 48 hours
Hands-On Time 4.5 hours
Input Quantity 400 ng DNA
System Compatibility MiSeq,NextSeq 550,MiSeqDx in Research Mode,MiniSeq,NextSeq 500
Variant Class Single Nucleotide Polymorphisms (SNPs)
Technology Sequencing
Species Category Human
Method HLA Sequencing"
Illumina/TruSight Tumor 170 Kit plus Watson for Genomics/20018622/1 Ea 20018622 Illumina 產(chǎn)品編號: 20018622美 元 價: $0.00會 員 價: 待定品 牌: Illumina產(chǎn) 地: 美國公 司: Illumina, Inc.產(chǎn)品分類: 其它>其它試劑>芯片公司分類: Clinical Research Products "Product Highlights:
TruSight Tumor 170, a next-generation sequencing assay designed to cover 170 genes associated with common solid tumors, is an enrichment-based targeted panel that simultaneously analyzes DNA and RNA, covering a wide range of genes and variant types. The comprehensive nature provides laboratories with a deep view into the genetics of cancer.
Comprehensive Coverage of Cancer-Related Variants
Assessment of fusions, splice variants, insertions/deletions and single-nucleotide variants (SNVs), and amplifications in one assay using DNA and RNA creates efficiencies in sample usage, time, and cost.
Accurate Results from Low-Quality Samples1
Variant detection with as little as 40 ng DNA and RNA input, and as low as 5% mutant allele frequency, maximizes the results from precious formalin-fixed paraffin-embedded (FFPE) samples.
Integrated, Streamlined Workflow
DNA and RNA are prepared in parallel with an integrated workflow following DNA shearing/CDNA synthesis.
Specifications:
Assay Time ~2 days (Library Prep)
Hands-On Time ~10.5 hours
Input Quantity 40 ng DNA and/or RNA
Method Targeted RNA Sequencing,Targeted DNA Sequencing
Variant Class Single Nucleotide Polymorphisms (SNPs),Gene Fusions,Somatic Variants,Structural Variants,Insertions-Deletions (indels),Copy Number Variants (CNVs)
Specialized Sample Types FFPE,Low Input
System Compatibility NextSeq 550,NextSeq 500,HiSeq 2500
Technology Sequencing
Species Category Human
Cancer Type Solid Tumor
Scientific Posters:
AACR 2017: TruSight Tumor 170 and Tumor Mutational Burden
Results of analysis indicate that TruSight Tumor 170, with comprehensive coverage of cancer-related genes, shows high concordance with whole exome sequencing for accurate assessment of tumor mutational burden.
Learn More
AACR 2017: TruSight Tumor 170 and Solid Tumor Profiling Analytical Performance with FFPE Samples
Standard extractions from FFPE embedded samples provide sufficient material (40ng) in >95% of samples that were extracted by Illumina. This data shows that the TruSight Tumor 170 panel is a robust assay that generates passing sample QC data in >85% of samples with varying quality, and in >95% of samples that have quality metrics that fall within the recommendations for the kit.
Learn More
AACR 2017: TruSight Tumor 170 for Small Nucleotide Variations and Gene Amplifications in FFPE DNA Samples
TruSight Tumor 170 can achieve high sensitivity and specificity for the detection of somatic variants (small variants and CNVs) from DNA extracted from FFPE tissues.
Learn More
AACR 2017: TruSight Tumor 170 for Fusions and Splice Variants in FFPE RNA Tumor Samples
Through examining limit of detection in the context of RNA expression, this study shows that TruSight Tumor 170 provides high sensitivity and specificity in RNA variant calling down to 5 copies of transcript per ng of input.
Learn More"
"Illumina/TruSight Rapid Capture (24 indexes, 48 samples, 4 enrichments)/FC-140-1104/1 Ea
" FC-140-1104 Illumina 產(chǎn)品編號: FC-140-1104美 元 價: $0.00會 員 價: 待定品 牌: Illumina產(chǎn) 地: 美國公 司: Illumina, Inc.產(chǎn)品分類: 其它>其它試劑>芯片公司分類: Clinical Research Products "Product Highlights:
Targeting genes previously linked to a predisposition towards cancer.
Developed in collaboration with Professor Nazneen Rahman and team at the Institute of Cancer Research (ICR), London
Targets 94 genes and 284 SNPs associated with a predisposition towards cancer
TruSight Cancer includes genes associated with both common (e.g., breast, colorectal) and rare cancers. In addition, the set includes 284 SNPs found to correlate with cancer through genome-wide association studies (GWAS). Content selection was based on expert curation of the scientific literature and other high-quality resources.
The TruSight Cancer sequencing panel provides custom oligos targeting identified regions of interest. Sufficient product is supplied for four enrichment reactions. TruSight Cancer is compatIBLe with TruSight Rapid Capture.
TruSight Cancer Sample Datasets
6 human reference samples were prepared using the TruSight Cancer sequencing panel. These libraries were sequenced on the MiniSeq System using a high output kit at a 2 x 100 bp read length configuration with dual indexing. The total yield was 5.2 Gb with 95.8% of bases at or above Q30.
Browse the data in BaseSpace Sequence Hub:
View Run
View Project
* Note that access to this data requires a BaseSpace Sequence Hub login.
Register for BaseSpace Sequence Hub
Specifications:
Assay Time 1.5 days
Input Quantity 50 ng
System Compatibility MiSeq,NextSeq 550,MiSeqDx in Research Mode,MiniSeq,NextSeq 500
Specialized Sample Types Low Input
Technology Sequencing
Species Category Human
Variant Class Germline Variants
Cancer Type Pan-Cancer
Method Targeted DNA Sequencing"
"Illumina/TruSight One Expanded Sequencing Panel (36 samples)/FC-141-2007/1 Ea
" FC-141-2007 Illumina 產(chǎn)品編號: FC-141-2007美 元 價: $0.00會 員 價: 待定品 牌: Illumina產(chǎn) 地: 美國公 司: Illumina, Inc.產(chǎn)品分類: 其它>其它試劑>芯片公司分類: Clinical Research Products "Product Highlights:
TruSight One Sequencing Panels enable labs to expand and streamline their sequencing portfolio, while managing costs.
Two panels offer options to target up to 6700 genes associated with human disease, with high coverage
Single assay includes multiple genes of interest, replacing iterative testing
Easy, flexIBLe gene filtering and annotation options simplify BIOLOGical interpretation and reporting
These panels provide clinical research labs with an affordable solution for managing a diverse assay portfolio. The TruSight One Sequencing Panel provides comprehensive coverage of > 4800 disease-associated genes, while the TruSight One Expanded Sequencing Panel targets ~1900 additional genes with recent disease associations in the scientific literature. Investigators can choose to analyze all of the genes on the panel or focus on a specific subset. With a single assay, labs can expand existing menus, streamline workflows, or create an entire portfolio of sequencing options.
Specifications:
Input Quantity 50 ng
Content Specifications ~12 Mb genomic content for TruSight One; ~16.5 Mb genomic content for TruSight One Expanded
Multiplexing Up to 96-plex
System Compatibility MiSeq,NextSeq 550,HiSeq 3000,MiSeqDx in Research Mode,MiniSeq,NextSeq 500,HiSeq 2500,NovaSeq 6000,HiSeq 4000
Variant Class Single Nucleotide Polymorphisms (SNPs),Germline Variants
Specialized Sample Types Low Input
Technology Sequencing
Species Category Human
Method Targeted DNA Sequencing"
"Illumina/TruSight Rapid Capture (24 indexes, 96 samples, 8 enrichments)/FC-140-1105/1 Ea
" FC-140-1105 Illumina 產(chǎn)品編號: FC-140-1105美 元 價: $0.00會 員 價: 待定品 牌: Illumina產(chǎn) 地: 美國公 司: Illumina, Inc.產(chǎn)品分類: 其它>其它試劑>芯片公司分類: Clinical Research Products "Product Highlights:
Targeting genes previously linked to a predisposition towards cancer.
Developed in collaboration with Professor Nazneen Rahman and team at the Institute of Cancer Research (ICR), London
Targets 94 genes and 284 SNPs associated with a predisposition towards cancer
TruSight Cancer includes genes associated with both common (e.g., breast, colorectal) and rare cancers. In addition, the set includes 284 SNPs found to correlate with cancer through genome-wide association studies (GWAS). Content selection was based on expert curation of the scientific literature and other high-quality resources.
The TruSight Cancer sequencing panel provides custom oligos targeting identified regions of interest. Sufficient product is supplied for four enrichment reactions. TruSight Cancer is compatIBLe with TruSight Rapid Capture.
TruSight Cancer Sample Datasets
6 human reference samples were prepared using the TruSight Cancer sequencing panel. These libraries were sequenced on the MiniSeq System using a high output kit at a 2 x 100 bp read length configuration with dual indexing. The total yield was 5.2 Gb with 95.8% of bases at or above Q30.
Browse the data in BaseSpace Sequence Hub:
View Run
View Project
* Note that access to this data requires a BaseSpace Sequence Hub login.
Register for BaseSpace Sequence Hub
Specifications:
Assay Time 1.5 days
Input Quantity 50 ng
System Compatibility MiSeq,NextSeq 550,MiSeqDx in Research Mode,MiniSeq,NextSeq 500
Specialized Sample Types Low Input
Technology Sequencing
Species Category Human
Variant Class Germline Variants
Cancer Type Pan-Cancer
Method Targeted DNA Sequencing"
"Illumina/TruSight RNA Pan-Cancer Panel Set B/RS-303-1003/1 Ea
" RS-303-1003 Illumina 產(chǎn)品編號: RS-303-1003美 元 價: $0.00會 員 價: 待定品 牌: Illumina產(chǎn) 地: 美國公 司: Illumina, Inc.產(chǎn)品分類: 其它>其它試劑>芯片公司分類: Clinical Research Products "Product Highlights:
The TruSight RNA Pan-Cancer panel provides a comprehensive analysis of the cancer transcriptome. It offers:
Gene expression information, variant calling, and fusion detection with known and novel gene fusion partners
Optimized, low-input protocol for a wide range of sample types including FFPE
A comprehensive view of cancer pathways
Economical RNA sequencing (RNA-Seq) on a desktop sequencer
Highly Sensitive and Economical Targeted Sequencing
The TruSight RNA Pan-Cancer panel enables the quantitative measurement of gene expression as well as the detection of gene fusions with both known and novel gene fusion partners. The panel accommodates as little as 10 ng of total RNA input (or 20 ng from FFPE samples). The focus on a subset of relevant genes enables RNA-Seq with high sensitivity at 8 samples per run on a desktop sequencer, allowing cost-effective access to NGS for any lab.
Intuitive Cloud-based Data Analysis
Analysis can be performed using the RNA-Seq Alignment BaseSpace App. This intuitive tool performs fusion calling andvariant detection, and provides gene expression profiles, offering a comprehensive solution to all cancer researchers.
TruSight RNA Pan-Cancer Sample Datasets
MiSeq Data
10 ng of human reference RNA (UHR), human reference brain RNA (Brain), cell line RNA (MCF7), and 20 ng of breast tumor FFPE RNA (BT) were prepared using the TruSight RNA Pan-Cancer Panel and sequenced on the MiSeq System. Read mapping and fusion calling were performed using the RNA-Seq Alignment App with STAR aligner on BaseSpace Sequence Hub.
View Project
MiniSeq Data
Human reference RNA (HBRR and UHRR), cell line RNA (MCF7), and breast tumor RNA samples were prepared using the TruSight RNA Pan-Cancer panel, and 8 samples were sequenced on the MiniSeq System at a 2x76bp read length with single indexing. The total yield was 4.2 Gb with 96.8% of bases at or above Q30.
Browse the data in BaseSpace Sequence Hub:
View Run
View Project
Access to this data requires a BaseSpace Sequence Hub login.
Register for BaseSpace Sequence Hub
Specifications:
Assay Time 2.5 days
Hands-On Time 11 hours
Input Quantity 10 ng total RNA,20 - 100 ng FFPE RNA
System Compatibility MiSeq,NextSeq 550,MiSeqDx in Research Mode,MiniSeq,NextSeq 500
Method Targeted RNA Sequencing,Sequencing for Cytogenomics
Variant Class Gene Fusions,Somatic Variants,Novel Transcripts,Transcript Variants
Specialized Sample Types FFPE,Low Input
Technology Sequencing
Species Category Human
Cancer Type Pan-Cancer
"
"Illumina/TruSight HLA v2 Sequencing Panel (24 samples)/20000215/1 Ea
" 20000215 Illumina 產(chǎn)品編號: 20000215美 元 價: $0.00會 員 價: 待定品 牌: Illumina產(chǎn) 地: 美國公 司: Illumina, Inc.產(chǎn)品分類: 其它>其它試劑>芯片公司分類: Clinical Research Products "Product Highlights:
The TruSight HLA v2 Sequencing Panel provides clinical researchers with a broad-coverage, ultra-high–resolution human leukocyte antigen (HLA) typing solution for simple, rapid assessment of the HLA region in a single assay. It features:
High-resolution sequencing of 11 HLA loci
Workflow with library preparation, sequencing and data analysis/reporting
Accurate and high-resolution HLA typing for unambiguous results
Capture Full HLA Gene Sequences
TruSight HLA v2 covers all commonly typed HLA loci, plus those with emerging relevance. This panel enables sequencing of Class I HLA-A, B, and C; Class II HLA-DRB1/3/4/5, HLA-DQA1, HLA-DQB1, HLA-DPA1, and HLA-DPB1. This expands coverage beyond the classic loci, with full gene coverage, enabling discovery of new alleles without the need to design new primers.
Sample-to-Report Workflow with Optimized Data Analysis
The comprehensive solution includes reagents and software optimized for HLA analysis. A simplified workflow enables turnaround time of less than 48 hours and increased efficiency with less than 4.5 hours of hands-on time. On-instrument software analyzes sequence data; TruSight HLA Assign Software provides flexIBLe options for post-analysis reporting of results.
High-Accuracy HLA Typing
The expanded coverage of TruSight HLA v2 provides high resolution, eliminating the need for follow-up testing to obtain a confident typing result. View HLA Loci.
How TruSight HLA v2 Works
TruSight HLA v2 amplifies HLA loci with long-range PCR. After amplification, Nextera tagmentation fragments the DNA and leaves behind a sequence tag. An additional PCR then adds sequence adapters and indexing primers to generate sequencing-ready DNA libraries. Prepared libraries are then loaded directly onto a MiniSeq, MiSeq or NextSeq System for sequencing.
Analysis Software Highlights
The Assign 2.0 TruSight HLA analysis software assists with the assignment of a human leukocyte antigen (HLA) type. The software is designed to analyze data from libraries prepared with Illumina TruSight HLA Sequencing Panels and then sequenced on an Illumina sequencer. Use Assign 2.0 to import sequence data, perform base calling, edit sequences, and compare a sample consensus sequence with the IMGT/HLA database of alleles.
Specifications:
Assay Time 48 hours
Hands-On Time 4.5 hours
Input Quantity 400 ng DNA
System Compatibility MiSeq,NextSeq 550,MiSeqDx in Research Mode,MiniSeq,NextSeq 500
Variant Class Single Nucleotide Polymorphisms (SNPs)
Technology Sequencing
Species Category Human
Method HLA Sequencing"
"Illumina/TruSight Tumor 15 MiniSeq Kit/20005610/1 Ea
" 20005610 Illumina 產(chǎn)品編號: 20005610美 元 價: $0.00會 員 價: 待定品 牌: Illumina產(chǎn) 地: 美國公 司: Illumina, Inc.產(chǎn)品分類: 其它>其它試劑>芯片公司分類: Clinical Research Products "Product Highlights:
TruSight Tumor 15 uses next-generation sequencing (NGS) technology to provide a comprehensive assessment of 15 genes that are commonly mutated in solid tumors. It accurately detects low-frequency variants from 20 ng of starting DNA and is optimized for formalin-fixed, paraffin-embedded (FFPE) tumor tissue.
View the Gene List
Featuring a rapid workflow that can be easily integrated into lab procedures, this panel offers a single assay for accurate, economical, and rapid analysis of solid tumors.
This TruSight Tumor panel offers:
Comprehensive workflow: Assess 15 genes with one simple workflow instead of single, iterative gene testing with polymerase chain reaction (PCR)
Efficient: Rapid turnaround with only 3.5 hours of hands-on time, going from DNA to data in approximately 36 hours
Relevant gene content for solid tumors: Somatic variants selected from relevant industry guidelines1,2, key opinion leaders3,4, and pharmaceutical research
Sensitive variant detection from low DNA input: Accurate somatic variant detection of 5% allele frequency using 20 ng DNA from FFPE tissue samples
TruSight Tumor 15 Sample Datasets
3 human reference samples and 5 FFPE-exacted DNA samples from lung, colon, melanoma, and breast tumors were prepared using TruSight Tumor 15. These libraries were sequenced on the MiniSeq System using a high output kit at a 2 x 150 bp read length configuration with dual indexing. The total yield was 7.6 Gb with 94.9% of bases at or above Q30.
Browse the data in BaseSpace Sequence Hub:
View Run
View Project
Access to this data requires a BaseSpace Sequence Hub login.
Register for BaseSpace Sequence Hub
Specifications:
Assay Time 7 hours
Hands-On Time 3.5 hours
Input Quantity 20 ng
System Compatibility MiSeq,MiSeqDx in Research Mode,MiniSeq
Specialized Sample Types FFPE,Low Input
Technology Sequencing
Variant Class Somatic Variants,Insertions-Deletions (indels)
Species Category Human
Cancer Type Solid Tumor
Method Amplicon Sequencing,Targeted DNA Sequencing"
"Illumina/TruSight RNA Pan-Cancer Set A MiniSeq Kit/20005611/1 Ea
" 20005611 Illumina 產(chǎn)品編號: 20005611美 元 價: $0.00會 員 價: 待定品 牌: Illumina產(chǎn) 地: 美國公 司: Illumina, Inc.產(chǎn)品分類: 其它>其它試劑>芯片公司分類: Clinical Research Products "Product Highlights:
The TruSight RNA Pan-Cancer panel provides a comprehensive analysis of the cancer transcriptome. It offers:
Gene expression information, variant calling, and fusion detection with known and novel gene fusion partners
Optimized, low-input protocol for a wide range of sample types including FFPE
A comprehensive view of cancer pathways
Economical RNA sequencing (RNA-Seq) on a desktop sequencer
Highly Sensitive and Economical Targeted Sequencing
The TruSight RNA Pan-Cancer panel enables the quantitative measurement of gene expression as well as the detection of gene fusions with both known and novel gene fusion partners. The panel accommodates as little as 10 ng of total RNA input (or 20 ng from FFPE samples). The focus on a subset of relevant genes enables RNA-Seq with high sensitivity at 8 samples per run on a desktop sequencer, allowing cost-effective access to NGS for any lab.
Intuitive Cloud-based Data Analysis
Analysis can be performed using the RNA-Seq Alignment BaseSpace App. This intuitive tool performs fusion calling andvariant detection, and provides gene expression profiles, offering a comprehensive solution to all cancer researchers.
TruSight RNA Pan-Cancer Sample Datasets
MiSeq Data
10 ng of human reference RNA (UHR), human reference brain RNA (Brain), cell line RNA (MCF7), and 20 ng of breast tumor FFPE RNA (BT) were prepared using the TruSight RNA Pan-Cancer Panel and sequenced on the MiSeq System. Read mapping and fusion calling were performed using the RNA-Seq Alignment App with STAR aligner on BaseSpace Sequence Hub.
View Project
MiniSeq Data
Human reference RNA (HBRR and UHRR), cell line RNA (MCF7), and breast tumor RNA samples were prepared using the TruSight RNA Pan-Cancer panel, and 8 samples were sequenced on the MiniSeq System at a 2x76bp read length with single indexing. The total yield was 4.2 Gb with 96.8% of bases at or above Q30.
Browse the data in BaseSpace Sequence Hub:
View Run
View Project
Access to this data requires a BaseSpace Sequence Hub login.
Register for BaseSpace Sequence Hub
Specifications:
Assay Time 2.5 days
Hands-On Time 11 hours
Input Quantity 10 ng total RNA,20 - 100 ng FFPE RNA
System Compatibility MiSeq,NextSeq 550,MiSeqDx in Research Mode,MiniSeq,NextSeq 500
Method Targeted RNA Sequencing,Sequencing for Cytogenomics
Variant Class Gene Fusions,Somatic Variants,Novel Transcripts,Transcript Variants
Specialized Sample Types FFPE,Low Input
Technology Sequencing
Species Category Human
Cancer Type Pan-Cancer
"
"Illumina/TG TruSight Inherited Disease Sequencing Panel (48 Samples)/TG-141-1005/1 Ea
" TG-141-1005 Illumina 產(chǎn)品編號: TG-141-1005美 元 價: $0.00會 員 價: 待定品 牌: Illumina產(chǎn) 地: 美國公 司: Illumina, Inc.產(chǎn)品分類: 其它>其它試劑>芯片公司分類: Clinical Research Products "Product Highlights:
Developed in collaboration with Dr. Stephen Kingsmore and team during his tenure at Children's Mercy Hospital (CMH) for Pediatric Genomic Medicine, Dr. Carol Saunders at CMH, and Dr. Hilger Ropers at the Max Planck Institute
Targets 552 genes, including coding exons, intron-exon boundaries, and regions known to harbor pathogenic mutations
TruSight Inherited Disease was initially based on a 448 disease panel designed for preconception carrier testing for severe, recessive childhood diseases published by Dr. Kingsmore and team in Science Translational Medicine1.
The original content was revised by Dr. Saunders, FACMG, at CMH (following ACMG guidelines for testing ultra-rare genetic diseases) to reflect the needs of medical geneticists with a primary focus on severe recessive diseases with childhood onset. Intellectual disABIlity genes were added by Dr. Ropers.
The TruSight Inherited Disease sequencing panel set includes custom oligos targeting identified regions of interest. Sufficient product is supplied for four enrichment reactions.
Specifications:
Input Quantity 50 ng DNA
System Compatibility MiSeq,NextSeq 550,MiSeqDx in Research Mode,MiniSeq,NextSeq 500,HiSeq 2500
Variant Class Single Nucleotide Polymorphisms (SNPs),Germline Variants
Specialized Sample Types Low Input
Technology Sequencing
Species Category Human
Method Targeted DNA Sequencing"
"Illumina/TruSeq Index Plate Fixture Kit (2 fixtures)/FC-130-1005/1 Ea
" FC-130-1005 Illumina 產(chǎn)品編號: FC-130-1005美 元 價: $0.00會 員 價: 待定品 牌: Illumina產(chǎn) 地: 美國公 司: Illumina, Inc.產(chǎn)品分類: 其它>其它試劑>芯片公司分類: Clinical Research Products "Product Highlights:
The TruSight HLA v2 Sequencing Panel provides clinical researchers with a broad-coverage, ultra-high–resolution human leukocyte antigen (HLA) typing solution for simple, rapid assessment of the HLA region in a single assay. It features:
High-resolution sequencing of 11 HLA loci
Workflow with library preparation, sequencing and data analysis/reporting
Accurate and high-resolution HLA typing for unambiguous results
Capture Full HLA Gene Sequences
TruSight HLA v2 covers all commonly typed HLA loci, plus those with emerging relevance. This panel enables sequencing of Class I HLA-A, B, and C; Class II HLA-DRB1/3/4/5, HLA-DQA1, HLA-DQB1, HLA-DPA1, and HLA-DPB1. This expands coverage beyond the classic loci, with full gene coverage, enabling discovery of new alleles without the need to design new primers.
Sample-to-Report Workflow with Optimized Data Analysis
The comprehensive solution includes reagents and software optimized for HLA analysis. A simplified workflow enables turnaround time of less than 48 hours and increased efficiency with less than 4.5 hours of hands-on time. On-instrument software analyzes sequence data; TruSight HLA Assign Software provides flexIBLe options for post-analysis reporting of results.
High-Accuracy HLA Typing
The expanded coverage of TruSight HLA v2 provides high resolution, eliminating the need for follow-up testing to obtain a confident typing result. View HLA Loci.
How TruSight HLA v2 Works
TruSight HLA v2 amplifies HLA loci with long-range PCR. After amplification, Nextera tagmentation fragments the DNA and leaves behind a sequence tag. An additional PCR then adds sequence adapters and indexing primers to generate sequencing-ready DNA libraries. Prepared libraries are then loaded directly onto a MiniSeq, MiSeq or NextSeq System for sequencing.
Analysis Software Highlights
The Assign 2.0 TruSight HLA analysis software assists with the assignment of a human leukocyte antigen (HLA) type. The software is designed to analyze data from libraries prepared with Illumina TruSight HLA Sequencing Panels and then sequenced on an Illumina sequencer. Use Assign 2.0 to import sequence data, perform base calling, edit sequences, and compare a sample consensus sequence with the IMGT/HLA database of alleles.
Specifications:
Assay Time 48 hours
Hands-On Time 4.5 hours
Input Quantity 400 ng DNA
System Compatibility MiSeq,NextSeq 550,MiSeqDx in Research Mode,MiniSeq,NextSeq 500
Variant Class Single Nucleotide Polymorphisms (SNPs)
Technology Sequencing
Species Category Human
Method HLA Sequencing"
"Illumina/TruSight Tumor 170 Kit (24 Samples)/OP-101-1004/1 Ea
" OP-101-100 Illumina 產(chǎn)品編號: OP-101-1004美 元 價: $0.00會 員 價: 待定品 牌: Illumina產(chǎn) 地: 美國公 司: Illumina, Inc.產(chǎn)品分類: 其它>其它試劑>芯片公司分類: Clinical Research Products "Product Highlights:
TruSight Tumor 170, a next-generation sequencing assay designed to cover 170 genes associated with common solid tumors, is an enrichment-based targeted panel that simultaneously analyzes DNA and RNA, covering a wide range of genes and variant types. The comprehensive nature provides laboratories with a deep view into the genetics of cancer.
Comprehensive Coverage of Cancer-Related Variants
Assessment of fusions, splice variants, insertions/deletions and single-nucleotide variants (SNVs), and amplifications in one assay using DNA and RNA creates efficiencies in sample usage, time, and cost.
Accurate Results from Low-Quality Samples1
Variant detection with as little as 40 ng DNA and RNA input, and as low as 5% mutant allele frequency, maximizes the results from precious formalin-fixed paraffin-embedded (FFPE) samples.
Integrated, Streamlined Workflow
DNA and RNA are prepared in parallel with an integrated workflow following DNA shearing/CDNA synthesis.
Specifications:
Assay Time ~2 days (Library Prep)
Hands-On Time ~10.5 hours
Input Quantity 40 ng DNA and/or RNA
Method Targeted RNA Sequencing,Targeted DNA Sequencing
Variant Class Single Nucleotide Polymorphisms (SNPs),Gene Fusions,Somatic Variants,Structural Variants,Insertions-Deletions (indels),Copy Number Variants (CNVs)
Specialized Sample Types FFPE,Low Input
System Compatibility NextSeq 550,NextSeq 500,HiSeq 2500
Technology Sequencing
Species Category Human
Cancer Type Solid Tumor
Scientific Posters:
AACR 2017: TruSight Tumor 170 and Tumor Mutational Burden
Results of analysis indicate that TruSight Tumor 170, with comprehensive coverage of cancer-related genes, shows high concordance with whole exome sequencing for accurate assessment of tumor mutational burden.
Learn More
AACR 2017: TruSight Tumor 170 and Solid Tumor Profiling Analytical Performance with FFPE Samples
Standard extractions from FFPE embedded samples provide sufficient material (40ng) in >95% of samples that were extracted by Illumina. This data shows that the TruSight Tumor 170 panel is a robust assay that generates passing sample QC data in >85% of samples with varying quality, and in >95% of samples that have quality metrics that fall within the recommendations for the kit.
Learn More
AACR 2017: TruSight Tumor 170 for Small Nucleotide Variations and Gene Amplifications in FFPE DNA Samples
TruSight Tumor 170 can achieve high sensitivity and specificity for the detection of somatic variants (small variants and CNVs) from DNA extracted from FFPE tissues.
Learn More
AACR 2017: TruSight Tumor 170 for Fusions and Splice Variants in FFPE RNA Tumor Samples
Through examining limit of detection in the context of RNA expression, this study shows that TruSight Tumor 170 provides high sensitivity and specificity in RNA variant calling down to 5 copies of transcript per ng of input.
Learn More"
"Illumina/TruSight Rapid Capture (1 index, 8 samples, 8 enrichments)/FC-140-1101/1 Ea
" FC-140-1101 Illumina 產(chǎn)品編號: FC-140-1101美 元 價: $0.00會 員 價: 待定品 牌: Illumina產(chǎn) 地: 美國公 司: Illumina, Inc.產(chǎn)品分類: 其它>其它試劑>芯片公司分類: Clinical Research Products "Product Highlights:
Targeting genes previously linked to a predisposition towards cancer.
Developed in collaboration with Professor Nazneen Rahman and team at the Institute of Cancer Research (ICR), London
Targets 94 genes and 284 SNPs associated with a predisposition towards cancer
TruSight Cancer includes genes associated with both common (e.g., breast, colorectal) and rare cancers. In addition, the set includes 284 SNPs found to correlate with cancer through genome-wide association studies (GWAS). Content selection was based on expert curation of the scientific literature and other high-quality resources.
The TruSight Cancer sequencing panel provides custom oligos targeting identified regions of interest. Sufficient product is supplied for four enrichment reactions. TruSight Cancer is compatIBLe with TruSight Rapid Capture.
TruSight Cancer Sample Datasets
6 human reference samples were prepared using the TruSight Cancer sequencing panel. These libraries were sequenced on the MiniSeq System using a high output kit at a 2 x 100 bp read length configuration with dual indexing. The total yield was 5.2 Gb with 95.8% of bases at or above Q30.
Browse the data in BaseSpace Sequence Hub:
View Run
View Project
* Note that access to this data requires a BaseSpace Sequence Hub login.
Register for BaseSpace Sequence Hub
Specifications:
Assay Time 1.5 days
Input Quantity 50 ng
System Compatibility MiSeq,NextSeq 550,MiSeqDx in Research Mode,MiniSeq,NextSeq 500
Specialized Sample Types Low Input
Technology Sequencing
Species Category Human
Variant Class Germline Variants
Cancer Type Pan-Cancer
Method Targeted DNA Sequencing"
"Illumina/TruSight Tumor 26/FC-130-2001/1 Ea
" FC-130-2001 Illumina 產(chǎn)品編號: FC-130-2001美 元 價: $0.00會 員 價: 待定品 牌: Illumina產(chǎn) 地: 美國公 司: Illumina, Inc.產(chǎn)品分類: 其它>其它試劑>芯片公司分類: Clinical Research Products "Product Highlights:
TruSight Tumor 26 takes a deeper view of variation in solid tumors including lung, colon, melanoma, gastric and ovarian. This enables clinical researchers to identify low-frequency variation across 26 genes for a more comprehensive view of somatic variation.
Highly accurate variant analysis at limit of detection below 5% variant allele frequency across 174 amplicons, with 1000x minimum coverage of each region
Exceptional sample success rates with minimal DNA input for accurate base calling, even in degraded FFPE samples
Coverage of complete exons for analysis of molecular heterogeneity in highly relevant content selected from CAP1 and NCCN2 guidelines, and late stage clinical trials3
This panel provides amplicon-based library preparation reagents, DNA QC, sample indexes, and oligos targeting identified regions of interest.
Genes in TruSight Tumor 26
See which solid tumor-related genes are represented in TruSight Tumor 26. View Gene List
Specifications:
Assay Time 11 hours
Hands-On Time 4 hours
Input Quantity 30 to 300 ng depending on QC results
System Compatibility MiSeq,NextSeq 550,MiSeqDx in Research Mode,MiniSeq,NextSeq 500
Specialized Sample Types FFPE
Technology Sequencing
Variant Class Somatic Variants,Insertions-Deletions (indels)
Species Category Human
Cancer Type Solid Tumor
Method Amplicon Sequencing,Targeted DNA Sequencing"
"Illumina/TruSight Tumor 170 Kit, For Use with NextSeq (24 Samples)/OP-101-1003/1 Ea
" OP-101-1003 Illumina 產(chǎn)品編號: OP-101-1003美 元 價: $0.00會 員 價: 待定品 牌: Illumina產(chǎn) 地: 美國公 司: Illumina, Inc.產(chǎn)品分類: 其它>其它試劑>芯片公司分類: Clinical Research Products "Product Highlights:
TruSight Tumor 170, a next-generation sequencing assay designed to cover 170 genes associated with common solid tumors, is an enrichment-based targeted panel that simultaneously analyzes DNA and RNA, covering a wide range of genes and variant types. The comprehensive nature provides laboratories with a deep view into the genetics of cancer.
Comprehensive Coverage of Cancer-Related Variants
Assessment of fusions, splice variants, insertions/deletions and single-nucleotide variants (SNVs), and amplifications in one assay using DNA and RNA creates efficiencies in sample usage, time, and cost.
Accurate Results from Low-Quality Samples1
Variant detection with as little as 40 ng DNA and RNA input, and as low as 5% mutant allele frequency, maximizes the results from precious formalin-fixed paraffin-embedded (FFPE) samples.
Integrated, Streamlined Workflow
DNA and RNA are prepared in parallel with an integrated workflow following DNA shearing/CDNA synthesis.
Specifications:
Assay Time ~2 days (Library Prep)
Hands-On Time ~10.5 hours
Input Quantity 40 ng DNA and/or RNA
Method Targeted RNA Sequencing,Targeted DNA Sequencing
Variant Class Single Nucleotide Polymorphisms (SNPs),Gene Fusions,Somatic Variants,Structural Variants,Insertions-Deletions (indels),Copy Number Variants (CNVs)
Specialized Sample Types FFPE,Low Input
System Compatibility NextSeq 550,NextSeq 500,HiSeq 2500
Technology Sequencing
Species Category Human
Cancer Type Solid Tumor
Scientific Posters:
AACR 2017: TruSight Tumor 170 and Tumor Mutational Burden
Results of analysis indicate that TruSight Tumor 170, with comprehensive coverage of cancer-related genes, shows high concordance with whole exome sequencing for accurate assessment of tumor mutational burden.
Learn More
AACR 2017: TruSight Tumor 170 and Solid Tumor Profiling Analytical Performance with FFPE Samples
Standard extractions from FFPE embedded samples provide sufficient material (40ng) in >95% of samples that were extracted by Illumina. This data shows that the TruSight Tumor 170 panel is a robust assay that generates passing sample QC data in >85% of samples with varying quality, and in >95% of samples that have quality metrics that fall within the recommendations for the kit.
Learn More
AACR 2017: TruSight Tumor 170 for Small Nucleotide Variations and Gene Amplifications in FFPE DNA Samples
TruSight Tumor 170 can achieve high sensitivity and specificity for the detection of somatic variants (small variants and CNVs) from DNA extracted from FFPE tissues.
Learn More
AACR 2017: TruSight Tumor 170 for Fusions and Splice Variants in FFPE RNA Tumor Samples
Through examining limit of detection in the context of RNA expression, this study shows that TruSight Tumor 170 provides high sensitivity and specificity in RNA variant calling down to 5 copies of transcript per ng of input.
Learn More"
"Illumina/TruSight Myeloid Sequencing Panel (96 samples)/FC-130-1010/1 Ea
" FC-130-1010 Illumina 產(chǎn)品編號: FC-130-1010美 元 價: $0.00會 員 價: 待定品 牌: Illumina產(chǎn) 地: 美國公 司: Illumina, Inc.產(chǎn)品分類: 其它>其它試劑>芯片公司分類: Clinical Research Products "Product Highlights:
The TruSight Myeloid Sequencing Panel uses expert-defined content and proven next-generation sequencing (NGS) technology to identify somatic variants in myeloid malignancies.
The panel content was designed by a consortium of recognized experts in blood cancer disorders and targets genes frequently mutated in:
Acute myeloid leukemia (AML)
Myelodysplastic syndrome (MDS)
Myeloproliferative neoplasms (MPN)
Chronic myelogenous leukemia (CML)
Chronic myelomonocytic leukemia (CMML)
Juvenile myelomonocytic leukemia (JMML)
The TruSight Myeloid Sequencing Panel covers 15 full genes (exons only) and 39 additional genes where oncogenic hotspots are covered, providing a comprehensive assessment of the key genes known to be involved in myeloid malignancies in a single test. The result is an accurate, cost-effective solution that enables researchers to profile liquid tumors.
View the gene list
TruSight Myeloid libraries are ideally suited to run on a desktop sequencer and perform alignment and variant calling with the MiSeq Reporter or Local Run Manager Amplicon workflow with Somatic Variant Caller. Filtering and annotation can then be performed using the following Illumina annotation and filtering tools: BaseSpace Variant Interpreter or VariantStudio.
Specifications:
Assay Time 8 hours
Hands-On Time 3 hours
Input Quantity 50 ng
System Compatibility MiSeq,MiSeqDx in Research Mode,MiniSeq,NextSeq 500
Technology Sequencing
Variant Class Somatic Variants,Insertions-Deletions (indels)
Species Category Human
Cancer Type Hematological
Method Amplicon Sequencing,Targeted DNA Sequencing"
"Illumina/TruSeq Amplicon - Cancer Panel (96 samples)/FC-130-1008/1 Ea
" FC-130-1008 Illumina 產(chǎn)品編號: FC-130-1008美 元 價: $0.00會 員 價: 待定品 牌: Illumina產(chǎn) 地: 美國公 司: Illumina, Inc.產(chǎn)品分類: 其它>其它試劑>芯片公司分類: Clinical Research Products "Product Highlights:
The TruSeq Amplicon - Cancer Panel enables highly sensitive mutation detection studies of important cancer-related genes, including BRAF, KRAS, and EGFR. Mutations in these genes are linked to many cancers, including melanoma, colorectal, ovarian, and lung cancer.
This cancer sequencing panel provides:
A streamlined workflow including an integrated quality control assay for formalin-fixed, paraffin-embedded (FFPE) DNA
Simple sample normalization
Automated cluster generation and paired-end sequencing
On-instrument data analysis
The unique ABIlity of this assay to screen precious FFPE samples for these important variants will unlock a wealth of genomic information for many tumor types.
Genes in the TruSeq Amplicon - Cancer Panel
See which cancer-related genes are represented in this panel.
View Gene List
Specifications:
Assay Time 8 hours
Hands-On Time 3.5 hours
Input Quantity 150 ng high-quality genomic DNA,250 ng FFPE genomic DNA
System Compatibility MiSeq,MiSeqDx in Research Mode,MiniSeq
Specialized Sample Types FFPE
Technology Sequencing
Variant Class Somatic Variants,Insertions-Deletions (indels)
Species Category Human
Cancer Type Pan-Cancer
Method Amplicon Sequencing,Targeted DNA Sequencing"
"Illumina/TruSight Rapid Capture (2 indexes, 8 samples, 4 enrichments)/FC-140-1102/1 Ea
" FC-140-1102 Illumina 產(chǎn)品編號: FC-140-1102美 元 價: $0.00會 員 價: 待定品 牌: Illumina產(chǎn) 地: 美國公 司: Illumina, Inc.產(chǎn)品分類: 其它>其它試劑>芯片公司分類: Clinical Research Products "Product Highlights:
Targeting genes previously linked to a predisposition towards cancer.
Developed in collaboration with Professor Nazneen Rahman and team at the Institute of Cancer Research (ICR), London
Targets 94 genes and 284 SNPs associated with a predisposition towards cancer
TruSight Cancer includes genes associated with both common (e.g., breast, colorectal) and rare cancers. In addition, the set includes 284 SNPs found to correlate with cancer through genome-wide association studies (GWAS). Content selection was based on expert curation of the scientific literature and other high-quality resources.
The TruSight Cancer sequencing panel provides custom oligos targeting identified regions of interest. Sufficient product is supplied for four enrichment reactions. TruSight Cancer is compatIBLe with TruSight Rapid Capture.
TruSight Cancer Sample Datasets
6 human reference samples were prepared using the TruSight Cancer sequencing panel. These libraries were sequenced on the MiniSeq System using a high output kit at a 2 x 100 bp read length configuration with dual indexing. The total yield was 5.2 Gb with 95.8% of bases at or above Q30.
Browse the data in BaseSpace Sequence Hub:
View Run
View Project
* Note that access to this data requires a BaseSpace Sequence Hub login.
Register for BaseSpace Sequence Hub
Specifications:
Assay Time 1.5 days
Input Quantity 50 ng
System Compatibility MiSeq,NextSeq 550,MiSeqDx in Research Mode,MiniSeq,NextSeq 500
Specialized Sample Types Low Input
Technology Sequencing
Species Category Human
Variant Class Germline Variants
Cancer Type Pan-Cancer
Method Targeted DNA Sequencing
"
"Illumina/TruSight Tumor 170 Kit, For Use with NextSeq plus Watson for Genomics/20018621/1 Ea
" 20018621 Illumina 產(chǎn)品編號: 20018621美 元 價: $0.00會 員 價: 待定品 牌: Illumina產(chǎn) 地: 美國公 司: Illumina, Inc.產(chǎn)品分類: 其它>其它試劑>芯片公司分類: Clinical Research Products "Product Highlights:
TruSight Tumor 170, a next-generation sequencing assay designed to cover 170 genes associated with common solid tumors, is an enrichment-based targeted panel that simultaneously analyzes DNA and RNA, covering a wide range of genes and variant types. The comprehensive nature provides laboratories with a deep view into the genetics of cancer.
Comprehensive Coverage of Cancer-Related Variants
Assessment of fusions, splice variants, insertions/deletions and single-nucleotide variants (SNVs), and amplifications in one assay using DNA and RNA creates efficiencies in sample usage, time, and cost.
Accurate Results from Low-Quality Samples1
Variant detection with as little as 40 ng DNA and RNA input, and as low as 5% mutant allele frequency, maximizes the results from precious formalin-fixed paraffin-embedded (FFPE) samples.
Integrated, Streamlined Workflow
DNA and RNA are prepared in parallel with an integrated workflow following DNA shearing/CDNA synthesis.
Specifications:
Assay Time ~2 days (Library Prep)
Hands-On Time ~10.5 hours
Input Quantity 40 ng DNA and/or RNA
Method Targeted RNA Sequencing,Targeted DNA Sequencing
Variant Class Single Nucleotide Polymorphisms (SNPs),Gene Fusions,Somatic Variants,Structural Variants,Insertions-Deletions (indels),Copy Number Variants (CNVs)
Specialized Sample Types FFPE,Low Input
System Compatibility NextSeq 550,NextSeq 500,HiSeq 2500
Technology Sequencing
Species Category Human
Cancer Type Solid Tumor
Scientific Posters:
AACR 2017: TruSight Tumor 170 and Tumor Mutational Burden
Results of analysis indicate that TruSight Tumor 170, with comprehensive coverage of cancer-related genes, shows high concordance with whole exome sequencing for accurate assessment of tumor mutational burden.
Learn More
AACR 2017: TruSight Tumor 170 and Solid Tumor Profiling Analytical Performance with FFPE Samples
Standard extractions from FFPE embedded samples provide sufficient material (40ng) in >95% of samples that were extracted by Illumina. This data shows that the TruSight Tumor 170 panel is a robust assay that generates passing sample QC data in >85% of samples with varying quality, and in >95% of samples that have quality metrics that fall within the recommendations for the kit.
Learn More
AACR 2017: TruSight Tumor 170 for Small Nucleotide Variations and Gene Amplifications in FFPE DNA Samples
TruSight Tumor 170 can achieve high sensitivity and specificity for the detection of somatic variants (small variants and CNVs) from DNA extracted from FFPE tissues.
Learn More
AACR 2017: TruSight Tumor 170 for Fusions and Splice Variants in FFPE RNA Tumor Samples
Through examining limit of detection in the context of RNA expression, this study shows that TruSight Tumor 170 provides high sensitivity and specificity in RNA variant calling down to 5 copies of transcript per ng of input.
Learn More"
"Illumina/TruSight RNA Pan-Cancer Panel Set A/RS-303-1002/1 Ea
" RS-303-1002 Illumina 產(chǎn)品編號: RS-303-1002美 元 價: $0.00會 員 價: 待定品 牌: Illumina產(chǎn) 地: 美國公 司: Illumina, Inc.產(chǎn)品分類: 其它>其它試劑>芯片公司分類: Clinical Research Products "Product Highlights:
The TruSight RNA Pan-Cancer panel provides a comprehensive analysis of the cancer transcriptome. It offers:
Gene expression information, variant calling, and fusion detection with known and novel gene fusion partners
Optimized, low-input protocol for a wide range of sample types including FFPE
A comprehensive view of cancer pathways
Economical RNA sequencing (RNA-Seq) on a desktop sequencer
Highly Sensitive and Economical Targeted Sequencing
The TruSight RNA Pan-Cancer panel enables the quantitative measurement of gene expression as well as the detection of gene fusions with both known and novel gene fusion partners. The panel accommodates as little as 10 ng of total RNA input (or 20 ng from FFPE samples). The focus on a subset of relevant genes enables RNA-Seq with high sensitivity at 8 samples per run on a desktop sequencer, allowing cost-effective access to NGS for any lab.
Intuitive Cloud-based Data Analysis
Analysis can be performed using the RNA-Seq Alignment BaseSpace App. This intuitive tool performs fusion calling andvariant detection, and provides gene expression profiles, offering a comprehensive solution to all cancer researchers.
TruSight RNA Pan-Cancer Sample Datasets
MiSeq Data
10 ng of human reference RNA (UHR), human reference brain RNA (Brain), cell line RNA (MCF7), and 20 ng of breast tumor FFPE RNA (BT) were prepared using the TruSight RNA Pan-Cancer Panel and sequenced on the MiSeq System. Read mapping and fusion calling were performed using the RNA-Seq Alignment App with STAR aligner on BaseSpace Sequence Hub.
View Project
MiniSeq Data
Human reference RNA (HBRR and UHRR), cell line RNA (MCF7), and breast tumor RNA samples were prepared using the TruSight RNA Pan-Cancer panel, and 8 samples were sequenced on the MiniSeq System at a 2x76bp read length with single indexing. The total yield was 4.2 Gb with 96.8% of bases at or above Q30.
Browse the data in BaseSpace Sequence Hub:
View Run
View Project
Access to this data requires a BaseSpace Sequence Hub login.
Register for BaseSpace Sequence Hub
Specifications:
Assay Time 2.5 days
Hands-On Time 11 hours
Input Quantity 10 ng total RNA,20 - 100 ng FFPE RNA
System Compatibility MiSeq,NextSeq 550,MiSeqDx in Research Mode,MiniSeq,NextSeq 500
Method Targeted RNA Sequencing,Sequencing for Cytogenomics
Variant Class Gene Fusions,Somatic Variants,Novel Transcripts,Transcript Variants
Specialized Sample Types FFPE,Low Input
Technology Sequencing
Species Category Human
Cancer Type Pan-Cancer
"
"Illumina/TruSight Inherited Disease Sequencing Panel (48 samples)/FC-121-0205/1 Ea
" FC-121-0205 Illumina 產(chǎn)品編號: FC-121-0205美 元 價: $0.00會 員 價: 待定品 牌: Illumina產(chǎn) 地: 美國公 司: Illumina, Inc.產(chǎn)品分類: 其它>其它試劑>芯片公司分類: Clinical Research Products "Product Highlights:
Developed in collaboration with Dr. Stephen Kingsmore and team during his tenure at Children's Mercy Hospital (CMH) for Pediatric Genomic Medicine, Dr. Carol Saunders at CMH, and Dr. Hilger Ropers at the Max Planck Institute
Targets 552 genes, including coding exons, intron-exon boundaries, and regions known to harbor pathogenic mutations
TruSight Inherited Disease was initially based on a 448 disease panel designed for preconception carrier testing for severe, recessive childhood diseases published by Dr. Kingsmore and team in Science Translational Medicine1.
The original content was revised by Dr. Saunders, FACMG, at CMH (following ACMG guidelines for testing ultra-rare genetic diseases) to reflect the needs of medical geneticists with a primary focus on severe recessive diseases with childhood onset. Intellectual disABIlity genes were added by Dr. Ropers.
The TruSight Inherited Disease sequencing panel set includes custom oligos targeting identified regions of interest. Sufficient product is supplied for four enrichment reactions.
Specifications:
Input Quantity 50 ng DNA
System Compatibility MiSeq,NextSeq 550,MiSeqDx in Research Mode,MiniSeq,NextSeq 500,HiSeq 2500
Variant Class Single Nucleotide Polymorphisms (SNPs),Germline Variants
Specialized Sample Types Low Input
Technology Sequencing
Species Category Human
Method Targeted DNA Sequencing
"
"Illumina/TruSight Tumor 15 (Library Prep Only)/OP-101-1002/1 Ea
" OP-101-1002 Illumina 產(chǎn)品編號: OP-101-1002美 元 價: $0.00會 員 價: 待定品 牌: Illumina產(chǎn) 地: 美國公 司: Illumina, Inc.產(chǎn)品分類: 其它>其它試劑>芯片公司分類: Clinical Research Products "Product Highlights:
TruSight Tumor 15 uses next-generation sequencing (NGS) technology to provide a comprehensive assessment of 15 genes that are commonly mutated in solid tumors. It accurately detects low-frequency variants from 20 ng of starting DNA and is optimized for formalin-fixed, paraffin-embedded (FFPE) tumor tissue.
View the Gene List
Featuring a rapid workflow that can be easily integrated into lab procedures, this panel offers a single assay for accurate, economical, and rapid analysis of solid tumors.
This TruSight Tumor panel offers:
Comprehensive workflow: Assess 15 genes with one simple workflow instead of single, iterative gene testing with polymerase chain reaction (PCR)
Efficient: Rapid turnaround with only 3.5 hours of hands-on time, going from DNA to data in approximately 36 hours
Relevant gene content for solid tumors: Somatic variants selected from relevant industry guidelines1,2, key opinion leaders3,4, and pharmaceutical research
Sensitive variant detection from low DNA input: Accurate somatic variant detection of 5% allele frequency using 20 ng DNA from FFPE tissue samples
TruSight Tumor 15 Sample Datasets
3 human reference samples and 5 FFPE-exacted DNA samples from lung, colon, melanoma, and breast tumors were prepared using TruSight Tumor 15. These libraries were sequenced on the MiniSeq System using a high output kit at a 2 x 150 bp read length configuration with dual indexing. The total yield was 7.6 Gb with 94.9% of bases at or above Q30.
Browse the data in BaseSpace Sequence Hub:
View Run
View Project
Access to this data requires a BaseSpace Sequence Hub login.
Register for BaseSpace Sequence Hub
Specifications:
Assay Time 7 hours
Hands-On Time 3.5 hours
Input Quantity 20 ng
System Compatibility MiSeq,MiSeqDx in Research Mode,MiniSeq
Specialized Sample Types FFPE,Low Input
Technology Sequencing
Variant Class Somatic Variants,Insertions-Deletions (indels)
Species Category Human
Cancer Type Solid Tumor
Method Amplicon Sequencing,Targeted DNA Sequencing
"
"Illumina/TruSight RNA Fusion Panel Set B (48 samples)/RS-304-1003/1 Ea
" RS-304-1003 Illumina 產(chǎn)品編號: RS-304-1003美 元 價: $0.00會 員 價: 待定品 牌: Illumina產(chǎn) 地: 美國公 司: Illumina, Inc.產(chǎn)品分類: 其它>其它試劑>芯片公司分類: Clinical Research Products "Product Highlights:
This targeted RNA sequencing panel is a cost-effective solution to detect gene fusions in multiple cancer types, regardless of origin. Covering 507 fusion-associated genes, a single assay enables researchers to assess most known cancer-related fusions in blood, bone marrow, and FFPE samples, with the power to identify novel fusion gene partners.
Industry-validated content for a comprehensive view of cancer-related fusion genes, detecting common and novel fusions
From RNA to results in 4 days including on-instrument software that displays fusion calls
Compatibility with desktop sequencers to maximize lab budgets
Optimized RNA sequencing for all sample types, including FFPE tissues
Simple Fusion Report for Customers New to NGS
On-instrument fusion calling provides NGS-based fusion detection to labs without additional bioinformatics support. The analysis provides a list of detected fusions, relevant disease associations (as identified by the Mitelman database), and evidence of fusion-supporting reads.
Robust, ReproducIBLe, and Low-Input Fusion Assay
This assay accommodates as little input as 20 ng FFPE RNA or 10 ng fresh-frozen total RNA. The TruSight RNA Fusion Panel provides a sensitive, reproducIBLe, and economical solution for studies of gene fusions in cancer research.
Specifications:
Assay Time 2.5 days
Hands-On Time 11 hours
Input Quantity 10 ng total RNA, 20–100 ng FFPE RNA
System Compatibility MiSeq,NextSeq 550,MiSeqDx in Research Mode,MiniSeq,NextSeq 500
Method Targeted RNA Sequencing,Sequencing for Cytogenomics
Variant Class Gene Fusions
Specialized Sample Types FFPE,Low Input
Technology Sequencing
Species Category Human
Cancer Type Pan-Cancer"
"Illumina/TruSight Tumor 15 MiSeq Kit/OP-101-1001/1 Ea
" OP-101-1001 Illumina 產(chǎn)品編號: OP-101-1001美 元 價: $0.00會 員 價: 待定品 牌: Illumina產(chǎn) 地: 美國公 司: Illumina, Inc.產(chǎn)品分類: 其它>其它試劑>芯片公司分類: Clinical Research Products "Product Highlights:
TruSight Tumor 15 uses next-generation sequencing (NGS) technology to provide a comprehensive assessment of 15 genes that are commonly mutated in solid tumors. It accurately detects low-frequency variants from 20 ng of starting DNA and is optimized for formalin-fixed, paraffin-embedded (FFPE) tumor tissue.
View the Gene List
Featuring a rapid workflow that can be easily integrated into lab procedures, this panel offers a single assay for accurate, economical, and rapid analysis of solid tumors.
This TruSight Tumor panel offers:
Comprehensive workflow: Assess 15 genes with one simple workflow instead of single, iterative gene testing with polymerase chain reaction (PCR)
Efficient: Rapid turnaround with only 3.5 hours of hands-on time, going from DNA to data in approximately 36 hours
Relevant gene content for solid tumors: Somatic variants selected from relevant industry guidelines1,2, key opinion leaders3,4, and pharmaceutical research
Sensitive variant detection from low DNA input: Accurate somatic variant detection of 5% allele frequency using 20 ng DNA from FFPE tissue samples
TruSight Tumor 15 Sample Datasets
3 human reference samples and 5 FFPE-exacted DNA samples from lung, colon, melanoma, and breast tumors were prepared using TruSight Tumor 15. These libraries were sequenced on the MiniSeq System using a high output kit at a 2 x 150 bp read length configuration with dual indexing. The total yield was 7.6 Gb with 94.9% of bases at or above Q30.
Browse the data in BaseSpace Sequence Hub:
View Run
View Project
Access to this data requires a BaseSpace Sequence Hub login.
Register for BaseSpace Sequence Hub
Specifications:
Assay Time 7 hours
Hands-On Time 3.5 hours
Input Quantity 20 ng
System Compatibility MiSeq,MiSeqDx in Research Mode,MiniSeq
Specialized Sample Types FFPE,Low Input
Technology Sequencing
Variant Class Somatic Variants,Insertions-Deletions (indels)
Species Category Human
Cancer Type Solid Tumor
Method Amplicon Sequencing,Targeted DNA Sequencing"
"Illumina/TruSight Cancer MiniSeq Kit/20005612/1 Ea
" 20005612 Illumina 產(chǎn)品編號: 20005612美 元 價: $0.00會 員 價: 待定品 牌: Illumina產(chǎn) 地: 美國公 司: Illumina, Inc.產(chǎn)品分類: 其它>其它試劑>芯片公司分類: Clinical Research Products "Product Highlights:
Targeting genes previously linked to a predisposition towards cancer.
Developed in collaboration with Professor Nazneen Rahman and team at the Institute of Cancer Research (ICR), London
Targets 94 genes and 284 SNPs associated with a predisposition towards cancer
TruSight Cancer includes genes associated with both common (e.g., breast, colorectal) and rare cancers. In addition, the set includes 284 SNPs found to correlate with cancer through genome-wide association studies (GWAS). Content selection was based on expert curation of the scientific literature and other high-quality resources.
The TruSight Cancer sequencing panel provides custom oligos targeting identified regions of interest. Sufficient product is supplied for four enrichment reactions. TruSight Cancer is compatIBLe with TruSight Rapid Capture.
TruSight Cancer Sample Datasets
6 human reference samples were prepared using the TruSight Cancer sequencing panel. These libraries were sequenced on the MiniSeq System using a high output kit at a 2 x 100 bp read length configuration with dual indexing. The total yield was 5.2 Gb with 95.8% of bases at or above Q30.
Browse the data in BaseSpace Sequence Hub:
View Run
View Project
* Note that access to this data requires a BaseSpace Sequence Hub login.
Register for BaseSpace Sequence Hub
Specifications:
Assay Time 1.5 days
Input Quantity 50 ng
System Compatibility MiSeq,NextSeq 550,MiSeqDx in Research Mode,MiniSeq,NextSeq 500
Specialized Sample Types Low Input
Technology Sequencing
Species Category Human
Variant Class Germline Variants
Cancer Type Pan-Cancer
Method Targeted DNA Sequencing
"
"Illumina/TruSight Rapid Capture (96 indexes, 288 samples, 24 enrichments)/FC-140-1106/1 Ea
" FC-140-1106 Illumina 產(chǎn)品編號: FC-140-1106美 元 價: $0.00會 員 價: 待定品 牌: Illumina產(chǎn) 地: 美國公 司: Illumina, Inc.產(chǎn)品分類: 其它>其它試劑>芯片公司分類: Clinical Research Products "Product Highlights:
Targeting genes previously linked to a predisposition towards cancer.
Developed in collaboration with Professor Nazneen Rahman and team at the Institute of Cancer Research (ICR), London
Targets 94 genes and 284 SNPs associated with a predisposition towards cancer
TruSight Cancer includes genes associated with both common (e.g., breast, colorectal) and rare cancers. In addition, the set includes 284 SNPs found to correlate with cancer through genome-wide association studies (GWAS). Content selection was based on expert curation of the scientific literature and other high-quality resources.
The TruSight Cancer sequencing panel provides custom oligos targeting identified regions of interest. Sufficient product is supplied for four enrichment reactions. TruSight Cancer is compatIBLe with TruSight Rapid Capture.
TruSight Cancer Sample Datasets
6 human reference samples were prepared using the TruSight Cancer sequencing panel. These libraries were sequenced on the MiniSeq System using a high output kit at a 2 x 100 bp read length configuration with dual indexing. The total yield was 5.2 Gb with 95.8% of bases at or above Q30.
Browse the data in BaseSpace Sequence Hub:
View Run
View Project
* Note that access to this data requires a BaseSpace Sequence Hub login.
Register for BaseSpace Sequence Hub
Specifications:
Assay Time 1.5 days
Input Quantity 50 ng
System Compatibility MiSeq,NextSeq 550,MiSeqDx in Research Mode,MiniSeq,NextSeq 500
Specialized Sample Types Low Input
Technology Sequencing
Species Category Human
Variant Class Germline Variants
Cancer Type Pan-Cancer
Method Targeted DNA Sequencing"
"Illumina/TruSight One Sequencing Kit (9 samples)/FC-141-1006/1 Ea
" FC-141-1006 Illumina 產(chǎn)品編號: FC-141-1006美 元 價: $0.00會 員 價: 待定品 牌: Illumina產(chǎn) 地: 美國公 司: Illumina, Inc.產(chǎn)品分類: 其它>其它試劑>芯片公司分類: Clinical Research Products "Product Highlights:
TruSight One Sequencing Panels enable labs to expand and streamline their sequencing portfolio, while managing costs.
Two panels offer options to target up to 6700 genes associated with human disease, with high coverage
Single assay includes multiple genes of interest, replacing iterative testing
Easy, flexIBLe gene filtering and annotation options simplify BIOLOGical interpretation and reporting
These panels provide clinical research labs with an affordable solution for managing a diverse assay portfolio. The TruSight One Sequencing Panel provides comprehensive coverage of > 4800 disease-associated genes, while the TruSight One Expanded Sequencing Panel targets ~1900 additional genes with recent disease associations in the scientific literature. Investigators can choose to analyze all of the genes on the panel or focus on a specific subset. With a single assay, labs can expand existing menus, streamline workflows, or create an entire portfolio of sequencing options.
Specifications:
Input Quantity 50 ng
Content Specifications ~12 Mb genomic content for TruSight One; ~16.5 Mb genomic content for TruSight One Expanded
Multiplexing Up to 96-plex
System Compatibility MiSeq,NextSeq 550,HiSeq 3000,MiSeqDx in Research Mode,MiniSeq,NextSeq 500,HiSeq 2500,NovaSeq 6000,HiSeq 4000
Variant Class Single Nucleotide Polymorphisms (SNPs),Germline Variants
Specialized Sample Types Low Input
Technology Sequencing
Species Category Human
Method Targeted DNA Sequencing
"
"Illumina/TruSight One Sequencing Panel (36 samples)/FC-141-1007/1 Ea
" FC-141-1007 Illumina 產(chǎn)品編號: FC-141-1007美 元 價: $0.00會 員 價: 待定品 牌: Illumina產(chǎn) 地: 美國公 司: Illumina, Inc.產(chǎn)品分類: 其它>其它試劑>芯片公司分類: Clinical Research Products "Product Highlights:
TruSight One Sequencing Panels enable labs to expand and streamline their sequencing portfolio, while managing costs.
Two panels offer options to target up to 6700 genes associated with human disease, with high coverage
Single assay includes multiple genes of interest, replacing iterative testing
Easy, flexIBLe gene filtering and annotation options simplify BIOLOGical interpretation and reporting
These panels provide clinical research labs with an affordable solution for managing a diverse assay portfolio. The TruSight One Sequencing Panel provides comprehensive coverage of > 4800 disease-associated genes, while the TruSight One Expanded Sequencing Panel targets ~1900 additional genes with recent disease associations in the scientific literature. Investigators can choose to analyze all of the genes on the panel or focus on a specific subset. With a single assay, labs can expand existing menus, streamline workflows, or create an entire portfolio of sequencing options.
Specifications:
Input Quantity 50 ng
Content Specifications ~12 Mb genomic content for TruSight One; ~16.5 Mb genomic content for TruSight One Expanded
Multiplexing Up to 96-plex
System Compatibility MiSeq,NextSeq 550,HiSeq 3000,MiSeqDx in Research Mode,MiniSeq,NextSeq 500,HiSeq 2500,NovaSeq 6000,HiSeq 4000
Variant Class Single Nucleotide Polymorphisms (SNPs),Germline Variants
Specialized Sample Types Low Input
Technology Sequencing
Species Category Human
Method Targeted DNA Sequencing
"
Illumina/TruSeq Stranded mRNA Library Prep Kit High Throughput (96 samples, 96 indexes)/RS-122-2103/1 Ea RS-122-2103 Illumina 產(chǎn)品編號: RS-122-2103美 元 價: $4700.00會 員 價: 待定品 牌: Illumina產(chǎn) 地: 美國公 司: Illumina, Inc.產(chǎn)品分類: 分子類>二代測序>DNA文庫制備試劑盒公司分類: Library Preparation Kits "Product Highlights:
The TruSeq Stranded mRNA Library Prep Kit offers a streamlined, cost-efficient, and scalable solution for coding transcriptome analysis. It is compatIBLe with a wide range of samples.
Precise and Accurate
Get precise measurement of mRNA strand orientation for detection of antisense transcription, enhanced transcript annotation, and increased alignment efficiency. High coverage uniformity enhances the discovery of features such as alternative transcripts, gene fusions, and allele-specific expression.
Cost-Efficient
Stranded information identifies from which of the 2 DNA strands a given RNA transcript was derived. This information provides increased confidence in transcript annotation, particularly for nonhuman samples. Identifying strand origin increases the percentage of reads that align, reducing sequencing costs per sample.
Scalable
The kit enables robust interrogation of both standard and low-quality samples, and workflows compatIBLe with a wide range of study designs.
Find an up-to-date list of high-throughput automation vendors with robotic systems compatIBLe with this library preparation kit
Specifications:
Assay Time ~10.5 hours
Hands-On Time ~4.5 hours
Input Quantity 0.1 – 1 ug total RNA or 10 - 100 ng previously isolated mRNA (from species with polyA tails)
Content Specifications Captures the coding transcriptome with strand information
Mechanism of Action Oligo-dT beads capture polyA tails
System Compatibility NovaSeq 5000,Genome Analyzer IIx,HiSeq 2000,MiSeq,NextSeq 550,HiSeq 3000,HiSeq 1000,HiSeq 1500,NextSeq 500,HiSeq 2500,NovaSeq 6000,HiSeq 4000
Species Category Other,Mammalian,Bovine,Mouse,Human,Rat
Variant Class Single Nucleotide Polymorphisms (SNPs),Gene Fusions,Novel Transcripts,Transcript Variants
Technology Sequencing
Method mRNA Sequencing
Automation CapABIlity Liquid Handling Robots"
Illumina/Nextera Rapid Capture Exome (8 rxn x 12 plex)/FC-140-1003/1 Ea FC-140-1003 Illumina 產(chǎn)品編號: FC-140-1003美 元 價: $10290.00會 員 價: 待定品 牌: Illumina產(chǎn) 地: 美國公 司: Illumina, Inc.產(chǎn)品分類: 分子類>二代測序>DNA文庫制備試劑盒公司分類: Library Preparation Kits "Product Highlights:
The Nextera Rapid Capture Exome and Expanded Exome are all-in-one kits for library preparation and exome enrichment that allow researchers to identify coding variants up to 70% faster than other methods. This optimized exome delivers 45 Mb of expertly selected exonic content and requires as little as 4 Gb of sequencing.
Extend coverage to UTRs and miRNA with Expanded Exome
Nextera Rapid Capture Expanded Exome delivers 62 Mb of genomic content, including exons, untranslated regions (UTRs), and miRNA. This kit features a highly optimized probe set that delivers comprehensive coverage of exonic sequence.
Illumina provides example data sets to demonstrate the high uniformity and accuracy of the Nextera Rapid Capture Exome library prep kit. View the exome sequencing data.
Add on custom content to make Nextera Rapid Capture Exome even more powerful
Researchers can define custom content for this workflow using Nextera Rapid Capture Custom Enrichment. This custom assay allows researchers to rapidly interrogate those portions of the human genome most important to their specific research. Choose from a fully custom design or start from a defined content set, such as Nextera Rapid Capture Exome, and include areas of interest using add-on functionality. Learn More.
Find an up-to-date list of high-throughput automation vendors with robotic systems compatIBLe with this library preparation kit
Specifications:
Assay Time 5 hours total assay time
Hands-On Time 4 hours
Input Quantity 1 ug DNA (compatIBLe with most large DNA genomes)
Mechanism of Action Mechanical fragmentation
Multiplexing Up to 96 dual-index combinations with HT (high-throughput) kit
Variant Class Small Insertions-Deletions (indels)
System Compatibility HiSeq 2000,NextSeq 550,HiSeq 3000,NextSeq 500,HiSeq 2500,HiSeq 4000
Specialized Sample Types Low Input
Technology Sequencing
Species Category Human
Automation CapABIlity Liquid Handling Robots
Method Exome Sequencing
"
Illumina/20-pack MiSeq Reagent Kit v2 (300-cycles)/MS-102-2022/1 Ea MS-102-2022 Illumina 產(chǎn)品編號: MS-102-2022美 元 價: $19900.00會 員 價: 待定品 牌: Illumina產(chǎn) 地: 美國公 司: Illumina, Inc.產(chǎn)品分類: 分子類>二代測序>簇生成和測序試劑公司分類: Cluster Generation & Sequencing Reagents "Product Highlights:
MiSeq Reagent Kits v2 enable more output to simplify each MiSeq run. MiSeq Reagent Kits v2 retain the same pre-filled, ready-to-use reagent cartridges as the v1 kits, but offer improved chemistry to increase cluster density, decrease cycle time, and improve quality (Q) scores. MiSeq Reagent Kits v2 are also available in micro and nano formats for low output applications.
Get faster cycle times, longer reads and more output from improved chemistry
Dual surface imaging enables twice the number of reads compared to single surface imaging with the v1 kit
Extend your read lengths with the 500-cycle kit
Choose the perfect number of cycles for your application (50, 300, or 500)
When coupled with the MiSeq System upgrade, the MiSeq Reagent Kits v2 allow dual surface imaging to double the amount of readable space per flow cell. MiSeq Regent Kits v2 are available in a 500-cycle format for long read lengths, as well as in the popular 50-cycle and 300-cycle formats.
MiSeq Reagent Kits v2 are available in standard, micro, and nano configurations, enabling alignment to specific project requirements and scalable levels of output.
View product configurations
All MiSeq reagent components are RFID-encoded and interact intelligently with the MiSeq System to validate compatibility with user-defined applications.
A MiSeq Reagent Kit v3 is also available. It offers a 600-cycle format to allow the longest read lengths on any Illumina sequencing system, or a 150-cycle format that enables counting applications.
Specifications:
Maximum Output 8.5 Gb (500-cycle MiSeq Reagent Kit v2), 5.1 Gb (300-cycle MiSeq Reagent Kit v2), 1.2 Gb (300-cycle MiSeq Reagent Micro Kit v2), 0.850 Gb (50-cycle MiSeq Reagent Kit v2), 0.5 Gb (500-cycle MiSeq Reagent Nano Kit v2), 0.3 Gb (300-cycle MiSeq Reagent Nano Kit v2)
Maximum Reads per Run Up to 15 million
Reagent Type Paired-End Sequencing,Cluster Generation,Sequencing by Synthesis
System Compatibility MiSeq,MiSeqDx in Research Mode,MiSeq FGx in Research Mode
Technology Sequencing"
Illumina/Nextera DNA Library Prep Kit (96 samples)/FC-121-1031/1 Ea FC-121-1031 Illumina 產(chǎn)品編號: FC-121-1031美 元 價: $7283.00會 員 價: 待定品 牌: Illumina產(chǎn) 地: 美國公 司: Illumina, Inc.產(chǎn)品分類: 分子類>二代測序>DNA文庫制備試劑盒公司分類: Library Preparation Kits "Product Highlights:
Nextera DNA Library Preparation Kits provide a fast and easy workflow, enabling sequencing-ready libraries to be generated in less than 90 minutes, with less than 15 minutes of hands-on time. Samples prepared with Nextera kits are compatIBLe with all Illumina sequencers.
With Nextera technology, DNA is simultaneously fragmented and tagged with sequencing adapters in a single step, using standard lab equipment. Ideal for precious samples available in limited quantity, the protocol requires only 50 ng of DNA input.
See a list of automation vendors with robotic systems compatIBLe with this kit
Specifications:
Assay Time 90 minutes
Hands-On Time 15 minutes
Input Quantity 50 ng genomic DNA (compatIBLe with most large DNA genomes)
Mechanism of Action Enzymatic Fragmentation
Multiplexing Up to 96 available indexes
Species Category Human,Other,Mammalian,Mouse,Rat,Plant
Species Details CompatIBLe with most large DNA genomes.
System Compatibility MiSeq,NextSeq 550,HiSeq 3000,MiniSeq,NextSeq 500,HiSeq 2500,HiSeq 4000
Variant Class Single Nucleotide Polymorphisms (SNPs),Structural Variants,Insertions-Deletions (indels)
Method Whole-Genome Sequencing
Technology Sequencing
Automation CapABIlity Liquid Handling Robots"
"Illumina/TruSeq RNA Library Preparation Kit v2, Set A (48 samples, 12 indexes)/RS-122-2001/1 Ea
" Illumina 產(chǎn)品編號: RS-122-2001美 元 價: $3591.00會 員 價: 待定品 牌: Illumina產(chǎn) 地: 美國公 司: Illumina, Inc.產(chǎn)品分類: 分子類>二代測序>DNA文庫制備試劑盒公司分類: Library Preparation Kits "Product Highlights:
Generate mRNA-focused sequencing libraries from total RNA, with enhanced multiplex capABIlity and a simplified workflow with master-mixed reagents.
Kits feature 24 unique indexes, delivering enhanced multiplex performance for processing large numbers of samples (including up to 384 RNA-Seq samples on a single HiSeq 2500 System run).
Master-mixed reagents eliminate the majority of pipetting steps and reduce the amount of clean-up, as compared to previous methods, minimizing hands-on time. This results in economical, high-throughput RNA sequencing studies achieved with the easiest-to-use sample preparation workflow offered by any NGS platform.
Find an up-to-date list of high-throughput automation vendors with robotic systems compatIBLe with this library preparation kit
Specifications:
Assay Time ~10.5 hours
Hands-On Time ~4.5 hours
Input Quantity 0.1 - 1 ug total RNA or 10 - 400 ng previously isolated mRNA (from species with polyA tails)
Content Specifications Captures the coding transcriptome (without strand information)
Mechanism of Action Oligo-dT beads capture polyA tails
Multiplexing Up to 24-plex per lane
System Compatibility Genome Analyzer IIx,HiSeq 2000,MiSeq,NextSeq 550,HiSeq 3000,HiSeq 1000,HiSeq 1500,NextSeq 500,HiSeq 2500,HiSeq 4000
Species Category Other,Mammalian,Bovine,Mouse,Human,Rat
Variant Class Single Nucleotide Polymorphisms (SNPs),Gene Fusions,Novel Transcripts,Transcript Variants
Technology Sequencing
Method mRNA Sequencing
Automation CapABIlity Liquid Handling Robots"
"Illumina/TruSeq FFPE DNA Library Prep QC Kit (24 samples)/FC-121-9999/1 Ea
" Illumina 產(chǎn)品編號: FC-121-9999美 元 價: $155.00會 員 價: 待定品 牌: Illumina產(chǎn) 地: 美國公 司: Illumina, Inc.產(chǎn)品分類: 分子類>二代測序>DNA文庫制備試劑盒公司分類: Library Preparation Kits "Product Highlights:
The TruSeq Custom Amplicon Low Input Library Prep Kit is a scalable amplicon sequencing solution that delivers sensitive and specific results from both low-input and formalin-fixed, paraffin-embedded (FFPE) DNA samples. It offers:
Accurate variant detection from as low as 10 ng of input genomic DNA (gDNA) and challenging FFPE samples
Fully supported, optimized workflow solution including simple data analysis
Automation-friendly workflow that can be completed in 6 hours, with only 3 hours of hands-on time
Low DNA Input and FFPE Compatibility
The TruSeq Custom Amplicon Low Input Library Prep Kit is a fully customizable, amplicon-based assay for targeted resequencing starting from as low as 10 ng of genomic DNA (gDNA). This scalable assay allows researchers to capture multiple targets of interest simultaneously and sequence up to 1536 amplicons in a single pool, using a single reaction. This library prep kit offers the flexibility to accommodate FFPE samples, such as preserved tumor tissue.
Confident Assay Design
Design targeted TruSeq Custom Amplicon oligonucleotide probes with DesignStudio, a free, easy-to-use online tool that provides optimized coverage.
Learn more about DesignStudio
Start a project in DesignStudio now (login required)
Assess FFPE Sample Quality before Sequencing
The TruSeq FFPE DNA Library Prep QC Kit uses a simple qPCR reaction to determine DNA quality and provide guidance on sequencing parameters. This step ensures that only samples that will achieve the necessary sequencing metrics are prepared, conserving resources that might be used on potentially low-quality, unrecoverable samples. The results of the QC step determine the recommended amount of input DNA. The TruSeq FFPE DNA Library Prep QC Kit can be bundled with the TruSeq Custom Amplicon Low Input Library Prep Kit to maximize lab budgets.
For FFPE applications, we suggest designing your project with 150 bp or 175 bp amplicons since FFPE DNA is highly degraded. TruSeq Custom Amplicon Low Input cannot be used with applications requiring 425 bp amplicons.
Species Compatibility
The TruSeq Custom Amplicon Low Input Library Prep Kit supports human, mouse, rat, and bovine samples. DesignStudio design algorithms are also available for maize, rice, pig, dog, soybean, chicken, and sheep; however, assay performance cannot be guaranteed as the resulting assays have not been tested. In addition, Illumina Concierge services can design custom assays and/or provide assay optimization support for any species of interest.
Inquire about Illumina Concierge services
Find an up-to-date list of high-throughput automation vendors with robotic systems compatIBLe with this library preparation kit
Specifications:
Assay Time 1 day
Hands-On Time 4 hours
Input Quantity 50 ng RNA,50 ng high-quality total RNA,≥ 200 ng FFPE total RNA; Recommended quantity may vary with expression level, target plexity, and sample quality
Content Specifications Choose from 400,000+ pre-designed targeted RNA-Seq assays. Or add content to a fixed panel or previously designed custom panel.
Multiplexing Up to 384 samples per sequencing run
Mechanism of Action Amplification
TruSeq Custom Amplicon Library Prep Protocol:
The TruSeq Custom Amplicon assay is a simple and streamlined method for capturing and amplifying targeted regions of interest.
Seamless Amplicon Sequencing Workflow:
The TruSeq Custom Amplicon Low Input Library Prep Kit is part of an integrated, fully supported workflow for amplicon sequencing that guides researchers from design through data analysis. Illumina technical and field specialists help ensure rapid resolution and minimize potential laboratory downtime.
Robust Variant Detection at Low DNA Input:
The TruSeq Custom Amplicon Low Input Library Prep Kit demonstrates high concordance between expected and observed variant frequencies for 10 ng high-quality FFPE DNA. Reference DNA samples were prepared following the TruSeq Custom Amplicon Low Input workflow with the TruSeq Amplicon - Cancer Panel primer pool, and sequenced on the MiSeq System in replicates of 4. Variants were called using MiSeq Reporter Software. R2 values are shown."
"Illumina/TruSeq ChIP Library Preparation Kit - Set A (12 indexes, 48 rxns)/IP-202-1012/1 Ea
" Illumina 產(chǎn)品編號: IP-202-1012美 元 價: $2783.00會 員 價: 待定品 牌: Illumina產(chǎn) 地: 美國公 司: Illumina, Inc.產(chǎn)品分類: 分子類>二代測序>DNA文庫制備試劑盒公司分類: Library Preparation Kits "Product Highlights:
TruSeq ChIP Libary Preparation Kits provide a simple, cost-effective solution for generating chromatin immunoprecipitation sequencing (ChIP-Seq) libraries from ChIP-derived DNA. ChIP-Seq leverages next-generation sequencing (NGS) to quickly and efficiently determine the distribution and abundance of DNA-bound protein targets of interest across the genome.
This method has become one of the most widely used NGS applications, enabling researchers to reliably and simultaneously identify binding sites of a broad range of targets across the entire genome, with high resolution and without constraints.
TruSeq ChIP Library Preparation Kits are compatIBLe with all Illumina sequencers. Offering the proven data quality and ease of use of TruSeq DNA sequencing, they provide a streamlined ChIP-Seq library preparation workflow that leverages reagent master mixes to minimize pipetting and reduce total assay time.
The kits have a low DNA input requirement and are compatIBLe with a range of sample sources. In addition, they offer more robust multiplex sequencing with 24 unique indexes, allowing researchers to optimize the distribution of sequencing output across samples based on read depth requirements.
Specifications:
Assay Time ~6.5 hours
Hands-On Time ~3.5 hours
Input Quantity 10 ng high-quality genomic DNA; 10 – 100 ng FFPE DNA (depending on QC results)
Mechanism of Action Probe hybridization, extension-ligation, and PCR
Multiplexing 1–96
Content Specifications Design custom probes to sequence genomic regions of interest. Content range: 4 – 650 kb"
"Illumina/20-pack MiSeq Reagent Kit v2 (500-cycles)/MS-102-2023/1 Ea
" Illumina 產(chǎn)品編號: MS-102-2023美 元 價: $22000.00會 員 價: 待定品 牌: Illumina產(chǎn) 地: 美國公 司: Illumina, Inc.產(chǎn)品分類: 分子類>二代測序>簇生成和測序試劑公司分類: Cluster Generation & Sequencing Reagents "Product Highlights:
MiSeq Reagent Kits v2 enable more output to simplify each MiSeq run. MiSeq Reagent Kits v2 retain the same pre-filled, ready-to-use reagent cartridges as the v1 kits, but offer improved chemistry to increase cluster density, decrease cycle time, and improve quality (Q) scores. MiSeq Reagent Kits v2 are also available in micro and nano formats for low output applications.
Get faster cycle times, longer reads and more output from improved chemistry
Dual surface imaging enables twice the number of reads compared to single surface imaging with the v1 kit
Extend your read lengths with the 500-cycle kit
Choose the perfect number of cycles for your application (50, 300, or 500)
When coupled with the MiSeq System upgrade, the MiSeq Reagent Kits v2 allow dual surface imaging to double the amount of readable space per flow cell. MiSeq Regent Kits v2 are available in a 500-cycle format for long read lengths, as well as in the popular 50-cycle and 300-cycle formats.
MiSeq Reagent Kits v2 are available in standard, micro, and nano configurations, enabling alignment to specific project requirements and scalable levels of output.
View product configurations
All MiSeq reagent components are RFID-encoded and interact intelligently with the MiSeq System to validate compatibility with user-defined applications.
A MiSeq Reagent Kit v3 is also available. It offers a 600-cycle format to allow the longest read lengths on any Illumina sequencing system, or a 150-cycle format that enables counting applications.
Specifications:
Maximum Output 8.5 Gb (500-cycle MiSeq Reagent Kit v2), 5.1 Gb (300-cycle MiSeq Reagent Kit v2), 1.2 Gb (300-cycle MiSeq Reagent Micro Kit v2), 0.850 Gb (50-cycle MiSeq Reagent Kit v2), 0.5 Gb (500-cycle MiSeq Reagent Nano Kit v2), 0.3 Gb (300-cycle MiSeq Reagent Nano Kit v2)
Maximum Reads per Run Up to 15 million
Reagent Type Paired-End Sequencing,Cluster Generation,Sequencing by Synthesis
System Compatibility MiSeq,MiSeqDx in Research Mode,MiSeq FGx in Research Mode
Technology Sequencing"
"Illumina/TruSeq® Exome Kit (8 rxn × 12plex)/FC-150-1004/1 Ea
" Illumina 產(chǎn)品編號: FC-150-1004美 元 價: $6720.00會 員 價: 待定品 牌: Illumina產(chǎn) 地: 美國公 司: Illumina, Inc.產(chǎn)品分類: 分子類>二代測序>DNA文庫制備試劑盒公司分類: Library Preparation Kits "Product Highlights:
TruSeq Exome Library Prep Kit is a cost-effective library preparation and exome enrichment solution with industry-leADIng accuracy. It offers:
Pre-enrichment library pooling and optimal coverage for low-cost exome sequencing
Mechanical shearing and TruSeq enrichment technology that yield uniform coverage and greater than or equal to 80% on-target sequencing reads
Fully supported workflow solution to simplify exome sequencing
Cost-Effective Exome Sequencing
The TruSeq Exome Library Prep Kit supports 12-plex pre-enrichment library pooling, enabling researchers to maximize sequencing throughput and identify variants in less time by sequencing up to 12 libraries per flow cell lane. The high on-target percentage requires fewer sequencing cycles to reach the optimal level of coverage, while still achieving high coverage uniformity for confident results. It also enables sequencing of more exomes per run, so researchers can maximize their budgets.
To learn more about calculating coverage estimates, see the sequencing coverage calculator.
Proven TruSeq Data Quality
The TruSeq Exome Library Prep Kit delivers ≥ 80% of on-target sequencing reads for efficient, cost-effective exome sequencing. By combining the TruSeq Exome Library Prep Kit with Illumina systems using sequencing by synthesis (SBS) technology, researchers can identify true coding variants and minimize false-positive and false-negative calls.
Convenient, Integrated Workflow Solution
Illumina provides an integrated, fully supported workflow solution that guides researchers from library preparation through analysis. All components of the exome sequencing workflow are designed, optimized, and analytically validated together. Expert Illumina scientists provide a single source of technical and field support for every step in the process.
Find an up-to-date list of high-throughput automation vendors with robotic systems compatIBLe with this library preparation kit
Specifications:
Assay Time 2.5 days
Hands-On Time 6 hours
Input Quantity 100 ng genomic DNA
Content Specifications Captures coding exons. Covers 45 Mb of exonic content (≥98% of RefSeq, CCDS, and Ensembl coding content).
Mechanism of Action Mechanical fragmentation (COVARIS) and exome enrichment with biotinylated capture probes
Multiplexing Up to 12-plex enrichment
System Compatibility NovaSeq 5000,NextSeq 550,HiSeq 3000,NextSeq 500,NovaSeq 6000,HiSeq 4000
Specialized Sample Types FFPE
Technology Sequencing
Species Category Human
Automation CapABIlity Liquid Handling Robots
Method Exome Sequencing"
"Illumina/Nextera® XT Index Kit (96 indexes, 384 samples)/FC-131-1002/1 Ea
" Illumina 產(chǎn)品編號: FC-131-1002美 元 價: $999.00會 員 價: 待定品 牌: Illumina產(chǎn) 地: 美國公 司: Illumina, Inc.產(chǎn)品分類: 分子類>二代測序>DNA文庫制備試劑盒公司分類: Library Preparation Kits "Product Highlights:
Fast Library Prep, Optimized for Small Genomes, PCR Amplicons, and Plasmids
Rapid library preparation – complete library prep in as little as 90 minutes with only 15 minutes of hands-on time
Fast time to results – go from DNA to data in 8 hours with our benchtop sequencers.
Optimized for small genomes, PCR amplicons, and plasmids – one library prep kit for many applications
Innovative sample normalization – eliminates the need for library quantification before sample pooling and sequencing
With Nextera technology, DNA is simultaneously fragmented and tagged with sequencing adapters in a single tube enzymatic reaction. Nextera XT supports ultra-low DNA input of only 1 ng. It enables a wide range of input samples, including small genomes, PCR amplicons greater than 300 bp, plasmids, microbial genomes, concatenated amplicons, and double-stranded CDNA.
Multiplexing of up to 384 samples per Nextera XT library is also available for those projects requiring greater throughput. Plus, the kit includes an innovative bead-based sample normalization that eliminates the need for library quantification prior to pooling and sequencing. Libraries prepared with Nextera XT kits are compatIBLe with all Illumina sequencers.
Find an up-to-date list of high-throughput automation vendors with robotic systems compatIBLe with this library preparation kit
Specifications:
Assay Time 90 minutes
Hands-On Time 15 minutes
Mechanism of Action Enzymatic Fragmentation
Multiplexing Up to 384 uniquely indexed samples may be pooled and sequenced together.
Input Quantity 1 ng DNA
Species Category Drosophila,Any Species,Mammalian,Mouse,Yeast,Zebrafish,Human,Rat,Plant,Nematode,Bacteria
System Compatibility MiSeq,NextSeq 550,NextSeq 500,MiSeq FGx in Research Mode
Method Shotgun Sequencing,Whole-Genome Sequencing,De Novo Sequencing,16S rRNA Sequencing,Amplicon Sequencing,Targeted DNA Sequencing
Variant Class Single Nucleotide Polymorphisms (SNPs),Structural Variants
Specialized Sample Types Low Input,Single Cells
Technology Sequencing
Automation CapABIlity Liquid Handling Robots"
"Illumina/Nextera DNA CD Indexes (24 Indexes, 24 Samples)/20018707/1 Ea
" Illumina 產(chǎn)品編號: 20018707美 元 價: $120.00會 員 價: 待定品 牌: Illumina產(chǎn) 地: 美國公 司: Illumina, Inc.產(chǎn)品分類: 分子類>二代測序>DNA文庫制備試劑盒公司分類: Library Preparation Kits "Product Highlights:
The Nextera DNA Flex Library Prep Kit offers flexibility for many whole-genome sequencing applications.
Fastest Illumina library prep workflow, with ~3.5 hours total time
Flexibility to accommodate variations in sample type, DNA input amount, and application
Optimized library prep performance, generating reliable results
Save Time and Resources
The Nextera DNA Flex Library Prep Kit uses a fast, user-friendly workflow. On-bead tagmentation chemistry reduces total library prep time to ~3.5 hours, from DNA extraction to library normalization.
Simplify Lab Operations
The Nextera DNA Flex workflow supports a broad DNA input range (1–500 ng), multiple sample types, and both small and large genomes. The workflow includes DNA extraction from blood, saliva, or dried blood spots*or bacterial colonies*. Gain the flexibility to sequence human or other large, complex genomes as well as amplicons or microbial species, all with a single kit.
Obtain Reliable Results
While accommodating various study requirements, the Nextera DNA Flex workflow delivers consistent insert sizes, uniform coverage, and optimized performance, regardless of DNA input amount or genome size. The bead-based technology minimizes bias and opportunities for error, resulting in highly reproducIBLe sequencing data.
*Demonstrated protocols available.
Specifications:
Assay Time ~3.5 hours total assay time
Hands-On Time 1-1.5 hours
Input Quantity Small Genomes: 1-500 ng DNA; Large Genomes: 100-500 ng
Content Specifications Human Whole Genome, Small Whole Genome, Large Whole Genome
Mechanism of Action Bead-linked transposome
Multiplexing Up to 96 available indexes
Species Category Any Species
System Compatibility MiSeq,HiSeq X Ten,NextSeq 550,HiSeq 3000,HiSeq X Five,MiSeqDx in Research Mode,MiniSeq,HiSeq 2500,NovaSeq 6000,HiSeq 4000
Variant Class Single Nucleotide Polymorphisms (SNPs),Gene Fusions,Loss of Heterozygosity (LOH),Somatic Variants,Chromosomal Abnormalities,Germline Variants,Structural Variants,Insertions-Deletions (indels),Copy Number Variants (CNVs)
Method Whole-Genome Sequencing
Technology Sequencing
Automation CapABIlity Liquid Handling Robots"
"Illumina/TruSeq Dual Index Sequencing Primer Box, Single-Read/FC-121-1003/1 Ea
" Illumina 產(chǎn)品編號: FC-121-1003美 元 價: $95.00會 員 價: 待定品 牌: Illumina產(chǎn) 地: 美國公 司: Illumina, Inc.產(chǎn)品分類: 分子類>二代測序>簇生成和測序試劑公司分類: Cluster Generation & Sequencing Reagents "Product Highlights:
The primers provided in the TruSeq Dual Index Sequencing Primer Box are required for sequencing the following libraries on the HiSeq 2500, HiSeq 2000, HiSeq 1500, HiSeq 1000 Systems; the HiScanSQ System using TruSeq SBS Kit v3; or the Genome Analyzer System.
The single-read kit should be used with a single-read flow cell, and the paired-end kit with a paired-end flow cell.
Any Nextera library except Nextera Mate Pair
Any library constructed with a Nextera or Nextera XT Index Kit
Any TruSeq HT library when performing a dual-index run on a single-read flow cell
A TruSeq Synthetic Long-Read DNA library
Any TruSight library except TruSight RNA Pan-Cancer
A TruSeq Rapid Exome library
A TruSeq Custom Amplicon library (v1.5 and Low Input)
A TruSeq Amplicon Cancer Panel library
A VeriSeq PGS library"
"Illumina/MiniSeq Mid Output Kit (300-cycles)/FC-420-1004/1 Ea
" Illumina 產(chǎn)品編號: FC-420-1004美 元 價: $550.00會 員 價: 待定品 牌: Illumina產(chǎn) 地: 美國公 司: Illumina, Inc.產(chǎn)品分類: 分子類>二代測序>簇生成和測序試劑公司分類: Cluster Generation & Sequencing Reagents "Product Highlights:
MiniSeq System sequencing reagent kits bring the power and reliABIlity of proven Illumina next-generation sequencing (NGS) to labs of all sizes. Access cost-efficient sequencing with high data quality, even for low numbers of samples. These kits offer:
Robust base calling and optimal signal-to-noise ratio
Multiple options for both sequencing output and read length
Simple workflow that reduces chance for error through the integration of clustering, sequencing and wash reagents into a single cartridge
Intuitive labeling and RFID-encoded reagents
Optimized chemistry with the latest in Illumina sequencing by synthesis (SBS) chemistry
Configurations for various applications
MiniSeq Reagent Kits offer a wide range of solutions for applications ranging from gene expression and small RNA profiling to targeted DNA amplicon sequencing and small genome sequencing. High accuracy and paired-end sequencing capABIlity are built into every reagent kit.
Ready-to-use cartridges redefine ease of use
Preconfigured reagent kits for the MiniSeq System provide all the components needed for cluster generation, sequencing and wash on the platform in 1 premixed, integrated, RFID-enabled cartridge. Simply load user-prepared library pools directly into the MiniSeq System. The system automatically performs all steps necessary for template amplification and sequencing without user intervention.
The kits deliver powerful sequencing chemistries with as little as 10 minutes of hands-on time. Intuitive labeling and RFID-encoded reagents ensure compatibility with user-defined run configurations.
Specifications:
Maximum Output 7.5 Gb (300-cycle high output kit), 3.75 Gb (150-cycle high output kit), 2.4 Gb (300-cycle mid output kit), 1.875 Gb (75-cycle high output kit)
Maximum Reads Per Run Up to 25 million (high output kits), Up to 8 million (mid output kits)
Reagent Type Paired-End Sequencing,Cluster Generation,Sequencing by Synthesis
Technology Sequencing
System Compatibility MiniSeq"
"Illumina/TruSeq Stranded Total RNA Library Prep Kit with Ribo-Zero Gold High Throughput (96 samples, 96 indexes)/RS-122-
" Illumina 產(chǎn)品編號: RS-122-2303美 元 價: $10280.00會 員 價: 待定品 牌: Illumina產(chǎn) 地: 美國公 司: Illumina, Inc.產(chǎn)品分類: 分子類>二代測序>DNA文庫制備試劑盒公司分類: Library Preparation Kits "Product Highlights:
The TruSeq Stranded Total Library Preparation kit provides a clear view of the transcriptome with a streamlined, cost-efficient, and scalable solution for total RNA analysis with sequencing.
Whole-Transcriptome Analysis with Precise Measurement of Strand Orientation
CompatIBLe with a wide range of samples, including low-quality and FFPE, TruSeq Stranded Total RNA kits couple all of the benefits of TruSeq RNA preparation kits with Ribo-Zero ribosomal RNA reduction chemistry, providing analysis of coding and multiple forms of noncoding RNA with precise measurement of strand orientation, uniform coverage, and high-confidence discovery of features such as alternative transcripts, gene fusions, and allele-specific expression.
Find an up-to-date list of high-throughput automation vendors with robotic systems compatIBLe with this library preparation kit
FlexIBLe Solutions for a Range of Study Designs
The TruSeq Stranded Total RNA Library Prep kit is available in multiple versions to fit specific study design needs:
TruSeq Stranded Total RNA with Ribo-Zero Human/Mouse/Rat removes cytoplasmic rRNA.
TruSeq Stranded Total RNA with Ribo-Zero Gold removes both cytoplasmic and mitochondrial rRNA.
The total RNA kits are also compatIBLe with the new unique dual index kits, TruSeq RNA Unique Dual Indexes, which allows multiplexing of up to 96 samples.
Species Compatibility
The TruSeq Stranded Total Library Preparation kit is designed for human, mouse and rat sequences, but may be applicable to a variety of eukaryotic species.*
*For information on a particular species of interest, contact Illumina Technical Support.
Specifications:
Input Quantity 0.1 – 1 ug high-quality total RNA. Lower-quality samples may require further optimization.
Content Specifications Captures coding RNA plus multiple forms of non-coding RNA
Mechanism of Action Bead-based rRNA depletion, CDNA synthesis, and PCR
Multiplexing Low-throughput kits: Pool up to 12 samples. Or pool up to 24 samples with sets A and B together,High-throughput kits: Prepare 96 uniquely indexed samples.
System Compatibility NovaSeq 5000,Genome Analyzer IIx,HiSeq 2000,NextSeq 550,HiSeq 3000,HiSeq 1000,HiSeq 1500,NextSeq 500,HiSeq 2500,NovaSeq 6000,HiSeq 4000
Variant Class Single Nucleotide Polymorphisms (SNPs),Gene Fusions,Novel Transcripts,Transcript Variants
Specialized Sample Types FFPE
Method Whole-Transcriptome Sequencing
Species Category Mouse,Human,Rat
Technology Sequencing
Automation CapABIlity Liquid Handling Robots"
"Illumina/TruSeq Nano DNA LT Library Preparation Kit - Set A (12 Set A index tubes, 24 samples)/FC-121-4001/1 Ea
" Illumina 產(chǎn)品編號: FC-121-4001美 元 價: $735.00會 員 價: 待定品 牌: Illumina產(chǎn) 地: 美國公 司: Illumina, Inc.產(chǎn)品分類: 分子類>二代測序>DNA文庫制備試劑盒公司分類: Library Preparation Kits "Product Highlights:
The TruSeq Nano DNA Library Preparation Kit enables efficient interrogation of samples with limited available DNA. Based on the industry’s most widely adopted library preparation workflow, this low-input method delivers high coverage quality and reduced bias for virtually any sequencing application.
Designed for low sample input
High coverage quality
Accelerated library preparation
Manual preparation of high-quality libraries in less than a day
The proven TruSeq DNA library preparation workflow has been streamlined by replacing gel-based size selection with bead-based selection, enabling researchers to prepare high-quality libraries in less than a day. It is optimized for a variety of read lengths, from 2 × 101 bp to 2 × 151 bp.
Use with limited DNA samples
The TruSeq Nano DNA protocol offers excellent results with as little as 100 ng input, eliminating the typical requirement for micrograms of DNA. This enables researchers to study samples with limited available DNA (eg, tumor samples) and helps preserve samples for use in future or alternate studies. In addition to accelerating the workflow, bead-based size selection avoids typical sample loss associated with gel-based selection.
Reduce library bias and coverage gaps
TruSeq Nano DNA kits reduce the number and average size of typical PCR-induced gaps in coverage. The enhanced workflow reduces library bias and improves coverage uniformity across the genome. These kits also provide excellent coverage of trADItionally challenging genomic content, including GC-rich regions, promoters, and repetitive regions. This enables researchers to access more information from each sequencing run. TruSeq Nano DNA kits are validated for high-quality genomic coverage for virtually any next-generation sequencing application.
Access flexIBLe throughput options
Kits include reagents, sample purification beads, and indexes, with two options for flexibility:
TruSeq Nano DNA LT Library Preparation Kits support 24-plex manual processing for low-throughput studies.
TruSeq Nano DNA HT Library Preparation Kits are 96-plex for high-throughput studies, and can be automated on liquid handling robots (or processed manually).
TruSeq Nano DNA Library Preparation Kits are also available for use with the automated NeoPrep Library Prep System.
Find an up-to-date list of automation vendors with robotic systems that support the HT library preparation kits
Specifications:
Assay Time 1 day
Hands-On Time 4 hours
Input Quantity 50 ng RNA,50 ng high-quality total RNA,≥ 200 ng FFPE total RNA; Recommended quantity may vary with expression level, target plexity, and sample quality
Content Specifications Choose from 400,000+ pre-designed targeted RNA-Seq assays. Or add content to a fixed panel or previously designed custom panel.
Multiplexing Up to 384 samples per sequencing run
Mechanism of Action Amplification
Method Shotgun Sequencing,Whole-Genome Sequencing,Genotyping by Sequencing
Variant Class Single Nucleotide Polymorphisms (SNPs),Gene Fusions,Loss of Heterozygosity (LOH),Somatic Variants,Chromosomal Abnormalities,Germline Variants,Structural Variants,Insertions-Deletions (indels),Copy Number Variants (CNVs)
Species Category Mammalian,Mouse,Human,Other,Rat,Plant
System Compatibility NextSeq 550,HiSeq 3000,HiSeq X Five,HiSeq 1000,MiSeqDx in Research Mode,MiniSeq,HiSeq 2000,MiSeq,HiSeq X Ten,NeoPrep,HiSeq 1500,NextSeq 500,HiSeq 2500,HiSeq 4000
Specialized Sample Types Low Input
Technology Sequencing
Automation CapABIlity NeoPrep Digital Microfluidics,Liquid Handling Robots"
"Illumina/ForenSeq DNA Signature Prep Kit/TG-450-1001/1 Ea
" Illumina 產(chǎn)品編號: TG-450-1001美 元 價: $15500.00會 員 價: 待定品 牌: Illumina產(chǎn) 地: 美國公 司: Illumina, Inc.產(chǎn)品分類: 分子類>二代測序>DNA文庫制備試劑盒公司分類: Library Preparation Kits "Product Highlights:
The ForenSeq DNA Signature Prep Kit is part of a complete, fully validated DNA-to-data solution designed for forensic genomics applications. It includes all reagents to prepare next-generation sequencing (NGS) libraries from forensic DNA samples.
Achieve high resolution and exceptional accuracy from as little as 1 ng of DNA—Even with complex mixtures or degraded DNA. This kit allows labs to:
Perform multiplexing and rapid sample processing
Access a wider range of informative single-nucleotide polymorphisms (SNPs) with a single kit
Analyze challenging samples
Multiplexing and rapid sample processing
The ForenSeq DNA Signature Prep Kit supports preparation of up to 96 libraries simultaneously using a simple plate-based format and standard lab equipment. Targeted primer mixes enable analysis of autosomal, Y- and X-chromosome short tandem repeat (STR) targets, and identity-informative SNPs, all in a single reaction.
Optionally, you can include biogeographical ancestry-informative SNPs (aiSNPs) and phenotypic-informative SNPs (piSNPs). This data can be critical in generating investigative leads from “no sUSPect” cases that have otherwise gone cold.
A wider range of informative SNPs with a single kit
The ForenSeq DNA Signature Prep Kit consolidates all autosomal STR Markers currently used around the world for casework and criminal DNA databases. This single, streamlined workflow eliminates the need to run multiple STR tests.
The kit delivers approximately 200 genetic Markers in a single test, removing the tradeoffs and risk imposed by technical limitations such as low DNA quantity. It also contains a dense set of identity informative single nucleotide polymorphism (iiSNP) Marker sets not routinely available with trADItional capillary electrophoresis (CE) methods.
Superior analysis of challenging samples
Cases are often complicated and sometimes unresolved due to the presence of highly degraded DNA, low quality DNA, or complex DNA mixtures. The ForenSeq DNA Signature Prep Kit includes a large number of Markers, many of which are highly polymorphic.
These additional Markers, coupled with the inherent sensitivity of Illumina chemistry, help detect minor components that might go undetected by conventional STR and CE analysis.
Specifications:
Assay Time ~6.5 hours
Hands-On Time ~3.5 hours
Input Quantity 10 ng high-quality genomic DNA; 10 – 100 ng FFPE DNA (depending on QC results)
Mechanism of Action Probe hybridization, extension-ligation, and PCR
Multiplexing 1–96
Content Specifications Design custom probes to sequence genomic regions of interest. Content range: 4 – 650 kb
System Compatibility NovaSeq 5000,HiSeq 2000,HiScanSQ,MiSeq FGx
Variant Class Single Nucleotide Polymorphisms (SNPs),Gene Fusions,Short Tandem Repeats (STRs)
Specialized Sample Types Low Input
Technology Sequencing
Species Category Human
Method Amplicon Sequencing,Targeted DNA Sequencing
ForenSeq DNA Signature Prep Kit Workflow:
The ForenSeq DNA Signature Prep Kit is part of a fully integrated, sample-to-answer solution, including library preparation, DNA sequencing platform, and data analysis software specifically designed for forensic genomics.
ForenSeq DNA Signature Prep Kit Forensic Loci and Investigative Workflow:
With ~200 genetic Markers in a single workflow, the MiSeq FGx System offers the most comprehensive multiplex of STRs and SNPs and the most straightforward path to human identification."
"Illumina/TruSeq Synthetic Long-Read DNA Barcode Kit (4 barcode plates)/FC-126-1003/1 Ea
" Illumina 產(chǎn)品編號: FC-126-1003美 元 價: $3045.00會 員 價: 待定品 牌: Illumina產(chǎn) 地: 美國公 司: Illumina, Inc.產(chǎn)品分類: 分子類>二代測序>DNA文庫制備試劑盒公司分類: Library Preparation Kits "Product Highlights:
The TruSeq Synthetic Long-Read DNA Library Prep Kit is a highly accurate, end-to-end sequencing solution that can be used for genome assembly or genome phasing. Depending on the analysis option you select, you can use it to:
Assemble synthetically long reads for de novo assembly and genome finishing applications
Perform genome phasing to identify co-inherited alleles and haplotype information, as well as phase de novo mutations
Accurately Construct Synthetic Long Reads
The TruSeq Synthetic Long-Read DNA Library Prep and TruSeq Synthetic Long-Read DNA Barcode Kits are designed for preparing DNA libraries to generate synthetically long reads. The library prep kit combines TruSeq and Nextera chemistries with synthetic long-read technology to prepare DNA libraries. The accompanying barcode kit includes 384 indexes for labeling the samples in each well. These indexes are then used after sequencing to construct synthetically long fragments for long-read assembly and phasing analysis.
Simplified Informatics for Genome Assembly or Human Whole-Genome Phasing
After sequencing, push-button analysis in BaseSpace Sequence Hub simplifies assembly of long reads. Data can be transferred from an Illumina sequencing instrument to the BaseSpace Sequence Hub cloud instantly.
BaseSpace App for Genome Assembly:
The TruSeq Long-Read Assembly App constructs long, synthetic reads from shorter sequencing reads for accurate genome assembly and genome finishing. TruSeq synthetic long-read technology allows you to use the same familiar platform with a new application.
BaseSpace App for Phasing Analysis:
The TruSeq Phasing Analysis App can be used to perform whole human genome phasing, identifying haplotype information and co-inherited alleles, and phasing de novo mutations. By constructing synthetically long fragments from shorter sequencing reads, this method provides more comprehensive and accurate phasing compared to conventional trio studies or statistical inference.
Specifications:
Assay Time 3 days
Hands-On Time 6 hours
Species Category Any Species
System Compatibility HiSeq 2000,HiSeq 3000,HiSeq 2500,HiSeq 4000
Method Whole-Genome Sequencing,De Novo Sequencing,Long-Read Sequencing
Technology Sequencing
品牌介紹
"
"Illumina/TruSeq® Rapid Exome Kit (8 rxn × 12 plex)/FC-144-1004/1 Ea
" Illumina 產(chǎn)品編號: FC-144-1004美 元 價: $9600.00會 員 價: 待定品 牌: Illumina產(chǎn) 地: 美國公 司: Illumina, Inc.產(chǎn)品分類: 分子類>二代測序>DNA文庫制備試劑盒公司分類: Library Preparation Kits "Product Highlights:
The TruSeq Rapid Exome Library Prep Kit delivers a simple, efficient method for high-confidence calling of exonic variants. The fast library preparation and exome enrichment workflow deliver libraries in 1 day with no need for additional equipment, giving labs the flexibility to plan projects according to sample volume. This kit offers:
Enhanced transposome chemistry results in reduced bias, providing consistent library preparation and exome enrichment.
Rapid, automation-friendly workflow completes in 1 day with only 3 hours of hands-on time.
High coverage uniformity across exonic regions and on-target %
Proven TruSeq Data Quality
The TruSeq Rapid Exome Library Prep Kit delivers an average of 75% of on-target sequencing reads. This high on-target percentage requires fewer sequencing cycles to reach desired coverage levels, but still achieves uniform coverage for high-confidence results.
To learn more about calculating coverage estimates, see the sequencing coverage calculator.
Find an up-to-date list of high-throughput automation vendors with robotic systems compatIBLe with this library preparation kit
Specifications:
Assay Time 1 day
Hands-On Time 3 hours
Input Quantity 50 ng genomic DNA
Content Specifications Captures coding exons. Covers 45 Mb of exonic content (≥98% of RefSeq, CCDS, and Ensembl coding content).
Mechanism of Action Transposase-based fragmentation and exome enrichment with biotinylated capture probes
Multiplexing Up to 12-plex enrichment
Technology Sequencing
Species Category Human
Automation CapABIlity Liquid Handling Robots
System Compatibility NextSeq 500,NovaSeq 6000,HiSeq 4000
Method Exome Sequencing
"
"Illumina/Flex Lysis Reagent Kit/20018706/1 Ea
" Illumina 產(chǎn)品編號: 20018706美 元 價: $288.00會 員 價: 待定品 牌: Illumina產(chǎn) 地: 美國公 司: Illumina, Inc.產(chǎn)品分類: 分子類>二代測序>DNA文庫制備試劑盒公司分類: Library Preparation Kits "Product Highlights:
The Nextera DNA Flex Library Prep Kit offers flexibility for many whole-genome sequencing applications.
Fastest Illumina library prep workflow, with ~3.5 hours total time
Flexibility to accommodate variations in sample type, DNA input amount, and application
Optimized library prep performance, generating reliable results
Save Time and Resources
The Nextera DNA Flex Library Prep Kit uses a fast, user-friendly workflow. On-bead tagmentation chemistry reduces total library prep time to ~3.5 hours, from DNA extraction to library normalization.
Simplify Lab Operations
The Nextera DNA Flex workflow supports a broad DNA input range (1–500 ng), multiple sample types, and both small and large genomes. The workflow includes DNA extraction from blood, saliva, or dried blood spots*or bacterial colonies*. Gain the flexibility to sequence human or other large, complex genomes as well as amplicons or microbial species, all with a single kit.
Obtain Reliable Results
While accommodating various study requirements, the Nextera DNA Flex workflow delivers consistent insert sizes, uniform coverage, and optimized performance, regardless of DNA input amount or genome size. The bead-based technology minimizes bias and opportunities for error, resulting in highly reproducIBLe sequencing data.
*Demonstrated protocols available.
Specifications:
Assay Time ~3.5 hours total assay time
Hands-On Time 1-1.5 hours
Input Quantity Small Genomes: 1-500 ng DNA; Large Genomes: 100-500 ng
Content Specifications Human Whole Genome, Small Whole Genome, Large Whole Genome
Mechanism of Action Bead-linked transposome
Multiplexing Up to 96 available indexes
Species Category Any Species
System Compatibility MiSeq,HiSeq X Ten,NextSeq 550,HiSeq 3000,HiSeq X Five,MiSeqDx in Research Mode,MiniSeq,HiSeq 2500,NovaSeq 6000,HiSeq 4000
Variant Class Single Nucleotide Polymorphisms (SNPs),Gene Fusions,Loss of Heterozygosity (LOH),Somatic Variants,Chromosomal Abnormalities,Germline Variants,Structural Variants,Insertions-Deletions (indels),Copy Number Variants (CNVs)
Method Whole-Genome Sequencing
Technology Sequencing
Automation CapABIlity Liquid Handling Robots"
"Illumina/TruSeq Nano DNA HT Library Preparation Kit (96 indexes in plate format, 96 samples)/FC-121-4003/1 Ea
" Illumina 產(chǎn)品編號: FC-121-4003美 元 價: $3000.00會 員 價: 待定品 牌: Illumina產(chǎn) 地: 美國公 司: Illumina, Inc.產(chǎn)品分類: 分子類>二代測序>DNA文庫制備試劑盒公司分類: Library Preparation Kits "Product Highlights:
The TruSeq Nano DNA Library Preparation Kit enables efficient interrogation of samples with limited available DNA. Based on the industry’s most widely adopted library preparation workflow, this low-input method delivers high coverage quality and reduced bias for virtually any sequencing application.
Designed for low sample input
High coverage quality
Accelerated library preparation
Manual preparation of high-quality libraries in less than a day
The proven TruSeq DNA library preparation workflow has been streamlined by replacing gel-based size selection with bead-based selection, enabling researchers to prepare high-quality libraries in less than a day. It is optimized for a variety of read lengths, from 2 × 101 bp to 2 × 151 bp.
Use with limited DNA samples
The TruSeq Nano DNA protocol offers excellent results with as little as 100 ng input, eliminating the typical requirement for micrograms of DNA. This enables researchers to study samples with limited available DNA (eg, tumor samples) and helps preserve samples for use in future or alternate studies. In addition to accelerating the workflow, bead-based size selection avoids typical sample loss associated with gel-based selection.
Reduce library bias and coverage gaps
TruSeq Nano DNA kits reduce the number and average size of typical PCR-induced gaps in coverage. The enhanced workflow reduces library bias and improves coverage uniformity across the genome. These kits also provide excellent coverage of trADItionally challenging genomic content, including GC-rich regions, promoters, and repetitive regions. This enables researchers to access more information from each sequencing run. TruSeq Nano DNA kits are validated for high-quality genomic coverage for virtually any next-generation sequencing application.
Access flexIBLe throughput options
Kits include reagents, sample purification beads, and indexes, with two options for flexibility:
TruSeq Nano DNA LT Library Preparation Kits support 24-plex manual processing for low-throughput studies.
TruSeq Nano DNA HT Library Preparation Kits are 96-plex for high-throughput studies, and can be automated on liquid handling robots (or processed manually).
TruSeq Nano DNA Library Preparation Kits are also available for use with the automated NeoPrep Library Prep System.
Find an up-to-date list of automation vendors with robotic systems that support the HT library preparation kits
Specifications:
Assay Time 1 day
Hands-On Time 4 hours
Input Quantity 50 ng RNA,50 ng high-quality total RNA,≥ 200 ng FFPE total RNA; Recommended quantity may vary with expression level, target plexity, and sample quality
Content Specifications Choose from 400,000+ pre-designed targeted RNA-Seq assays. Or add content to a fixed panel or previously designed custom panel.
Multiplexing Up to 384 samples per sequencing run
Mechanism of Action Amplification
Method Shotgun Sequencing,Whole-Genome Sequencing,Genotyping by Sequencing
Variant Class Single Nucleotide Polymorphisms (SNPs),Gene Fusions,Loss of Heterozygosity (LOH),Somatic Variants,Chromosomal Abnormalities,Germline Variants,Structural Variants,Insertions-Deletions (indels),Copy Number Variants (CNVs)
Species Category Mammalian,Mouse,Human,Other,Rat,Plant
System Compatibility NextSeq 550,HiSeq 3000,HiSeq X Five,HiSeq 1000,MiSeqDx in Research Mode,MiniSeq,HiSeq 2000,MiSeq,HiSeq X Ten,NeoPrep,HiSeq 1500,NextSeq 500,HiSeq 2500,HiSeq 4000
Specialized Sample Types Low Input
Technology Sequencing
Automation CapABIlity NeoPrep Digital Microfluidics,Liquid Handling Robots"
"Illumina/TruSeq SBS Kit v3-HS (200 cycles)/FC-401-3001/1 Ea
" Illumina 產(chǎn)品編號: FC-401-3001美 元 價: $8600.00會 員 價: 待定品 牌: Illumina產(chǎn) 地: 美國公 司: Illumina, Inc.產(chǎn)品分類: 分子類>二代測序>簇生成和測序試劑公司分類: Cluster Generation & Sequencing Reagents "Product Highlights:
TruSeq SBS v3-HS kits contain ready-to-load reagents for accurately determining the DNA sequence of each cluster on a flow cell using sequencing by synthesis (SBS) technology on HiSeq sequencing systems. These kits offer a hands-on preparation time of only two minutes.
To perform a TruSeq v3 run on an enabled HiSeq system, you need one TruSeq SBS Kit v3. Each kit includes sufficient reagents for sequencing 1 flow cell.
The TruSeq v3 reagent kits can be run using either single-read (SR) or paired-end (PE) reads.
The TruSeq PE Cluster Kit v3-cBot-HS enables up to 600 Gb of output, while the TruSeq SR Cluster Kit v3-cBot-HS enables up to 300 Gb of output.
Note: This kit is NOT compatIBLe with the Genome Analyzer.
Specifications:
Maximum Output Up to 600 Gb (with HiSeq 2500 dual flow cell)
Maximum Reads per Run Up to 6 billion paired-end reads (with HiSeq 2500 dual flow cell)
Reagent Type Paired-End Sequencing,Sequencing by Synthesis,Single-Read Sequencing
System Compatibility HiSeq 2000,HiScanSQ,HiSeq 1000,HiSeq 2500
Technology Sequencing"
"Illumina/TruSeq Synthetic Long-Read DNA Accessory Kit/FC-126-1004/1 Ea
" Illumina 產(chǎn)品編號: FC-126-1004美 元 價: $81.00會 員 價: 待定品 牌: Illumina產(chǎn) 地: 美國公 司: Illumina, Inc.產(chǎn)品分類: 分子類>二代測序>DNA文庫制備試劑盒公司分類: Library Preparation Kits "Product Highlights:
The TruSeq Synthetic Long-Read DNA Library Prep Kit is a highly accurate, end-to-end sequencing solution that can be used for genome assembly or genome phasing. Depending on the analysis option you select, you can use it to:
Assemble synthetically long reads for de novo assembly and genome finishing applications
Perform genome phasing to identify co-inherited alleles and haplotype information, as well as phase de novo mutations
Accurately Construct Synthetic Long Reads
The TruSeq Synthetic Long-Read DNA Library Prep and TruSeq Synthetic Long-Read DNA Barcode Kits are designed for preparing DNA libraries to generate synthetically long reads. The library prep kit combines TruSeq and Nextera chemistries with synthetic long-read technology to prepare DNA libraries. The accompanying barcode kit includes 384 indexes for labeling the samples in each well. These indexes are then used after sequencing to construct synthetically long fragments for long-read assembly and phasing analysis.
Simplified Informatics for Genome Assembly or Human Whole-Genome Phasing
After sequencing, push-button analysis in BaseSpace Sequence Hub simplifies assembly of long reads. Data can be transferred from an Illumina sequencing instrument to the BaseSpace Sequence Hub cloud instantly.
BaseSpace App for Genome Assembly:
The TruSeq Long-Read Assembly App constructs long, synthetic reads from shorter sequencing reads for accurate genome assembly and genome finishing. TruSeq synthetic long-read technology allows you to use the same familiar platform with a new application.
BaseSpace App for Phasing Analysis:
The TruSeq Phasing Analysis App can be used to perform whole human genome phasing, identifying haplotype information and co-inherited alleles, and phasing de novo mutations. By constructing synthetically long fragments from shorter sequencing reads, this method provides more comprehensive and accurate phasing compared to conventional trio studies or statistical inference.
Specifications:
Assay Time 3 days
Hands-On Time 6 hours
Species Category Any Species
System Compatibility HiSeq 2000,HiSeq 3000,HiSeq 2500,HiSeq 4000
Method Whole-Genome Sequencing,De Novo Sequencing,Long-Read Sequencing
Technology Sequencing
品牌介紹
"
"Illumina/TruSeq DNA PCR-Free LT Library Preparation Kit - Set A (12 Set A index tubes, 24 samples)/FC-121-3001/1 Ea
" Illumina 產(chǎn)品編號: FC-121-3001美 元 價: $735.00會 員 價: 待定品 牌: Illumina產(chǎn) 地: 美國公 司: Illumina, Inc.產(chǎn)品分類: 分子類>二代測序>DNA文庫制備試劑盒公司分類: Library Preparation Kits "Product Highlights:
TruSeq DNA PCR-Free Library Preparation Kits provide simple, all-inclusive library preparation for whole-genome sequencing applications. Researchers can sequence a wide variety of organisms, from small genomes such as bacteria to human whole-genomes. The kits offer:
Shortened gel-free workflows that remove the need for PCR
ABIlity to sequence the most challenging regions
Improved genome coverage to identify the greatest number of variants
Sequence the most challenging regions
TruSeq DNA PCR-free kits offer superior coverage of areas which are trADItionally difficult to sequence such as high GC-rich regions, promoters, and repetitive content.
The kits are tunable to a variety of read lengths and are supported on all Illumina sequencing instruments. This permits the researcher to tailor each run to the needs of the experiment.
Detect the greatest number of variants
PCR-free means reduced library bias and gaps. The result is unsurpassed data quality. This enables you to detect the greatest number of variants. Excellent genome coverage means your results have the lowest and smallest number of gaps and enhanced coverage of high G/C rich regions.
Use PCR-free for faster protocols
Removing PCR creates a faster protocol and superior data quality. Bead-based size selection shortens the workflow. In tandem with Illumina sequencing systems, the TruSeq DNA PCR-Free Library Preparation Kit provides a range of enhancements to the industry's most widely adopted library preparation workflow.
Access flexIBLe throughput options
Kits include reagents, sample purification beads, and indexes, with two options for flexibility:
TruSeq DNA PCR-Free LT Library Preparation Kits support 24-plex manual processing for low-throughput studies.
TruSeq DNA PCR-Free HT Library Preparation Kits are 96-plex for high-throughput studies, and can be automated on liquid handling robots (or processed manually).
Find an up-to-date list of automation vendors with robotic systems that support the HT library preparation kits
Specifications:
Input Quantity 0.1 – 1 ug high-quality purified total RNA from blood
Content Specifications Captures coding RNA plus multiple forms of non-coding RNA
Mechanism of Action Bead-based rRNA depletion, CDNA synthesis, and PCR
Multiplexing Low-throughput kits: Pool up to 12 samples. Or pool up to 24 samples with sets A and B together,High-throughput kit version: Prepare 96 uniquely indexed samples
System Compatibility NovaSeq 5000,Genome Analyzer IIx,HiSeq 2000,NextSeq 500,HiSeq 2500,NextSeq 550,HiSeq 3000,HiSeq 1000
Automation CapABIlity Liquid Handling Robots
Variant Class Transcript Variants,Single Nucleotide Polymorphisms (SNPs),Gene Fusions
Species Category Rat,Mouse
Method Whole-Transcriptome Sequencing
Technology Sequencing"
"Illumina/TruSeq Stranded Total RNA Kit with Ribo-Zero Plant, Set B (48 samples, 12 indexes)/RS-122-2402/1 Ea
" Illumina 產(chǎn)品編號: RS-122-2402美 元 價: $5630.00會 員 價: 待定品 牌: Illumina產(chǎn) 地: 美國公 司: Illumina, Inc.產(chǎn)品分類: 分子類>二代測序>DNA文庫制備試劑盒公司分類: Library Preparation Kits "Product Highlights:
High-Quality Whole-Transcriptome Analysis with Precise Strand Information
RNA-Seq technology provides uniform coverage, precise measurement of strand orientation and high-confidence discovery of features such as alternative transcripts, antisense expression and allele-specific expression across both coding and multiple forms of noncoding RNA. The TruSeq Stranded Total RNA with Ribo-Zero Plant Kit couples the benefits of TruSeq RNA library preparation with Ribo-Zero ribosomal RNA reduction chemistry, providing a robust and scalable solution for whole-transcriptome analysis.
Find an up-to-date list of high-throughput automation vendors with robotic systems compatIBLe with this library preparation kit
Efficient Ribosomal RNA Reduction Across a Range of Plant Species, Study Designs
The TruSeq Stranded Total RNA with Ribo-Zero Plant Kit enables rapid and specific removal of cytoplasmic, mitochondrial and chloroplast ribosomal RNA from leaf, seed, and root tissue. The kit has been validated for use in multiple plant species, including ArABIdopsis thaliana, rice, and maize, and will provide efficient rRNA removal in a broad range of additional species.*
*For information on a particular species of interest, contact Illumina Technical Support.
Specifications:
Assay Time ~6.5 hours
Hands-On Time ~3.5 hours
Input Quantity 10 ng high-quality genomic DNA; 10 – 100 ng FFPE DNA (depending on QC results)
Mechanism of Action Probe hybridization, extension-ligation, and PCR
Multiplexing 1–96
Content Specifications Design custom probes to sequence genomic regions of interest. Content range: 4 – 650 kb
Variant Class Short Tandem Repeats (STRs),Single Nucleotide Polymorphisms (SNPs),Gene Fusions,Loss of Heterozygosity (LOH),Somatic Variants,Chromosomal Abnormalities,Germline Variants,Structural Variants,Insertions-Deletions (indels)
System Compatibility HiSeq 2000,MiSeq,NextSeq 550,HiSeq 3000,HiSeq 1000,MiSeqDx in Research Mode,MiniSeq,HiSeq 1500,NextSeq 500,MiSeq FGx in Research Mode,HiSeq 2500,HiSeq 4000
Species Category Other,Bovine,Mouse,Human,Rat
Specialized Sample Types FFPE,Low Input
Technology Sequencing
Automation CapABIlity Liquid Handling Robots
Method Amplicon Sequencing,Custom Sequencing
"
"Illumina/Nextera Rapid Capture Exome (8 rxn x 1 plex)/FC-140-1000/1 Ea
" Illumina 產(chǎn)品編號: FC-140-1000美 元 價: $2573.00會 員 價: 待定品 牌: Illumina產(chǎn) 地: 美國公 司: Illumina, Inc.產(chǎn)品分類: 分子類>二代測序>DNA文庫制備試劑盒公司分類: Library Preparation Kits "Product Highlights:
The Nextera Rapid Capture Exome and Expanded Exome are all-in-one kits for library preparation and exome enrichment that allow researchers to identify coding variants up to 70% faster than other methods. This optimized exome delivers 45 Mb of expertly selected exonic content and requires as little as 4 Gb of sequencing.
Extend coverage to UTRs and miRNA with Expanded Exome
Nextera Rapid Capture Expanded Exome delivers 62 Mb of genomic content, including exons, untranslated regions (UTRs), and miRNA. This kit features a highly optimized probe set that delivers comprehensive coverage of exonic sequence.
Illumina provides example data sets to demonstrate the high uniformity and accuracy of the Nextera Rapid Capture Exome library prep kit. View the exome sequencing data.
Add on custom content to make Nextera Rapid Capture Exome even more powerful
Researchers can define custom content for this workflow using Nextera Rapid Capture Custom Enrichment. This custom assay allows researchers to rapidly interrogate those portions of the human genome most important to their specific research. Choose from a fully custom design or start from a defined content set, such as Nextera Rapid Capture Exome, and include areas of interest using add-on functionality. Learn More.
Find an up-to-date list of high-throughput automation vendors with robotic systems compatIBLe with this library preparation kit
Specifications:
Assay Time 5 hours total assay time
Hands-On Time 4 hours
Input Quantity 1 ug DNA (compatIBLe with most large DNA genomes)
Mechanism of Action Mechanical fragmentation
Multiplexing Up to 96 dual-index combinations with HT (high-throughput) kit
Variant Class Small Insertions-Deletions (indels)
System Compatibility HiSeq 2000,NextSeq 550,HiSeq 3000,NextSeq 500,HiSeq 2500,HiSeq 4000
Specialized Sample Types Low Input
Technology Sequencing
Species Category Human
Automation CapABIlity Liquid Handling Robots
Method Exome Sequencing
"
"Illumina/TruSeq ChIP Sample Preparation Kit - Set B (12 indexes, 48 rxns)/IP-202-1024/1 Ea
" Illumina 產(chǎn)品編號: IP-202-1024美 元 價: $2783.00會 員 價: 待定品 牌: Illumina產(chǎn) 地: 美國公 司: Illumina, Inc.產(chǎn)品分類: 分子類>二代測序>DNA文庫制備試劑盒公司分類: Library Preparation Kits "Product Highlights:
TruSeq ChIP Libary Preparation Kits provide a simple, cost-effective solution for generating chromatin immunoprecipitation sequencing (ChIP-Seq) libraries from ChIP-derived DNA. ChIP-Seq leverages next-generation sequencing (NGS) to quickly and efficiently determine the distribution and abundance of DNA-bound protein targets of interest across the genome.
This method has become one of the most widely used NGS applications, enabling researchers to reliably and simultaneously identify binding sites of a broad range of targets across the entire genome, with high resolution and without constraints.
TruSeq ChIP Library Preparation Kits are compatIBLe with all Illumina sequencers. Offering the proven data quality and ease of use of TruSeq DNA sequencing, they provide a streamlined ChIP-Seq library preparation workflow that leverages reagent master mixes to minimize pipetting and reduce total assay time.
The kits have a low DNA input requirement and are compatIBLe with a range of sample sources. In addition, they offer more robust multiplex sequencing with 24 unique indexes, allowing researchers to optimize the distribution of sequencing output across samples based on read depth requirements.
Specifications:
Assay Time ~6.5 hours
Hands-On Time ~3.5 hours
Input Quantity 10 ng high-quality genomic DNA; 10 – 100 ng FFPE DNA (depending on QC results)
Mechanism of Action Probe hybridization, extension-ligation, and PCR
Multiplexing 1–96
Content Specifications Design custom probes to sequence genomic regions of interest. Content range: 4 – 650 kb"
"Illumina/Nextera XT Index Kit v2 Set C (96 indexes, 384 samples)/FC-131-2003/1 Ea
" Illumina 產(chǎn)品編號: FC-131-2003美 元 價: $989.00會 員 價: 待定品 牌: Illumina產(chǎn) 地: 美國公 司: Illumina, Inc.產(chǎn)品分類: 分子類>二代測序>DNA文庫制備試劑盒公司分類: Library Preparation Kits "Product Highlights:
Fast Library Prep, Optimized for Small Genomes, PCR Amplicons, and Plasmids
Rapid library preparation – complete library prep in as little as 90 minutes with only 15 minutes of hands-on time
Fast time to results – go from DNA to data in 8 hours with our benchtop sequencers.
Optimized for small genomes, PCR amplicons, and plasmids – one library prep kit for many applications
Innovative sample normalization – eliminates the need for library quantification before sample pooling and sequencing
With Nextera technology, DNA is simultaneously fragmented and tagged with sequencing adapters in a single tube enzymatic reaction. Nextera XT supports ultra-low DNA input of only 1 ng. It enables a wide range of input samples, including small genomes, PCR amplicons greater than 300 bp, plasmids, microbial genomes, concatenated amplicons, and double-stranded CDNA.
Multiplexing of up to 384 samples per Nextera XT library is also available for those projects requiring greater throughput. Plus, the kit includes an innovative bead-based sample normalization that eliminates the need for library quantification prior to pooling and sequencing. Libraries prepared with Nextera XT kits are compatIBLe with all Illumina sequencers.
Find an up-to-date list of high-throughput automation vendors with robotic systems compatIBLe with this library preparation kit
Specifications:
Assay Time 90 minutes
Hands-On Time 15 minutes
Mechanism of Action Enzymatic Fragmentation
Multiplexing Up to 384 uniquely indexed samples may be pooled and sequenced together.
Input Quantity 1 ng DNA
Species Category Drosophila,Any Species,Mammalian,Mouse,Yeast,Zebrafish,Human,Rat,Plant,Nematode,Bacteria
System Compatibility MiSeq,NextSeq 550,NextSeq 500,MiSeq FGx in Research Mode
Method Shotgun Sequencing,Whole-Genome Sequencing,De Novo Sequencing,16S rRNA Sequencing,Amplicon Sequencing,Targeted DNA Sequencing
Variant Class Single Nucleotide Polymorphisms (SNPs),Structural Variants
Specialized Sample Types Low Input,Single Cells
Technology Sequencing
Automation CapABIlity Liquid Handling Robots"
"Illumina/TruSeq Synthetic Long-Read DNA Barcode Kit (1 barcode plate)/FC-126-1002/1 Ea
" Illumina 產(chǎn)品編號: FC-126-1002美 元 價: $761.00會 員 價: 待定品 牌: Illumina產(chǎn) 地: 美國公 司: Illumina, Inc.產(chǎn)品分類: 分子類>二代測序>DNA文庫制備試劑盒公司分類: Library Preparation Kits "Product Highlights:
The TruSeq Synthetic Long-Read DNA Library Prep Kit is a highly accurate, end-to-end sequencing solution that can be used for genome assembly or genome phasing. Depending on the analysis option you select, you can use it to:
Assemble synthetically long reads for de novo assembly and genome finishing applications
Perform genome phasing to identify co-inherited alleles and haplotype information, as well as phase de novo mutations
Accurately Construct Synthetic Long Reads
The TruSeq Synthetic Long-Read DNA Library Prep and TruSeq Synthetic Long-Read DNA Barcode Kits are designed for preparing DNA libraries to generate synthetically long reads. The library prep kit combines TruSeq and Nextera chemistries with synthetic long-read technology to prepare DNA libraries. The accompanying barcode kit includes 384 indexes for labeling the samples in each well. These indexes are then used after sequencing to construct synthetically long fragments for long-read assembly and phasing analysis.
Simplified Informatics for Genome Assembly or Human Whole-Genome Phasing
After sequencing, push-button analysis in BaseSpace Sequence Hub simplifies assembly of long reads. Data can be transferred from an Illumina sequencing instrument to the BaseSpace Sequence Hub cloud instantly.
BaseSpace App for Genome Assembly:
The TruSeq Long-Read Assembly App constructs long, synthetic reads from shorter sequencing reads for accurate genome assembly and genome finishing. TruSeq synthetic long-read technology allows you to use the same familiar platform with a new application.
BaseSpace App for Phasing Analysis:
The TruSeq Phasing Analysis App can be used to perform whole human genome phasing, identifying haplotype information and co-inherited alleles, and phasing de novo mutations. By constructing synthetically long fragments from shorter sequencing reads, this method provides more comprehensive and accurate phasing compared to conventional trio studies or statistical inference.
Specifications:
Assay Time 3 days
Hands-On Time 6 hours
Species Category Any Species
System Compatibility HiSeq 2000,HiSeq 3000,HiSeq 2500,HiSeq 4000
Method Whole-Genome Sequencing,De Novo Sequencing,Long-Read Sequencing
Technology Sequencing
品牌介紹
"
"Illumina/TruSeq Stranded Total RNA Library Prep Kit with Ribo-Zero Human/Mouse/Rat High Throughput (96 samples, 96 index
" Illumina 產(chǎn)品編號: RS-122-2203美 元 價: $10280.00會 員 價: 待定品 牌: Illumina產(chǎn) 地: 美國公 司: Illumina, Inc.產(chǎn)品分類: 分子類>二代測序>DNA文庫制備試劑盒公司分類: Library Preparation Kits "Product Highlights:
The TruSeq Stranded Total Library Preparation kit provides a clear view of the transcriptome with a streamlined, cost-efficient, and scalable solution for total RNA analysis with sequencing.
Whole-Transcriptome Analysis with Precise Measurement of Strand Orientation
CompatIBLe with a wide range of samples, including low-quality and FFPE, TruSeq Stranded Total RNA kits couple all of the benefits of TruSeq RNA preparation kits with Ribo-Zero ribosomal RNA reduction chemistry, providing analysis of coding and multiple forms of noncoding RNA with precise measurement of strand orientation, uniform coverage, and high-confidence discovery of features such as alternative transcripts, gene fusions, and allele-specific expression.
Find an up-to-date list of high-throughput automation vendors with robotic systems compatIBLe with this library preparation kit
FlexIBLe Solutions for a Range of Study Designs
The TruSeq Stranded Total RNA Library Prep kit is available in multiple versions to fit specific study design needs:
TruSeq Stranded Total RNA with Ribo-Zero Human/Mouse/Rat removes cytoplasmic rRNA.
TruSeq Stranded Total RNA with Ribo-Zero Gold removes both cytoplasmic and mitochondrial rRNA.
The total RNA kits are also compatIBLe with the new unique dual index kits, TruSeq RNA Unique Dual Indexes, which allows multiplexing of up to 96 samples.
Species Compatibility
The TruSeq Stranded Total Library Preparation kit is designed for human, mouse and rat sequences, but may be applicable to a variety of eukaryotic species.*
*For information on a particular species of interest, contact Illumina Technical Support.
Specifications:
Input Quantity 0.1 – 1 ug high-quality total RNA. Lower-quality samples may require further optimization.
Content Specifications Captures coding RNA plus multiple forms of non-coding RNA
Mechanism of Action Bead-based rRNA depletion, CDNA synthesis, and PCR
Multiplexing Low-throughput kits: Pool up to 12 samples. Or pool up to 24 samples with sets A and B together,High-throughput kits: Prepare 96 uniquely indexed samples.
System Compatibility NovaSeq 5000,Genome Analyzer IIx,HiSeq 2000,NextSeq 550,HiSeq 3000,HiSeq 1000,HiSeq 1500,NextSeq 500,HiSeq 2500,NovaSeq 6000,HiSeq 4000
Variant Class Single Nucleotide Polymorphisms (SNPs),Gene Fusions,Novel Transcripts,Transcript Variants
Specialized Sample Types FFPE
Method Whole-Transcriptome Sequencing
Species Category Mouse,Human,Rat
Technology Sequencing
Automation CapABIlity Liquid Handling Robots"
"Illumina/TruSeq Nano DNA Library Prep Kit for NeoPrep (16 indexes, 16 samples)/NP-101-1001/1 Ea
" Illumina 產(chǎn)品編號: NP-101-1001美 元 價: $480.00會 員 價: 待定品 牌: Illumina產(chǎn) 地: 美國公 司: Illumina, Inc.產(chǎn)品分類: 分子類>二代測序>DNA文庫制備試劑盒公司分類: Library Preparation Kits "Product Highlights:
The TruSeq Nano DNA for NeoPrep offers a simple, all-inclusive prep solution, ideal for any whole-genome sequencing application. Run the same proven TruSeq Nano DNA biochemistry on the fully integrated digital microfluidics NeoPrep Library Prep System.
Simplified and seamless workflow solution – Includes onboard quantification and normalization to deliver sequencing-ready libraries
Exceptional performance and reproducibility – Generates libraries with TruSeq Nano DNA coverage and quality, with minimal hands-on time and reduced user variABIlity
Low input requirement – Requires as little as 25 ng genomic DNA to prepare high-quality, sequencing-ready libraries
Reduce Library Bias and Coverage Gaps
TruSeq Nano DNA library prep reduces the number and average size of typical PCR-induced gaps in coverage. The enhanced workflow reduces library bias and improves coverage uniformity across the genome. It also provides excellent coverage of trADItionally challenging genomic content, including GC-rich regions, promoters, and repetitive regions. This enables you to access more information from each sequencing run.
NeoPrep System enhances TruSeq Nano DNA performance
The NeoPrep System enhances TruSeq Nano DNA performance by providing high-quality reproducIBLe results, even with low input amounts of DNA. Digital microfluidics technology precisely manipulates droplets that perform the library prep workflow, including quantification and normalization within the tightly controlled environment of the NeoPrep library card.
A simple, intuitive workflow delivers 16 sequencing-ready libraries, eliminating almost all manual steps, and reducing hands-on time from ~4 hours to just 30 minutes. In addition, digital microfluidics requires less DNA input, enabling excellent performance from 25-75 ng of genomic DNA. Successful libraries have been demonstrated with DNA inputs ranging from 1–100 ng, up to 10-fold lower than required by manual protocols.
Specifications:
Assay Time 1 day
Hands-On Time 4 hours
Input Quantity 50 ng RNA,50 ng high-quality total RNA,≥ 200 ng FFPE total RNA; Recommended quantity may vary with expression level, target plexity, and sample quality
Content Specifications Choose from 400,000+ pre-designed targeted RNA-Seq assays. Or add content to a fixed panel or previously designed custom panel.
Multiplexing Up to 384 samples per sequencing run
Mechanism of Action Amplification
Method Shotgun Sequencing,Whole-Genome Sequencing,Genotyping by Sequencing
Variant Class Single Nucleotide Polymorphisms (SNPs),Gene Fusions,Loss of Heterozygosity (LOH),Somatic Variants,Chromosomal Abnormalities,Germline Variants,Structural Variants,Insertions-Deletions (indels),Copy Number Variants (CNVs)
Species Category Mammalian,Mouse,Human,Other,Rat,Plant
System Compatibility NextSeq 550,HiSeq 3000,HiSeq X Five,HiSeq 1000,MiSeqDx in Research Mode,MiniSeq,HiSeq 2000,MiSeq,HiSeq X Ten,NeoPrep,HiSeq 1500,NextSeq 500,HiSeq 2500,HiSeq 4000
Specialized Sample Types Low Input
Technology Sequencing
Automation CapABIlity NeoPrep Digital Microfluidics"
"Illumina/Nextera Rapid Capture Exome (4 rxn x 12 plex)/FC-140-1002/1 Ea
" Illumina 產(chǎn)品編號: FC-140-1002美 元 價: $7665.00會 員 價: 待定品 牌: Illumina產(chǎn) 地: 美國公 司: Illumina, Inc.產(chǎn)品分類: 分子類>二代測序>DNA文庫制備試劑盒公司分類: Library Preparation Kits "Product Highlights:
The Nextera Rapid Capture Exome and Expanded Exome are all-in-one kits for library preparation and exome enrichment that allow researchers to identify coding variants up to 70% faster than other methods. This optimized exome delivers 45 Mb of expertly selected exonic content and requires as little as 4 Gb of sequencing.
Extend coverage to UTRs and miRNA with Expanded Exome
Nextera Rapid Capture Expanded Exome delivers 62 Mb of genomic content, including exons, untranslated regions (UTRs), and miRNA. This kit features a highly optimized probe set that delivers comprehensive coverage of exonic sequence.
Illumina provides example data sets to demonstrate the high uniformity and accuracy of the Nextera Rapid Capture Exome library prep kit. View the exome sequencing data.
Add on custom content to make Nextera Rapid Capture Exome even more powerful
Researchers can define custom content for this workflow using Nextera Rapid Capture Custom Enrichment. This custom assay allows researchers to rapidly interrogate those portions of the human genome most important to their specific research. Choose from a fully custom design or start from a defined content set, such as Nextera Rapid Capture Exome, and include areas of interest using add-on functionality. Learn More.
Find an up-to-date list of high-throughput automation vendors with robotic systems compatIBLe with this library preparation kit
Specifications:
Assay Time 5 hours total assay time
Hands-On Time 4 hours
Input Quantity 1 ug DNA (compatIBLe with most large DNA genomes)
Mechanism of Action Mechanical fragmentation
Multiplexing Up to 96 dual-index combinations with HT (high-throughput) kit
Variant Class Small Insertions-Deletions (indels)
System Compatibility HiSeq 2000,NextSeq 550,HiSeq 3000,NextSeq 500,HiSeq 2500,HiSeq 4000
Specialized Sample Types Low Input
Technology Sequencing
Species Category Human
Automation CapABIlity Liquid Handling Robots
Method Exome Sequencing
"
"Illumina/MiSeq Reagent Nano Kit v2 (300-cycles)/MS-103-1001/1 Ea
" Illumina 產(chǎn)品編號: MS-103-1001美 元 價: $290.00會 員 價: 待定品 牌: Illumina產(chǎn) 地: 美國公 司: Illumina, Inc.產(chǎn)品分類: 分子類>二代測序>簇生成和測序試劑公司分類: Cluster Generation & Sequencing Reagents "Product Highlights:
MiSeq Reagent Kits v2 enable more output to simplify each MiSeq run. MiSeq Reagent Kits v2 retain the same pre-filled, ready-to-use reagent cartridges as the v1 kits, but offer improved chemistry to increase cluster density, decrease cycle time, and improve quality (Q) scores. MiSeq Reagent Kits v2 are also available in micro and nano formats for low output applications.
Get faster cycle times, longer reads and more output from improved chemistry
Dual surface imaging enables twice the number of reads compared to single surface imaging with the v1 kit
Extend your read lengths with the 500-cycle kit
Choose the perfect number of cycles for your application (50, 300, or 500)
When coupled with the MiSeq System upgrade, the MiSeq Reagent Kits v2 allow dual surface imaging to double the amount of readable space per flow cell. MiSeq Regent Kits v2 are available in a 500-cycle format for long read lengths, as well as in the popular 50-cycle and 300-cycle formats.
MiSeq Reagent Kits v2 are available in standard, micro, and nano configurations, enabling alignment to specific project requirements and scalable levels of output.
View product configurations
All MiSeq reagent components are RFID-encoded and interact intelligently with the MiSeq System to validate compatibility with user-defined applications.
A MiSeq Reagent Kit v3 is also available. It offers a 600-cycle format to allow the longest read lengths on any Illumina sequencing system, or a 150-cycle format that enables counting applications.
Specifications:
Maximum Output 8.5 Gb (500-cycle MiSeq Reagent Kit v2), 5.1 Gb (300-cycle MiSeq Reagent Kit v2), 1.2 Gb (300-cycle MiSeq Reagent Micro Kit v2), 0.850 Gb (50-cycle MiSeq Reagent Kit v2), 0.5 Gb (500-cycle MiSeq Reagent Nano Kit v2), 0.3 Gb (300-cycle MiSeq Reagent Nano Kit v2)
Maximum Reads per Run Up to 15 million
Reagent Type Paired-End Sequencing,Cluster Generation,Sequencing by Synthesis
System Compatibility MiSeq,MiSeqDx in Research Mode,MiSeq FGx in Research Mode
Technology Sequencing"
"Illumina/HiSeq PE Cluster Kit V4 - cBot/PE-401-4001/1 Ea
" Illumina 產(chǎn)品編號: PE-401-4001美 元 價: $6200.00會 員 價: 待定品 牌: Illumina產(chǎn) 地: 美國公 司: Illumina, Inc.產(chǎn)品分類: 分子類>二代測序>簇生成和測序試劑公司分類: Cluster Generation & Sequencing Reagents "Product Highlights:
The HiSeq PE (Paired-End) Cluster Kit v4 cBot provides reagents for the cBot cluster amplification system. DNA library samples are bound to complimentary adapter oligos grafted on the surface of the flow cell. The templates are copied from the hybridization primer by 3’ extension using a high fidelity DNA polymerase. Copies are isothermally amplified to create clonal clusters of ~1000 copies each, ready for sequencing on enabled HiSeq systems*.
Cluster generation reagents provided in a pre-mixed, 96 well plate format that requires minimal reagent preparation. The kit also included reagents for cluster resynthesis of the reverse strand, regenerated by bridge amplification within the paired-end flow cell. After resynthesis of the reverse strand, the original forward strand is cleaved and the reverse strand is sequenced for the second read."
"Illumina/Nextera DNA Flex Library Prep (96 Samples)/20018705/1 Ea
" Illumina 產(chǎn)品編號: 20018705美 元 價: $4032.00會 員 價: 待定品 牌: Illumina產(chǎn) 地: 美國公 司: Illumina, Inc.產(chǎn)品分類: 分子類>二代測序>DNA文庫制備試劑盒公司分類: Library Preparation Kits "Product Highlights:
The Nextera DNA Flex Library Prep Kit offers flexibility for many whole-genome sequencing applications.
Fastest Illumina library prep workflow, with ~3.5 hours total time
Flexibility to accommodate variations in sample type, DNA input amount, and application
Optimized library prep performance, generating reliable results
Save Time and Resources
The Nextera DNA Flex Library Prep Kit uses a fast, user-friendly workflow. On-bead tagmentation chemistry reduces total library prep time to ~3.5 hours, from DNA extraction to library normalization.
Simplify Lab Operations
The Nextera DNA Flex workflow supports a broad DNA input range (1–500 ng), multiple sample types, and both small and large genomes. The workflow includes DNA extraction from blood, saliva, or dried blood spots*or bacterial colonies*. Gain the flexibility to sequence human or other large, complex genomes as well as amplicons or microbial species, all with a single kit.
Obtain Reliable Results
While accommodating various study requirements, the Nextera DNA Flex workflow delivers consistent insert sizes, uniform coverage, and optimized performance, regardless of DNA input amount or genome size. The bead-based technology minimizes bias and opportunities for error, resulting in highly reproducIBLe sequencing data.
*Demonstrated protocols available.
Specifications:
Assay Time ~3.5 hours total assay time
Hands-On Time 1-1.5 hours
Input Quantity Small Genomes: 1-500 ng DNA; Large Genomes: 100-500 ng
Content Specifications Human Whole Genome, Small Whole Genome, Large Whole Genome
Mechanism of Action Bead-linked transposome
Multiplexing Up to 96 available indexes
Species Category Any Species
System Compatibility MiSeq,HiSeq X Ten,NextSeq 550,HiSeq 3000,HiSeq X Five,MiSeqDx in Research Mode,MiniSeq,HiSeq 2500,NovaSeq 6000,HiSeq 4000
Variant Class Single Nucleotide Polymorphisms (SNPs),Gene Fusions,Loss of Heterozygosity (LOH),Somatic Variants,Chromosomal Abnormalities,Germline Variants,Structural Variants,Insertions-Deletions (indels),Copy Number Variants (CNVs)
Method Whole-Genome Sequencing
Technology Sequencing
Automation CapABIlity Liquid Handling Robots"
"Illumina/TruSeq Stranded Total RNA Library Prep Kit with Ribo-Zero Human/Mouse/Rat Set B (48 samples, 12 indexes)/RS-122
" Illumina 產(chǎn)品編號: RS-122-2202美 元 價: $5630.00會 員 價: 待定品 牌: Illumina產(chǎn) 地: 美國公 司: Illumina, Inc.產(chǎn)品分類: 分子類>二代測序>DNA文庫制備試劑盒公司分類: Library Preparation Kits "Product Highlights:
The TruSeq Stranded Total Library Preparation kit provides a clear view of the transcriptome with a streamlined, cost-efficient, and scalable solution for total RNA analysis with sequencing.
Whole-Transcriptome Analysis with Precise Measurement of Strand Orientation
CompatIBLe with a wide range of samples, including low-quality and FFPE, TruSeq Stranded Total RNA kits couple all of the benefits of TruSeq RNA preparation kits with Ribo-Zero ribosomal RNA reduction chemistry, providing analysis of coding and multiple forms of noncoding RNA with precise measurement of strand orientation, uniform coverage, and high-confidence discovery of features such as alternative transcripts, gene fusions, and allele-specific expression.
Find an up-to-date list of high-throughput automation vendors with robotic systems compatIBLe with this library preparation kit
FlexIBLe Solutions for a Range of Study Designs
The TruSeq Stranded Total RNA Library Prep kit is available in multiple versions to fit specific study design needs:
TruSeq Stranded Total RNA with Ribo-Zero Human/Mouse/Rat removes cytoplasmic rRNA.
TruSeq Stranded Total RNA with Ribo-Zero Gold removes both cytoplasmic and mitochondrial rRNA.
The total RNA kits are also compatIBLe with the new unique dual index kits, TruSeq RNA Unique Dual Indexes, which allows multiplexing of up to 96 samples.
Species Compatibility
The TruSeq Stranded Total Library Preparation kit is designed for human, mouse and rat sequences, but may be applicable to a variety of eukaryotic species.*
*For information on a particular species of interest, contact Illumina Technical Support.
Specifications:
Input Quantity 0.1 – 1 ug high-quality total RNA. Lower-quality samples may require further optimization.
Content Specifications Captures coding RNA plus multiple forms of non-coding RNA
Mechanism of Action Bead-based rRNA depletion, CDNA synthesis, and PCR
Multiplexing Low-throughput kits: Pool up to 12 samples. Or pool up to 24 samples with sets A and B together,High-throughput kits: Prepare 96 uniquely indexed samples.
System Compatibility NovaSeq 5000,Genome Analyzer IIx,HiSeq 2000,NextSeq 550,HiSeq 3000,HiSeq 1000,HiSeq 1500,NextSeq 500,HiSeq 2500,NovaSeq 6000,HiSeq 4000
Variant Class Single Nucleotide Polymorphisms (SNPs),Gene Fusions,Novel Transcripts,Transcript Variants
Specialized Sample Types FFPE
Method Whole-Transcriptome Sequencing
Species Category Mouse,Human,Rat
Technology Sequencing
Automation CapABIlity Liquid Handling Robots"
"Illumina/TruSeq DNA PCR-Free HT Library Preparation Kit (96 indexes in plate format, 96 samples)/FC-121-3003/1 Ea
" Illumina 產(chǎn)品編號: FC-121-3003美 元 價: $3000.00會 員 價: 待定品 牌: Illumina產(chǎn) 地: 美國公 司: Illumina, Inc.產(chǎn)品分類: 分子類>二代測序>DNA文庫制備試劑盒公司分類: Library Preparation Kits "Product Highlights:
TruSeq DNA PCR-Free Library Preparation Kits provide simple, all-inclusive library preparation for whole-genome sequencing applications. Researchers can sequence a wide variety of organisms, from small genomes such as bacteria to human whole-genomes. The kits offer:
Shortened gel-free workflows that remove the need for PCR
ABIlity to sequence the most challenging regions
Improved genome coverage to identify the greatest number of variants
Sequence the most challenging regions
TruSeq DNA PCR-free kits offer superior coverage of areas which are trADItionally difficult to sequence such as high GC-rich regions, promoters, and repetitive content.
The kits are tunable to a variety of read lengths and are supported on all Illumina sequencing instruments. This permits the researcher to tailor each run to the needs of the experiment.
Detect the greatest number of variants
PCR-free means reduced library bias and gaps. The result is unsurpassed data quality. This enables you to detect the greatest number of variants. Excellent genome coverage means your results have the lowest and smallest number of gaps and enhanced coverage of high G/C rich regions.
Use PCR-free for faster protocols
Removing PCR creates a faster protocol and superior data quality. Bead-based size selection shortens the workflow. In tandem with Illumina sequencing systems, the TruSeq DNA PCR-Free Library Preparation Kit provides a range of enhancements to the industry's most widely adopted library preparation workflow.
Access flexIBLe throughput options
Kits include reagents, sample purification beads, and indexes, with two options for flexibility:
TruSeq DNA PCR-Free LT Library Preparation Kits support 24-plex manual processing for low-throughput studies.
TruSeq DNA PCR-Free HT Library Preparation Kits are 96-plex for high-throughput studies, and can be automated on liquid handling robots (or processed manually).
Find an up-to-date list of automation vendors with robotic systems that support the HT library preparation kits
Specifications:
Input Quantity 0.1 – 1 ug high-quality purified total RNA from blood
Content Specifications Captures coding RNA plus multiple forms of non-coding RNA
Mechanism of Action Bead-based rRNA depletion, CDNA synthesis, and PCR
Multiplexing Low-throughput kits: Pool up to 12 samples. Or pool up to 24 samples with sets A and B together,High-throughput kit version: Prepare 96 uniquely indexed samples
System Compatibility NovaSeq 5000,Genome Analyzer IIx,HiSeq 2000,NextSeq 500,HiSeq 2500,NextSeq 550,HiSeq 3000,HiSeq 1000
Automation CapABIlity Liquid Handling Robots
Variant Class Transcript Variants,Single Nucleotide Polymorphisms (SNPs),Gene Fusions
Species Category Rat,Mouse
Method Whole-Transcriptome Sequencing
Technology Sequencing"
"Illumina/Nextera DNA CD Indexes (96 Indexes, 96 Samples)/20018708/1 Ea
" Illumina 產(chǎn)品編號: 20018708美 元 價: $480.00會 員 價: 待定品 牌: Illumina產(chǎn) 地: 美國公 司: Illumina, Inc.產(chǎn)品分類: 分子類>二代測序>DNA文庫制備試劑盒公司分類: Library Preparation Kits "Product Highlights:
The Nextera DNA Flex Library Prep Kit offers flexibility for many whole-genome sequencing applications.
Fastest Illumina library prep workflow, with ~3.5 hours total time
Flexibility to accommodate variations in sample type, DNA input amount, and application
Optimized library prep performance, generating reliable results
Save Time and Resources
The Nextera DNA Flex Library Prep Kit uses a fast, user-friendly workflow. On-bead tagmentation chemistry reduces total library prep time to ~3.5 hours, from DNA extraction to library normalization.
Simplify Lab Operations
The Nextera DNA Flex workflow supports a broad DNA input range (1–500 ng), multiple sample types, and both small and large genomes. The workflow includes DNA extraction from blood, saliva, or dried blood spots*or bacterial colonies*. Gain the flexibility to sequence human or other large, complex genomes as well as amplicons or microbial species, all with a single kit.
Obtain Reliable Results
While accommodating various study requirements, the Nextera DNA Flex workflow delivers consistent insert sizes, uniform coverage, and optimized performance, regardless of DNA input amount or genome size. The bead-based technology minimizes bias and opportunities for error, resulting in highly reproducIBLe sequencing data.
*Demonstrated protocols available.
Specifications:
Assay Time ~3.5 hours total assay time
Hands-On Time 1-1.5 hours
Input Quantity Small Genomes: 1-500 ng DNA; Large Genomes: 100-500 ng
Content Specifications Human Whole Genome, Small Whole Genome, Large Whole Genome
Mechanism of Action Bead-linked transposome
Multiplexing Up to 96 available indexes
Species Category Any Species
System Compatibility MiSeq,HiSeq X Ten,NextSeq 550,HiSeq 3000,HiSeq X Five,MiSeqDx in Research Mode,MiniSeq,HiSeq 2500,NovaSeq 6000,HiSeq 4000
Variant Class Single Nucleotide Polymorphisms (SNPs),Gene Fusions,Loss of Heterozygosity (LOH),Somatic Variants,Chromosomal Abnormalities,Germline Variants,Structural Variants,Insertions-Deletions (indels),Copy Number Variants (CNVs)
Method Whole-Genome Sequencing
Technology Sequencing
Automation CapABIlity Liquid Handling Robots"
"Illumina/Nextera Rapid Capture Expanded Exome (4 rxn x 12 plex)/FC-140-1005/1 Ea
" Illumina 產(chǎn)品編號: FC-140-1005美 元 價: $8946.00會 員 價: 待定品 牌: Illumina產(chǎn) 地: 美國公 司: Illumina, Inc.產(chǎn)品分類: 分子類>二代測序>DNA文庫制備試劑盒公司分類: Library Preparation Kits "Product Highlights:
The Nextera Rapid Capture Exome and Expanded Exome are all-in-one kits for library preparation and exome enrichment that allow researchers to identify coding variants up to 70% faster than other methods. This optimized exome delivers 45 Mb of expertly selected exonic content and requires as little as 4 Gb of sequencing.
Extend coverage to UTRs and miRNA with Expanded Exome
Nextera Rapid Capture Expanded Exome delivers 62 Mb of genomic content, including exons, untranslated regions (UTRs), and miRNA. This kit features a highly optimized probe set that delivers comprehensive coverage of exonic sequence.
Illumina provides example data sets to demonstrate the high uniformity and accuracy of the Nextera Rapid Capture Exome library prep kit. View the exome sequencing data.
Add on custom content to make Nextera Rapid Capture Exome even more powerful
Researchers can define custom content for this workflow using Nextera Rapid Capture Custom Enrichment. This custom assay allows researchers to rapidly interrogate those portions of the human genome most important to their specific research. Choose from a fully custom design or start from a defined content set, such as Nextera Rapid Capture Exome, and include areas of interest using add-on functionality. Learn More.
Find an up-to-date list of high-throughput automation vendors with robotic systems compatIBLe with this library preparation kit
Specifications:
Assay Time 5 hours total assay time
Hands-On Time 4 hours
Input Quantity 1 ug DNA (compatIBLe with most large DNA genomes)
Mechanism of Action Mechanical fragmentation
Multiplexing Up to 96 dual-index combinations with HT (high-throughput) kit
Variant Class Small Insertions-Deletions (indels)
System Compatibility HiSeq 2000,NextSeq 550,HiSeq 3000,NextSeq 500,HiSeq 2500,HiSeq 4000
Specialized Sample Types Low Input
Technology Sequencing
Species Category Human
Automation CapABIlity Liquid Handling Robots
Method Exome Sequencing
"
"Illumina/TruSeq Custom Amplicon Filter Plate (1 plate)/FC-130-1006/1 Ea
" Illumina 產(chǎn)品編號: FC-130-1006美 元 價: $51.00會 員 價: 待定品 牌: Illumina產(chǎn) 地: 美國公 司: Illumina, Inc.產(chǎn)品分類: 分子類>二代測序>DNA文庫制備試劑盒公司分類: Library Preparation Kits "Product Highlights:
TruSeq Custom Amplicon is a fully customizable, amplicon-based assay for targeted resequencing. The assay enables you to focus interrogation on key regions of genomic interest. Up to 1536 amplicons can be sequenced in a single reaction using a simple workflow. This highly targeted approach offers unparalleled efficiency for discovering, validating, and screening genetic variants in areas of research focus.
Requiring as little as 50 ng of input genomic DNA (gDNA), this kit can be used with a wide range of sample types. The ABIlity to multiplex up to 1536 amplicons per reaction allows coverage of up to 650 kb of cumulative sequence. Further, an integrated dual indexing scheme supports up to 96 samples per run, enabling you to fully benefit from desktop sequencer output capABIlities.
This assay provides improved performance in difficult to address GC-rich regions, as well as increased library yield, uniformity, and stABIlity. Additionally, optimized amplification steps enable sample input requirements to drop from 150 ng to 50 ng.
Simplified Probe Design
Design targeted TruSeq Custom Amplicon oligonucleotide probes with DesignStudio, a free, easy-to-use online tool that provides optimized coverage.
Learn more about DesignStudio
Start a project in DesignStudio now (login required)
Simple Data Analysis
Automated data analysis using the BaseSpace TruSeq Amplicon App allows researchers to easily review project data, including variants detected, across multiple runs.
Species Compatibility
TruSeq Custom Amplicon supports human, mouse, rat, and bovine samples. DesignStudio design algorithms are also available for maize, rice, pig, dog, soybean, chicken, and sheep; however, assay performance cannot be guaranteed as the resulting assays have not been tested. In addition, Illumina Concierge services can design custom assays and/or provide assay optimization support for any species of interest.
Inquire about Illumina Concierge services
Find an up-to-date list of high-throughput automation vendors with robotic systems compatIBLe with this library preparation kit
Specifications:
Assay Time 1 day
Hands-On Time 4 hours
Input Quantity 50 ng RNA,50 ng high-quality total RNA,≥ 200 ng FFPE total RNA; Recommended quantity may vary with expression level, target plexity, and sample quality
Content Specifications Choose from 400,000+ pre-designed targeted RNA-Seq assays. Or add content to a fixed panel or previously designed custom panel.
Multiplexing Up to 384 samples per sequencing run
Mechanism of Action Amplification
Variant Class Short Tandem Repeats (STRs),Single Nucleotide Polymorphisms (SNPs),Gene Fusions,Loss of Heterozygosity (LOH),Somatic Variants,Chromosomal Abnormalities,Germline Variants,Structural Variants,Insertions-Deletions (indels)
System Compatibility HiSeq 2000,MiSeq,NextSeq 550,HiSeq 3000,HiSeq 1000,MiSeqDx in Research Mode,MiniSeq,HiSeq 1500,NextSeq 500,MiSeq FGx in Research Mode,HiSeq 2500,HiSeq 4000
Species Category Other,Bovine,Mouse,Human,Rat
Specialized Sample Types FFPE
Technology Sequencing
Automation CapABIlity Liquid Handling Robots
Method Amplicon Sequencing,Custom Sequencing"
"Illumina/Nextera XT Index Kit v2 Set D (96 indexes, 384 samples)/FC-131-2004/1 Ea
" Illumina 產(chǎn)品編號: FC-131-2004美 元 價: $989.00會 員 價: 待定品 牌: Illumina產(chǎn) 地: 美國公 司: Illumina, Inc.產(chǎn)品分類: 分子類>二代測序>DNA文庫制備試劑盒公司分類: Library Preparation Kits "Product Highlights:
Fast Library Prep, Optimized for Small Genomes, PCR Amplicons, and Plasmids
Rapid library preparation – complete library prep in as little as 90 minutes with only 15 minutes of hands-on time
Fast time to results – go from DNA to data in 8 hours with our benchtop sequencers.
Optimized for small genomes, PCR amplicons, and plasmids – one library prep kit for many applications
Innovative sample normalization – eliminates the need for library quantification before sample pooling and sequencing
With Nextera technology, DNA is simultaneously fragmented and tagged with sequencing adapters in a single tube enzymatic reaction. Nextera XT supports ultra-low DNA input of only 1 ng. It enables a wide range of input samples, including small genomes, PCR amplicons greater than 300 bp, plasmids, microbial genomes, concatenated amplicons, and double-stranded CDNA.
Multiplexing of up to 384 samples per Nextera XT library is also available for those projects requiring greater throughput. Plus, the kit includes an innovative bead-based sample normalization that eliminates the need for library quantification prior to pooling and sequencing. Libraries prepared with Nextera XT kits are compatIBLe with all Illumina sequencers.
Find an up-to-date list of high-throughput automation vendors with robotic systems compatIBLe with this library preparation kit
Specifications:
Assay Time 90 minutes
Hands-On Time 15 minutes
Mechanism of Action Enzymatic Fragmentation
Multiplexing Up to 384 uniquely indexed samples may be pooled and sequenced together.
Input Quantity 1 ng DNA
Species Category Drosophila,Any Species,Mammalian,Mouse,Yeast,Zebrafish,Human,Rat,Plant,Nematode,Bacteria
System Compatibility MiSeq,NextSeq 550,NextSeq 500,MiSeq FGx in Research Mode
Method Shotgun Sequencing,Whole-Genome Sequencing,De Novo Sequencing,16S rRNA Sequencing,Amplicon Sequencing,Targeted DNA Sequencing
Variant Class Single Nucleotide Polymorphisms (SNPs),Structural Variants
Specialized Sample Types Low Input,Single Cells
Technology Sequencing
Automation CapABIlity Liquid Handling Robots"
"Illumina/NextSeq 500/550 High Output v2 kit (300 cycles)/FC-404-2004/1 Ea
" Illumina 產(chǎn)品編號: FC-404-2004美 元 價: $4450.00會 員 價: 待定品 牌: Illumina產(chǎn) 地: 美國公 司: Illumina, Inc.產(chǎn)品分類: 分子類>二代測序>簇生成和測序試劑公司分類: Cluster Generation & Sequencing Reagents "Product Highlights:
NextSeq 500/550 v2 sequencing reagent kits bring the power of a high-throughput sequencing system to the desktop, now with improved data quality and the highest yield of error-free reads. These kits offer:
Robust base calling and improved signal-to-noise ratio
Multiple options for both sequencing output and read length
Simplified reagent cartridge configurations, with improved workflow and cartridge loADIng
Intuitive labeling and RFID-encoded reagents
Optimized chemistry with the latest in sequencing by synthesis (SBS) and bridge-amplification cluster generation
The kits deliver powerful sequencing chemistries with as little as 10 minutes of hands-on time. Intuitive labeling and RFID-encoded reagents ensure compatibility with user-defined run configurations.
Ready-to-use cartridges redefine ease-of-use
Pre-configured reagent kits for the NextSeq Series Systems provide all the components needed for sequencing on the platform in 3 ready-to-use cartridges (reagent, flow cell, and buffer). The kits offer simplified cartridge loADIng with the bleach and dual-indexing primers already in the cartridge.
Simply load user-prepared library pools directly into the NextSeq reagent cartridge. The system automatically performs all steps necessary for template amplification and sequencing without user intervention.
Specifications:
Maximum Output 120 Gb (300-cycle high output kit), 60 Gb (150-cycle high output kit), 39 Gb (300-cycle mid output kit), 30 Gb (75-cycle high output kit), 19.5 Gb (150-cycle mid output kit)
Maximum Reads per Run 400 million clusters (high output kits), 130 million clusters (mid output kits)
Reagent Type Paired-End Sequencing,Cluster Generation,Sequencing by Synthesis,Single-Read Sequencing
System Compatibility NextSeq 550,NextSeq 500
Technology Sequencing"
"Illumina/MiniSeq High Output Reagent Kit (150-cycles)/FC-420-1002/1 Ea
" Illumina 產(chǎn)品編號: FC-420-1002美 元 價: $965.00會 員 價: 待定品 牌: Illumina產(chǎn) 地: 美國公 司: Illumina, Inc.產(chǎn)品分類: 分子類>二代測序>簇生成和測序試劑公司分類: Cluster Generation & Sequencing Reagents "Product Highlights:
MiniSeq System sequencing reagent kits bring the power and reliABIlity of proven Illumina next-generation sequencing (NGS) to labs of all sizes. Access cost-efficient sequencing with high data quality, even for low numbers of samples. These kits offer:
Robust base calling and optimal signal-to-noise ratio
Multiple options for both sequencing output and read length
Simple workflow that reduces chance for error through the integration of clustering, sequencing and wash reagents into a single cartridge
Intuitive labeling and RFID-encoded reagents
Optimized chemistry with the latest in Illumina sequencing by synthesis (SBS) chemistry
Configurations for various applications
MiniSeq Reagent Kits offer a wide range of solutions for applications ranging from gene expression and small RNA profiling to targeted DNA amplicon sequencing and small genome sequencing. High accuracy and paired-end sequencing capABIlity are built into every reagent kit.
Ready-to-use cartridges redefine ease of use
Preconfigured reagent kits for the MiniSeq System provide all the components needed for cluster generation, sequencing and wash on the platform in 1 premixed, integrated, RFID-enabled cartridge. Simply load user-prepared library pools directly into the MiniSeq System. The system automatically performs all steps necessary for template amplification and sequencing without user intervention.
The kits deliver powerful sequencing chemistries with as little as 10 minutes of hands-on time. Intuitive labeling and RFID-encoded reagents ensure compatibility with user-defined run configurations.
Specifications:
Maximum Output 7.5 Gb (300-cycle high output kit), 3.75 Gb (150-cycle high output kit), 2.4 Gb (300-cycle mid output kit), 1.875 Gb (75-cycle high output kit)
Maximum Reads Per Run Up to 25 million (high output kits), Up to 8 million (mid output kits)
Reagent Type Paired-End Sequencing,Cluster Generation,Sequencing by Synthesis
Technology Sequencing
System Compatibility MiniSeq"
"Illumina/TruSeq® Exome Kit (8 rxn × 6 plex)/FC-150-1002/1 Ea
" Illumina 產(chǎn)品編號: FC-150-1002美 元 價: $3360.00會 員 價: 待定品 牌: Illumina產(chǎn) 地: 美國公 司: Illumina, Inc.產(chǎn)品分類: 分子類>二代測序>DNA文庫制備試劑盒公司分類: Library Preparation Kits "Product Highlights:
TruSeq Exome Library Prep Kit is a cost-effective library preparation and exome enrichment solution with industry-leADIng accuracy. It offers:
Pre-enrichment library pooling and optimal coverage for low-cost exome sequencing
Mechanical shearing and TruSeq enrichment technology that yield uniform coverage and greater than or equal to 80% on-target sequencing reads
Fully supported workflow solution to simplify exome sequencing
Cost-Effective Exome Sequencing
The TruSeq Exome Library Prep Kit supports 12-plex pre-enrichment library pooling, enabling researchers to maximize sequencing throughput and identify variants in less time by sequencing up to 12 libraries per flow cell lane. The high on-target percentage requires fewer sequencing cycles to reach the optimal level of coverage, while still achieving high coverage uniformity for confident results. It also enables sequencing of more exomes per run, so researchers can maximize their budgets.
To learn more about calculating coverage estimates, see the sequencing coverage calculator.
Proven TruSeq Data Quality
The TruSeq Exome Library Prep Kit delivers ≥ 80% of on-target sequencing reads for efficient, cost-effective exome sequencing. By combining the TruSeq Exome Library Prep Kit with Illumina systems using sequencing by synthesis (SBS) technology, researchers can identify true coding variants and minimize false-positive and false-negative calls.
Convenient, Integrated Workflow Solution
Illumina provides an integrated, fully supported workflow solution that guides researchers from library preparation through analysis. All components of the exome sequencing workflow are designed, optimized, and analytically validated together. Expert Illumina scientists provide a single source of technical and field support for every step in the process.
Find an up-to-date list of high-throughput automation vendors with robotic systems compatIBLe with this library preparation kit
Specifications:
Assay Time 2.5 days
Hands-On Time 6 hours
Input Quantity 100 ng genomic DNA
Content Specifications Captures coding exons. Covers 45 Mb of exonic content (≥98% of RefSeq, CCDS, and Ensembl coding content).
Mechanism of Action Mechanical fragmentation (COVARIS) and exome enrichment with biotinylated capture probes
Multiplexing Up to 12-plex enrichment
System Compatibility NovaSeq 5000,NextSeq 550,HiSeq 3000,NextSeq 500,NovaSeq 6000,HiSeq 4000
Specialized Sample Types FFPE
Technology Sequencing
Species Category Human
Automation CapABIlity Liquid Handling Robots
Method Exome Sequencing"
"Illumina/Infinium FFPE QC Kit (384 reactions)/WG-321-1001/1 Ea
" Illumina 產(chǎn)品編號: WG-321-1001美 元 價: $99.00會 員 價: 待定品 牌: Illumina產(chǎn) 地: 美國公 司: Illumina, Inc.產(chǎn)品分類: 分子類>二代測序>DNA文庫制備試劑盒公司分類: Library Preparation Kits "Product Highlights:
TruSeq Custom Amplicon is a fully customizable, amplicon-based assay for targeted resequencing. The assay enables you to focus interrogation on key regions of genomic interest. Up to 1536 amplicons can be sequenced in a single reaction using a simple workflow. This highly targeted approach offers unparalleled efficiency for discovering, validating, and screening genetic variants in areas of research focus.
Requiring as little as 50 ng of input genomic DNA (gDNA), this kit can be used with a wide range of sample types. The ABIlity to multiplex up to 1536 amplicons per reaction allows coverage of up to 650 kb of cumulative sequence. Further, an integrated dual indexing scheme supports up to 96 samples per run, enabling you to fully benefit from desktop sequencer output capABIlities.
This assay provides improved performance in difficult to address GC-rich regions, as well as increased library yield, uniformity, and stABIlity. Additionally, optimized amplification steps enable sample input requirements to drop from 150 ng to 50 ng.
Simplified Probe Design
Design targeted TruSeq Custom Amplicon oligonucleotide probes with DesignStudio, a free, easy-to-use online tool that provides optimized coverage.
Learn more about DesignStudio
Start a project in DesignStudio now (login required)
Simple Data Analysis
Automated data analysis using the BaseSpace TruSeq Amplicon App allows researchers to easily review project data, including variants detected, across multiple runs.
Species Compatibility
TruSeq Custom Amplicon supports human, mouse, rat, and bovine samples. DesignStudio design algorithms are also available for maize, rice, pig, dog, soybean, chicken, and sheep; however, assay performance cannot be guaranteed as the resulting assays have not been tested. In addition, Illumina Concierge services can design custom assays and/or provide assay optimization support for any species of interest.
Inquire about Illumina Concierge services
Find an up-to-date list of high-throughput automation vendors with robotic systems compatIBLe with this library preparation kit
Specifications:
Assay Time 1 day
Hands-On Time 4 hours
Input Quantity 50 ng RNA,50 ng high-quality total RNA,≥ 200 ng FFPE total RNA; Recommended quantity may vary with expression level, target plexity, and sample quality
Content Specifications Choose from 400,000+ pre-designed targeted RNA-Seq assays. Or add content to a fixed panel or previously designed custom panel.
Multiplexing Up to 384 samples per sequencing run
Mechanism of Action Amplification
Variant Class Short Tandem Repeats (STRs),Single Nucleotide Polymorphisms (SNPs),Gene Fusions,Loss of Heterozygosity (LOH),Somatic Variants,Chromosomal Abnormalities,Germline Variants,Structural Variants,Insertions-Deletions (indels)
System Compatibility HiSeq 2000,MiSeq,NextSeq 550,HiSeq 3000,HiSeq 1000,MiSeqDx in Research Mode,MiniSeq,HiSeq 1500,NextSeq 500,MiSeq FGx in Research Mode,HiSeq 2500,HiSeq 4000
Species Category Other,Bovine,Mouse,Human,Rat
Specialized Sample Types FFPE
Technology Sequencing
Automation CapABIlity Liquid Handling Robots
Method Amplicon Sequencing,Custom Sequencing"
"Illumina/HiSeq SBS Kit V4 250 cycle kit/FC-401-4003/1 Ea
" Illumina 產(chǎn)品編號: FC-401-4003美 元 價: $10100.00會 員 價: 待定品 牌: Illumina產(chǎn) 地: 美國公 司: Illumina, Inc.產(chǎn)品分類: 分子類>二代測序>簇生成和測序試劑公司分類: Cluster Generation & Sequencing Reagents "Product Highlights:
HiSeq SBS Kit v4 kits contain ready-to-load reagents for accurately determining the DNA sequence of each cluster on a flow cell using sequencing by synthesis (SBS) technology on enabled HiSeq sequencing systems* run in high output mode.
The HiSeq SBS v4 kits enable up to 1000 gigabases (Gb) of output per 6-day dual flow cell run using the HiSeq PE Cluster Kit v4 cBot. These kits contain sufficient volumes to support dual-indexing applications – no additional SBS reagents are required.
HiSeq v4 chemistry allows all reagents to be loaded onto the instrument before beginning the run. To perform a HiSeq v4 run, you need 1 HiSeq SBS Kit v4. Each kit includes sufficient reagents for sequencing 1 flow cell.
*HiSeq Systems require the latest hardware configuration. Check with your local sales rep regarding system compatibility.
Note: This kit is NOT compatIBLe with the Genome Analyzer.
FlexIBLe Run Configurations
You can choose from single-read or paired-end read runs, with read lengths up to 2×125 bp in high output mode. If longer read lengths are desired, rapid run SBS kits enable up to 2×250 bp.
A Broad Range of Applications
These kits enable a wide variety of applications, from ChIP-Seq to whole-genome sequencing, splice variant detection, and more. They enable researchers, in a single run, to process up to†:
10 genomes
156 exomes
80 whole-transcriptome RNA samples
†Assumes 100 Gb per genome at 2x125 bp, 5 Gb per exome at 2x100 bp with TruSeq Exome or TruSeq Rapid Exome kits, and 50 million reads per transcriptome.
This product is also available as an Illumina Advantage product. Illumina Advantage large-scale sequencing products feature lot-specific shipments and testing, extended shelf life, and advanced change notifications for greater laboratory efficiency.
Specifications:
Maximum Output Up to 1000 Gb per dual flow cell run
Maximum Reads per Run Up to 4 billion
System Compatibility HiSeq 2000,HiSeq 1500,HiSeq 2500
Reagent Type Sequencing by Synthesis
Technology Sequencing
"
"Illumina/Nextera XT Index Kit v2 Set A (96 indexes, 384 samples)/FC-131-2001/1 Ea
" Illumina 產(chǎn)品編號: FC-131-2001美 元 價: $989.00會 員 價: 待定品 牌: Illumina產(chǎn) 地: 美國公 司: Illumina, Inc.產(chǎn)品分類: 分子類>二代測序>DNA文庫制備試劑盒公司分類: Library Preparation Kits "Product Highlights:
Fast Library Prep, Optimized for Small Genomes, PCR Amplicons, and Plasmids
Rapid library preparation – complete library prep in as little as 90 minutes with only 15 minutes of hands-on time
Fast time to results – go from DNA to data in 8 hours with our benchtop sequencers.
Optimized for small genomes, PCR amplicons, and plasmids – one library prep kit for many applications
Innovative sample normalization – eliminates the need for library quantification before sample pooling and sequencing
With Nextera technology, DNA is simultaneously fragmented and tagged with sequencing adapters in a single tube enzymatic reaction. Nextera XT supports ultra-low DNA input of only 1 ng. It enables a wide range of input samples, including small genomes, PCR amplicons greater than 300 bp, plasmids, microbial genomes, concatenated amplicons, and double-stranded CDNA.
Multiplexing of up to 384 samples per Nextera XT library is also available for those projects requiring greater throughput. Plus, the kit includes an innovative bead-based sample normalization that eliminates the need for library quantification prior to pooling and sequencing. Libraries prepared with Nextera XT kits are compatIBLe with all Illumina sequencers.
Find an up-to-date list of high-throughput automation vendors with robotic systems compatIBLe with this library preparation kit
Specifications:
Assay Time 90 minutes
Hands-On Time 15 minutes
Mechanism of Action Enzymatic Fragmentation
Multiplexing Up to 384 uniquely indexed samples may be pooled and sequenced together.
Input Quantity 1 ng DNA
Species Category Drosophila,Any Species,Mammalian,Mouse,Yeast,Zebrafish,Human,Rat,Plant,Nematode,Bacteria
System Compatibility MiSeq,NextSeq 550,NextSeq 500,MiSeq FGx in Research Mode
Method Shotgun Sequencing,Whole-Genome Sequencing,De Novo Sequencing,16S rRNA Sequencing,Amplicon Sequencing,Targeted DNA Sequencing
Variant Class Single Nucleotide Polymorphisms (SNPs),Structural Variants
Specialized Sample Types Low Input,Single Cells
Technology Sequencing
Automation CapABIlity Liquid Handling Robots"
"Illumina/HiSeq X Ten Reagent Kit v2.5 - 10 pack/FC-501-2521/1 Ea
" Illumina 產(chǎn)品編號: FC-501-2521美 元 價: $127500.00會 員 價: 待定品 牌: Illumina產(chǎn) 地: 美國公 司: Illumina, Inc.產(chǎn)品分類: 分子類>二代測序>簇生成和測序試劑公司分類: Cluster Generation & Sequencing Reagents "Product Highlights:
HiSeq X Reagent Kits support high coverage whole-genome sequencing (WGS) with the HiSeq X Series of sequencing systems. By leveraging patterned flow cells, these kits provide increased cluster density to enable significant increases in data output and daily throughput. HiSeq X Reagent Kits support industry-leADIng library preparation options while offering superior data quality and coverage.
HiSeq X Reagent Kits support the TruSeq DNA PCR-Free Library Preparation Kit, for industry-best coverage of challenging genomic regions, and the TruSeq Nano DNA Library Preparation Kit, for efficient sequencing of samples with limited available DNA. Together, the reagent kits and library preparation options deliver exceptional genome coverage, enabling highly accurate and comprehensive variant calling for WGS on the HiSeq X Ten and the HiSeq X Five Systems. The HiSeq X Reagent Kits:
Deliver ultra-high data output
Provide ultra-high daily throughput
Enable sequencing up to 16 genomes per run
Are available in single and multipack configurations
Are compatIBLe with TruSeq DNA PCR-Free and TruSeq Nano DNA LibraryPreparation Kits
HiSeq X Reagent Kits are only compatIBLe with the HiSeq X Series of sequencing systems. HiSeq X Ten Reagent Kits are only available for purchase by HiSeq X Ten users and the HiSeq X Five Reagent Kits are only available for purchase by HiSeq X Five users. Reagents are also available in a multipack configuration to support bulk purchasing with significant reductions in packaging materials.
Latest technology innovation powers population-scale sequencing
HiSeq X Reagent Kits leverage the newest format in Illumina flow cell technology to achieve ultra-high-throughput WGS. Patterned flow cells contain billions of nanowell substrates at fixed locations across both surfaces of the flow cell. The structured organization (see below) provides even spacing of sequencing clusters to deliver significant increases in sequencing reads and total output of the system.
Specifications:
Maximum Output Up to 1800 Gb (1 HiSeq X System with dual flow cells)
Maximum Reads per Run Up to 6 billion
Reagent Type Paired-End Sequencing,Cluster Generation
System Compatibility HiSeq X Ten,HiSeq X Five
Technology Sequencing
"
"Illumina/HiSeq 3000/4000 SBS Kit (300 cycles)/FC-410-1003/1 Ea
" Illumina 產(chǎn)品編號: FC-410-1003美 元 價: $9900.00會 員 價: 待定品 牌: Illumina產(chǎn) 地: 美國公 司: Illumina, Inc.產(chǎn)品分類: 分子類>二代測序>簇生成和測序試劑公司分類: Cluster Generation & Sequencing Reagents "Product Highlights:
HiSeq 3000/4000 SBS (Sequencing by Synthesis) Kits support a wide range of sequencing applications, making them ideal for high-throughput labs performing various genomic applications. CompatIBLe with the HiSeq 3000 and HiSeq 4000 Sequencing Systems, the new kits leverage patterned flow cell technology for even cluster spacing and uniform feature size, to deliver extremely high cluster densities and significant increases in data output and daily throughput.
The HiSeq 3000/4000 SBS Kits enable up to 1500 Gb (1.5 Tb) of output per dual flow cell run when used with the HiSeq 3000/4000 PE Cluster Kit. This high capacity means that more samples can be sequenced simultaneously at a great depth, generating rich and meaningful data.
Specifications:
Maximum Output Up to 1500 Gb (HiSeq 4000 with 2 flow cells), Up to 750 Gb (HiSeq 3000)
Maximum Reads Up to 5 billion (HiSeq 4000), Up to 2.5 billion (HiSeq 3000)
Reagent Type Sequencing by Synthesis
System Compatibility HiSeq 3000,HiSeq 4000
Technology Sequencing"
"Illumina/TruSeq Synthetic Long-Read DNA Library Prep Kit (4 samples)/FC-126-1001/1 Ea
" Illumina 產(chǎn)品編號: FC-126-1001美 元 價: $488.00會 員 價: 待定品 牌: Illumina產(chǎn) 地: 美國公 司: Illumina, Inc.產(chǎn)品分類: 分子類>二代測序>DNA文庫制備試劑盒公司分類: Library Preparation Kits "Product Highlights:
The TruSeq Synthetic Long-Read DNA Library Prep Kit is a highly accurate, end-to-end sequencing solution that can be used for genome assembly or genome phasing. Depending on the analysis option you select, you can use it to:
Assemble synthetically long reads for de novo assembly and genome finishing applications
Perform genome phasing to identify co-inherited alleles and haplotype information, as well as phase de novo mutations
Accurately Construct Synthetic Long Reads
The TruSeq Synthetic Long-Read DNA Library Prep and TruSeq Synthetic Long-Read DNA Barcode Kits are designed for preparing DNA libraries to generate synthetically long reads. The library prep kit combines TruSeq and Nextera chemistries with synthetic long-read technology to prepare DNA libraries. The accompanying barcode kit includes 384 indexes for labeling the samples in each well. These indexes are then used after sequencing to construct synthetically long fragments for long-read assembly and phasing analysis.
Simplified Informatics for Genome Assembly or Human Whole-Genome Phasing
After sequencing, push-button analysis in BaseSpace Sequence Hub simplifies assembly of long reads. Data can be transferred from an Illumina sequencing instrument to the BaseSpace Sequence Hub cloud instantly.
BaseSpace App for Genome Assembly:
The TruSeq Long-Read Assembly App constructs long, synthetic reads from shorter sequencing reads for accurate genome assembly and genome finishing. TruSeq synthetic long-read technology allows you to use the same familiar platform with a new application.
BaseSpace App for Phasing Analysis:
The TruSeq Phasing Analysis App can be used to perform whole human genome phasing, identifying haplotype information and co-inherited alleles, and phasing de novo mutations. By constructing synthetically long fragments from shorter sequencing reads, this method provides more comprehensive and accurate phasing compared to conventional trio studies or statistical inference.
Specifications:
Assay Time 3 days
Hands-On Time 6 hours
Species Category Any Species
System Compatibility HiSeq 2000,HiSeq 3000,HiSeq 2500,HiSeq 4000
Method Whole-Genome Sequencing,De Novo Sequencing,Long-Read Sequencing
Technology Sequencing
品牌介紹
"
"Illumina/HiSeq X Five Reagent Kit v2.5 - 10 pack/FC-502-2521/1 Ea
" Illumina 產(chǎn)品編號: FC-502-2521美 元 價: $191250.00會 員 價: 待定品 牌: Illumina產(chǎn) 地: 美國公 司: Illumina, Inc.產(chǎn)品分類: 分子類>二代測序>簇生成和測序試劑公司分類: Cluster Generation & Sequencing Reagents "Product Highlights:
HiSeq X Reagent Kits support high coverage whole-genome sequencing (WGS) with the HiSeq X Series of sequencing systems. By leveraging patterned flow cells, these kits provide increased cluster density to enable significant increases in data output and daily throughput. HiSeq X Reagent Kits support industry-leADIng library preparation options while offering superior data quality and coverage.
HiSeq X Reagent Kits support the TruSeq DNA PCR-Free Library Preparation Kit, for industry-best coverage of challenging genomic regions, and the TruSeq Nano DNA Library Preparation Kit, for efficient sequencing of samples with limited available DNA. Together, the reagent kits and library preparation options deliver exceptional genome coverage, enabling highly accurate and comprehensive variant calling for WGS on the HiSeq X Ten and the HiSeq X Five Systems. The HiSeq X Reagent Kits:
Deliver ultra-high data output
Provide ultra-high daily throughput
Enable sequencing up to 16 genomes per run
Are available in single and multipack configurations
Are compatIBLe with TruSeq DNA PCR-Free and TruSeq Nano DNA LibraryPreparation Kits
HiSeq X Reagent Kits are only compatIBLe with the HiSeq X Series of sequencing systems. HiSeq X Ten Reagent Kits are only available for purchase by HiSeq X Ten users and the HiSeq X Five Reagent Kits are only available for purchase by HiSeq X Five users. Reagents are also available in a multipack configuration to support bulk purchasing with significant reductions in packaging materials.
Latest technology innovation powers population-scale sequencing
HiSeq X Reagent Kits leverage the newest format in Illumina flow cell technology to achieve ultra-high-throughput WGS. Patterned flow cells contain billions of nanowell substrates at fixed locations across both surfaces of the flow cell. The structured organization (see below) provides even spacing of sequencing clusters to deliver significant increases in sequencing reads and total output of the system.
Specifications:
Maximum Output Up to 1800 Gb (1 HiSeq X System with dual flow cells)
Maximum Reads per Run Up to 6 billion
Reagent Type Paired-End Sequencing,Cluster Generation
System Compatibility HiSeq X Ten,HiSeq X Five
Technology Sequencing
"
"Illumina/TruSeq Stranded Total RNA Library Prep Kit with Ribo-Zero Human/Mouse/Rat Set A (48 samples, 12 indexes)/RS-122
" Illumina 產(chǎn)品編號: RS-122-2201美 元 價: $5630.00會 員 價: 待定品 牌: Illumina產(chǎn) 地: 美國公 司: Illumina, Inc.產(chǎn)品分類: 分子類>二代測序>DNA文庫制備試劑盒公司分類: Library Preparation Kits "Product Highlights:
The TruSeq Stranded Total Library Preparation kit provides a clear view of the transcriptome with a streamlined, cost-efficient, and scalable solution for total RNA analysis with sequencing.
Whole-Transcriptome Analysis with Precise Measurement of Strand Orientation
CompatIBLe with a wide range of samples, including low-quality and FFPE, TruSeq Stranded Total RNA kits couple all of the benefits of TruSeq RNA preparation kits with Ribo-Zero ribosomal RNA reduction chemistry, providing analysis of coding and multiple forms of noncoding RNA with precise measurement of strand orientation, uniform coverage, and high-confidence discovery of features such as alternative transcripts, gene fusions, and allele-specific expression.
Find an up-to-date list of high-throughput automation vendors with robotic systems compatIBLe with this library preparation kit
FlexIBLe Solutions for a Range of Study Designs
The TruSeq Stranded Total RNA Library Prep kit is available in multiple versions to fit specific study design needs:
TruSeq Stranded Total RNA with Ribo-Zero Human/Mouse/Rat removes cytoplasmic rRNA.
TruSeq Stranded Total RNA with Ribo-Zero Gold removes both cytoplasmic and mitochondrial rRNA.
The total RNA kits are also compatIBLe with the new unique dual index kits, TruSeq RNA Unique Dual Indexes, which allows multiplexing of up to 96 samples.
Species Compatibility
The TruSeq Stranded Total Library Preparation kit is designed for human, mouse and rat sequences, but may be applicable to a variety of eukaryotic species.*
*For information on a particular species of interest, contact Illumina Technical Support.
Specifications:
Input Quantity 0.1 – 1 ug high-quality total RNA. Lower-quality samples may require further optimization.
Content Specifications Captures coding RNA plus multiple forms of non-coding RNA
Mechanism of Action Bead-based rRNA depletion, CDNA synthesis, and PCR
Multiplexing Low-throughput kits: Pool up to 12 samples. Or pool up to 24 samples with sets A and B together,High-throughput kits: Prepare 96 uniquely indexed samples.
System Compatibility NovaSeq 5000,Genome Analyzer IIx,HiSeq 2000,NextSeq 550,HiSeq 3000,HiSeq 1000,HiSeq 1500,NextSeq 500,HiSeq 2500,NovaSeq 6000,HiSeq 4000
Variant Class Single Nucleotide Polymorphisms (SNPs),Gene Fusions,Novel Transcripts,Transcript Variants
Specialized Sample Types FFPE
Method Whole-Transcriptome Sequencing
Species Category Mouse,Human,Rat
Technology Sequencing
Automation CapABIlity Liquid Handling Robots"
"Illumina/MiSeq Reagent Kit v2 (50-cycles)/MS-102-2001/1 Ea
" Illumina 產(chǎn)品編號: MS-102-2001美 元 價: $820.00會 員 價: 待定品 牌: Illumina產(chǎn) 地: 美國公 司: Illumina, Inc.產(chǎn)品分類: 分子類>二代測序>簇生成和測序試劑公司分類: Cluster Generation & Sequencing Reagents "Product Highlights:
MiSeq Reagent Kits v2 enable more output to simplify each MiSeq run. MiSeq Reagent Kits v2 retain the same pre-filled, ready-to-use reagent cartridges as the v1 kits, but offer improved chemistry to increase cluster density, decrease cycle time, and improve quality (Q) scores. MiSeq Reagent Kits v2 are also available in micro and nano formats for low output applications.
Get faster cycle times, longer reads and more output from improved chemistry
Dual surface imaging enables twice the number of reads compared to single surface imaging with the v1 kit
Extend your read lengths with the 500-cycle kit
Choose the perfect number of cycles for your application (50, 300, or 500)
When coupled with the MiSeq System upgrade, the MiSeq Reagent Kits v2 allow dual surface imaging to double the amount of readable space per flow cell. MiSeq Regent Kits v2 are available in a 500-cycle format for long read lengths, as well as in the popular 50-cycle and 300-cycle formats.
MiSeq Reagent Kits v2 are available in standard, micro, and nano configurations, enabling alignment to specific project requirements and scalable levels of output.
View product configurations
All MiSeq reagent components are RFID-encoded and interact intelligently with the MiSeq System to validate compatibility with user-defined applications.
A MiSeq Reagent Kit v3 is also available. It offers a 600-cycle format to allow the longest read lengths on any Illumina sequencing system, or a 150-cycle format that enables counting applications.
Specifications:
Maximum Output 8.5 Gb (500-cycle MiSeq Reagent Kit v2), 5.1 Gb (300-cycle MiSeq Reagent Kit v2), 1.2 Gb (300-cycle MiSeq Reagent Micro Kit v2), 0.850 Gb (50-cycle MiSeq Reagent Kit v2), 0.5 Gb (500-cycle MiSeq Reagent Nano Kit v2), 0.3 Gb (300-cycle MiSeq Reagent Nano Kit v2)
Maximum Reads per Run Up to 15 million
Reagent Type Paired-End Sequencing,Cluster Generation,Sequencing by Synthesis
System Compatibility MiSeq,MiSeqDx in Research Mode,MiSeq FGx in Research Mode
Technology Sequencing"
"Illumina/HiSeq SBS Kit V4 50 cycle kit/FC-401-4002/1 Ea
" Illumina 產(chǎn)品編號: FC-401-4002美 元 價: $2370.00會 員 價: 待定品 牌: Illumina產(chǎn) 地: 美國公 司: Illumina, Inc.產(chǎn)品分類: 分子類>二代測序>簇生成和測序試劑公司分類: Cluster Generation & Sequencing Reagents "Product Highlights:
HiSeq SBS Kit v4 kits contain ready-to-load reagents for accurately determining the DNA sequence of each cluster on a flow cell using sequencing by synthesis (SBS) technology on enabled HiSeq sequencing systems* run in high output mode.
The HiSeq SBS v4 kits enable up to 1000 gigabases (Gb) of output per 6-day dual flow cell run using the HiSeq PE Cluster Kit v4 cBot. These kits contain sufficient volumes to support dual-indexing applications – no additional SBS reagents are required.
HiSeq v4 chemistry allows all reagents to be loaded onto the instrument before beginning the run. To perform a HiSeq v4 run, you need 1 HiSeq SBS Kit v4. Each kit includes sufficient reagents for sequencing 1 flow cell.
*HiSeq Systems require the latest hardware configuration. Check with your local sales rep regarding system compatibility.
Note: This kit is NOT compatIBLe with the Genome Analyzer.
FlexIBLe Run Configurations
You can choose from single-read or paired-end read runs, with read lengths up to 2×125 bp in high output mode. If longer read lengths are desired, rapid run SBS kits enable up to 2×250 bp.
A Broad Range of Applications
These kits enable a wide variety of applications, from ChIP-Seq to whole-genome sequencing, splice variant detection, and more. They enable researchers, in a single run, to process up to†:
10 genomes
156 exomes
80 whole-transcriptome RNA samples
†Assumes 100 Gb per genome at 2x125 bp, 5 Gb per exome at 2x100 bp with TruSeq Exome or TruSeq Rapid Exome kits, and 50 million reads per transcriptome.
This product is also available as an Illumina Advantage product. Illumina Advantage large-scale sequencing products feature lot-specific shipments and testing, extended shelf life, and advanced change notifications for greater laboratory efficiency.
Specifications:
Maximum Output Up to 1000 Gb per dual flow cell run
Maximum Reads per Run Up to 4 billion
System Compatibility HiSeq 2000,HiSeq 1500,HiSeq 2500
Reagent Type Sequencing by Synthesis
Technology Sequencing
"
"Illumina/TruSeq Stranded Total RNA Library Prep Kit with Ribo-Zero Gold Set A (48 samples, 12 indexes)/RS-122-2301/1 Ea
" Illumina 產(chǎn)品編號: RS-122-2301美 元 價: $5630.00會 員 價: 待定品 牌: Illumina產(chǎn) 地: 美國公 司: Illumina, Inc.產(chǎn)品分類: 分子類>二代測序>DNA文庫制備試劑盒公司分類: Library Preparation Kits "Product Highlights:
The TruSeq Stranded Total Library Preparation kit provides a clear view of the transcriptome with a streamlined, cost-efficient, and scalable solution for total RNA analysis with sequencing.
Whole-Transcriptome Analysis with Precise Measurement of Strand Orientation
CompatIBLe with a wide range of samples, including low-quality and FFPE, TruSeq Stranded Total RNA kits couple all of the benefits of TruSeq RNA preparation kits with Ribo-Zero ribosomal RNA reduction chemistry, providing analysis of coding and multiple forms of noncoding RNA with precise measurement of strand orientation, uniform coverage, and high-confidence discovery of features such as alternative transcripts, gene fusions, and allele-specific expression.
Find an up-to-date list of high-throughput automation vendors with robotic systems compatIBLe with this library preparation kit
FlexIBLe Solutions for a Range of Study Designs
The TruSeq Stranded Total RNA Library Prep kit is available in multiple versions to fit specific study design needs:
TruSeq Stranded Total RNA with Ribo-Zero Human/Mouse/Rat removes cytoplasmic rRNA.
TruSeq Stranded Total RNA with Ribo-Zero Gold removes both cytoplasmic and mitochondrial rRNA.
The total RNA kits are also compatIBLe with the new unique dual index kits, TruSeq RNA Unique Dual Indexes, which allows multiplexing of up to 96 samples.
Species Compatibility
The TruSeq Stranded Total Library Preparation kit is designed for human, mouse and rat sequences, but may be applicable to a variety of eukaryotic species.*
*For information on a particular species of interest, contact Illumina Technical Support.
Specifications:
Input Quantity 0.1 – 1 ug high-quality total RNA. Lower-quality samples may require further optimization.
Content Specifications Captures coding RNA plus multiple forms of non-coding RNA
Mechanism of Action Bead-based rRNA depletion, CDNA synthesis, and PCR
Multiplexing Low-throughput kits: Pool up to 12 samples. Or pool up to 24 samples with sets A and B together,High-throughput kits: Prepare 96 uniquely indexed samples.
System Compatibility NovaSeq 5000,Genome Analyzer IIx,HiSeq 2000,NextSeq 550,HiSeq 3000,HiSeq 1000,HiSeq 1500,NextSeq 500,HiSeq 2500,NovaSeq 6000,HiSeq 4000
Variant Class Single Nucleotide Polymorphisms (SNPs),Gene Fusions,Novel Transcripts,Transcript Variants
Specialized Sample Types FFPE
Method Whole-Transcriptome Sequencing
Species Category Mouse,Human,Rat
Technology Sequencing
Automation CapABIlity Liquid Handling Robots"
"Illumina/HiSeq SR Rapid Cluster Kit v2/GD-402-4002/1 Ea
" Illumina 產(chǎn)品編號: GD-402-4002美 元 價: $930.00會 員 價: 待定品 牌: Illumina產(chǎn) 地: 美國公 司: Illumina, Inc.產(chǎn)品分類: 分子類>二代測序>簇生成和測序試劑公司分類: Cluster Generation & Sequencing Reagents "Product Highlights:
HiSeq Rapid Cluster Kits v2 enable the unique on-board cluster generation process. HiSeq Rapid Cluster Kits v2 are designed to be used in the rapid run mode of HiSeq 2500 and 1500 sequencers.
Optimize your workflow with on-board cluster generation
Improve turnaround time and batching efficiency
Maximize the data quality of your runs
Choose on-board cluster generation to optimize your workflow – On-board cluster generation is a unique high-throughput workflow option enabled by HiSeq Rapid Cluster Kits v2, and is only available in the rapid run mode of the HiSeq 2500 or 1500.
Clonal template clusters are generated from individual template strands directly on the HiSeq 2500 and 1500 instrument using this process. On-board cluster generation minimizes hands-on time and enables a true walkaway solution for high-throughput sequencing needs.
Turn samples around faster – HiSeq Rapid Cluster Kits v2 support the rapid run workflow for the HiSeq 2500 and 1500, and allow you to turn urgent samples around faster.
The lower overall data throughput of rapid run mode also simplifies batching requirements and allows optimal indexing of small genomes and other applications with reduced output needs.
Maximize data quality – HiSeq Rapid Cluster Kits v2 are specifically formulated to work with HiSeq Rapid SBS Kits v2 and provide the highest quality sequencing data available on any high-throughput sequencing system.
HiSeq Rapid Cluster Kits v2 improve cluster density robustness to increase total usable clusters in a given run and decrease cluster grADIents down the lane. This increased robustness and uniformity contribute to higher Q-scores, lower error rates, and higher data quality."
"Illumina/TruSeq SR Cluster Kit v3-cBot-HS/GD-401-3001/1 Ea
" Illumina 產(chǎn)品編號: GD-401-3001美 元 價: $4050.00會 員 價: 待定品 牌: Illumina產(chǎn) 地: 美國公 司: Illumina, Inc.產(chǎn)品分類: 分子類>二代測序>簇生成和測序試劑公司分類: Cluster Generation & Sequencing Reagents "Product Highlights:
For use with HiSeq 2500, HiSeq 2000, and HiSeq 1000 instruments with cBot, the TruSeq SR Cluster Kit v3-cBot-HS provides reagents that bind samples to complementary adapter oligos for cluster amplification on single-read flow cells.
The TruSeq SR Cluster Kit v3-cBot-HS contains cluster generation reagents for the cBot cluster amplification system in a pre-mixed, 96-well plate format that requires minimal reagent preparation.
DNA library samples are bound to complementary adapter oligos grafted on the surface of the flow cell. The templates are copied from the hybridized primer by 3' extension using a high fidelity DNA polymerase. These copies are isothermally amplified to create clonal clusters of ~1,000 copies each, ready for sequencing."
"Illumina/MiSeq Reagent Micro Kit v2 (300-cycles)/MS-103-1002/1 Ea
" Illumina 產(chǎn)品編號: MS-103-1002美 元 價: $440.00會 員 價: 待定品 牌: Illumina產(chǎn) 地: 美國公 司: Illumina, Inc.產(chǎn)品分類: 分子類>二代測序>簇生成和測序試劑公司分類: Cluster Generation & Sequencing Reagents "Product Highlights:
MiSeq Reagent Kits v2 enable more output to simplify each MiSeq run. MiSeq Reagent Kits v2 retain the same pre-filled, ready-to-use reagent cartridges as the v1 kits, but offer improved chemistry to increase cluster density, decrease cycle time, and improve quality (Q) scores. MiSeq Reagent Kits v2 are also available in micro and nano formats for low output applications.
Get faster cycle times, longer reads and more output from improved chemistry
Dual surface imaging enables twice the number of reads compared to single surface imaging with the v1 kit
Extend your read lengths with the 500-cycle kit
Choose the perfect number of cycles for your application (50, 300, or 500)
When coupled with the MiSeq System upgrade, the MiSeq Reagent Kits v2 allow dual surface imaging to double the amount of readable space per flow cell. MiSeq Regent Kits v2 are available in a 500-cycle format for long read lengths, as well as in the popular 50-cycle and 300-cycle formats.
MiSeq Reagent Kits v2 are available in standard, micro, and nano configurations, enabling alignment to specific project requirements and scalable levels of output.
View product configurations
All MiSeq reagent components are RFID-encoded and interact intelligently with the MiSeq System to validate compatibility with user-defined applications.
A MiSeq Reagent Kit v3 is also available. It offers a 600-cycle format to allow the longest read lengths on any Illumina sequencing system, or a 150-cycle format that enables counting applications.
Specifications:
Maximum Output 8.5 Gb (500-cycle MiSeq Reagent Kit v2), 5.1 Gb (300-cycle MiSeq Reagent Kit v2), 1.2 Gb (300-cycle MiSeq Reagent Micro Kit v2), 0.850 Gb (50-cycle MiSeq Reagent Kit v2), 0.5 Gb (500-cycle MiSeq Reagent Nano Kit v2), 0.3 Gb (300-cycle MiSeq Reagent Nano Kit v2)
Maximum Reads per Run Up to 15 million
Reagent Type Paired-End Sequencing,Cluster Generation,Sequencing by Synthesis
System Compatibility MiSeq,MiSeqDx in Research Mode,MiSeq FGx in Research Mode
Technology Sequencing"
"Illumina/TruSeq Stranded Total RNA Kit with Ribo-Zero Plant, Set A (48 samples, 12 indexes)/RS-122-2401/1 Ea
" Illumina 產(chǎn)品編號: RS-122-2401美 元 價: $5630.00會 員 價: 待定品 牌: Illumina產(chǎn) 地: 美國公 司: Illumina, Inc.產(chǎn)品分類: 分子類>二代測序>DNA文庫制備試劑盒公司分類: Library Preparation Kits "Product Highlights:
High-Quality Whole-Transcriptome Analysis with Precise Strand Information
RNA-Seq technology provides uniform coverage, precise measurement of strand orientation and high-confidence discovery of features such as alternative transcripts, antisense expression and allele-specific expression across both coding and multiple forms of noncoding RNA. The TruSeq Stranded Total RNA with Ribo-Zero Plant Kit couples the benefits of TruSeq RNA library preparation with Ribo-Zero ribosomal RNA reduction chemistry, providing a robust and scalable solution for whole-transcriptome analysis.
Find an up-to-date list of high-throughput automation vendors with robotic systems compatIBLe with this library preparation kit
Efficient Ribosomal RNA Reduction Across a Range of Plant Species, Study Designs
The TruSeq Stranded Total RNA with Ribo-Zero Plant Kit enables rapid and specific removal of cytoplasmic, mitochondrial and chloroplast ribosomal RNA from leaf, seed, and root tissue. The kit has been validated for use in multiple plant species, including ArABIdopsis thaliana, rice, and maize, and will provide efficient rRNA removal in a broad range of additional species.*
*For information on a particular species of interest, contact Illumina Technical Support.
Specifications:
Assay Time ~6.5 hours
Hands-On Time ~3.5 hours
Input Quantity 10 ng high-quality genomic DNA; 10 – 100 ng FFPE DNA (depending on QC results)
Mechanism of Action Probe hybridization, extension-ligation, and PCR
Multiplexing 1–96
Content Specifications Design custom probes to sequence genomic regions of interest. Content range: 4 – 650 kb
Variant Class Short Tandem Repeats (STRs),Single Nucleotide Polymorphisms (SNPs),Gene Fusions,Loss of Heterozygosity (LOH),Somatic Variants,Chromosomal Abnormalities,Germline Variants,Structural Variants,Insertions-Deletions (indels)
System Compatibility HiSeq 2000,MiSeq,NextSeq 550,HiSeq 3000,HiSeq 1000,MiSeqDx in Research Mode,MiniSeq,HiSeq 1500,NextSeq 500,MiSeq FGx in Research Mode,HiSeq 2500,HiSeq 4000
Species Category Other,Bovine,Mouse,Human,Rat
Specialized Sample Types FFPE,Low Input
Technology Sequencing
Automation CapABIlity Liquid Handling Robots
Method Amplicon Sequencing,Custom Sequencing
"
"Illumina/TruSeq Rapid Exome (8 rxn x 1 plex)/FC-144-1000/1 Ea
" Illumina 產(chǎn)品編號: FC-144-1000美 元 價: $2400.00會 員 價: 待定品 牌: Illumina產(chǎn) 地: 美國公 司: Illumina, Inc.產(chǎn)品分類: 分子類>二代測序>DNA文庫制備試劑盒公司分類: Library Preparation Kits "Product Highlights:
The TruSeq Rapid Exome Library Prep Kit delivers a simple, efficient method for high-confidence calling of exonic variants. The fast library preparation and exome enrichment workflow deliver libraries in 1 day with no need for additional equipment, giving labs the flexibility to plan projects according to sample volume. This kit offers:
Enhanced transposome chemistry results in reduced bias, providing consistent library preparation and exome enrichment.
Rapid, automation-friendly workflow completes in 1 day with only 3 hours of hands-on time.
High coverage uniformity across exonic regions and on-target %
Proven TruSeq Data Quality
The TruSeq Rapid Exome Library Prep Kit delivers an average of 75% of on-target sequencing reads. This high on-target percentage requires fewer sequencing cycles to reach desired coverage levels, but still achieves uniform coverage for high-confidence results.
To learn more about calculating coverage estimates, see the sequencing coverage calculator.
Find an up-to-date list of high-throughput automation vendors with robotic systems compatIBLe with this library preparation kit
Specifications:
Assay Time 1 day
Hands-On Time 3 hours
Input Quantity 50 ng genomic DNA
Content Specifications Captures coding exons. Covers 45 Mb of exonic content (≥98% of RefSeq, CCDS, and Ensembl coding content).
Mechanism of Action Transposase-based fragmentation and exome enrichment with biotinylated capture probes
Multiplexing Up to 12-plex enrichment
Technology Sequencing
Species Category Human
Automation CapABIlity Liquid Handling Robots
System Compatibility NextSeq 500,NovaSeq 6000,HiSeq 4000
Method Exome Sequencing
"
"Illumina/TruSeq RNA Access Library Prep Kit - Set B (12 indexes, 48 samples)/RS-301-2002/1 Ea
" Illumina 產(chǎn)品編號: RS-301-2002美 元 價: $7492.00會 員 價: 待定品 牌: Illumina產(chǎn) 地: 美國公 司: Illumina, Inc.產(chǎn)品分類: 分子類>二代測序>DNA文庫制備試劑盒公司分類: Library Preparation Kits "Product Highlights:
TruSeq RNA Access kits convert total RNA into template molecules of known strand origin, followed by sequence-specific capture of coding RNA. This provides a low-cost solution for analyzing human RNA isolated from FFPE (formalin-fixed, paraffin-embedded) tissues and other low-quality samples.
AffordABIlity and focus - isolating human transcriptome coding regions maximizes discovery power at a fraction of the sequencing depth
High-quality data from difficult samples - optimized for sequencing RNA from degraded samples, including FFPE tissues
Samples with limited starting material - greatly reduced sample input requirements (as little as 10 ng total RNA from fresh or frozen samples or 20 ng total RNA from degraded samples) while maintaining high sensitivity
TruSeq RNA Access Kit generates RNA-Seq libraries from degraded samples that focus on the RNA coding regions. Isolating these high-value content regions maximizes discovery power, while requiring only a fraction of the read depth of total RNA sequencing. The results are low input requirements, high sample throughput, and cost-effective transcriptome analysis.
Find an up-to-date list of high-throughput automation vendors with robotic systems compatIBLe with this library preparation kit
Specifications:
Assay Time ~2 Days
Hands-on Time ~11 hours
Input Quantity 10 ng total RNA from fresh/frozen samples, or 20 ng total RNA from FFPE samples
Content Specifications Captures the coding transcriptome/RNA exome
Mechanism of Action Biotinylated capture probes that target coding RNA. Does not require RNA with poly-A tails.
Multiplexing Up to 24 unique indexes and 4-plex pre-enrichment pooling
System Compatibility NovaSeq 5000,NextSeq 550,HiSeq 3000,NextSeq 500,HiSeq 2500,NovaSeq 6000,HiSeq 4000
Variant Class Single Nucleotide Polymorphisms (SNPs),Novel Transcripts,Transcript Variants
Specialized Sample Types FFPE,Low Input
Technology Sequencing
Method mRNA Sequencing,Exome Sequencing
Species Category Human
Automation CapABIlity Liquid Handling Robots"
"Illumina/HiSeq Rapid SBS Kit v2 (50 cycles)/FC-402-4022/1 Ea
" Illumina 產(chǎn)品編號: FC-402-4022美 元 價: $545.00會 員 價: 待定品 牌: Illumina產(chǎn) 地: 美國公 司: Illumina, Inc.產(chǎn)品分類: 分子類>二代測序>簇生成和測序試劑公司分類: Cluster Generation & Sequencing Reagents "Product Highlights:
HiSeq Rapid v2 SBS Kits enable the longest reads on HiSeq instruments, with reads up to 2x250 bp. The new kits generate up to 300 Gb of data per run. HiSeq Rapid SBS Kits v2 are the ideal choice for sequencing on HiSeq systems. These kits:
Maximize the data quality of your runs
Improve turnaround time and batching efficiency
Provide multiple kit configurations
Allow you to set up once and walk away
Maximize data quality – HiSeq Rapid SBS Kits v2 are formulated to provide the highest data quality with reads up to 2x250 bp. Building on the well-established SBS chemistry, HiSeq Rapid SBS Kits integrate innovative features that increase Q-scores, decrease error rates and deliver unparalleled data quality.
Turn samples faster – HiSeq Rapid SBS Kits v2 support the rapid run workflow for the HiSeq 2500 and 1500, and allow you to turn urgent samples around fast. The lower overall data throughput of rapid run mode also simplifies batching requirements and allows optimal indexing of small genomes and other applications with reduced output needs.
Kit configurations – HiSeq Rapid SBS Kits v2 are available in three configurations: 500 cycle, 200 cycle, and 50 cycle. All HiSeq Rapid SBS v2 Kits provide sufficient reagents to support single or dual indexing workflows. Now with the ABIlity to read up to 2 × 250 base pairs.
True walk-away workflow – Use on-board cluster generation and local sample loADIng on the HiSeq 2500 and 1500 for a high-throughput, walk-away workflow. All required reagents for cluster generation, paired end turn, and indexing can be loaded onto the instrument along with your sample template. Then, simply start the run and walk away. Stream runs to BaseSpace for even greater flexibility.
Specifications:
Maximum Output Up to 300 Gb of data per run
Maximum Reads per Run Up to 1.2 Billion (HiSeq 2500 dual flow cell)
Reagent Type Sequencing by Synthesis
Technology Sequencing
System Compatibility HiSeq 1500,HiSeq 2500
"
"Illumina/Nextera Rapid Capture Exome (8 rxn x 3 plex)/FC-140-1083/1 Ea
" Illumina 產(chǎn)品編號: FC-140-1083美 元 價: $2573.00會 員 價: 待定品 牌: Illumina產(chǎn) 地: 美國公 司: Illumina, Inc.產(chǎn)品分類: 分子類>二代測序>DNA文庫制備試劑盒公司分類: Library Preparation Kits "Product Highlights:
The Nextera Rapid Capture Exome and Expanded Exome are all-in-one kits for library preparation and exome enrichment that allow researchers to identify coding variants up to 70% faster than other methods. This optimized exome delivers 45 Mb of expertly selected exonic content and requires as little as 4 Gb of sequencing.
Extend coverage to UTRs and miRNA with Expanded Exome
Nextera Rapid Capture Expanded Exome delivers 62 Mb of genomic content, including exons, untranslated regions (UTRs), and miRNA. This kit features a highly optimized probe set that delivers comprehensive coverage of exonic sequence.
Illumina provides example data sets to demonstrate the high uniformity and accuracy of the Nextera Rapid Capture Exome library prep kit. View the exome sequencing data.
Add on custom content to make Nextera Rapid Capture Exome even more powerful
Researchers can define custom content for this workflow using Nextera Rapid Capture Custom Enrichment. This custom assay allows researchers to rapidly interrogate those portions of the human genome most important to their specific research. Choose from a fully custom design or start from a defined content set, such as Nextera Rapid Capture Exome, and include areas of interest using add-on functionality. Learn More.
Find an up-to-date list of high-throughput automation vendors with robotic systems compatIBLe with this library preparation kit
Specifications:
Assay Time 5 hours total assay time
Hands-On Time 4 hours
Input Quantity 1 ug DNA (compatIBLe with most large DNA genomes)
Mechanism of Action Mechanical fragmentation
Multiplexing Up to 96 dual-index combinations with HT (high-throughput) kit
Variant Class Small Insertions-Deletions (indels)
System Compatibility HiSeq 2000,NextSeq 550,HiSeq 3000,NextSeq 500,HiSeq 2500,HiSeq 4000
Specialized Sample Types Low Input
Technology Sequencing
Species Category Human
Automation CapABIlity Liquid Handling Robots
Method Exome Sequencing
"
"Illumina/Nextera XT DNA Library Preparation Kit (24 samples)/FC-131-1024/1 Ea
" Illumina 產(chǎn)品編號: FC-131-1024美 元 價: $798.00會 員 價: 待定品 牌: Illumina產(chǎn) 地: 美國公 司: Illumina, Inc.產(chǎn)品分類: 分子類>二代測序>DNA文庫制備試劑盒公司分類: Library Preparation Kits "Product Highlights:
Fast Library Prep, Optimized for Small Genomes, PCR Amplicons, and Plasmids
Rapid library preparation – complete library prep in as little as 90 minutes with only 15 minutes of hands-on time
Fast time to results – go from DNA to data in 8 hours with our benchtop sequencers.
Optimized for small genomes, PCR amplicons, and plasmids – one library prep kit for many applications
Innovative sample normalization – eliminates the need for library quantification before sample pooling and sequencing
With Nextera technology, DNA is simultaneously fragmented and tagged with sequencing adapters in a single tube enzymatic reaction. Nextera XT supports ultra-low DNA input of only 1 ng. It enables a wide range of input samples, including small genomes, PCR amplicons greater than 300 bp, plasmids, microbial genomes, concatenated amplicons, and double-stranded CDNA.
Multiplexing of up to 384 samples per Nextera XT library is also available for those projects requiring greater throughput. Plus, the kit includes an innovative bead-based sample normalization that eliminates the need for library quantification prior to pooling and sequencing. Libraries prepared with Nextera XT kits are compatIBLe with all Illumina sequencers.
Find an up-to-date list of high-throughput automation vendors with robotic systems compatIBLe with this library preparation kit
Specifications:
Assay Time 90 minutes
Hands-On Time 15 minutes
Mechanism of Action Enzymatic Fragmentation
Multiplexing Up to 384 uniquely indexed samples may be pooled and sequenced together.
Input Quantity 1 ng DNA
Species Category Drosophila,Any Species,Mammalian,Mouse,Yeast,Zebrafish,Human,Rat,Plant,Nematode,Bacteria
System Compatibility MiSeq,NextSeq 550,NextSeq 500,MiSeq FGx in Research Mode
Method Shotgun Sequencing,Whole-Genome Sequencing,De Novo Sequencing,16S rRNA Sequencing,Amplicon Sequencing,Targeted DNA Sequencing
Variant Class Single Nucleotide Polymorphisms (SNPs),Structural Variants
Specialized Sample Types Low Input,Single Cells
Technology Sequencing
Automation CapABIlity Liquid Handling Robots"
"Illumina/Nextera Index Kit (24 indexes, 96 samples)/FC-121-1011/1 Ea
" Illumina 產(chǎn)品編號: FC-121-1011美 元 價: $260.00會 員 價: 待定品 牌: Illumina產(chǎn) 地: 美國公 司: Illumina, Inc.產(chǎn)品分類: 分子類>二代測序>DNA文庫制備試劑盒公司分類: Library Preparation Kits "Product Highlights:
Nextera DNA Library Preparation Kits provide a fast and easy workflow, enabling sequencing-ready libraries to be generated in less than 90 minutes, with less than 15 minutes of hands-on time. Samples prepared with Nextera kits are compatIBLe with all Illumina sequencers.
With Nextera technology, DNA is simultaneously fragmented and tagged with sequencing adapters in a single step, using standard lab equipment. Ideal for precious samples available in limited quantity, the protocol requires only 50 ng of DNA input.
See a list of automation vendors with robotic systems compatIBLe with this kit
Specifications:
Assay Time 90 minutes
Hands-On Time 15 minutes
Input Quantity 50 ng genomic DNA (compatIBLe with most large DNA genomes)
Mechanism of Action Enzymatic Fragmentation
Multiplexing Up to 96 available indexes
Species Category Human,Other,Mammalian,Mouse,Rat,Plant
Species Details CompatIBLe with most large DNA genomes.
System Compatibility MiSeq,NextSeq 550,HiSeq 3000,MiniSeq,NextSeq 500,HiSeq 2500,HiSeq 4000
Variant Class Single Nucleotide Polymorphisms (SNPs),Structural Variants,Insertions-Deletions (indels)
Method Whole-Genome Sequencing
Technology Sequencing
Automation CapABIlity Liquid Handling Robots
"
"Illumina/HiSeq 3000/4000 SBS Kit (50 cycles)/FC-410-1001/1 Ea
" Illumina 產(chǎn)品編號: FC-410-1001美 元 價: $2270.00會 員 價: 待定品 牌: Illumina產(chǎn) 地: 美國公 司: Illumina, Inc.產(chǎn)品分類: 分子類>二代測序>簇生成和測序試劑公司分類: Cluster Generation & Sequencing Reagents "Product Highlights:
HiSeq 3000/4000 SBS (Sequencing by Synthesis) Kits support a wide range of sequencing applications, making them ideal for high-throughput labs performing various genomic applications. CompatIBLe with the HiSeq 3000 and HiSeq 4000 Sequencing Systems, the new kits leverage patterned flow cell technology for even cluster spacing and uniform feature size, to deliver extremely high cluster densities and significant increases in data output and daily throughput.
The HiSeq 3000/4000 SBS Kits enable up to 1500 Gb (1.5 Tb) of output per dual flow cell run when used with the HiSeq 3000/4000 PE Cluster Kit. This high capacity means that more samples can be sequenced simultaneously at a great depth, generating rich and meaningful data.
Specifications:
Maximum Output Up to 1500 Gb (HiSeq 4000 with 2 flow cells), Up to 750 Gb (HiSeq 3000)
Maximum Reads Up to 5 billion (HiSeq 4000), Up to 2.5 billion (HiSeq 3000)
Reagent Type Sequencing by Synthesis
System Compatibility HiSeq 3000,HiSeq 4000
Technology Sequencing
"
"Illumina/MiSeq Reagent Kit v2 (500-cycles)/MS-102-2003/1 Ea
" Illumina 產(chǎn)品編號: MS-102-2003美 元 價: $1170.00會 員 價: 待定品 牌: Illumina產(chǎn) 地: 美國公 司: Illumina, Inc.產(chǎn)品分類: 分子類>二代測序>簇生成和測序試劑公司分類: Cluster Generation & Sequencing Reagents "Product Highlights:
MiSeq Reagent Kits v2 enable more output to simplify each MiSeq run. MiSeq Reagent Kits v2 retain the same pre-filled, ready-to-use reagent cartridges as the v1 kits, but offer improved chemistry to increase cluster density, decrease cycle time, and improve quality (Q) scores. MiSeq Reagent Kits v2 are also available in micro and nano formats for low output applications.
Get faster cycle times, longer reads and more output from improved chemistry
Dual surface imaging enables twice the number of reads compared to single surface imaging with the v1 kit
Extend your read lengths with the 500-cycle kit
Choose the perfect number of cycles for your application (50, 300, or 500)
When coupled with the MiSeq System upgrade, the MiSeq Reagent Kits v2 allow dual surface imaging to double the amount of readable space per flow cell. MiSeq Regent Kits v2 are available in a 500-cycle format for long read lengths, as well as in the popular 50-cycle and 300-cycle formats.
MiSeq Reagent Kits v2 are available in standard, micro, and nano configurations, enabling alignment to specific project requirements and scalable levels of output.
View product configurations
All MiSeq reagent components are RFID-encoded and interact intelligently with the MiSeq System to validate compatibility with user-defined applications.
A MiSeq Reagent Kit v3 is also available. It offers a 600-cycle format to allow the longest read lengths on any Illumina sequencing system, or a 150-cycle format that enables counting applications.
Specifications:
Maximum Output 8.5 Gb (500-cycle MiSeq Reagent Kit v2), 5.1 Gb (300-cycle MiSeq Reagent Kit v2), 1.2 Gb (300-cycle MiSeq Reagent Micro Kit v2), 0.850 Gb (50-cycle MiSeq Reagent Kit v2), 0.5 Gb (500-cycle MiSeq Reagent Nano Kit v2), 0.3 Gb (300-cycle MiSeq Reagent Nano Kit v2)
Maximum Reads per Run Up to 15 million
Reagent Type Paired-End Sequencing,Cluster Generation,Sequencing by Synthesis
System Compatibility MiSeq,MiSeqDx in Research Mode,MiSeq FGx in Research Mode
Technology Sequencing"
"Illumina/TG HiSeq SBS Kit v4 (50 cycles)/TG-101-4002/1 Ea
" Illumina 產(chǎn)品編號: TG-101-4002美 元 價: $2726.00會 員 價: 待定品 牌: Illumina產(chǎn) 地: 美國公 司: Illumina, Inc.產(chǎn)品分類: 分子類>二代測序>簇生成和測序試劑公司分類: Cluster Generation & Sequencing Reagents "Product Highlights:
HiSeq SBS Kit v4 kits contain ready-to-load reagents for accurately determining the DNA sequence of each cluster on a flow cell using sequencing by synthesis (SBS) technology on enabled HiSeq sequencing systems* run in high output mode.
The HiSeq SBS v4 kits enable up to 1000 gigabases (Gb) of output per 6-day dual flow cell run using the HiSeq PE Cluster Kit v4 cBot. These kits contain sufficient volumes to support dual-indexing applications – no additional SBS reagents are required.
HiSeq v4 chemistry allows all reagents to be loaded onto the instrument before beginning the run. To perform a HiSeq v4 run, you need 1 HiSeq SBS Kit v4. Each kit includes sufficient reagents for sequencing 1 flow cell.
*HiSeq Systems require the latest hardware configuration. Check with your local sales rep regarding system compatibility.
Note: This kit is NOT compatIBLe with the Genome Analyzer.
FlexIBLe Run Configurations
You can choose from single-read or paired-end read runs, with read lengths up to 2×125 bp in high output mode. If longer read lengths are desired, rapid run SBS kits enable up to 2×250 bp.
A Broad Range of Applications
These kits enable a wide variety of applications, from ChIP-Seq to whole-genome sequencing, splice variant detection, and more. They enable researchers, in a single run, to process up to†:
10 genomes
156 exomes
80 whole-transcriptome RNA samples
†Assumes 100 Gb per genome at 2x125 bp, 5 Gb per exome at 2x100 bp with TruSeq Exome or TruSeq Rapid Exome kits, and 50 million reads per transcriptome.
This product is also available as an Illumina Advantage product. Illumina Advantage large-scale sequencing products feature lot-specific shipments and testing, extended shelf life, and advanced change notifications for greater laboratory efficiency.
Specifications:
Maximum Output Up to 1000 Gb per dual flow cell run
Maximum Reads per Run Up to 4 billion
System Compatibility HiSeq 2000,HiSeq 1500,HiSeq 2500
Reagent Type Sequencing by Synthesis
Technology Sequencing
"
"Illumina/Nextera DNA Library Prep Kit (24 samples)/FC-121-1030/1 Ea
" Illumina 產(chǎn)品編號: FC-121-1030美 元 價: $2040.00會 員 價: 待定品 牌: Illumina產(chǎn) 地: 美國公 司: Illumina, Inc.產(chǎn)品分類: 分子類>二代測序>DNA文庫制備試劑盒公司分類: Library Preparation Kits "Product Highlights:
Nextera DNA Library Preparation Kits provide a fast and easy workflow, enabling sequencing-ready libraries to be generated in less than 90 minutes, with less than 15 minutes of hands-on time. Samples prepared with Nextera kits are compatIBLe with all Illumina sequencers.
With Nextera technology, DNA is simultaneously fragmented and tagged with sequencing adapters in a single step, using standard lab equipment. Ideal for precious samples available in limited quantity, the protocol requires only 50 ng of DNA input.
See a list of automation vendors with robotic systems compatIBLe with this kit
Specifications:
Assay Time 90 minutes
Hands-On Time 15 minutes
Input Quantity 50 ng genomic DNA (compatIBLe with most large DNA genomes)
Mechanism of Action Enzymatic Fragmentation
Multiplexing Up to 96 available indexes
Species Category Human,Other,Mammalian,Mouse,Rat,Plant
Species Details CompatIBLe with most large DNA genomes.
System Compatibility MiSeq,NextSeq 550,HiSeq 3000,MiniSeq,NextSeq 500,HiSeq 2500,HiSeq 4000
Variant Class Single Nucleotide Polymorphisms (SNPs),Structural Variants,Insertions-Deletions (indels)
Method Whole-Genome Sequencing
Technology Sequencing
Automation CapABIlity Liquid Handling Robots
"
"Illumina/SureCell™ Whole Transcriptome Analysis 3' Library Prep Kit (6 Cartridges Kit)/20014280/1 Ea
" Illumina 產(chǎn)品編號: 20014280美 元 價: $7200.00會 員 價: 待定品 牌: Illumina產(chǎn) 地: 美國公 司: Illumina, Inc.產(chǎn)品分類: 分子類>二代測序>DNA文庫制備試劑盒公司分類: Library Preparation Kits "Product Highlights:
The Illumina Bio-Rad® SureCell™ Whole Transcriptome Analysis (WTA) 3’ Kit provides a validated process for single-cell RNA sequencing.
Sensitive and unbiased characterization of transcriptional signatures – Highly sensitive and reproducIBLe gene detection in varied individual cells
Comprehensive single-cell RNA sequencing workflow – Fully supported workflow developed in collaboration by technology innovators
Powerful next-generation sequencing integrated with simple data analysis – Proven Illumina sequencing combined with streamlined, user-friendly analysis software
Single cells are individually partitioned into subnanoliter droplets on a disposable cartridge on the one-touch ddSEQ™ Single-Cell Isolator. The cartridge can accommodate multiple samples, and multiple cartridges can be processed in parallel to isolate thousands of cells in a matter of minutes.
Cell lysis and cell barcoding occur inside individual droplets, and single-cell-barcoded RNA-Seq libraries are subsequently prepared using Nextera technology.
Data Analysis
Conduct data analysis via BaseSpace Sequence Hub, the Illumina cloud-based genomics computing environment.
Species Details
This kit has been validated for human and mouse samples. The BaseSpace Single-Cell RNA-Seq App supports analysis of human, mouse, rat, zebrafish, C. elegans, and Drosophila samples.
Specifications:
System Compatibility NextSeq 550,HiSeq 2000,HiSeq 3000,HiSeq 1000,HiSeq 1500,NextSeq 500,HiSeq 2500,NovaSeq 6000,HiSeq 4000
Species Category Human,Mouse
Content Specifications Captures the coding transcriptome (3u0027 enriched), with strand-specific information
Method Whole-Transcriptome Sequencing,mRNA Sequencing
Technology Sequencing
Specialized Sample Types Single Cells
Unbiased, Cell-Size Agnostic RNA-Seq:
Mouse cell lines (A20, NIH3T3) and human cell lines (HEK, BJ) were processed using the SureCell WTA 3′Library Prep Kit. Consistently high numbers of detected genes demonstrates that recovery of transcripts is not limited by cell size.
Confident Single-Cell Transcript Identification:
A. BaseSpace-generated plots of the number of unique molecular identifiers (UMI), i.e. transcripts, assigned to the mouse/mm10 (red) and human/hg19 (blue) genomes for each cell barcode. Unique transcripts mapping to both mouse and human (purple) represent cell doublets. B. Cumulated fraction of unique transcripts assigned to cell barcodes (linear scale). The inflection point (red line) determines the number of barcoded cells detected in the sequencing run.
Confident Cell Population Identification:
A. PCA clustering of 1384 single cells sorted from a 1:1 ratio mixture of HEK 293 and NIH 3T3 cells, sequenced and analyzed with the Single-Cell RNA-Seq BaseSpace App. B. Cell populations cluster based on expression of the human (hg19) RPL13 gene.
Confident Cell Subpopulation Identification:
A. Analysis in the Single-Cell RNA-Seq BaseSpace App using the t-SNE algorithm of a mixture of NIH 3T3 and HEK 293 cells identifies a distinct subpopulation of cells. B. Cells color coded by gene expression of hg19 RPL 13 confirms the identity of the subpopulation as human.
Cell Cycle Analysis of Single Cells by RNA-Seq:
Analysis of cell cycle state using the Single-Cell RNA-Seq BaseSpace App is based on unique transcript counts of genes associated with each phase of the cell cycle, normalized by the total count for each cell. Expression is centered by the median and scaled by the median absolute deviation for each cell cycle."
"Illumina/TruSeq® Exome Kit (8 rxn × 3 plex)/FC-150-1001/1 Ea
" Illumina 產(chǎn)品編號: FC-150-1001美 元 價: $1680.00會 員 價: 待定品 牌: Illumina產(chǎn) 地: 美國公 司: Illumina, Inc.產(chǎn)品分類: 分子類>二代測序>DNA文庫制備試劑盒公司分類: Library Preparation Kits "Product Highlights:
TruSeq Exome Library Prep Kit is a cost-effective library preparation and exome enrichment solution with industry-leADIng accuracy. It offers:
Pre-enrichment library pooling and optimal coverage for low-cost exome sequencing
Mechanical shearing and TruSeq enrichment technology that yield uniform coverage and greater than or equal to 80% on-target sequencing reads
Fully supported workflow solution to simplify exome sequencing
Cost-Effective Exome Sequencing
The TruSeq Exome Library Prep Kit supports 12-plex pre-enrichment library pooling, enabling researchers to maximize sequencing throughput and identify variants in less time by sequencing up to 12 libraries per flow cell lane. The high on-target percentage requires fewer sequencing cycles to reach the optimal level of coverage, while still achieving high coverage uniformity for confident results. It also enables sequencing of more exomes per run, so researchers can maximize their budgets.
To learn more about calculating coverage estimates, see the sequencing coverage calculator.
Proven TruSeq Data Quality
The TruSeq Exome Library Prep Kit delivers ≥ 80% of on-target sequencing reads for efficient, cost-effective exome sequencing. By combining the TruSeq Exome Library Prep Kit with Illumina systems using sequencing by synthesis (SBS) technology, researchers can identify true coding variants and minimize false-positive and false-negative calls.
Convenient, Integrated Workflow Solution
Illumina provides an integrated, fully supported workflow solution that guides researchers from library preparation through analysis. All components of the exome sequencing workflow are designed, optimized, and analytically validated together. Expert Illumina scientists provide a single source of technical and field support for every step in the process.
Find an up-to-date list of high-throughput automation vendors with robotic systems compatIBLe with this library preparation kit
Specifications:
Assay Time 2.5 days
Hands-On Time 6 hours
Input Quantity 100 ng genomic DNA
Content Specifications Captures coding exons. Covers 45 Mb of exonic content (≥98% of RefSeq, CCDS, and Ensembl coding content).
Mechanism of Action Mechanical fragmentation (COVARIS) and exome enrichment with biotinylated capture probes
Multiplexing Up to 12-plex enrichment
System Compatibility NovaSeq 5000,NextSeq 550,HiSeq 3000,NextSeq 500,NovaSeq 6000,HiSeq 4000
Specialized Sample Types FFPE
Technology Sequencing
Species Category Human
Automation CapABIlity Liquid Handling Robots
Method Exome Sequencing"
"Illumina/HiSeq PE Rapid Cluster Kit v2/PE-402-4002/1 Ea
" Illumina 產(chǎn)品編號: PE-402-4002美 元 價: $1430.00會 員 價: 待定品 牌: Illumina產(chǎn) 地: 美國公 司: Illumina, Inc.產(chǎn)品分類: 分子類>二代測序>簇生成和測序試劑公司分類: Cluster Generation & Sequencing Reagents "Product Highlights:
HiSeq Rapid Cluster Kits v2 enable the unique on-board cluster generation process. HiSeq Rapid Cluster Kits v2 are designed to be used in the rapid run mode of HiSeq 2500 and 1500 sequencers.
Optimize your workflow with on-board cluster generation
Improve turnaround time and batching efficiency
Maximize the data quality of your runs
Choose on-board cluster generation to optimize your workflow – On-board cluster generation is a unique high-throughput workflow option enabled by HiSeq Rapid Cluster Kits v2, and is only available in the rapid run mode of the HiSeq 2500 or 1500.
Clonal template clusters are generated from individual template strands directly on the HiSeq 2500 and 1500 instrument using this process. On-board cluster generation minimizes hands-on time and enables a true walkaway solution for high-throughput sequencing needs.
Turn samples around faster – HiSeq Rapid Cluster Kits v2 support the rapid run workflow for the HiSeq 2500 and 1500, and allow you to turn urgent samples around faster.
The lower overall data throughput of rapid run mode also simplifies batching requirements and allows optimal indexing of small genomes and other applications with reduced output needs.
Maximize data quality – HiSeq Rapid Cluster Kits v2 are specifically formulated to work with HiSeq Rapid SBS Kits v2 and provide the highest quality sequencing data available on any high-throughput sequencing system.
HiSeq Rapid Cluster Kits v2 improve cluster density robustness to increase total usable clusters in a given run and decrease cluster grADIents down the lane. This increased robustness and uniformity contribute to higher Q-scores, lower error rates, and higher data quality."
"Illumina/TruSeq Index Plate Fixture & Collar Kit (2 each)/FC-130-1007/1 Ea
" Illumina 產(chǎn)品編號: FC-130-1007美 元 價: $180.00會 員 價: 待定品 牌: Illumina產(chǎn) 地: 美國公 司: Illumina, Inc.產(chǎn)品分類: 分子類>二代測序>DNA文庫制備試劑盒公司分類: Library Preparation Kits "Product Highlights:
TruSeq Custom Amplicon is a fully customizable, amplicon-based assay for targeted resequencing. The assay enables you to focus interrogation on key regions of genomic interest. Up to 1536 amplicons can be sequenced in a single reaction using a simple workflow. This highly targeted approach offers unparalleled efficiency for discovering, validating, and screening genetic variants in areas of research focus.
Requiring as little as 50 ng of input genomic DNA (gDNA), this kit can be used with a wide range of sample types. The ABIlity to multiplex up to 1536 amplicons per reaction allows coverage of up to 650 kb of cumulative sequence. Further, an integrated dual indexing scheme supports up to 96 samples per run, enabling you to fully benefit from desktop sequencer output capABIlities.
This assay provides improved performance in difficult to address GC-rich regions, as well as increased library yield, uniformity, and stABIlity. Additionally, optimized amplification steps enable sample input requirements to drop from 150 ng to 50 ng.
Simplified Probe Design
Design targeted TruSeq Custom Amplicon oligonucleotide probes with DesignStudio, a free, easy-to-use online tool that provides optimized coverage.
Learn more about DesignStudio
Start a project in DesignStudio now (login required)
Simple Data Analysis
Automated data analysis using the BaseSpace TruSeq Amplicon App allows researchers to easily review project data, including variants detected, across multiple runs.
Species Compatibility
TruSeq Custom Amplicon supports human, mouse, rat, and bovine samples. DesignStudio design algorithms are also available for maize, rice, pig, dog, soybean, chicken, and sheep; however, assay performance cannot be guaranteed as the resulting assays have not been tested. In addition, Illumina Concierge services can design custom assays and/or provide assay optimization support for any species of interest.
Inquire about Illumina Concierge services
Find an up-to-date list of high-throughput automation vendors with robotic systems compatIBLe with this library preparation kit
Specifications:
Assay Time 1 day
Hands-On Time 4 hours
Input Quantity 50 ng RNA,50 ng high-quality total RNA,≥ 200 ng FFPE total RNA; Recommended quantity may vary with expression level, target plexity, and sample quality
Content Specifications Choose from 400,000+ pre-designed targeted RNA-Seq assays. Or add content to a fixed panel or previously designed custom panel.
Multiplexing Up to 384 samples per sequencing run
Mechanism of Action Amplification
Variant Class Short Tandem Repeats (STRs),Single Nucleotide Polymorphisms (SNPs),Gene Fusions,Loss of Heterozygosity (LOH),Somatic Variants,Chromosomal Abnormalities,Germline Variants,Structural Variants,Insertions-Deletions (indels)
System Compatibility HiSeq 2000,MiSeq,NextSeq 550,HiSeq 3000,HiSeq 1000,MiSeqDx in Research Mode,MiniSeq,HiSeq 1500,NextSeq 500,MiSeq FGx in Research Mode,HiSeq 2500,HiSeq 4000
Species Category Other,Bovine,Mouse,Human,Rat
Specialized Sample Types FFPE
Technology Sequencing
Automation CapABIlity Liquid Handling Robots
Method Amplicon Sequencing,Custom Sequencing
"
"Illumina/Nextera Rapid Capture Exome (8 rxn x 6 plex)/FC-140-1086/1 Ea
" Illumina 產(chǎn)品編號: FC-140-1086美 元 價: $5145.00會 員 價: 待定品 牌: Illumina產(chǎn) 地: 美國公 司: Illumina, Inc.產(chǎn)品分類: 分子類>二代測序>DNA文庫制備試劑盒公司分類: Library Preparation Kits "Product Highlights:
The Nextera Rapid Capture Exome and Expanded Exome are all-in-one kits for library preparation and exome enrichment that allow researchers to identify coding variants up to 70% faster than other methods. This optimized exome delivers 45 Mb of expertly selected exonic content and requires as little as 4 Gb of sequencing.
Extend coverage to UTRs and miRNA with Expanded Exome
Nextera Rapid Capture Expanded Exome delivers 62 Mb of genomic content, including exons, untranslated regions (UTRs), and miRNA. This kit features a highly optimized probe set that delivers comprehensive coverage of exonic sequence.
Illumina provides example data sets to demonstrate the high uniformity and accuracy of the Nextera Rapid Capture Exome library prep kit. View the exome sequencing data.
Add on custom content to make Nextera Rapid Capture Exome even more powerful
Researchers can define custom content for this workflow using Nextera Rapid Capture Custom Enrichment. This custom assay allows researchers to rapidly interrogate those portions of the human genome most important to their specific research. Choose from a fully custom design or start from a defined content set, such as Nextera Rapid Capture Exome, and include areas of interest using add-on functionality. Learn More.
Find an up-to-date list of high-throughput automation vendors with robotic systems compatIBLe with this library preparation kit
Specifications:
Assay Time 5 hours total assay time
Hands-On Time 4 hours
Input Quantity 1 ug DNA (compatIBLe with most large DNA genomes)
Mechanism of Action Mechanical fragmentation
Multiplexing Up to 96 dual-index combinations with HT (high-throughput) kit
Variant Class Small Insertions-Deletions (indels)
System Compatibility HiSeq 2000,NextSeq 550,HiSeq 3000,NextSeq 500,HiSeq 2500,HiSeq 4000
Specialized Sample Types Low Input
Technology Sequencing
Species Category Human
Automation CapABIlity Liquid Handling Robots
Method Exome Sequencing
"
"Illumina/TruSeq-Methyl Capture EPIC Library Prep Kit (12 samples, 4 indexes)/FC-151-1002/1 Ea
" Illumina 產(chǎn)品編號: FC-151-1002美 元 價: $3300.00會 員 價: 待定品 牌: Illumina產(chǎn) 地: 美國公 司: Illumina, Inc.產(chǎn)品分類: 分子類>二代測序>DNA文庫制備試劑盒公司分類: Library Preparation Kits "Product Highlights:
Targeted Methyl-Seq offers a balanced, cost-effective choice between whole genome bisulfite sequencing and methylation arrays that can support both screening and bioMarker discovery study objectives.1 TruSeq Methyl Capture EPIC Library Prep supports researchers seeking a deeper understanding of the role of methylation in gene regulation:
Comprehensive methylation-site content: Offers significantly higher coverage of emerging epigenetic regions of interest compared to other Methyl-Seq kits currently on the market (See Supporting Data section, Epigenetic Regions Covered).
Maximize discovery power, minimize cost: Efficiently query differentially methylated bases to conserve research dollars.
Convenient kit configuration: Includes bisulfite conversion, library prep, target enrichment, and purification reagents in a single kit for hassle-free ordering.
User-friendly data analysis: Analyze sequence data in the BaseSpace Sequence Hub with methylation apps designed for BIOLOGists.
Specifications:
Assay Time 5 hours total assay time
Hands-On Time 4 hours
Input Quantity 1 ug DNA (compatIBLe with most large DNA genomes)
Mechanism of Action Mechanical fragmentation
Multiplexing Up to 96 dual-index combinations with HT (high-throughput) kit
System Compatibility NextSeq 550,HiSeq 3000,NextSeq 500,HiSeq 2500,HiSeq 4000
Technology Sequencing
Variant Class Differentially Methylated Cytosines
Species Category Human
Method Methylation Sequencing"
"Illumina/Nextera XT Index Kit v2 Set B (96 indexes, 384 samples)/FC-131-2002/1 Ea
" Illumina 產(chǎn)品編號: FC-131-2002美 元 價: $989.00會 員 價: 待定品 牌: Illumina產(chǎn) 地: 美國公 司: Illumina, Inc.產(chǎn)品分類: 分子類>二代測序>DNA文庫制備試劑盒公司分類: Library Preparation Kits "Product Highlights:
Fast Library Prep, Optimized for Small Genomes, PCR Amplicons, and Plasmids
Rapid library preparation – complete library prep in as little as 90 minutes with only 15 minutes of hands-on time
Fast time to results – go from DNA to data in 8 hours with our benchtop sequencers.
Optimized for small genomes, PCR amplicons, and plasmids – one library prep kit for many applications
Innovative sample normalization – eliminates the need for library quantification before sample pooling and sequencing
With Nextera technology, DNA is simultaneously fragmented and tagged with sequencing adapters in a single tube enzymatic reaction. Nextera XT supports ultra-low DNA input of only 1 ng. It enables a wide range of input samples, including small genomes, PCR amplicons greater than 300 bp, plasmids, microbial genomes, concatenated amplicons, and double-stranded CDNA.
Multiplexing of up to 384 samples per Nextera XT library is also available for those projects requiring greater throughput. Plus, the kit includes an innovative bead-based sample normalization that eliminates the need for library quantification prior to pooling and sequencing. Libraries prepared with Nextera XT kits are compatIBLe with all Illumina sequencers.
Find an up-to-date list of high-throughput automation vendors with robotic systems compatIBLe with this library preparation kit
Specifications:
Assay Time 90 minutes
Hands-On Time 15 minutes
Mechanism of Action Enzymatic Fragmentation
Multiplexing Up to 384 uniquely indexed samples may be pooled and sequenced together.
Input Quantity 1 ng DNA
Species Category Drosophila,Any Species,Mammalian,Mouse,Yeast,Zebrafish,Human,Rat,Plant,Nematode,Bacteria
System Compatibility MiSeq,NextSeq 550,NextSeq 500,MiSeq FGx in Research Mode
Method Shotgun Sequencing,Whole-Genome Sequencing,De Novo Sequencing,16S rRNA Sequencing,Amplicon Sequencing,Targeted DNA Sequencing
Variant Class Single Nucleotide Polymorphisms (SNPs),Structural Variants
Specialized Sample Types Low Input,Single Cells
Technology Sequencing
Automation CapABIlity Liquid Handling Robots"
"Illumina/Nextera Rapid Capture Expanded Exome (2 rxn x 12 plex)/FC-140-1004/1 Ea
" Illumina 產(chǎn)品編號: FC-140-1004美 元 價: $5754.00會 員 價: 待定品 牌: Illumina產(chǎn) 地: 美國公 司: Illumina, Inc.產(chǎn)品分類: 分子類>二代測序>DNA文庫制備試劑盒公司分類: Library Preparation Kits "Product Highlights:
The Nextera Rapid Capture Exome and Expanded Exome are all-in-one kits for library preparation and exome enrichment that allow researchers to identify coding variants up to 70% faster than other methods. This optimized exome delivers 45 Mb of expertly selected exonic content and requires as little as 4 Gb of sequencing.
Extend coverage to UTRs and miRNA with Expanded Exome
Nextera Rapid Capture Expanded Exome delivers 62 Mb of genomic content, including exons, untranslated regions (UTRs), and miRNA. This kit features a highly optimized probe set that delivers comprehensive coverage of exonic sequence.
Illumina provides example data sets to demonstrate the high uniformity and accuracy of the Nextera Rapid Capture Exome library prep kit. View the exome sequencing data.
Add on custom content to make Nextera Rapid Capture Exome even more powerful
Researchers can define custom content for this workflow using Nextera Rapid Capture Custom Enrichment. This custom assay allows researchers to rapidly interrogate those portions of the human genome most important to their specific research. Choose from a fully custom design or start from a defined content set, such as Nextera Rapid Capture Exome, and include areas of interest using add-on functionality. Learn More.
Find an up-to-date list of high-throughput automation vendors with robotic systems compatIBLe with this library preparation kit
Specifications:
Assay Time 5 hours total assay time
Hands-On Time 4 hours
Input Quantity 1 ug DNA (compatIBLe with most large DNA genomes)
Mechanism of Action Mechanical fragmentation
Multiplexing Up to 96 dual-index combinations with HT (high-throughput) kit
Variant Class Small Insertions-Deletions (indels)
System Compatibility HiSeq 2000,NextSeq 550,HiSeq 3000,NextSeq 500,HiSeq 2500,HiSeq 4000
Specialized Sample Types Low Input
Technology Sequencing
Species Category Human
Automation CapABIlity Liquid Handling Robots
Method Exome Sequencing
"
"Illumina/Nextera Index Kit (96 indexes, 384 samples)/FC-121-1012/1 Ea
" Illumina 產(chǎn)品編號: FC-121-1012美 元 價: $989.00會 員 價: 待定品 牌: Illumina產(chǎn) 地: 美國公 司: Illumina, Inc.產(chǎn)品分類: 分子類>二代測序>DNA文庫制備試劑盒公司分類: Library Preparation Kits "Product Highlights:
Nextera DNA Library Preparation Kits provide a fast and easy workflow, enabling sequencing-ready libraries to be generated in less than 90 minutes, with less than 15 minutes of hands-on time. Samples prepared with Nextera kits are compatIBLe with all Illumina sequencers.
With Nextera technology, DNA is simultaneously fragmented and tagged with sequencing adapters in a single step, using standard lab equipment. Ideal for precious samples available in limited quantity, the protocol requires only 50 ng of DNA input.
See a list of automation vendors with robotic systems compatIBLe with this kit
Specifications:
Assay Time 90 minutes
Hands-On Time 15 minutes
Input Quantity 50 ng genomic DNA (compatIBLe with most large DNA genomes)
Mechanism of Action Enzymatic Fragmentation
Multiplexing Up to 96 available indexes
Species Category Human,Other,Mammalian,Mouse,Rat,Plant
Species Details CompatIBLe with most large DNA genomes.
System Compatibility MiSeq,NextSeq 550,HiSeq 3000,MiniSeq,NextSeq 500,HiSeq 2500,HiSeq 4000
Variant Class Single Nucleotide Polymorphisms (SNPs),Structural Variants,Insertions-Deletions (indels)
Method Whole-Genome Sequencing
Technology Sequencing
Automation CapABIlity Liquid Handling Robots
"
"Illumina/HiSeq 3000/4000 SR Cluster Kit/GD-410-1001/1 Ea
" Illumina 產(chǎn)品編號: GD-410-1001美 元 價: $3925.00會 員 價: 待定品 牌: Illumina產(chǎn) 地: 美國公 司: Illumina, Inc.產(chǎn)品分類: 分子類>二代測序>簇生成和測序試劑公司分類: Cluster Generation & Sequencing Reagents "Product Highlights:
The HiSeq 3000/4000 SR (Single Read) Cluster Kit provides reagents for cluster generation on the cBot2 cluster amplification system. HiSeq 3000/4000 Cluster Kits used with the HiSeq 3000/4000 SBS Kits generate up to 5 billion clusters per dual flow cell run.
Using innovative patterned flow cell technology the HiSeq 3000/4000 Single Read Cluster Kits greatly increase throughput while optimizing run time and efficiency for a broad range of applications including counting applications. These kits are an ideal solution for high-throughput production-scale laboratories."
"Illumina/Nextera Rapid Capture Expanded Exome (8 rxn x 12 plex)/FC-140-1006/1 Ea
" Illumina 產(chǎn)品編號: FC-140-1006美 元 價: $12852.00會 員 價: 待定品 牌: Illumina產(chǎn) 地: 美國公 司: Illumina, Inc.產(chǎn)品分類: 分子類>二代測序>DNA文庫制備試劑盒公司分類: Library Preparation Kits "Product Highlights:
The Nextera Rapid Capture Exome and Expanded Exome are all-in-one kits for library preparation and exome enrichment that allow researchers to identify coding variants up to 70% faster than other methods. This optimized exome delivers 45 Mb of expertly selected exonic content and requires as little as 4 Gb of sequencing.
Extend coverage to UTRs and miRNA with Expanded Exome
Nextera Rapid Capture Expanded Exome delivers 62 Mb of genomic content, including exons, untranslated regions (UTRs), and miRNA. This kit features a highly optimized probe set that delivers comprehensive coverage of exonic sequence.
Illumina provides example data sets to demonstrate the high uniformity and accuracy of the Nextera Rapid Capture Exome library prep kit. View the exome sequencing data.
Add on custom content to make Nextera Rapid Capture Exome even more powerful
Researchers can define custom content for this workflow using Nextera Rapid Capture Custom Enrichment. This custom assay allows researchers to rapidly interrogate those portions of the human genome most important to their specific research. Choose from a fully custom design or start from a defined content set, such as Nextera Rapid Capture Exome, and include areas of interest using add-on functionality. Learn More.
Find an up-to-date list of high-throughput automation vendors with robotic systems compatIBLe with this library preparation kit
Specifications:
Assay Time 5 hours total assay time
Hands-On Time 4 hours
Input Quantity 1 ug DNA (compatIBLe with most large DNA genomes)
Mechanism of Action Mechanical fragmentation
Multiplexing Up to 96 dual-index combinations with HT (high-throughput) kit
Variant Class Small Insertions-Deletions (indels)
System Compatibility HiSeq 2000,NextSeq 550,HiSeq 3000,NextSeq 500,HiSeq 2500,HiSeq 4000
Specialized Sample Types Low Input
Technology Sequencing
Species Category Human
Automation CapABIlity Liquid Handling Robots
Method Exome Sequencing
"
"Illumina/HiSeq Rapid SBS Kit v2 (500 cycles)/FC-402-4023/1 Ea
" Illumina 產(chǎn)品編號: FC-402-4023美 元 價: $4400.00會 員 價: 待定品 牌: Illumina產(chǎn) 地: 美國公 司: Illumina, Inc.產(chǎn)品分類: 分子類>二代測序>簇生成和測序試劑公司分類: Cluster Generation & Sequencing Reagents "Product Highlights:
HiSeq Rapid v2 SBS Kits enable the longest reads on HiSeq instruments, with reads up to 2x250 bp. The new kits generate up to 300 Gb of data per run. HiSeq Rapid SBS Kits v2 are the ideal choice for sequencing on HiSeq systems. These kits:
Maximize the data quality of your runs
Improve turnaround time and batching efficiency
Provide multiple kit configurations
Allow you to set up once and walk away
Maximize data quality – HiSeq Rapid SBS Kits v2 are formulated to provide the highest data quality with reads up to 2x250 bp. Building on the well-established SBS chemistry, HiSeq Rapid SBS Kits integrate innovative features that increase Q-scores, decrease error rates and deliver unparalleled data quality.
Turn samples faster – HiSeq Rapid SBS Kits v2 support the rapid run workflow for the HiSeq 2500 and 1500, and allow you to turn urgent samples around fast. The lower overall data throughput of rapid run mode also simplifies batching requirements and allows optimal indexing of small genomes and other applications with reduced output needs.
Kit configurations – HiSeq Rapid SBS Kits v2 are available in three configurations: 500 cycle, 200 cycle, and 50 cycle. All HiSeq Rapid SBS v2 Kits provide sufficient reagents to support single or dual indexing workflows. Now with the ABIlity to read up to 2 × 250 base pairs.
True walk-away workflow – Use on-board cluster generation and local sample loADIng on the HiSeq 2500 and 1500 for a high-throughput, walk-away workflow. All required reagents for cluster generation, paired end turn, and indexing can be loaded onto the instrument along with your sample template. Then, simply start the run and walk away. Stream runs to BaseSpace for even greater flexibility.
Specifications:
Maximum Output Up to 300 Gb of data per run
Maximum Reads per Run Up to 1.2 Billion (HiSeq 2500 dual flow cell)
Reagent Type Sequencing by Synthesis
Technology Sequencing
System Compatibility HiSeq 1500,HiSeq 2500
"
"Illumina/TruSeq Custom Amplicon Index Kit (96 indexes, 384 samples)/FC-130-1003/1 Ea
" Illumina 產(chǎn)品編號: FC-130-1003美 元 價: $970.00會 員 價: 待定品 牌: Illumina產(chǎn) 地: 美國公 司: Illumina, Inc.產(chǎn)品分類: 分子類>二代測序>DNA文庫制備試劑盒公司分類: Library Preparation Kits "Product Highlights:
The TruSeq Custom Amplicon Low Input Library Prep Kit is a scalable amplicon sequencing solution that delivers sensitive and specific results from both low-input and formalin-fixed, paraffin-embedded (FFPE) DNA samples. It offers:
Accurate variant detection from as low as 10 ng of input genomic DNA (gDNA) and challenging FFPE samples
Fully supported, optimized workflow solution including simple data analysis
Automation-friendly workflow that can be completed in 6 hours, with only 3 hours of hands-on time
Low DNA Input and FFPE Compatibility
The TruSeq Custom Amplicon Low Input Library Prep Kit is a fully customizable, amplicon-based assay for targeted resequencing starting from as low as 10 ng of genomic DNA (gDNA). This scalable assay allows researchers to capture multiple targets of interest simultaneously and sequence up to 1536 amplicons in a single pool, using a single reaction. This library prep kit offers the flexibility to accommodate FFPE samples, such as preserved tumor tissue.
Confident Assay Design
Design targeted TruSeq Custom Amplicon oligonucleotide probes with DesignStudio, a free, easy-to-use online tool that provides optimized coverage.
Learn more about DesignStudio
Start a project in DesignStudio now (login required)
Assess FFPE Sample Quality before Sequencing
The TruSeq FFPE DNA Library Prep QC Kit uses a simple qPCR reaction to determine DNA quality and provide guidance on sequencing parameters. This step ensures that only samples that will achieve the necessary sequencing metrics are prepared, conserving resources that might be used on potentially low-quality, unrecoverable samples. The results of the QC step determine the recommended amount of input DNA. The TruSeq FFPE DNA Library Prep QC Kit can be bundled with the TruSeq Custom Amplicon Low Input Library Prep Kit to maximize lab budgets.
For FFPE applications, we suggest designing your project with 150 bp or 175 bp amplicons since FFPE DNA is highly degraded. TruSeq Custom Amplicon Low Input cannot be used with applications requiring 425 bp amplicons.
Species Compatibility
The TruSeq Custom Amplicon Low Input Library Prep Kit supports human, mouse, rat, and bovine samples. DesignStudio design algorithms are also available for maize, rice, pig, dog, soybean, chicken, and sheep; however, assay performance cannot be guaranteed as the resulting assays have not been tested. In addition, Illumina Concierge services can design custom assays and/or provide assay optimization support for any species of interest.
Inquire about Illumina Concierge services
Find an up-to-date list of high-throughput automation vendors with robotic systems compatIBLe with this library preparation kit
Specifications:
Assay Time 1 day
Hands-On Time 4 hours
Input Quantity 50 ng RNA,50 ng high-quality total RNA,≥ 200 ng FFPE total RNA; Recommended quantity may vary with expression level, target plexity, and sample quality
Content Specifications Choose from 400,000+ pre-designed targeted RNA-Seq assays. Or add content to a fixed panel or previously designed custom panel.
Multiplexing Up to 384 samples per sequencing run
Mechanism of Action Amplification
TruSeq Custom Amplicon Library Prep Protocol:
The TruSeq Custom Amplicon assay is a simple and streamlined method for capturing and amplifying targeted regions of interest.
Seamless Amplicon Sequencing Workflow:
The TruSeq Custom Amplicon Low Input Library Prep Kit is part of an integrated, fully supported workflow for amplicon sequencing that guides researchers from design through data analysis. Illumina technical and field specialists help ensure rapid resolution and minimize potential laboratory downtime.
Robust Variant Detection at Low DNA Input:
The TruSeq Custom Amplicon Low Input Library Prep Kit demonstrates high concordance between expected and observed variant frequencies for 10 ng high-quality FFPE DNA. Reference DNA samples were prepared following the TruSeq Custom Amplicon Low Input workflow with the TruSeq Amplicon - Cancer Panel primer pool, and sequenced on the MiSeq System in replicates of 4. Variants were called using MiSeq Reporter Software. R2 values are shown."
"Illumina/NextSeq 500/550 High Output v2 kit (150 cycles)/FC-404-2002/1 Ea
" Illumina 產(chǎn)品編號: FC-404-2002美 元 價: $2780.00會 員 價: 待定品 牌: Illumina產(chǎn) 地: 美國公 司: Illumina, Inc.產(chǎn)品分類: 分子類>二代測序>簇生成和測序試劑公司分類: Cluster Generation & Sequencing Reagents "Product Highlights:
NextSeq 500/550 v2 sequencing reagent kits bring the power of a high-throughput sequencing system to the desktop, now with improved data quality and the highest yield of error-free reads. These kits offer:
Robust base calling and improved signal-to-noise ratio
Multiple options for both sequencing output and read length
Simplified reagent cartridge configurations, with improved workflow and cartridge loADIng
Intuitive labeling and RFID-encoded reagents
Optimized chemistry with the latest in sequencing by synthesis (SBS) and bridge-amplification cluster generation
The kits deliver powerful sequencing chemistries with as little as 10 minutes of hands-on time. Intuitive labeling and RFID-encoded reagents ensure compatibility with user-defined run configurations.
Ready-to-use cartridges redefine ease-of-use
Pre-configured reagent kits for the NextSeq Series Systems provide all the components needed for sequencing on the platform in 3 ready-to-use cartridges (reagent, flow cell, and buffer). The kits offer simplified cartridge loADIng with the bleach and dual-indexing primers already in the cartridge.
Simply load user-prepared library pools directly into the NextSeq reagent cartridge. The system automatically performs all steps necessary for template amplification and sequencing without user intervention.
Specifications:
Maximum Output 120 Gb (300-cycle high output kit), 60 Gb (150-cycle high output kit), 39 Gb (300-cycle mid output kit), 30 Gb (75-cycle high output kit), 19.5 Gb (150-cycle mid output kit)
Maximum Reads per Run 400 million clusters (high output kits), 130 million clusters (mid output kits)
Reagent Type Paired-End Sequencing,Cluster Generation,Sequencing by Synthesis,Single-Read Sequencing
System Compatibility NextSeq 550,NextSeq 500
Technology Sequencing"
"Illumina/HiSeq X Five Reagent Kit v2.5/FC-502-2501/1 Ea
" Illumina 產(chǎn)品編號: FC-502-2501美 元 價: $19125.00會 員 價: 待定品 牌: Illumina產(chǎn) 地: 美國公 司: Illumina, Inc.產(chǎn)品分類: 分子類>二代測序>簇生成和測序試劑公司分類: Cluster Generation & Sequencing Reagents "Product Highlights:
HiSeq X Reagent Kits support high coverage whole-genome sequencing (WGS) with the HiSeq X Series of sequencing systems. By leveraging patterned flow cells, these kits provide increased cluster density to enable significant increases in data output and daily throughput. HiSeq X Reagent Kits support industry-leADIng library preparation options while offering superior data quality and coverage.
HiSeq X Reagent Kits support the TruSeq DNA PCR-Free Library Preparation Kit, for industry-best coverage of challenging genomic regions, and the TruSeq Nano DNA Library Preparation Kit, for efficient sequencing of samples with limited available DNA. Together, the reagent kits and library preparation options deliver exceptional genome coverage, enabling highly accurate and comprehensive variant calling for WGS on the HiSeq X Ten and the HiSeq X Five Systems. The HiSeq X Reagent Kits:
Deliver ultra-high data output
Provide ultra-high daily throughput
Enable sequencing up to 16 genomes per run
Are available in single and multipack configurations
Are compatIBLe with TruSeq DNA PCR-Free and TruSeq Nano DNA LibraryPreparation Kits
HiSeq X Reagent Kits are only compatIBLe with the HiSeq X Series of sequencing systems. HiSeq X Ten Reagent Kits are only available for purchase by HiSeq X Ten users and the HiSeq X Five Reagent Kits are only available for purchase by HiSeq X Five users. Reagents are also available in a multipack configuration to support bulk purchasing with significant reductions in packaging materials.
Latest technology innovation powers population-scale sequencing
HiSeq X Reagent Kits leverage the newest format in Illumina flow cell technology to achieve ultra-high-throughput WGS. Patterned flow cells contain billions of nanowell substrates at fixed locations across both surfaces of the flow cell. The structured organization (see below) provides even spacing of sequencing clusters to deliver significant increases in sequencing reads and total output of the system.
Specifications:
Maximum Output Up to 1800 Gb (1 HiSeq X System with dual flow cells)
Maximum Reads per Run Up to 6 billion
Reagent Type Paired-End Sequencing,Cluster Generation
System Compatibility HiSeq X Ten,HiSeq X Five
Technology Sequencing
"
"Illumina/TruSeq Stranded Total RNA Library Prep Kit with Ribo-Zero Gold Set B (48 samples, 12 indexes)/RS-122-2302/1 Ea
" Illumina 產(chǎn)品編號: RS-122-2302美 元 價: $5630.00會 員 價: 待定品 牌: Illumina產(chǎn) 地: 美國公 司: Illumina, Inc.產(chǎn)品分類: 分子類>二代測序>DNA文庫制備試劑盒公司分類: Library Preparation Kits "Product Highlights:
The TruSeq Stranded Total Library Preparation kit provides a clear view of the transcriptome with a streamlined, cost-efficient, and scalable solution for total RNA analysis with sequencing.
Whole-Transcriptome Analysis with Precise Measurement of Strand Orientation
CompatIBLe with a wide range of samples, including low-quality and FFPE, TruSeq Stranded Total RNA kits couple all of the benefits of TruSeq RNA preparation kits with Ribo-Zero ribosomal RNA reduction chemistry, providing analysis of coding and multiple forms of noncoding RNA with precise measurement of strand orientation, uniform coverage, and high-confidence discovery of features such as alternative transcripts, gene fusions, and allele-specific expression.
Find an up-to-date list of high-throughput automation vendors with robotic systems compatIBLe with this library preparation kit
FlexIBLe Solutions for a Range of Study Designs
The TruSeq Stranded Total RNA Library Prep kit is available in multiple versions to fit specific study design needs:
TruSeq Stranded Total RNA with Ribo-Zero Human/Mouse/Rat removes cytoplasmic rRNA.
TruSeq Stranded Total RNA with Ribo-Zero Gold removes both cytoplasmic and mitochondrial rRNA.
The total RNA kits are also compatIBLe with the new unique dual index kits, TruSeq RNA Unique Dual Indexes, which allows multiplexing of up to 96 samples.
Species Compatibility
The TruSeq Stranded Total Library Preparation kit is designed for human, mouse and rat sequences, but may be applicable to a variety of eukaryotic species.*
*For information on a particular species of interest, contact Illumina Technical Support.
Specifications:
Input Quantity 0.1 – 1 ug high-quality total RNA. Lower-quality samples may require further optimization.
Content Specifications Captures coding RNA plus multiple forms of non-coding RNA
Mechanism of Action Bead-based rRNA depletion, CDNA synthesis, and PCR
Multiplexing Low-throughput kits: Pool up to 12 samples. Or pool up to 24 samples with sets A and B together,High-throughput kits: Prepare 96 uniquely indexed samples.
System Compatibility NovaSeq 5000,Genome Analyzer IIx,HiSeq 2000,NextSeq 550,HiSeq 3000,HiSeq 1000,HiSeq 1500,NextSeq 500,HiSeq 2500,NovaSeq 6000,HiSeq 4000
Variant Class Single Nucleotide Polymorphisms (SNPs),Gene Fusions,Novel Transcripts,Transcript Variants
Specialized Sample Types FFPE
Method Whole-Transcriptome Sequencing
Species Category Mouse,Human,Rat
Technology Sequencing
Automation CapABIlity Liquid Handling Robots"
"Illumina/Nextera Rapid Capture Exome (8 rxn x 9 plex)/FC-140-1089/1 Ea
" Illumina 產(chǎn)品編號: FC-140-1089美 元 價: $7712.00會 員 價: 待定品 牌: Illumina產(chǎn) 地: 美國公 司: Illumina, Inc.產(chǎn)品分類: 分子類>二代測序>DNA文庫制備試劑盒公司分類: Library Preparation Kits "Product Highlights:
The Nextera Rapid Capture Exome and Expanded Exome are all-in-one kits for library preparation and exome enrichment that allow researchers to identify coding variants up to 70% faster than other methods. This optimized exome delivers 45 Mb of expertly selected exonic content and requires as little as 4 Gb of sequencing.
Extend coverage to UTRs and miRNA with Expanded Exome
Nextera Rapid Capture Expanded Exome delivers 62 Mb of genomic content, including exons, untranslated regions (UTRs), and miRNA. This kit features a highly optimized probe set that delivers comprehensive coverage of exonic sequence.
Illumina provides example data sets to demonstrate the high uniformity and accuracy of the Nextera Rapid Capture Exome library prep kit. View the exome sequencing data.
Add on custom content to make Nextera Rapid Capture Exome even more powerful
Researchers can define custom content for this workflow using Nextera Rapid Capture Custom Enrichment. This custom assay allows researchers to rapidly interrogate those portions of the human genome most important to their specific research. Choose from a fully custom design or start from a defined content set, such as Nextera Rapid Capture Exome, and include areas of interest using add-on functionality. Learn More.
Find an up-to-date list of high-throughput automation vendors with robotic systems compatIBLe with this library preparation kit
Specifications:
Assay Time 5 hours total assay time
Hands-On Time 4 hours
Input Quantity 1 ug DNA (compatIBLe with most large DNA genomes)
Mechanism of Action Mechanical fragmentation
Multiplexing Up to 96 dual-index combinations with HT (high-throughput) kit
Variant Class Small Insertions-Deletions (indels)
System Compatibility HiSeq 2000,NextSeq 550,HiSeq 3000,NextSeq 500,HiSeq 2500,HiSeq 4000
Specialized Sample Types Low Input
Technology Sequencing
Species Category Human
Automation CapABIlity Liquid Handling Robots
Method Exome Sequencing
"
"Illumina/HiSeq® 3000/4000 PE Cluster Kit/PE-410-1001/1 Ea
" Illumina 產(chǎn)品編號: PE-410-1001美 元 價: $6060.00會 員 價: 待定品 牌: Illumina產(chǎn) 地: 美國公 司: Illumina, Inc.產(chǎn)品分類: 分子類>二代測序>簇生成和測序試劑公司分類: Cluster Generation & Sequencing Reagents "Product Highlights:
The HiSeq 3000/4000 PE (Paired-End) Cluster Kit provides reagents for cluster generation on the cBot cluster amplification system. HiSeq 3000/4000 Cluster Kits, together with HiSeq 3000/4000 SBS Kits, can generate up to 1500 Gb (1.5 Tb) of output per dual flow cell run.
The HiSeq 3000/4000 PE Cluster Kit uses innovative patterned flow cell technology to achieve greater capacity on the HiSeq 3000/HiSeq 4000 Systems. These kits increase data output and daily throughput significantly for a broad range of applications, making them the ideal solution for high-throughput production-scale laboratories."
"Illumina/TruSeq Stranded Total RNA Kit with Ribo-Zero Plant, High Throughput (96 samples, 96 indexes)/RS-122-2403/1 Ea
" Illumina 產(chǎn)品編號: RS-122-2403美 元 價: $10280.00會 員 價: 待定品 牌: Illumina產(chǎn) 地: 美國公 司: Illumina, Inc.產(chǎn)品分類: 分子類>二代測序>DNA文庫制備試劑盒公司分類: Library Preparation Kits "Product Highlights:
High-Quality Whole-Transcriptome Analysis with Precise Strand Information
RNA-Seq technology provides uniform coverage, precise measurement of strand orientation and high-confidence discovery of features such as alternative transcripts, antisense expression and allele-specific expression across both coding and multiple forms of noncoding RNA. The TruSeq Stranded Total RNA with Ribo-Zero Plant Kit couples the benefits of TruSeq RNA library preparation with Ribo-Zero ribosomal RNA reduction chemistry, providing a robust and scalable solution for whole-transcriptome analysis.
Find an up-to-date list of high-throughput automation vendors with robotic systems compatIBLe with this library preparation kit
Efficient Ribosomal RNA Reduction Across a Range of Plant Species, Study Designs
The TruSeq Stranded Total RNA with Ribo-Zero Plant Kit enables rapid and specific removal of cytoplasmic, mitochondrial and chloroplast ribosomal RNA from leaf, seed, and root tissue. The kit has been validated for use in multiple plant species, including ArABIdopsis thaliana, rice, and maize, and will provide efficient rRNA removal in a broad range of additional species.*
*For information on a particular species of interest, contact Illumina Technical Support.
Specifications:
Assay Time ~6.5 hours
Hands-On Time ~3.5 hours
Input Quantity 10 ng high-quality genomic DNA; 10 – 100 ng FFPE DNA (depending on QC results)
Mechanism of Action Probe hybridization, extension-ligation, and PCR
Multiplexing 1–96
Content Specifications Design custom probes to sequence genomic regions of interest. Content range: 4 – 650 kb
Variant Class Short Tandem Repeats (STRs),Single Nucleotide Polymorphisms (SNPs),Gene Fusions,Loss of Heterozygosity (LOH),Somatic Variants,Chromosomal Abnormalities,Germline Variants,Structural Variants,Insertions-Deletions (indels)
System Compatibility HiSeq 2000,MiSeq,NextSeq 550,HiSeq 3000,HiSeq 1000,MiSeqDx in Research Mode,MiniSeq,HiSeq 1500,NextSeq 500,MiSeq FGx in Research Mode,HiSeq 2500,HiSeq 4000
Species Category Other,Bovine,Mouse,Human,Rat
Specialized Sample Types FFPE,Low Input
Technology Sequencing
Automation CapABIlity Liquid Handling Robots
Method Amplicon Sequencing,Custom Sequencing
"
"Illumina/TruSeq® Rapid Exome Kit (8 rxn × 9 plex)/FC-144-1003/1 Ea
" Illumina 產(chǎn)品編號: FC-144-1003美 元 價: $7200.00會 員 價: 待定品 牌: Illumina產(chǎn) 地: 美國公 司: Illumina, Inc.產(chǎn)品分類: 分子類>二代測序>DNA文庫制備試劑盒公司分類: Library Preparation Kits "Product Highlights:
The TruSeq Rapid Exome Library Prep Kit delivers a simple, efficient method for high-confidence calling of exonic variants. The fast library preparation and exome enrichment workflow deliver libraries in 1 day with no need for additional equipment, giving labs the flexibility to plan projects according to sample volume. This kit offers:
Enhanced transposome chemistry results in reduced bias, providing consistent library preparation and exome enrichment.
Rapid, automation-friendly workflow completes in 1 day with only 3 hours of hands-on time.
High coverage uniformity across exonic regions and on-target %
Proven TruSeq Data Quality
The TruSeq Rapid Exome Library Prep Kit delivers an average of 75% of on-target sequencing reads. This high on-target percentage requires fewer sequencing cycles to reach desired coverage levels, but still achieves uniform coverage for high-confidence results.
To learn more about calculating coverage estimates, see the sequencing coverage calculator.
Find an up-to-date list of high-throughput automation vendors with robotic systems compatIBLe with this library preparation kit
Specifications:
Assay Time 1 day
Hands-On Time 3 hours
Input Quantity 50 ng genomic DNA
Content Specifications Captures coding exons. Covers 45 Mb of exonic content (≥98% of RefSeq, CCDS, and Ensembl coding content).
Mechanism of Action Transposase-based fragmentation and exome enrichment with biotinylated capture probes
Multiplexing Up to 12-plex enrichment
Technology Sequencing
Species Category Human
Automation CapABIlity Liquid Handling Robots
System Compatibility NextSeq 500,NovaSeq 6000,HiSeq 4000
Method Exome Sequencing
"
"Illumina/20-pack MiSeq Reagent Kit v2 (50-cycles)/MS-102-2021/1 Ea
" Illumina 產(chǎn)品編號: MS-102-2021美 元 價: $15450.00會 員 價: 待定品 牌: Illumina產(chǎn) 地: 美國公 司: Illumina, Inc.產(chǎn)品分類: 分子類>二代測序>簇生成和測序試劑公司分類: Cluster Generation & Sequencing Reagents "Product Highlights:
MiSeq Reagent Kits v2 enable more output to simplify each MiSeq run. MiSeq Reagent Kits v2 retain the same pre-filled, ready-to-use reagent cartridges as the v1 kits, but offer improved chemistry to increase cluster density, decrease cycle time, and improve quality (Q) scores. MiSeq Reagent Kits v2 are also available in micro and nano formats for low output applications.
Get faster cycle times, longer reads and more output from improved chemistry
Dual surface imaging enables twice the number of reads compared to single surface imaging with the v1 kit
Extend your read lengths with the 500-cycle kit
Choose the perfect number of cycles for your application (50, 300, or 500)
When coupled with the MiSeq System upgrade, the MiSeq Reagent Kits v2 allow dual surface imaging to double the amount of readable space per flow cell. MiSeq Regent Kits v2 are available in a 500-cycle format for long read lengths, as well as in the popular 50-cycle and 300-cycle formats.
MiSeq Reagent Kits v2 are available in standard, micro, and nano configurations, enabling alignment to specific project requirements and scalable levels of output.
View product configurations
All MiSeq reagent components are RFID-encoded and interact intelligently with the MiSeq System to validate compatibility with user-defined applications.
A MiSeq Reagent Kit v3 is also available. It offers a 600-cycle format to allow the longest read lengths on any Illumina sequencing system, or a 150-cycle format that enables counting applications.
Specifications:
Maximum Output 8.5 Gb (500-cycle MiSeq Reagent Kit v2), 5.1 Gb (300-cycle MiSeq Reagent Kit v2), 1.2 Gb (300-cycle MiSeq Reagent Micro Kit v2), 0.850 Gb (50-cycle MiSeq Reagent Kit v2), 0.5 Gb (500-cycle MiSeq Reagent Nano Kit v2), 0.3 Gb (300-cycle MiSeq Reagent Nano Kit v2)
Maximum Reads per Run Up to 15 million
Reagent Type Paired-End Sequencing,Cluster Generation,Sequencing by Synthesis
System Compatibility MiSeq,MiSeqDx in Research Mode,MiSeq FGx in Research Mode
Technology Sequencing"
"Illumina/NextSeq 500/550 Mid Output v2 kit (150 cycles)/FC-404-2001/1 Ea
" Illumina 產(chǎn)品編號: FC-404-2001美 元 價: $1060.00會 員 價: 待定品 牌: Illumina產(chǎn) 地: 美國公 司: Illumina, Inc.產(chǎn)品分類: 分子類>二代測序>簇生成和測序試劑公司分類: Cluster Generation & Sequencing Reagents "Product Highlights:
NextSeq 500/550 v2 sequencing reagent kits bring the power of a high-throughput sequencing system to the desktop, now with improved data quality and the highest yield of error-free reads. These kits offer:
Robust base calling and improved signal-to-noise ratio
Multiple options for both sequencing output and read length
Simplified reagent cartridge configurations, with improved workflow and cartridge loADIng
Intuitive labeling and RFID-encoded reagents
Optimized chemistry with the latest in sequencing by synthesis (SBS) and bridge-amplification cluster generation
The kits deliver powerful sequencing chemistries with as little as 10 minutes of hands-on time. Intuitive labeling and RFID-encoded reagents ensure compatibility with user-defined run configurations.
Ready-to-use cartridges redefine ease-of-use
Pre-configured reagent kits for the NextSeq Series Systems provide all the components needed for sequencing on the platform in 3 ready-to-use cartridges (reagent, flow cell, and buffer). The kits offer simplified cartridge loADIng with the bleach and dual-indexing primers already in the cartridge.
Simply load user-prepared library pools directly into the NextSeq reagent cartridge. The system automatically performs all steps necessary for template amplification and sequencing without user intervention.
Specifications:
Maximum Output 120 Gb (300-cycle high output kit), 60 Gb (150-cycle high output kit), 39 Gb (300-cycle mid output kit), 30 Gb (75-cycle high output kit), 19.5 Gb (150-cycle mid output kit)
Maximum Reads per Run 400 million clusters (high output kits), 130 million clusters (mid output kits)
Reagent Type Paired-End Sequencing,Cluster Generation,Sequencing by Synthesis,Single-Read Sequencing
System Compatibility NextSeq 550,NextSeq 500
Technology Sequencing"
"Illumina/MiSeq Reagent Kit v2 (300-cycles)/MS-102-2002/1 Ea
" Illumina 產(chǎn)品編號: MS-102-2002美 元 價: $1045.00會 員 價: 待定品 牌: Illumina產(chǎn) 地: 美國公 司: Illumina, Inc.產(chǎn)品分類: 分子類>二代測序>簇生成和測序試劑公司分類: Cluster Generation & Sequencing Reagents "Product Highlights:
MiSeq Reagent Kits v2 enable more output to simplify each MiSeq run. MiSeq Reagent Kits v2 retain the same pre-filled, ready-to-use reagent cartridges as the v1 kits, but offer improved chemistry to increase cluster density, decrease cycle time, and improve quality (Q) scores. MiSeq Reagent Kits v2 are also available in micro and nano formats for low output applications.
Get faster cycle times, longer reads and more output from improved chemistry
Dual surface imaging enables twice the number of reads compared to single surface imaging with the v1 kit
Extend your read lengths with the 500-cycle kit
Choose the perfect number of cycles for your application (50, 300, or 500)
When coupled with the MiSeq System upgrade, the MiSeq Reagent Kits v2 allow dual surface imaging to double the amount of readable space per flow cell. MiSeq Regent Kits v2 are available in a 500-cycle format for long read lengths, as well as in the popular 50-cycle and 300-cycle formats.
MiSeq Reagent Kits v2 are available in standard, micro, and nano configurations, enabling alignment to specific project requirements and scalable levels of output.
View product configurations
All MiSeq reagent components are RFID-encoded and interact intelligently with the MiSeq System to validate compatibility with user-defined applications.
A MiSeq Reagent Kit v3 is also available. It offers a 600-cycle format to allow the longest read lengths on any Illumina sequencing system, or a 150-cycle format that enables counting applications.
Specifications:
Maximum Output 8.5 Gb (500-cycle MiSeq Reagent Kit v2), 5.1 Gb (300-cycle MiSeq Reagent Kit v2), 1.2 Gb (300-cycle MiSeq Reagent Micro Kit v2), 0.850 Gb (50-cycle MiSeq Reagent Kit v2), 0.5 Gb (500-cycle MiSeq Reagent Nano Kit v2), 0.3 Gb (300-cycle MiSeq Reagent Nano Kit v2)
Maximum Reads per Run Up to 15 million
Reagent Type Paired-End Sequencing,Cluster Generation,Sequencing by Synthesis
System Compatibility MiSeq,MiSeqDx in Research Mode,MiSeq FGx in Research Mode
Technology Sequencing
"
"Illumina/Nextera Rapid Capture Exome (2 rxn x 12 plex)/FC-140-1001/1 Ea
" Illumina 產(chǎn)品編號: FC-140-1001美 元 價: $5114.00會 員 價: 待定品 牌: Illumina產(chǎn) 地: 美國公 司: Illumina, Inc.產(chǎn)品分類: 分子類>二代測序>DNA文庫制備試劑盒公司分類: Library Preparation Kits "Product Highlights:
The Nextera Rapid Capture Exome and Expanded Exome are all-in-one kits for library preparation and exome enrichment that allow researchers to identify coding variants up to 70% faster than other methods. This optimized exome delivers 45 Mb of expertly selected exonic content and requires as little as 4 Gb of sequencing.
Extend coverage to UTRs and miRNA with Expanded Exome
Nextera Rapid Capture Expanded Exome delivers 62 Mb of genomic content, including exons, untranslated regions (UTRs), and miRNA. This kit features a highly optimized probe set that delivers comprehensive coverage of exonic sequence.
Illumina provides example data sets to demonstrate the high uniformity and accuracy of the Nextera Rapid Capture Exome library prep kit. View the exome sequencing data.
Add on custom content to make Nextera Rapid Capture Exome even more powerful
Researchers can define custom content for this workflow using Nextera Rapid Capture Custom Enrichment. This custom assay allows researchers to rapidly interrogate those portions of the human genome most important to their specific research. Choose from a fully custom design or start from a defined content set, such as Nextera Rapid Capture Exome, and include areas of interest using add-on functionality. Learn More.
Find an up-to-date list of high-throughput automation vendors with robotic systems compatIBLe with this library preparation kit
Specifications:
Assay Time 5 hours total assay time
Hands-On Time 4 hours
Input Quantity 1 ug DNA (compatIBLe with most large DNA genomes)
Mechanism of Action Mechanical fragmentation
Multiplexing Up to 96 dual-index combinations with HT (high-throughput) kit
Variant Class Small Insertions-Deletions (indels)
System Compatibility HiSeq 2000,NextSeq 550,HiSeq 3000,NextSeq 500,HiSeq 2500,HiSeq 4000
Specialized Sample Types Low Input
Technology Sequencing
Species Category Human
Automation CapABIlity Liquid Handling Robots
Method Exome Sequencing
"
"Illumina/Nextera DNA Flex Library Prep (24 Samples)/20018704/1 Ea
" Illumina 產(chǎn)品編號: 20018704美 元 價: $1008.00會 員 價: 待定品 牌: Illumina產(chǎn) 地: 美國公 司: Illumina, Inc.產(chǎn)品分類: 分子類>二代測序>DNA文庫制備試劑盒公司分類: Library Preparation Kits "Product Highlights:
The Nextera DNA Flex Library Prep Kit offers flexibility for many whole-genome sequencing applications.
Fastest Illumina library prep workflow, with ~3.5 hours total time
Flexibility to accommodate variations in sample type, DNA input amount, and application
Optimized library prep performance, generating reliable results
Save Time and Resources
The Nextera DNA Flex Library Prep Kit uses a fast, user-friendly workflow. On-bead tagmentation chemistry reduces total library prep time to ~3.5 hours, from DNA extraction to library normalization.
Simplify Lab Operations
The Nextera DNA Flex workflow supports a broad DNA input range (1–500 ng), multiple sample types, and both small and large genomes. The workflow includes DNA extraction from blood, saliva, or dried blood spots*or bacterial colonies*. Gain the flexibility to sequence human or other large, complex genomes as well as amplicons or microbial species, all with a single kit.
Obtain Reliable Results
While accommodating various study requirements, the Nextera DNA Flex workflow delivers consistent insert sizes, uniform coverage, and optimized performance, regardless of DNA input amount or genome size. The bead-based technology minimizes bias and opportunities for error, resulting in highly reproducIBLe sequencing data.
*Demonstrated protocols available.
Specifications:
Assay Time ~3.5 hours total assay time
Hands-On Time 1-1.5 hours
Input Quantity Small Genomes: 1-500 ng DNA; Large Genomes: 100-500 ng
Content Specifications Human Whole Genome, Small Whole Genome, Large Whole Genome
Mechanism of Action Bead-linked transposome
Multiplexing Up to 96 available indexes
Species Category Any Species
System Compatibility MiSeq,HiSeq X Ten,NextSeq 550,HiSeq 3000,HiSeq X Five,MiSeqDx in Research Mode,MiniSeq,HiSeq 2500,NovaSeq 6000,HiSeq 4000
Variant Class Single Nucleotide Polymorphisms (SNPs),Gene Fusions,Loss of Heterozygosity (LOH),Somatic Variants,Chromosomal Abnormalities,Germline Variants,Structural Variants,Insertions-Deletions (indels),Copy Number Variants (CNVs)
Method Whole-Genome Sequencing
Technology Sequencing
Automation CapABIlity Liquid Handling Robots"
"Illumina/TruSeq Stranded Total RNA Library Prep Kit with Ribo-Zero Globin High Throughput (96 samples, 96 indexes)/RS-12
" Illumina 產(chǎn)品編號: RS-122-2503美 元 價: $10280.00會 員 價: 待定品 牌: Illumina產(chǎn) 地: 美國公 司: Illumina, Inc.產(chǎn)品分類: 分子類>二代測序>DNA文庫制備試劑盒公司分類: Library Preparation Kits "Product Highlights:
TruSeq Stranded Total RNA with Ribo-Zero Globin kits deliver a clear and comprehensive view of the transcriptome from blood-derived RNA, with a fast, efficient sequencing library preparation workflow.
High-quality whole-transcriptome analysis with precise strand information
These kits couple the benefits of Ribo-Zero ribosomal RNA reduction chemistry with RNA sequencing (RNA-Seq) technology for whole-transcriptome analysis of human, mouse, or rat samples. This technology provides:
Uniform coverage and precise measurement of strand orientation
High-confidence discovery of alternative transcripts, antisense expression, and allele-specific expression
Discovery across both coding and multiple forms of non-coding RNA
Efficient ribosomal RNA and globin mRNA removal in a single step
Whole-transcriptome analysis of blood-derived RNA requires the removal of two forms of abundant RNA—ribosomal RNA (both cytoplasmic and mitochondrial) as well as globin mRNA, which is present in high levels in whole blood.
TrADItional removal methods require two independent steps. This means the need for additional reagents, a longer workflow, and more input RNA lost. TruSeq Stranded Total RNA with Ribo-Zero Globin leverages Ribo-Zero chemistry to efficiently remove both forms of abundant RNA in a single, rapid step.
Find an up-to-date list of high-throughput automation vendors with robotic systems compatIBLe with this library preparation kit
Specifications:
Input Quantity 0.1 – 1 ug high-quality purified total RNA from blood
Content Specifications Captures coding RNA plus multiple forms of non-coding RNA
Mechanism of Action Bead-based rRNA depletion, CDNA synthesis, and PCR
Multiplexing Low-throughput kits: Pool up to 12 samples. Or pool up to 24 samples with sets A and B together,High-throughput kit version: Prepare 96 uniquely indexed samples
System Compatibility NovaSeq 5000,Genome Analyzer IIx,HiSeq 2000,NextSeq 500,HiSeq 2500,NextSeq 550,HiSeq 3000,HiSeq 1000
Automation CapABIlity Liquid Handling Robots
Variant Class Transcript Variants,Single Nucleotide Polymorphisms (SNPs),Gene Fusions
Species Category Rat,Mouse
Method Whole-Transcriptome Sequencing
Technology Sequencing"
"Illumina/SureCell™ Whole Transcriptome Analysis 3' Library Prep Kit (2 Cartridges Kit)/20014279/1 Ea
" Illumina 產(chǎn)品編號: 20014279美 元 價: $2500.00會 員 價: 待定品 牌: Illumina產(chǎn) 地: 美國公 司: Illumina, Inc.產(chǎn)品分類: 分子類>二代測序>DNA文庫制備試劑盒公司分類: Library Preparation Kits "Product Highlights:
The Illumina Bio-Rad® SureCell™ Whole Transcriptome Analysis (WTA) 3’ Kit provides a validated process for single-cell RNA sequencing.
Sensitive and unbiased characterization of transcriptional signatures – Highly sensitive and reproducIBLe gene detection in varied individual cells
Comprehensive single-cell RNA sequencing workflow – Fully supported workflow developed in collaboration by technology innovators
Powerful next-generation sequencing integrated with simple data analysis – Proven Illumina sequencing combined with streamlined, user-friendly analysis software
Single cells are individually partitioned into subnanoliter droplets on a disposable cartridge on the one-touch ddSEQ™ Single-Cell Isolator. The cartridge can accommodate multiple samples, and multiple cartridges can be processed in parallel to isolate thousands of cells in a matter of minutes.
Cell lysis and cell barcoding occur inside individual droplets, and single-cell-barcoded RNA-Seq libraries are subsequently prepared using Nextera technology.
Data Analysis
Conduct data analysis via BaseSpace Sequence Hub, the Illumina cloud-based genomics computing environment.
Species Details
This kit has been validated for human and mouse samples. The BaseSpace Single-Cell RNA-Seq App supports analysis of human, mouse, rat, zebrafish, C. elegans, and Drosophila samples.
Specifications:
System Compatibility NextSeq 550,HiSeq 2000,HiSeq 3000,HiSeq 1000,HiSeq 1500,NextSeq 500,HiSeq 2500,NovaSeq 6000,HiSeq 4000
Species Category Human,Mouse
Content Specifications Captures the coding transcriptome (3u0027 enriched), with strand-specific information
Method Whole-Transcriptome Sequencing,mRNA Sequencing
Technology Sequencing
Specialized Sample Types Single Cells
Unbiased, Cell-Size Agnostic RNA-Seq:
Mouse cell lines (A20, NIH3T3) and human cell lines (HEK, BJ) were processed using the SureCell WTA 3′Library Prep Kit. Consistently high numbers of detected genes demonstrates that recovery of transcripts is not limited by cell size.
Confident Single-Cell Transcript Identification:
A. BaseSpace-generated plots of the number of unique molecular identifiers (UMI), i.e. transcripts, assigned to the mouse/mm10 (red) and human/hg19 (blue) genomes for each cell barcode. Unique transcripts mapping to both mouse and human (purple) represent cell doublets. B. Cumulated fraction of unique transcripts assigned to cell barcodes (linear scale). The inflection point (red line) determines the number of barcoded cells detected in the sequencing run.
Confident Cell Population Identification:
A. PCA clustering of 1384 single cells sorted from a 1:1 ratio mixture of HEK 293 and NIH 3T3 cells, sequenced and analyzed with the Single-Cell RNA-Seq BaseSpace App. B. Cell populations cluster based on expression of the human (hg19) RPL13 gene.
Confident Cell Subpopulation Identification:
A. Analysis in the Single-Cell RNA-Seq BaseSpace App using the t-SNE algorithm of a mixture of NIH 3T3 and HEK 293 cells identifies a distinct subpopulation of cells. B. Cells color coded by gene expression of hg19 RPL 13 confirms the identity of the subpopulation as human.
Cell Cycle Analysis of Single Cells by RNA-Seq:
Analysis of cell cycle state using the Single-Cell RNA-Seq BaseSpace App is based on unique transcript counts of genes associated with each phase of the cell cycle, normalized by the total count for each cell. Expression is centered by the median and scaled by the median absolute deviation for each cell cycle."
"Illumina/Nextera XT DNA Library Preparation Kit (96 samples)/FC-131-1096/1 Ea
" Illumina 產(chǎn)品編號: 20014279美 元 價: $2500.00會 員 價: 待定品 牌: Illumina產(chǎn) 地: 美國公 司: Illumina, Inc.產(chǎn)品分類: 分子類>二代測序>DNA文庫制備試劑盒公司分類: Library Preparation Kits "Product Highlights:
Fast Library Prep, Optimized for Small Genomes, PCR Amplicons, and Plasmids
Rapid library preparation – complete library prep in as little as 90 minutes with only 15 minutes of hands-on time
Fast time to results – go from DNA to data in 8 hours with our benchtop sequencers.
Optimized for small genomes, PCR amplicons, and plasmids – one library prep kit for many applications
Innovative sample normalization – eliminates the need for library quantification before sample pooling and sequencing
With Nextera technology, DNA is simultaneously fragmented and tagged with sequencing adapters in a single tube enzymatic reaction. Nextera XT supports ultra-low DNA input of only 1 ng. It enables a wide range of input samples, including small genomes, PCR amplicons greater than 300 bp, plasmids, microbial genomes, concatenated amplicons, and double-stranded CDNA.
Multiplexing of up to 384 samples per Nextera XT library is also available for those projects requiring greater throughput. Plus, the kit includes an innovative bead-based sample normalization that eliminates the need for library quantification prior to pooling and sequencing. Libraries prepared with Nextera XT kits are compatIBLe with all Illumina sequencers.
Find an up-to-date list of high-throughput automation vendors with robotic systems compatIBLe with this library preparation kit
Specifications:
Assay Time 90 minutes
Hands-On Time 15 minutes
Mechanism of Action Enzymatic Fragmentation
Multiplexing Up to 384 uniquely indexed samples may be pooled and sequenced together.
Input Quantity 1 ng DNA
Species Category Drosophila,Any Species,Mammalian,Mouse,Yeast,Zebrafish,Human,Rat,Plant,Nematode,Bacteria
System Compatibility MiSeq,NextSeq 550,NextSeq 500,MiSeq FGx in Research Mode
Method Shotgun Sequencing,Whole-Genome Sequencing,De Novo Sequencing,16S rRNA Sequencing,Amplicon Sequencing,Targeted DNA Sequencing
Variant Class Single Nucleotide Polymorphisms (SNPs),Structural Variants
Specialized Sample Types Low Input,Single Cells
Technology Sequencing
Automation CapABIlity Liquid Handling Robots"
"Illumina/TruSeq SBS Kit v3-HS (50 cycles)/FC-401-3002/1 Ea
" Illumina 產(chǎn)品編號: FC-401-3002美 元 價: $2370.00會 員 價: 待定品 牌: Illumina產(chǎn) 地: 美國公 司: Illumina, Inc.產(chǎn)品分類: 分子類>二代測序>簇生成和測序試劑公司分類: Cluster Generation & Sequencing Reagents "Product Highlights:
TruSeq SBS v3-HS kits contain ready-to-load reagents for accurately determining the DNA sequence of each cluster on a flow cell using sequencing by synthesis (SBS) technology on HiSeq sequencing systems. These kits offer a hands-on preparation time of only two minutes.
To perform a TruSeq v3 run on an enabled HiSeq system, you need one TruSeq SBS Kit v3. Each kit includes sufficient reagents for sequencing 1 flow cell.
The TruSeq v3 reagent kits can be run using either single-read (SR) or paired-end (PE) reads.
The TruSeq PE Cluster Kit v3-cBot-HS enables up to 600 Gb of output, while the TruSeq SR Cluster Kit v3-cBot-HS enables up to 300 Gb of output.
Note: This kit is NOT compatIBLe with the Genome Analyzer.
Specifications:
Maximum Output Up to 600 Gb (with HiSeq 2500 dual flow cell)
Maximum Reads per Run Up to 6 billion paired-end reads (with HiSeq 2500 dual flow cell)
Reagent Type Paired-End Sequencing,Sequencing by Synthesis,Single-Read Sequencing
System Compatibility HiSeq 2000,HiScanSQ,HiSeq 1000,HiSeq 2500
Technology Sequencing"
"Illumina/HiSeq X Ten Reagent Kit v2.5/FC-501-2501/1 Ea
" Illumina 產(chǎn)品編號: FC-501-2501美 元 價: $12750.00會 員 價: 待定品 牌: Illumina產(chǎn) 地: 美國公 司: Illumina, Inc.產(chǎn)品分類: 分子類>二代測序>簇生成和測序試劑公司分類: Cluster Generation & Sequencing Reagents "Product Highlights:
HiSeq X Reagent Kits support high coverage whole-genome sequencing (WGS) with the HiSeq X Series of sequencing systems. By leveraging patterned flow cells, these kits provide increased cluster density to enable significant increases in data output and daily throughput. HiSeq X Reagent Kits support industry-leADIng library preparation options while offering superior data quality and coverage.
HiSeq X Reagent Kits support the TruSeq DNA PCR-Free Library Preparation Kit, for industry-best coverage of challenging genomic regions, and the TruSeq Nano DNA Library Preparation Kit, for efficient sequencing of samples with limited available DNA. Together, the reagent kits and library preparation options deliver exceptional genome coverage, enabling highly accurate and comprehensive variant calling for WGS on the HiSeq X Ten and the HiSeq X Five Systems. The HiSeq X Reagent Kits:
Deliver ultra-high data output
Provide ultra-high daily throughput
Enable sequencing up to 16 genomes per run
Are available in single and multipack configurations
Are compatIBLe with TruSeq DNA PCR-Free and TruSeq Nano DNA LibraryPreparation Kits
HiSeq X Reagent Kits are only compatIBLe with the HiSeq X Series of sequencing systems. HiSeq X Ten Reagent Kits are only available for purchase by HiSeq X Ten users and the HiSeq X Five Reagent Kits are only available for purchase by HiSeq X Five users. Reagents are also available in a multipack configuration to support bulk purchasing with significant reductions in packaging materials.
Latest technology innovation powers population-scale sequencing
HiSeq X Reagent Kits leverage the newest format in Illumina flow cell technology to achieve ultra-high-throughput WGS. Patterned flow cells contain billions of nanowell substrates at fixed locations across both surfaces of the flow cell. The structured organization (see below) provides even spacing of sequencing clusters to deliver significant increases in sequencing reads and total output of the system.
Specifications:
Maximum Output Up to 1800 Gb (1 HiSeq X System with dual flow cells)
Maximum Reads per Run Up to 6 billion
Reagent Type Paired-End Sequencing,Cluster Generation
System Compatibility HiSeq X Ten,HiSeq X Five
Technology Sequencing
"
"Illumina/HiSeq 3000/4000 SBS Kit (150 cycles)/FC-410-1002/1 Ea
" Illumina 產(chǎn)品編號: FC-410-1002美 元 價: $5280.00會 員 價: 待定品 牌: Illumina產(chǎn) 地: 美國公 司: Illumina, Inc.產(chǎn)品分類: 分子類>二代測序>簇生成和測序試劑公司分類: Cluster Generation & Sequencing Reagents "Product Highlights:
HiSeq 3000/4000 SBS (Sequencing by Synthesis) Kits support a wide range of sequencing applications, making them ideal for high-throughput labs performing various genomic applications. CompatIBLe with the HiSeq 3000 and HiSeq 4000 Sequencing Systems, the new kits leverage patterned flow cell technology for even cluster spacing and uniform feature size, to deliver extremely high cluster densities and significant increases in data output and daily throughput.
The HiSeq 3000/4000 SBS Kits enable up to 1500 Gb (1.5 Tb) of output per dual flow cell run when used with the HiSeq 3000/4000 PE Cluster Kit. This high capacity means that more samples can be sequenced simultaneously at a great depth, generating rich and meaningful data.
Specifications:
Maximum Output Up to 1500 Gb (HiSeq 4000 with 2 flow cells), Up to 750 Gb (HiSeq 3000)
Maximum Reads Up to 5 billion (HiSeq 4000), Up to 2.5 billion (HiSeq 3000)
Reagent Type Sequencing by Synthesis
System Compatibility HiSeq 3000,HiSeq 4000
Technology Sequencing"
"Illumina/NextSeq 500/550 Mid Output v2 kit (300 cycles)/FC-404-2003/1 Ea
" Illumina 產(chǎn)品編號: FC-404-2003美 元 價: $1700.00會 員 價: 待定品 牌: Illumina產(chǎn) 地: 美國公 司: Illumina, Inc.產(chǎn)品分類: 分子類>二代測序>簇生成和測序試劑公司分類: Cluster Generation & Sequencing Reagents "Product Highlights:
NextSeq 500/550 v2 sequencing reagent kits bring the power of a high-throughput sequencing system to the desktop, now with improved data quality and the highest yield of error-free reads. These kits offer:
Robust base calling and improved signal-to-noise ratio
Multiple options for both sequencing output and read length
Simplified reagent cartridge configurations, with improved workflow and cartridge loADIng
Intuitive labeling and RFID-encoded reagents
Optimized chemistry with the latest in sequencing by synthesis (SBS) and bridge-amplification cluster generation
The kits deliver powerful sequencing chemistries with as little as 10 minutes of hands-on time. Intuitive labeling and RFID-encoded reagents ensure compatibility with user-defined run configurations.
Ready-to-use cartridges redefine ease-of-use
Pre-configured reagent kits for the NextSeq Series Systems provide all the components needed for sequencing on the platform in 3 ready-to-use cartridges (reagent, flow cell, and buffer). The kits offer simplified cartridge loADIng with the bleach and dual-indexing primers already in the cartridge.
Simply load user-prepared library pools directly into the NextSeq reagent cartridge. The system automatically performs all steps necessary for template amplification and sequencing without user intervention.
Specifications:
Maximum Output 120 Gb (300-cycle high output kit), 60 Gb (150-cycle high output kit), 39 Gb (300-cycle mid output kit), 30 Gb (75-cycle high output kit), 19.5 Gb (150-cycle mid output kit)
Maximum Reads per Run 400 million clusters (high output kits), 130 million clusters (mid output kits)
Reagent Type Paired-End Sequencing,Cluster Generation,Sequencing by Synthesis,Single-Read Sequencing
System Compatibility NextSeq 550,NextSeq 500
Technology Sequencing
"
"Illumina/MiniSeq High Output Reagent Kit (300-cycles)/FC-420-1003/1 Ea
" Illumina 產(chǎn)品編號: FC-420-1003美 元 價: $1545.00會 員 價: 待定品 牌: Illumina產(chǎn) 地: 美國公 司: Illumina, Inc.產(chǎn)品分類: 分子類>二代測序>簇生成和測序試劑公司分類: Cluster Generation & Sequencing Reagents "Product Highlights:
MiniSeq System sequencing reagent kits bring the power and reliABIlity of proven Illumina next-generation sequencing (NGS) to labs of all sizes. Access cost-efficient sequencing with high data quality, even for low numbers of samples. These kits offer:
Robust base calling and optimal signal-to-noise ratio
Multiple options for both sequencing output and read length
Simple workflow that reduces chance for error through the integration of clustering, sequencing and wash reagents into a single cartridge
Intuitive labeling and RFID-encoded reagents
Optimized chemistry with the latest in Illumina sequencing by synthesis (SBS) chemistry
Configurations for various applications
MiniSeq Reagent Kits offer a wide range of solutions for applications ranging from gene expression and small RNA profiling to targeted DNA amplicon sequencing and small genome sequencing. High accuracy and paired-end sequencing capABIlity are built into every reagent kit.
Ready-to-use cartridges redefine ease of use
Preconfigured reagent kits for the MiniSeq System provide all the components needed for cluster generation, sequencing and wash on the platform in 1 premixed, integrated, RFID-enabled cartridge. Simply load user-prepared library pools directly into the MiniSeq System. The system automatically performs all steps necessary for template amplification and sequencing without user intervention.
The kits deliver powerful sequencing chemistries with as little as 10 minutes of hands-on time. Intuitive labeling and RFID-encoded reagents ensure compatibility with user-defined run configurations.
Specifications:
Maximum Output 7.5 Gb (300-cycle high output kit), 3.75 Gb (150-cycle high output kit), 2.4 Gb (300-cycle mid output kit), 1.875 Gb (75-cycle high output kit)
Maximum Reads Per Run Up to 25 million (high output kits), Up to 8 million (mid output kits)
Reagent Type Paired-End Sequencing,Cluster Generation,Sequencing by Synthesis
Technology Sequencing
System Compatibility MiniSeq"
"Illumina/TruSeq® Rapid Exome Kit (8 rxn × 6 plex)/FC-144-1002/1 Ea
" Illumina 產(chǎn)品編號: FC-144-1002美 元 價: $4800.00會 員 價: 待定品 牌: Illumina產(chǎn) 地: 美國公 司: Illumina, Inc.產(chǎn)品分類: 分子類>二代測序>DNA文庫制備試劑盒公司分類: Library Preparation Kits "Product Highlights:
The TruSeq Rapid Exome Library Prep Kit delivers a simple, efficient method for high-confidence calling of exonic variants. The fast library preparation and exome enrichment workflow deliver libraries in 1 day with no need for additional equipment, giving labs the flexibility to plan projects according to sample volume. This kit offers:
Enhanced transposome chemistry results in reduced bias, providing consistent library preparation and exome enrichment.
Rapid, automation-friendly workflow completes in 1 day with only 3 hours of hands-on time.
High coverage uniformity across exonic regions and on-target %
Proven TruSeq Data Quality
The TruSeq Rapid Exome Library Prep Kit delivers an average of 75% of on-target sequencing reads. This high on-target percentage requires fewer sequencing cycles to reach desired coverage levels, but still achieves uniform coverage for high-confidence results.
To learn more about calculating coverage estimates, see the sequencing coverage calculator.
Find an up-to-date list of high-throughput automation vendors with robotic systems compatIBLe with this library preparation kit
Specifications:
Assay Time 1 day
Hands-On Time 3 hours
Input Quantity 50 ng genomic DNA
Content Specifications Captures coding exons. Covers 45 Mb of exonic content (≥98% of RefSeq, CCDS, and Ensembl coding content).
Mechanism of Action Transposase-based fragmentation and exome enrichment with biotinylated capture probes
Multiplexing Up to 12-plex enrichment
Technology Sequencing
Species Category Human
Automation CapABIlity Liquid Handling Robots
System Compatibility NextSeq 500,NovaSeq 6000,HiSeq 4000
Method Exome Sequencing
"
"Illumina/TruSeq RNA Access Library Prep Kit - Set A (12 indexes, 48 samples)/RS-301-2001/1 Ea
" Illumina 產(chǎn)品編號: RS-301-2001美 元 價: $7492.00會 員 價: 待定品 牌: Illumina產(chǎn) 地: 美國公 司: Illumina, Inc.產(chǎn)品分類: 分子類>二代測序>DNA文庫制備試劑盒公司分類: Library Preparation Kits "Product Highlights:
TruSeq RNA Access kits convert total RNA into template molecules of known strand origin, followed by sequence-specific capture of coding RNA. This provides a low-cost solution for analyzing human RNA isolated from FFPE (formalin-fixed, paraffin-embedded) tissues and other low-quality samples.
AffordABIlity and focus - isolating human transcriptome coding regions maximizes discovery power at a fraction of the sequencing depth
High-quality data from difficult samples - optimized for sequencing RNA from degraded samples, including FFPE tissues
Samples with limited starting material - greatly reduced sample input requirements (as little as 10 ng total RNA from fresh or frozen samples or 20 ng total RNA from degraded samples) while maintaining high sensitivity
TruSeq RNA Access Kit generates RNA-Seq libraries from degraded samples that focus on the RNA coding regions. Isolating these high-value content regions maximizes discovery power, while requiring only a fraction of the read depth of total RNA sequencing. The results are low input requirements, high sample throughput, and cost-effective transcriptome analysis.
Find an up-to-date list of high-throughput automation vendors with robotic systems compatIBLe with this library preparation kit
Specifications:
Assay Time ~2 Days
Hands-on Time ~11 hours
Input Quantity 10 ng total RNA from fresh/frozen samples, or 20 ng total RNA from FFPE samples
Content Specifications Captures the coding transcriptome/RNA exome
Mechanism of Action Biotinylated capture probes that target coding RNA. Does not require RNA with poly-A tails.
Multiplexing Up to 24 unique indexes and 4-plex pre-enrichment pooling
System Compatibility NovaSeq 5000,NextSeq 550,HiSeq 3000,NextSeq 500,HiSeq 2500,NovaSeq 6000,HiSeq 4000
Variant Class Single Nucleotide Polymorphisms (SNPs),Novel Transcripts,Transcript Variants
Specialized Sample Types FFPE,Low Input
Technology Sequencing
Method mRNA Sequencing,Exome Sequencing
Species Category Human
Automation CapABIlity Liquid Handling Robots"
"Illumina/Nextera Mate Pair Library Prep Kit (12 indexes, 48 gel-free samples or 12 gel-plus samples)/FC-132-1001/1 Ea
" Illumina 產(chǎn)品編號: FC-132-1001美 元 價: $4162.00會 員 價: 待定品 牌: Illumina產(chǎn) 地: 美國公 司: Illumina, Inc.產(chǎn)品分類: 分子類>二代測序>DNA文庫制備試劑盒公司分類: Library Preparation Kits "Product Highlights:
The Nextera Mate Pair Library Preparation Kit is an ideal approach for de novo sequencing, genome finishing, and the detection of structural variation. It is compatIBLe with large DNA genomes — even the most complex genomes such as those derived from cancer.
Sequence precious samples when limited DNA is available
Generate highly diverse libraries with premier data quality
Prepare sequencing-ready libraries in less than two days
Requires 10 Times Less DNA Input Than Other Protocols
Both gel-free and gel-plus protocols are available:
The gel-free protocol allows mate pair sequencing when limited DNA is available. It is designed for applications such as de novo assembly of small genomes.
The gel-plus protocol is ideal for challenging mate pair applications, such as de novo assembly of complex genomes.
Increased Library Diversity and Data Quality
The kit provides identifiable junction sequences for accurate identification of the two halves of the mate pair fragment.
Only biotinylates DNA molecules at fragmentation sites, avoiding troublesome internal biotinylation
Allows for the creation of millions of unique fragments
Increased library diversity generates fewer duplicate reads and premier data quality
Fast and Simple Mate Pair Workflow
The Nextera Mate Pair kit uses TruSeq DNA Library Preparation master-mixed reagents, thereby reducing the number of assay steps and hands-on time required.
Fewer pipetting steps simplifies workflow and reduces sample loss
Gel-free protocol option and on-bead reactions simplify purification steps and shorten protocol hands-on time
Specifications:
Assay Time 1.5 - 2 days
Hands-On Time 1.5 - 2 hours
Input Quantity 1 ug DNA for gel-free protocol, 4 ug DNA for gel-plus protocol
Multiplexing Can multiplex up to 12 samples, depending on genome size. CompatIBLe with most large DNA genomes.
Mechanism of Action Methods that target the junction site of large circularized fragments. Mechanical fragmentation (COVARIS).
System Compatibility MiSeq,HiSeq 3000,HiSeq 2500,HiSeq 4000
Species Category Other,Mammalian,Mouse,Human,Rat,Plant,Bacteria
Variant Class Single Nucleotide Polymorphisms (SNPs),Structural Variants,Insertions-Deletions (indels)
Method Whole-Genome Sequencing,De Novo Sequencing,Long-Read Sequencing
Technology Sequencing"
"Illumina/MiSeq Reagent Kit v3 (600-cycle)/MS-102-3003/1 Ea
" Illumina 產(chǎn)品編號: MS-102-3003美 元 價: $1530.00會 員 價: 待定品 牌: Illumina產(chǎn) 地: 美國公 司: Illumina, Inc.產(chǎn)品分類: 分子類>二代測序>簇生成和測序試劑公司分類: Cluster Generation & Sequencing Reagents "Product Highlights:
MiSeq Reagent Kits v3 enable the highest output of all MiSeq kits. The v3 kits retain the same pre-filled, ready-to-use reagent cartridges as the v1 and v2 kits, but offer improved chemistry to increase cluster density and read length as well as improve quality (Q) scores.
MiSeq Reagent Kit v3 allows researchers to:
Double the output of a single run
Extend read lengths up to 2 x 300 bp with the 600-cycle kit
Increase the number of reads to 25 million to unlock new applications
Updated system software unlocks the full benefits of the v3 kits. Access the latest software.
The MiSeq v3 kits can achieve double the amount of output per flow cell. Kits are available in a 600-cycle format to allow the longest read lengths on any Illumina sequencing system. There is also a 150-cycle format that enables counting applications. In addition, all MiSeq Reagent Kit v2 configurations will continue to be available. MiSeq reagent components are RFID-encoded and interact intelligently with the MiSeq System to validate compatibility with user-defined applications.
Reagent Kit No. of Reads Kit Size (cycles) Output (max.) 2 × 75 Output 2 × 300 Output
MiSeq Reagent Kit v3 25 M 150, 600 15 Gb 3.8 Gb 15 Gb
Gb = gigabases, M = millions
Specifications:
Maximum Output 15 Gb (600-cycle), 3.8 Gb (150-cycle)
Maximum Reads Up to 25 Million
Reagent Type Paired-End Sequencing,Cluster Generation,Sequencing by Synthesis
System Compatibility MiSeq,MiSeqDx in Research Mode,MiSeq FGx in Research Mode
Technology Sequencing"
"Illumina/TruSeq® Rapid Exome Kit (8 rxn × 3 plex)/FC-144-1001/1 Ea
" Illumina 產(chǎn)品編號: FC-144-1001美 元 價: $2400.00會 員 價: 待定品 牌: Illumina產(chǎn) 地: 美國公 司: Illumina, Inc.產(chǎn)品分類: 分子類>二代測序>DNA文庫制備試劑盒公司分類: Library Preparation Kits "Product Highlights:
The TruSeq Rapid Exome Library Prep Kit delivers a simple, efficient method for high-confidence calling of exonic variants. The fast library preparation and exome enrichment workflow deliver libraries in 1 day with no need for additional equipment, giving labs the flexibility to plan projects according to sample volume. This kit offers:
Enhanced transposome chemistry results in reduced bias, providing consistent library preparation and exome enrichment.
Rapid, automation-friendly workflow completes in 1 day with only 3 hours of hands-on time.
High coverage uniformity across exonic regions and on-target %
Proven TruSeq Data Quality
The TruSeq Rapid Exome Library Prep Kit delivers an average of 75% of on-target sequencing reads. This high on-target percentage requires fewer sequencing cycles to reach desired coverage levels, but still achieves uniform coverage for high-confidence results.
To learn more about calculating coverage estimates, see the sequencing coverage calculator.
Find an up-to-date list of high-throughput automation vendors with robotic systems compatIBLe with this library preparation kit
Specifications:
Assay Time 1 day
Hands-On Time 3 hours
Input Quantity 50 ng genomic DNA
Content Specifications Captures coding exons. Covers 45 Mb of exonic content (≥98% of RefSeq, CCDS, and Ensembl coding content).
Mechanism of Action Transposase-based fragmentation and exome enrichment with biotinylated capture probes
Multiplexing Up to 12-plex enrichment
Technology Sequencing
Species Category Human
Automation CapABIlity Liquid Handling Robots
System Compatibility NextSeq 500,NovaSeq 6000,HiSeq 4000
Method Exome Sequencing
"
"Illumina/TruSeq Stranded Total RNA Library Prep Kit with Ribo-Zero Globin Set B (48 samples, 12 indexes)/RS-122-2502/1 E
" Illumina 產(chǎn)品編號: RS-122-2502美 元 價: $5630.00會 員 價: 待定品 牌: Illumina產(chǎn) 地: 美國公 司: Illumina, Inc.產(chǎn)品分類: 分子類>二代測序>DNA文庫制備試劑盒公司分類: Library Preparation Kits "Product Highlights:
TruSeq Stranded Total RNA with Ribo-Zero Globin kits deliver a clear and comprehensive view of the transcriptome from blood-derived RNA, with a fast, efficient sequencing library preparation workflow.
High-quality whole-transcriptome analysis with precise strand information
These kits couple the benefits of Ribo-Zero ribosomal RNA reduction chemistry with RNA sequencing (RNA-Seq) technology for whole-transcriptome analysis of human, mouse, or rat samples. This technology provides:
Uniform coverage and precise measurement of strand orientation
High-confidence discovery of alternative transcripts, antisense expression, and allele-specific expression
Discovery across both coding and multiple forms of non-coding RNA
Efficient ribosomal RNA and globin mRNA removal in a single step
Whole-transcriptome analysis of blood-derived RNA requires the removal of two forms of abundant RNA—ribosomal RNA (both cytoplasmic and mitochondrial) as well as globin mRNA, which is present in high levels in whole blood.
TrADItional removal methods require two independent steps. This means the need for additional reagents, a longer workflow, and more input RNA lost. TruSeq Stranded Total RNA with Ribo-Zero Globin leverages Ribo-Zero chemistry to efficiently remove both forms of abundant RNA in a single, rapid step.
Find an up-to-date list of high-throughput automation vendors with robotic systems compatIBLe with this library preparation kit
Specifications:
Input Quantity 0.1 – 1 ug high-quality purified total RNA from blood
Content Specifications Captures coding RNA plus multiple forms of non-coding RNA
Mechanism of Action Bead-based rRNA depletion, CDNA synthesis, and PCR
Multiplexing Low-throughput kits: Pool up to 12 samples. Or pool up to 24 samples with sets A and B together,High-throughput kit version: Prepare 96 uniquely indexed samples
System Compatibility NovaSeq 5000,Genome Analyzer IIx,HiSeq 2000,NextSeq 500,HiSeq 2500,NextSeq 550,HiSeq 3000,HiSeq 1000
Automation CapABIlity Liquid Handling Robots
Variant Class Transcript Variants,Single Nucleotide Polymorphisms (SNPs),Gene Fusions
Species Category Rat,Mouse
Method Whole-Transcriptome Sequencing
Technology Sequencing
"
"Illumina/TruSeq Stranded Total RNA Library Prep Kit with Ribo-Zero Globin Set A (48 samples, 12 indexes)/RS-122-2501/1 E
" Illumina 產(chǎn)品編號: RS-122-2501美 元 價: $5630.00會 員 價: 待定品 牌: Illumina產(chǎn) 地: 美國公 司: Illumina, Inc.產(chǎn)品分類: 分子類>二代測序>DNA文庫制備試劑盒公司分類: Library Preparation Kits "Product Highlights:
TruSeq Stranded Total RNA with Ribo-Zero Globin kits deliver a clear and comprehensive view of the transcriptome from blood-derived RNA, with a fast, efficient sequencing library preparation workflow.
High-quality whole-transcriptome analysis with precise strand information
These kits couple the benefits of Ribo-Zero ribosomal RNA reduction chemistry with RNA sequencing (RNA-Seq) technology for whole-transcriptome analysis of human, mouse, or rat samples. This technology provides:
Uniform coverage and precise measurement of strand orientation
High-confidence discovery of alternative transcripts, antisense expression, and allele-specific expression
Discovery across both coding and multiple forms of non-coding RNA
Efficient ribosomal RNA and globin mRNA removal in a single step
Whole-transcriptome analysis of blood-derived RNA requires the removal of two forms of abundant RNA—ribosomal RNA (both cytoplasmic and mitochondrial) as well as globin mRNA, which is present in high levels in whole blood.
TrADItional removal methods require two independent steps. This means the need for additional reagents, a longer workflow, and more input RNA lost. TruSeq Stranded Total RNA with Ribo-Zero Globin leverages Ribo-Zero chemistry to efficiently remove both forms of abundant RNA in a single, rapid step.
Find an up-to-date list of high-throughput automation vendors with robotic systems compatIBLe with this library preparation kit
Specifications:
Input Quantity 0.1 – 1 ug high-quality purified total RNA from blood
Content Specifications Captures coding RNA plus multiple forms of non-coding RNA
Mechanism of Action Bead-based rRNA depletion, CDNA synthesis, and PCR
Multiplexing Low-throughput kits: Pool up to 12 samples. Or pool up to 24 samples with sets A and B together,High-throughput kit version: Prepare 96 uniquely indexed samples
System Compatibility NovaSeq 5000,Genome Analyzer IIx,HiSeq 2000,NextSeq 500,HiSeq 2500,NextSeq 550,HiSeq 3000,HiSeq 1000
Automation CapABIlity Liquid Handling Robots
Variant Class Transcript Variants,Single Nucleotide Polymorphisms (SNPs),Gene Fusions
Species Category Rat,Mouse
Method Whole-Transcriptome Sequencing
Technology Sequencing
"
"Illumina/HiSeq SR Cluster Kit v4 cBot/GD-401-4001/1 Ea
" Illumina 產(chǎn)品編號: GD-401-4001美 元 價: $4050.00會 員 價: 待定品 牌: Illumina產(chǎn) 地: 美國公 司: Illumina, Inc.產(chǎn)品分類: 分子類>二代測序>簇生成和測序試劑公司分類: Cluster Generation & Sequencing Reagents "Product Highlights:
The HiSeq SR (Single Read) Cluster Kit v4 cBot provides reagents for the cBot cluster amplification system. Reagents are provided in a pre-mixed, 96-well plate format that requires minimal reagent preparation. DNA library samples are bound to complimentary adapter oligos grafted on the surface of the flow cell.
The templates are copied from the hybridization primer by 3’ extension using a high-fidelity DNA polymerase. Copies are isothermally amplified to create clonal clusters of ~1000 copies each, ready for sequencing on enabled HiSeq systems*."
Illumina
"Illumina/TruSeq DNA Methylation Kit (12 reactions)/EGMK81312/1 Ea
" Illumina 產(chǎn)品編號: EGMK81312美 元 價: $1009.00會 員 價: 待定品 牌: Illumina產(chǎn) 地: 美國公 司: Illumina, Inc.產(chǎn)品分類: 分子類>二代測序>DNA文庫制備試劑盒公司分類: Library Preparation Kits "Product Highlights:
Unlock small samples (50–100 ng DNA input)
CpG, CHH, & CHG regions included for comprehensive, whole-genome results
Fast protocol – five-hour method
Capture full sample diversity
Sequence the entire sample–no loss of information
The process of bisulfite treatment denatures genomic DNA into single stranded DNA. TruSeq DNA Methylation converts single stranded DNA into an Illumina sequencing library. All ssDNA fragments are captured into an Illumina sequencing library, therefore eliminating the loss of diversity associated with other methods.
Supported analysis in the cloud
TruSeq DNA Methylation libraries can be aligned to the human genome and compared for differential methylation with Illumina BaseSpace Apps MethylSeq and MethylKit. These applications are fully supported and were developed specifically for TruSeq DNA Methylation library preparation.
Example data sets for TruSeq DNA Methylation libraries, also available in BaseSpace Sequence Hub Data Central (use the “Methyl Seq” category filter), demonstrate unparalleled quality and seamless analysis.
Deep coverage of critical genomic regions
Depth of coverage is enhanced in genomic areas with BIOLOGical utility. TruSeq DNA Methylation captures full sample diversity of critical areas, including:
Coding region start and end for exons from the canonical transcript of protein coding genes for genes known to be involved in cancer, taken from SOMA and CRUK panels (as well as literature-derived cancer genes)
Genes defined by the American College of Medical Genetics as being medically relevant (ACMG genes)
Exonic coding regions from Ensemble 70
List of 100 promoters defined by the Broad Institute as being of high interest and difficult to sequence"
"Illumina/TruSeq Small RNA Set C MiniSeq Kit (1 library prep and 2 MiniSeq reagents)/20005615/1 Ea
" Illumina 產(chǎn)品編號: 20005615美 元 價: $3200.00會 員 價: 待定品 牌: Illumina產(chǎn) 地: 美國公 司: Illumina, Inc.產(chǎn)品分類: 分子類>二代測序>DNA文庫制備試劑盒公司分類: Library Preparation Kits "Product Highlights:
TruSeq Small RNA Library Preparation Kits provide reagents to generate small RNA libraries directly from total RNA. MicroRNAs (miRNAs) generated by Dicer processing are efficiently targeted by the included modified adapters.
These kits enable multiplexed sequencing with the introduction of 48 unique indexes, allowing miRNA and small RNA discovery and profiling throughput to match the unparalleled output of Illumina sequencing. Indexes are added in a universal amplification reaction, greatly reducing ligation bias and ensuring accurate measurement of miRNA expression.
Workflow improvements enable streamlined sample preparation, allowing economical studies covering all small RNA transcripts in any species. CompatIBLe applications include finding novel miRNAs, characterizing variation such as isomers with single-base resolution, and analyzing differential expression without prior assumptions.
TruSeq Small RNA Sample Datasets
The Human Brain Reference RNA (HBRR) and Universal Human Reference RNA (UHRR) samples were prepared using the TruSeq Small RNA Library Prep Kit. These libraries were sequenced on the MiniSeq System using the MiniSeq High Output Reagent Kit at a 1 x 36 bp read length configuration. The total yield was 0.91 Gb with 97% of bases at or above Q30.
Browse the Data In BaseSpace Sequence Hub:
View Run (primary analysis and metrics)
View Project (secondary analysis with BaseSpace Apps)
Specifications:
Assay Time ~10.5 hours
Hands-On Time ~30 minutes
Input Quantity 25 to 100 ng total RNA from species with polyA tails
Content Specifications Captures the coding transcriptome with strand information
Mechanism of Action Oligo-dT beads capture polyA tails
Multiplexing Up to 24-plex pooling with additional NeoPrep runs
Sample Throughput Up to 16 samples per NeoPrep library card
Species Category Drosophila,Any Species,Mouse,Zebrafish,Human,Rat,Plant,Nematode
System Compatibility MiSeq,NextSeq 550,MiniSeq,NextSeq 500
Specialized Sample Types FFPE,Low Input
Technology Sequencing
Automation CapABIlity Liquid Handling Robots
Variant Class Novel Transcripts,Transcript Variants
Method miRNA and Small RNA Sequencing"
"Illumina/MiSeq FGx Reagent Kit/TG-143-1001/1 Ea
" Illumina 產(chǎn)品編號: TG-143-1001美 元 價: $1400.00會 員 價: 待定品 牌: Illumina產(chǎn) 地: 美國公 司: Illumina, Inc.產(chǎn)品分類: 分子類>二代測序>簇生成和測序試劑公司分類: Cluster Generation & Sequencing Reagents "Product Highlights:
This sequencing kit for forensic genomics applications is based on the MiSeq Reagent Kit v3, which enables the highest output of all MiSeq kits. This kit allows forensic genomics laboratories to:
Simultaneously analyze a dense set of forensically relevant Markers at low, medium, or high sample throughput
Extend read lengths
Increase the number of reads to unlock new applications
The MiSeq FGx Reagent Kit uses pre-filled, ready-to-use reagent cartridges, and offers the improved v3 chemistry to increase cluster density and read length as well as improve quality.
MiSeq FGx Reagent Kit components are RFID-encoded and interact intelligently with the MiSeq FGx System to validate compatibility with forensic genomic applications.
Specifications:
Maximum Output 15 Gb
Maximum Reads per Run 14 million
Reagent Type Paired-End Sequencing,Cluster Generation,Sequencing by Synthesis
Technology Sequencing
System Compatibility MiSeq FGx"
"Illumina/TruSeq Targeted RNA Index Kit D (96 indexes, 384 samples)/RT-402-1004/1 Ea
" Illumina 產(chǎn)品編號: RT-402-1004美 元 價: $1019.00會 員 價: 待定品 牌: Illumina產(chǎn) 地: 美國公 司: Illumina, Inc.產(chǎn)品分類: 分子類>二代測序>DNA文庫制備試劑盒公司分類: Library Preparation Kits "Product Highlights:
TruSeq Targeted RNA Expression Kits enable highly customizable mid- to high-plex gene expression profiling studies.
You can define panels of 12-1,000 assays to target individual exons, isoforms, splice junctions, coding SNPS (cSNPs), gene fusions, and non-coding RNA transcripts, plus multiplex up to 384 samples. Generate the data equivalent of up to 25,000 individual RT-PCR assays in a single run.*
Assays include convenient online panel design and ordering, a rapid and simple workflow starting with as little as 50 ng of RNA, and automated, on-instrument data analysis.
Types of Study Designs
Custom panels—select up to 1000 targets from a database of over 400,000 predesigned assays.
Add-on (supplemental) content—add a second oligo pool of up to 1000 targets to a previously designed TruSeq Targeted RNA Expression custom panel.
Start a Custom Project
Order custom panels using DesignStudio, a free, user-friendly, web-based tool. Simply select the assays you need and add them to your order, with no design time.
Log in to DesignStudio
Browse TruSeq Targeted RNA Sample Data
Human Brain Reference RNA (HBRR), Universal Human Reference RNA (UHRR), and human liver RNA samples were prepared using the TruSeq Targeted RNA Expression Kit.
These libraries were sequenced on the MiniSeq System using the MiniSeq High Output Reagent Kit at a 1 x 51 bp read length configuration. The total yield was 2.04 Gb with 96.5% of bases at or above Q30.
Note that access to this data requires a BaseSpace Sequence Hub login.
Register for BaseSpace Sequence Hub
View TruSeq Targeted RNA Project Data
(secondary analysis with BaseSpace Apps)
*Refers to instruments with catalog number SY-410-1001 and upgrade, or catalog number SY-410-1003
Specifications:
Assay Time 1 day
Hands-On Time 4 hours
Input Quantity 50 ng RNA,50 ng high-quality total RNA,≥ 200 ng FFPE total RNA; Recommended quantity may vary with expression level, target plexity, and sample quality
Content Specifications Choose from 400,000+ pre-designed targeted RNA-Seq assays. Or add content to a fixed panel or previously designed custom panel.
Multiplexing Up to 384 samples per sequencing run
Mechanism of Action Amplification
Method Targeted RNA Sequencing
Variant Class Single Nucleotide Polymorphisms (SNPs),Gene Fusions,Transcript Variants
Specialized Sample Types FFPE
"
"Illumina/TruSeq Small RNA Set B MiniSeq Kit (1 library prep and 2 MiniSeq reagents)/20005614/1 Ea
" Illumina 產(chǎn)品編號: 20005614美 元 價: $3200.00會 員 價: 待定品 牌: Illumina產(chǎn) 地: 美國公 司: Illumina, Inc.產(chǎn)品分類: 分子類>二代測序>DNA文庫制備試劑盒公司分類: Library Preparation Kits "Product Highlights:
TruSeq Small RNA Library Preparation Kits provide reagents to generate small RNA libraries directly from total RNA. MicroRNAs (miRNAs) generated by Dicer processing are efficiently targeted by the included modified adapters.
These kits enable multiplexed sequencing with the introduction of 48 unique indexes, allowing miRNA and small RNA discovery and profiling throughput to match the unparalleled output of Illumina sequencing. Indexes are added in a universal amplification reaction, greatly reducing ligation bias and ensuring accurate measurement of miRNA expression.
Workflow improvements enable streamlined sample preparation, allowing economical studies covering all small RNA transcripts in any species. CompatIBLe applications include finding novel miRNAs, characterizing variation such as isomers with single-base resolution, and analyzing differential expression without prior assumptions.
TruSeq Small RNA Sample Datasets
The Human Brain Reference RNA (HBRR) and Universal Human Reference RNA (UHRR) samples were prepared using the TruSeq Small RNA Library Prep Kit. These libraries were sequenced on the MiniSeq System using the MiniSeq High Output Reagent Kit at a 1 x 36 bp read length configuration. The total yield was 0.91 Gb with 97% of bases at or above Q30.
Browse the Data In BaseSpace Sequence Hub:
View Run (primary analysis and metrics)
View Project (secondary analysis with BaseSpace Apps)
Specifications:
Assay Time ~10.5 hours
Hands-On Time ~30 minutes
Input Quantity 25 to 100 ng total RNA from species with polyA tails
Content Specifications Captures the coding transcriptome with strand information
Mechanism of Action Oligo-dT beads capture polyA tails
Multiplexing Up to 24-plex pooling with additional NeoPrep runs
Sample Throughput Up to 16 samples per NeoPrep library card
Species Category Drosophila,Any Species,Mouse,Zebrafish,Human,Rat,Plant,Nematode
System Compatibility MiSeq,NextSeq 550,MiniSeq,NextSeq 500
Specialized Sample Types FFPE,Low Input
Technology Sequencing
Automation CapABIlity Liquid Handling Robots
Variant Class Novel Transcripts,Transcript Variants
Method miRNA and Small RNA Sequencing"
"Illumina/TruSeq Small RNA Library Prep Kit -Set B (24 rxns) (Set B: indexes 13-24)/RS-200-0024/1 Ea
" Illumina 產(chǎn)品編號: RS-200-0024美 元 價: $2450.00會 員 價: 待定品 牌: Illumina產(chǎn) 地: 美國公 司: Illumina, Inc.產(chǎn)品分類: 分子類>二代測序>DNA文庫制備試劑盒公司分類: Library Preparation Kits "Product Highlights:
TruSeq Small RNA Library Preparation Kits provide reagents to generate small RNA libraries directly from total RNA. MicroRNAs (miRNAs) generated by Dicer processing are efficiently targeted by the included modified adapters.
These kits enable multiplexed sequencing with the introduction of 48 unique indexes, allowing miRNA and small RNA discovery and profiling throughput to match the unparalleled output of Illumina sequencing. Indexes are added in a universal amplification reaction, greatly reducing ligation bias and ensuring accurate measurement of miRNA expression.
Workflow improvements enable streamlined sample preparation, allowing economical studies covering all small RNA transcripts in any species. CompatIBLe applications include finding novel miRNAs, characterizing variation such as isomers with single-base resolution, and analyzing differential expression without prior assumptions.
TruSeq Small RNA Sample Datasets
The Human Brain Reference RNA (HBRR) and Universal Human Reference RNA (UHRR) samples were prepared using the TruSeq Small RNA Library Prep Kit. These libraries were sequenced on the MiniSeq System using the MiniSeq High Output Reagent Kit at a 1 x 36 bp read length configuration. The total yield was 0.91 Gb with 97% of bases at or above Q30.
Browse the Data In BaseSpace Sequence Hub:
View Run (primary analysis and metrics)
View Project (secondary analysis with BaseSpace Apps)
Specifications:
Assay Time ~10.5 hours
Hands-On Time ~30 minutes
Input Quantity 25 to 100 ng total RNA from species with polyA tails
Content Specifications Captures the coding transcriptome with strand information
Mechanism of Action Oligo-dT beads capture polyA tails
Multiplexing Up to 24-plex pooling with additional NeoPrep runs
Sample Throughput Up to 16 samples per NeoPrep library card
Species Category Drosophila,Any Species,Mouse,Zebrafish,Human,Rat,Plant,Nematode
System Compatibility MiSeq,NextSeq 550,MiniSeq,NextSeq 500
Specialized Sample Types FFPE,Low Input
Technology Sequencing
Automation CapABIlity Liquid Handling Robots
Variant Class Novel Transcripts,Transcript Variants
Method miRNA and Small RNA Sequencing"
"Illumina/TruSeq Stranded mRNA Library Prep Kit for NeoPrep (16 samples, 24 indexes)/NP-202-1001/1 Ea
" Illumina 產(chǎn)品編號: NP-202-1001美 元 價: $880.00會 員 價: 待定品 牌: Illumina產(chǎn) 地: 美國公 司: Illumina, Inc.產(chǎn)品分類: 分子類>二代測序>DNA文庫制備試劑盒公司分類: Library Preparation Kits "Product Highlights:
The TruSeq Stranded mRNA Library Prep Kit for NeoPrep offers a streamlined, cost-efficient, and scalable solution for coding transcriptome analysis. It enables robust interrogation of both standard and low-quality samples.
Simplified and seamless workflow solution – Generate libraries with minimal hands-on time
Unparalleled performance and reproducibility – Interrogate gene expression with TruSeq Stranded mRNA coverage and quality, and reduced user variABIlity
Low input requirement – Begin library prep with as little as 25 ng total RNA
Precise and Accurate
Get precise measurement of mRNA strand orientation for detection of antisense transcription, enhanced transcript annotation, and increased alignment efficiency. High coverage uniformity enhances the discovery of features such as alternative transcripts, gene fusions, and allele-specific expression.
Cost-Efficient
Stranded information identifies from which of the 2 DNA strands a given RNA transcript was derived. This information provides increased confidence in transcript annotation, particularly for nonhuman samples. Identifying strand origin increases the percentage of reads that align, reducing sequencing costs per sample.
NeoPrep System enhances TruSeq Stranded mRNA performance
The NeoPrep System enhances TruSeq Stranded mRNA performance by providing high-quality reproducIBLe results, even with low input amounts of RNA. Digital microfluidics technology precisely manipulates droplets that perform the library prep workflow, within the tightly controlled environment of the NeoPrep library card.
A simple, intuitive workflow delivers 16 libraries, eliminating most manual steps, and reducing hands-on time from ~4.5 hours to just 30 minutes. In addition, digital microfluidics requires less RNA input, enabling excellent performance from as little as 25 ng of total RNA.
Specifications:
Assay Time ~10.5 hours
Hands-On Time ~30 minutes
Input Quantity 25 to 100 ng total RNA from species with polyA tails
Content Specifications Captures the coding transcriptome with strand information
Mechanism of Action Oligo-dT beads capture polyA tails
Multiplexing Up to 24-plex pooling with additional NeoPrep runs
Sample Throughput Up to 16 samples per NeoPrep library card
System Compatibility Genome Analyzer IIx,HiSeq 2000,MiSeq,NextSeq 550,HiSeq 3000,HiSeq 1000,NeoPrep,HiSeq 1500,NextSeq 500,HiSeq 2500,HiSeq 4000
Species Category Other,Mammalian,Bovine,Mouse,Human,Rat
Variant Class Single Nucleotide Polymorphisms (SNPs),Gene Fusions,Novel Transcripts,Transcript Variants
Technology Sequencing
Method mRNA Sequencing
Automation CapABIlity NeoPrep Digital Microfluidics"
"Illumina/TruSeq Targeted RNA Index Kit A (96 indexes, 384 samples)/RT-402-1001/1 Ea
" Illumina 產(chǎn)品編號: RT-402-1001美 元 價: $1019.00會 員 價: 待定品 牌: Illumina產(chǎn) 地: 美國公 司: Illumina, Inc.產(chǎn)品分類: 分子類>二代測序>DNA文庫制備試劑盒公司分類: Library Preparation Kits "Product Highlights:
TruSeq Targeted RNA Expression Kits enable highly customizable mid- to high-plex gene expression profiling studies.
You can define panels of 12-1,000 assays to target individual exons, isoforms, splice junctions, coding SNPS (cSNPs), gene fusions, and non-coding RNA transcripts, plus multiplex up to 384 samples. Generate the data equivalent of up to 25,000 individual RT-PCR assays in a single run.*
Assays include convenient online panel design and ordering, a rapid and simple workflow starting with as little as 50 ng of RNA, and automated, on-instrument data analysis.
Types of Study Designs
Custom panels—select up to 1000 targets from a database of over 400,000 predesigned assays.
Add-on (supplemental) content—add a second oligo pool of up to 1000 targets to a previously designed TruSeq Targeted RNA Expression custom panel.
Start a Custom Project
Order custom panels using DesignStudio, a free, user-friendly, web-based tool. Simply select the assays you need and add them to your order, with no design time.
Log in to DesignStudio
Browse TruSeq Targeted RNA Sample Data
Human Brain Reference RNA (HBRR), Universal Human Reference RNA (UHRR), and human liver RNA samples were prepared using the TruSeq Targeted RNA Expression Kit.
These libraries were sequenced on the MiniSeq System using the MiniSeq High Output Reagent Kit at a 1 x 51 bp read length configuration. The total yield was 2.04 Gb with 96.5% of bases at or above Q30.
Note that access to this data requires a BaseSpace Sequence Hub login.
Register for BaseSpace Sequence Hub
View TruSeq Targeted RNA Project Data
(secondary analysis with BaseSpace Apps)
*Refers to instruments with catalog number SY-410-1001 and upgrade, or catalog number SY-410-1003
Specifications:
Assay Time 1 day
Hands-On Time 4 hours
Input Quantity 50 ng RNA,50 ng high-quality total RNA,≥ 200 ng FFPE total RNA; Recommended quantity may vary with expression level, target plexity, and sample quality
Content Specifications Choose from 400,000+ pre-designed targeted RNA-Seq assays. Or add content to a fixed panel or previously designed custom panel.
Multiplexing Up to 384 samples per sequencing run
Mechanism of Action Amplification
Method Targeted RNA Sequencing
Variant Class Single Nucleotide Polymorphisms (SNPs),Gene Fusions,Transcript Variants
Specialized Sample Types FFPE
"
"Illumina/TruSeq Small RNA Library Prep Kit -Set C (24 rxns) (Set C: indexes 25-36)/RS-200-0036/1 Ea
" Illumina 產(chǎn)品編號: RS-200-0036美 元 價: $2450.00會 員 價: 待定品 牌: Illumina產(chǎn) 地: 美國公 司: Illumina, Inc.產(chǎn)品分類: 分子類>二代測序>DNA文庫制備試劑盒公司分類: Library Preparation Kits "Product Highlights:
TruSeq Small RNA Library Preparation Kits provide reagents to generate small RNA libraries directly from total RNA. MicroRNAs (miRNAs) generated by Dicer processing are efficiently targeted by the included modified adapters.
These kits enable multiplexed sequencing with the introduction of 48 unique indexes, allowing miRNA and small RNA discovery and profiling throughput to match the unparalleled output of Illumina sequencing. Indexes are added in a universal amplification reaction, greatly reducing ligation bias and ensuring accurate measurement of miRNA expression.
Workflow improvements enable streamlined sample preparation, allowing economical studies covering all small RNA transcripts in any species. CompatIBLe applications include finding novel miRNAs, characterizing variation such as isomers with single-base resolution, and analyzing differential expression without prior assumptions.
TruSeq Small RNA Sample Datasets
The Human Brain Reference RNA (HBRR) and Universal Human Reference RNA (UHRR) samples were prepared using the TruSeq Small RNA Library Prep Kit. These libraries were sequenced on the MiniSeq System using the MiniSeq High Output Reagent Kit at a 1 x 36 bp read length configuration. The total yield was 0.91 Gb with 97% of bases at or above Q30.
Browse the Data In BaseSpace Sequence Hub:
View Run (primary analysis and metrics)
View Project (secondary analysis with BaseSpace Apps)
Specifications:
Assay Time ~10.5 hours
Hands-On Time ~30 minutes
Input Quantity 25 to 100 ng total RNA from species with polyA tails
Content Specifications Captures the coding transcriptome with strand information
Mechanism of Action Oligo-dT beads capture polyA tails
Multiplexing Up to 24-plex pooling with additional NeoPrep runs
Sample Throughput Up to 16 samples per NeoPrep library card
Species Category Drosophila,Any Species,Mouse,Zebrafish,Human,Rat,Plant,Nematode
System Compatibility MiSeq,NextSeq 550,MiniSeq,NextSeq 500
Specialized Sample Types FFPE,Low Input
Technology Sequencing
Automation CapABIlity Liquid Handling Robots
Variant Class Novel Transcripts,Transcript Variants
Method miRNA and Small RNA Sequencing"
"Illumina/TruSeq Small RNA Library Prep Kit -Set A (24 rxns) (Set A: indexes 1-12)/RS-200-0012/1 Ea
" Illumina 產(chǎn)品編號: RS-200-0012美 元 價: $2450.00會 員 價: 待定品 牌: Illumina產(chǎn) 地: 美國公 司: Illumina, Inc.產(chǎn)品分類: 分子類>二代測序>DNA文庫制備試劑盒公司分類: Library Preparation Kits "Product Highlights:
TruSeq Small RNA Library Preparation Kits provide reagents to generate small RNA libraries directly from total RNA. MicroRNAs (miRNAs) generated by Dicer processing are efficiently targeted by the included modified adapters.
These kits enable multiplexed sequencing with the introduction of 48 unique indexes, allowing miRNA and small RNA discovery and profiling throughput to match the unparalleled output of Illumina sequencing. Indexes are added in a universal amplification reaction, greatly reducing ligation bias and ensuring accurate measurement of miRNA expression.
Workflow improvements enable streamlined sample preparation, allowing economical studies covering all small RNA transcripts in any species. CompatIBLe applications include finding novel miRNAs, characterizing variation such as isomers with single-base resolution, and analyzing differential expression without prior assumptions.
TruSeq Small RNA Sample Datasets
The Human Brain Reference RNA (HBRR) and Universal Human Reference RNA (UHRR) samples were prepared using the TruSeq Small RNA Library Prep Kit. These libraries were sequenced on the MiniSeq System using the MiniSeq High Output Reagent Kit at a 1 x 36 bp read length configuration. The total yield was 0.91 Gb with 97% of bases at or above Q30.
Browse the Data In BaseSpace Sequence Hub:
View Run (primary analysis and metrics)
View Project (secondary analysis with BaseSpace Apps)
Specifications:
Assay Time ~10.5 hours
Hands-On Time ~30 minutes
Input Quantity 25 to 100 ng total RNA from species with polyA tails
Content Specifications Captures the coding transcriptome with strand information
Mechanism of Action Oligo-dT beads capture polyA tails
Multiplexing Up to 24-plex pooling with additional NeoPrep runs
Sample Throughput Up to 16 samples per NeoPrep library card
Species Category Drosophila,Any Species,Mouse,Zebrafish,Human,Rat,Plant,Nematode
System Compatibility MiSeq,NextSeq 550,MiniSeq,NextSeq 500
Specialized Sample Types FFPE,Low Input
Technology Sequencing
Automation CapABIlity Liquid Handling Robots
Variant Class Novel Transcripts,Transcript Variants
Method miRNA and Small RNA Sequencing
"
"Illumina/TruSeq Targeted RNA Index Kit C (96 indexes, 384 samples)/RT-402-1003/1 Ea
" Illumina 產(chǎn)品編號: RT-402-1003美 元 價: $1019.00會 員 價: 待定品 牌: Illumina產(chǎn) 地: 美國公 司: Illumina, Inc.產(chǎn)品分類: 分子類>二代測序>DNA文庫制備試劑盒公司分類: Library Preparation Kits "Product Highlights:
TruSeq Targeted RNA Expression Kits enable highly customizable mid- to high-plex gene expression profiling studies.
You can define panels of 12-1,000 assays to target individual exons, isoforms, splice junctions, coding SNPS (cSNPs), gene fusions, and non-coding RNA transcripts, plus multiplex up to 384 samples. Generate the data equivalent of up to 25,000 individual RT-PCR assays in a single run.*
Assays include convenient online panel design and ordering, a rapid and simple workflow starting with as little as 50 ng of RNA, and automated, on-instrument data analysis.
Types of Study Designs
Custom panels—select up to 1000 targets from a database of over 400,000 predesigned assays.
Add-on (supplemental) content—add a second oligo pool of up to 1000 targets to a previously designed TruSeq Targeted RNA Expression custom panel.
Start a Custom Project
Order custom panels using DesignStudio, a free, user-friendly, web-based tool. Simply select the assays you need and add them to your order, with no design time.
Log in to DesignStudio
Browse TruSeq Targeted RNA Sample Data
Human Brain Reference RNA (HBRR), Universal Human Reference RNA (UHRR), and human liver RNA samples were prepared using the TruSeq Targeted RNA Expression Kit.
These libraries were sequenced on the MiniSeq System using the MiniSeq High Output Reagent Kit at a 1 x 51 bp read length configuration. The total yield was 2.04 Gb with 96.5% of bases at or above Q30.
Note that access to this data requires a BaseSpace Sequence Hub login.
Register for BaseSpace Sequence Hub
View TruSeq Targeted RNA Project Data
(secondary analysis with BaseSpace Apps)
*Refers to instruments with catalog number SY-410-1001 and upgrade, or catalog number SY-410-1003
Specifications:
Assay Time 1 day
Hands-On Time 4 hours
Input Quantity 50 ng RNA,50 ng high-quality total RNA,≥ 200 ng FFPE total RNA; Recommended quantity may vary with expression level, target plexity, and sample quality
Content Specifications Choose from 400,000+ pre-designed targeted RNA-Seq assays. Or add content to a fixed panel or previously designed custom panel.
Multiplexing Up to 384 samples per sequencing run
Mechanism of Action Amplification
Method Targeted RNA Sequencing
Variant Class Single Nucleotide Polymorphisms (SNPs),Gene Fusions,Transcript Variants
Specialized Sample Types FFPE
"
"Illumina/TruSeq DNA Methylation Kit (96 reactions)/EGMK91396/1 Ea
" Illumina 產(chǎn)品編號: EGMK91396美 元 價: $5567.00會 員 價: 待定品 牌: Illumina產(chǎn) 地: 美國公 司: Illumina, Inc.產(chǎn)品分類: 分子類>二代測序>DNA文庫制備試劑盒公司分類: Library Preparation Kits "Product Highlights:
Unlock small samples (50–100 ng DNA input)
CpG, CHH, & CHG regions included for comprehensive, whole-genome results
Fast protocol – five-hour method
Capture full sample diversity
Sequence the entire sample–no loss of information
The process of bisulfite treatment denatures genomic DNA into single stranded DNA. TruSeq DNA Methylation converts single stranded DNA into an Illumina sequencing library. All ssDNA fragments are captured into an Illumina sequencing library, therefore eliminating the loss of diversity associated with other methods.
Supported analysis in the cloud
TruSeq DNA Methylation libraries can be aligned to the human genome and compared for differential methylation with Illumina BaseSpace Apps MethylSeq and MethylKit. These applications are fully supported and were developed specifically for TruSeq DNA Methylation library preparation.
Example data sets for TruSeq DNA Methylation libraries, also available in BaseSpace Sequence Hub Data Central (use the “Methyl Seq” category filter), demonstrate unparalleled quality and seamless analysis.
Deep coverage of critical genomic regions
Depth of coverage is enhanced in genomic areas with BIOLOGical utility. TruSeq DNA Methylation captures full sample diversity of critical areas, including:
Coding region start and end for exons from the canonical transcript of protein coding genes for genes known to be involved in cancer, taken from SOMA and CRUK panels (as well as literature-derived cancer genes)
Genes defined by the American College of Medical Genetics as being medically relevant (ACMG genes)
Exonic coding regions from Ensemble 70
List of 100 promoters defined by the Broad Institute as being of high interest and difficult to sequence"
"Illumina/TruSeq Targeted RNA Index Kit (48 indexes, 48 samples)/RT-401-1001/1 Ea
" Illumina 產(chǎn)品編號: RT-401-1001美 元 價: $698.00會 員 價: 待定品 牌: Illumina產(chǎn) 地: 美國公 司: Illumina, Inc.產(chǎn)品分類: 分子類>二代測序>DNA文庫制備試劑盒公司分類: Library Preparation Kits "Product Highlights:
TruSeq Targeted RNA Expression Kits enable highly customizable mid- to high-plex gene expression profiling studies.
You can define panels of 12-1,000 assays to target individual exons, isoforms, splice junctions, coding SNPS (cSNPs), gene fusions, and non-coding RNA transcripts, plus multiplex up to 384 samples. Generate the data equivalent of up to 25,000 individual RT-PCR assays in a single run.*
Assays include convenient online panel design and ordering, a rapid and simple workflow starting with as little as 50 ng of RNA, and automated, on-instrument data analysis.
Types of Study Designs
Custom panels—select up to 1000 targets from a database of over 400,000 predesigned assays.
Add-on (supplemental) content—add a second oligo pool of up to 1000 targets to a previously designed TruSeq Targeted RNA Expression custom panel.
Start a Custom Project
Order custom panels using DesignStudio, a free, user-friendly, web-based tool. Simply select the assays you need and add them to your order, with no design time.
Log in to DesignStudio
Browse TruSeq Targeted RNA Sample Data
Human Brain Reference RNA (HBRR), Universal Human Reference RNA (UHRR), and human liver RNA samples were prepared using the TruSeq Targeted RNA Expression Kit.
These libraries were sequenced on the MiniSeq System using the MiniSeq High Output Reagent Kit at a 1 x 51 bp read length configuration. The total yield was 2.04 Gb with 96.5% of bases at or above Q30.
Note that access to this data requires a BaseSpace Sequence Hub login.
Register for BaseSpace Sequence Hub
View TruSeq Targeted RNA Project Data
(secondary analysis with BaseSpace Apps)
*Refers to instruments with catalog number SY-410-1001 and upgrade, or catalog number SY-410-1003
Specifications:
Assay Time 1 day
Hands-On Time 4 hours
Input Quantity 50 ng RNA,50 ng high-quality total RNA,≥ 200 ng FFPE total RNA; Recommended quantity may vary with expression level, target plexity, and sample quality
Content Specifications Choose from 400,000+ pre-designed targeted RNA-Seq assays. Or add content to a fixed panel or previously designed custom panel.
Multiplexing Up to 384 samples per sequencing run
Mechanism of Action Amplification
Method Targeted RNA Sequencing
Variant Class Single Nucleotide Polymorphisms (SNPs),Gene Fusions,Transcript Variants
Specialized Sample Types FFPE
"
"Illumina/TruSeq DNA Methylation Kit (24 reactions)/EGMK91324/1 Ea
" Illumina 產(chǎn)品編號: EGMK91324美 元 價: $1787.00會 員 價: 待定品 牌: Illumina產(chǎn) 地: 美國公 司: Illumina, Inc.產(chǎn)品分類: 分子類>二代測序>DNA文庫制備試劑盒公司分類: Library Preparation Kits "Product Highlights:
Unlock small samples (50–100 ng DNA input)
CpG, CHH, & CHG regions included for comprehensive, whole-genome results
Fast protocol – five-hour method
Capture full sample diversity
Sequence the entire sample–no loss of information
The process of bisulfite treatment denatures genomic DNA into single stranded DNA. TruSeq DNA Methylation converts single stranded DNA into an Illumina sequencing library. All ssDNA fragments are captured into an Illumina sequencing library, therefore eliminating the loss of diversity associated with other methods.
Supported analysis in the cloud
TruSeq DNA Methylation libraries can be aligned to the human genome and compared for differential methylation with Illumina BaseSpace Apps MethylSeq and MethylKit. These applications are fully supported and were developed specifically for TruSeq DNA Methylation library preparation.
Example data sets for TruSeq DNA Methylation libraries, also available in BaseSpace Sequence Hub Data Central (use the “Methyl Seq” category filter), demonstrate unparalleled quality and seamless analysis.
Deep coverage of critical genomic regions
Depth of coverage is enhanced in genomic areas with BIOLOGical utility. TruSeq DNA Methylation captures full sample diversity of critical areas, including:
Coding region start and end for exons from the canonical transcript of protein coding genes for genes known to be involved in cancer, taken from SOMA and CRUK panels (as well as literature-derived cancer genes)
Genes defined by the American College of Medical Genetics as being medically relevant (ACMG genes)
Exonic coding regions from Ensemble 70
List of 100 promoters defined by the Broad Institute as being of high interest and difficult to sequence"
"Illumina/TruSeq Small RNA Set D MiniSeq Kit (1 library prep and 2 MiniSeq reagents)/20005616/1 Ea
" Illumina 產(chǎn)品編號: 20005616美 元 價: $3200.00會 員 價: 待定品 牌: Illumina產(chǎn) 地: 美國公 司: Illumina, Inc.產(chǎn)品分類: 分子類>二代測序>DNA文庫制備試劑盒公司分類: Library Preparation Kits "Product Highlights:
TruSeq Small RNA Library Preparation Kits provide reagents to generate small RNA libraries directly from total RNA. MicroRNAs (miRNAs) generated by Dicer processing are efficiently targeted by the included modified adapters.
These kits enable multiplexed sequencing with the introduction of 48 unique indexes, allowing miRNA and small RNA discovery and profiling throughput to match the unparalleled output of Illumina sequencing. Indexes are added in a universal amplification reaction, greatly reducing ligation bias and ensuring accurate measurement of miRNA expression.
Workflow improvements enable streamlined sample preparation, allowing economical studies covering all small RNA transcripts in any species. CompatIBLe applications include finding novel miRNAs, characterizing variation such as isomers with single-base resolution, and analyzing differential expression without prior assumptions.
TruSeq Small RNA Sample Datasets
The Human Brain Reference RNA (HBRR) and Universal Human Reference RNA (UHRR) samples were prepared using the TruSeq Small RNA Library Prep Kit. These libraries were sequenced on the MiniSeq System using the MiniSeq High Output Reagent Kit at a 1 x 36 bp read length configuration. The total yield was 0.91 Gb with 97% of bases at or above Q30.
Browse the Data In BaseSpace Sequence Hub:
View Run (primary analysis and metrics)
View Project (secondary analysis with BaseSpace Apps)
Specifications:
Assay Time ~10.5 hours
Hands-On Time ~30 minutes
Input Quantity 25 to 100 ng total RNA from species with polyA tails
Content Specifications Captures the coding transcriptome with strand information
Mechanism of Action Oligo-dT beads capture polyA tails
Multiplexing Up to 24-plex pooling with additional NeoPrep runs
Sample Throughput Up to 16 samples per NeoPrep library card
Species Category Drosophila,Any Species,Mouse,Zebrafish,Human,Rat,Plant,Nematode
System Compatibility MiSeq,NextSeq 550,MiniSeq,NextSeq 500
Specialized Sample Types FFPE,Low Input
Technology Sequencing
Automation CapABIlity Liquid Handling Robots
Variant Class Novel Transcripts,Transcript Variants
Method miRNA and Small RNA Sequencing
"
"Illumina/TruSeq DNA Methylation Index PCR Primers (10 reactions, 12 indexes)/EGIDX81312/1 Ea
" Illumina 產(chǎn)品編號: EGIDX81312美 元 價: $78.00會 員 價: 待定品 牌: Illumina產(chǎn) 地: 美國公 司: Illumina, Inc.產(chǎn)品分類: 分子類>二代測序>DNA文庫制備試劑盒公司分類: Library Preparation Kits "Product Highlights:
Unlock small samples (50–100 ng DNA input)
CpG, CHH, & CHG regions included for comprehensive, whole-genome results
Fast protocol – five-hour method
Capture full sample diversity
Sequence the entire sample–no loss of information
The process of bisulfite treatment denatures genomic DNA into single stranded DNA. TruSeq DNA Methylation converts single stranded DNA into an Illumina sequencing library. All ssDNA fragments are captured into an Illumina sequencing library, therefore eliminating the loss of diversity associated with other methods.
Supported analysis in the cloud
TruSeq DNA Methylation libraries can be aligned to the human genome and compared for differential methylation with Illumina BaseSpace Apps MethylSeq and MethylKit. These applications are fully supported and were developed specifically for TruSeq DNA Methylation library preparation.
Example data sets for TruSeq DNA Methylation libraries, also available in BaseSpace Sequence Hub Data Central (use the “Methyl Seq” category filter), demonstrate unparalleled quality and seamless analysis.
Deep coverage of critical genomic regions
Depth of coverage is enhanced in genomic areas with BIOLOGical utility. TruSeq DNA Methylation captures full sample diversity of critical areas, including:
Coding region start and end for exons from the canonical transcript of protein coding genes for genes known to be involved in cancer, taken from SOMA and CRUK panels (as well as literature-derived cancer genes)
Genes defined by the American College of Medical Genetics as being medically relevant (ACMG genes)
Exonic coding regions from Ensemble 70
List of 100 promoters defined by the Broad Institute as being of high interest and difficult to sequence"
"Illumina/TruSeq Bovine Parentage Kit (96 indexes, 96 samples)/20004795/1 Ea
" Illumina 產(chǎn)品編號: 20004795美 元 價: $960.00會 員 價: 待定品 牌: Illumina產(chǎn) 地: 美國公 司: Illumina, Inc.產(chǎn)品分類: 分子類>二代測序>DNA文庫制備試劑盒公司分類: Library Preparation Kits "Product Highlights:
This solution for parentage testing of multiple beef and dairy cattle breeds has added genotyping of relevant traits. By offering more information in a single assay than from parentage testing alone, service labs can use the TruSeq Bovine Parentage Sequencing Panel to make more informed herd management recommendations.
Includes all International Society of Animal Genetics (ISAG) recommended content, plus disease-associated and economically relevant traits
Content design, high accuracy, and reliABIlity eliminate need for multiple or repeat testing
Analysis software converts sequencing results to genotype calls without the need for bioinformatics expertise
The TruSeq Bovine Parentage Sequencing Panel uses proven Illumina next-generation sequencing (NGS) technology to deliver accurate genotyping results for SNP-based parentage determination in cattle. The high accuracy and reliABIlity of Illumina sequencing reduces the amount of required testing and shortens the time to answer, leADIng to efficiency gains and cost savings. It features a streamlined workflow that goes from DNA to report in 1.5 days with minimal hands-on time.
Have confidence that the typing result is accurate, the first time. TruSeq Bovine Parentage has been tested with multiple breeds, DNA inputs, and extraction methods. It provides deep sequencing coverage across SNPs.
Specifications:
Input Quantity ≤ 1 ng genomic DNA, or 2 ul crude lysates, or 1.2 mm FTA card punch
Hands-On Time ~1 hour
Assay Time 9 hours
Mechanism of Action PCR
Multiplexing Maximum of 32 casework samples or 96 database or reference samples
System Compatibility MiSeq
Variant Class Single Nucleotide Polymorphisms (SNPs)
Species Category Bovine
Technology Sequencing
Method Genotyping by Sequencing,Amplicon Sequencing,Targeted DNA Sequencing"
"Illumina/TruSeq Ribo Profile for Mammalian (12 reactions, 12 indexes)/RPHMR12126/1 Ea
" Illumina 產(chǎn)品編號: RPHMR12126美 元 價: $1575.00會 員 價: 待定品 牌: Illumina產(chǎn) 地: 美國公 司: Illumina, Inc.產(chǎn)品分類: 分子類>二代測序>DNA文庫制備試劑盒公司分類: Library Preparation Kits "Product Highlights:
Study active mRNA translation with sequencing
Sequence ribosome-protected mRNA
Predict protein abundance
Investigate translational control
Measure gene expression
Rapid, scalable spin-column method
No ultracentrifuge required
CompatIBLe with yeast and mammalian samples
Sequence actively translated transcripts
Ribosome profiling is a technique for investigating translational control that provides a snapshot of all the ribosomes active in a cell at a specific time. TruSeq Ribo Profile generates RNA-Seq libraries from ribosome-protected fragments of mRNAs that are actively being translated.
Use TruSeq Ribo Profile to sequence mRNA fragments undergoing translation by ribosomes. These mRNA fragments are called ""footprinted"" or ribosome-protected mRNA fragments.
You can also identify proteins being actively translated from samples prepared with TruSeq Ribo Profile. Samples collected at different times often show changes in translation. Samples treated with different drugs often show different translation patterns.
Specifications:
Input Quantity 0.1 – 1 ug high-quality purified total RNA from blood
Content Specifications Captures coding RNA plus multiple forms of non-coding RNA
Mechanism of Action Bead-based rRNA depletion, CDNA synthesis, and PCR
Multiplexing Low-throughput kits: Pool up to 12 samples. Or pool up to 24 samples with sets A and B together,High-throughput kit version: Prepare 96 uniquely indexed samples
System Compatibility NovaSeq 5000,Genome Analyzer IIx,HiSeq 2000,NextSeq 500,HiSeq 2500
Automation CapABIlity Liquid Handling Robots
Variant Class Transcript Variants
Species Category Rat"
"Illumina/TruSeq Small RNA Library Prep Kit -Set D (24 rxns) (Set D: indices 37-48)/RS-200-0048/1 Ea
" Illumina 產(chǎn)品編號: RS-200-0048美 元 價: $2450.00會 員 價: 待定品 牌: Illumina產(chǎn) 地: 美國公 司: Illumina, Inc.產(chǎn)品分類: 分子類>二代測序>DNA文庫制備試劑盒公司分類: Library Preparation Kits "Product Highlights:
TruSeq Small RNA Library Preparation Kits provide reagents to generate small RNA libraries directly from total RNA. MicroRNAs (miRNAs) generated by Dicer processing are efficiently targeted by the included modified adapters.
These kits enable multiplexed sequencing with the introduction of 48 unique indexes, allowing miRNA and small RNA discovery and profiling throughput to match the unparalleled output of Illumina sequencing. Indexes are added in a universal amplification reaction, greatly reducing ligation bias and ensuring accurate measurement of miRNA expression.
Workflow improvements enable streamlined sample preparation, allowing economical studies covering all small RNA transcripts in any species. CompatIBLe applications include finding novel miRNAs, characterizing variation such as isomers with single-base resolution, and analyzing differential expression without prior assumptions.
TruSeq Small RNA Sample Datasets
The Human Brain Reference RNA (HBRR) and Universal Human Reference RNA (UHRR) samples were prepared using the TruSeq Small RNA Library Prep Kit. These libraries were sequenced on the MiniSeq System using the MiniSeq High Output Reagent Kit at a 1 x 36 bp read length configuration. The total yield was 0.91 Gb with 97% of bases at or above Q30.
Browse the Data In BaseSpace Sequence Hub:
View Run (primary analysis and metrics)
View Project (secondary analysis with BaseSpace Apps)
Specifications:
Assay Time ~10.5 hours
Hands-On Time ~30 minutes
Input Quantity 25 to 100 ng total RNA from species with polyA tails
Content Specifications Captures the coding transcriptome with strand information
Mechanism of Action Oligo-dT beads capture polyA tails
Multiplexing Up to 24-plex pooling with additional NeoPrep runs
Sample Throughput Up to 16 samples per NeoPrep library card
Species Category Drosophila,Any Species,Mouse,Zebrafish,Human,Rat,Plant,Nematode
System Compatibility MiSeq,NextSeq 550,MiniSeq,NextSeq 500
Specialized Sample Types FFPE,Low Input
Technology Sequencing
Automation CapABIlity Liquid Handling Robots
Variant Class Novel Transcripts,Transcript Variants
Method miRNA and Small RNA Sequencing
"
"Illumina/TruSeq Ribo Profile for Yeast (12 reactions, 12 indexes)/RPYSC12116/1 Ea
" Illumina 產(chǎn)品編號: RPYSC12116美 元 價: $1575.00會 員 價: 待定品 牌: Illumina產(chǎn) 地: 美國公 司: Illumina, Inc.產(chǎn)品分類: 分子類>二代測序>DNA文庫制備試劑盒公司分類: Library Preparation Kits "Product Highlights:
Study active mRNA translation with sequencing
Sequence ribosome-protected mRNA
Predict protein abundance
Investigate translational control
Measure gene expression
Rapid, scalable spin-column method
No ultracentrifuge required
CompatIBLe with yeast and mammalian samples
Sequence actively translated transcripts
Ribosome profiling is a technique for investigating translational control that provides a snapshot of all the ribosomes active in a cell at a specific time. TruSeq Ribo Profile generates RNA-Seq libraries from ribosome-protected fragments of mRNAs that are actively being translated.
Use TruSeq Ribo Profile to sequence mRNA fragments undergoing translation by ribosomes. These mRNA fragments are called ""footprinted"" or ribosome-protected mRNA fragments.
You can also identify proteins being actively translated from samples prepared with TruSeq Ribo Profile. Samples collected at different times often show changes in translation. Samples treated with different drugs often show different translation patterns.
Specifications:
Input Quantity 0.1 – 1 ug high-quality purified total RNA from blood
Content Specifications Captures coding RNA plus multiple forms of non-coding RNA
Mechanism of Action Bead-based rRNA depletion, CDNA synthesis, and PCR
Multiplexing Low-throughput kits: Pool up to 12 samples. Or pool up to 24 samples with sets A and B together,High-throughput kit version: Prepare 96 uniquely indexed samples
System Compatibility NovaSeq 5000,Genome Analyzer IIx,HiSeq 2000,NextSeq 500,HiSeq 2500
Automation CapABIlity Liquid Handling Robots
Variant Class Transcript Variants
Species Category Rat
"
"Illumina/TruSeq Targeted RNA Index Kit B (96 indexes, 384 samples)/RT-402-1002/1 Ea
" Illumina 產(chǎn)品編號: RT-402-1002美 元 價: $1019.00會 員 價: 待定品 牌: Illumina產(chǎn) 地: 美國公 司: Illumina, Inc.產(chǎn)品分類: 分子類>二代測序>DNA文庫制備試劑盒公司分類: Library Preparation Kits "Product Highlights:
TruSeq Targeted RNA Expression Kits enable highly customizable mid- to high-plex gene expression profiling studies.
You can define panels of 12-1,000 assays to target individual exons, isoforms, splice junctions, coding SNPS (cSNPs), gene fusions, and non-coding RNA transcripts, plus multiplex up to 384 samples. Generate the data equivalent of up to 25,000 individual RT-PCR assays in a single run.*
Assays include convenient online panel design and ordering, a rapid and simple workflow starting with as little as 50 ng of RNA, and automated, on-instrument data analysis.
Types of Study Designs
Custom panels—select up to 1000 targets from a database of over 400,000 predesigned assays.
Add-on (supplemental) content—add a second oligo pool of up to 1000 targets to a previously designed TruSeq Targeted RNA Expression custom panel.
Start a Custom Project
Order custom panels using DesignStudio, a free, user-friendly, web-based tool. Simply select the assays you need and add them to your order, with no design time.
Log in to DesignStudio
Browse TruSeq Targeted RNA Sample Data
Human Brain Reference RNA (HBRR), Universal Human Reference RNA (UHRR), and human liver RNA samples were prepared using the TruSeq Targeted RNA Expression Kit.
These libraries were sequenced on the MiniSeq System using the MiniSeq High Output Reagent Kit at a 1 x 51 bp read length configuration. The total yield was 2.04 Gb with 96.5% of bases at or above Q30.
Note that access to this data requires a BaseSpace Sequence Hub login.
Register for BaseSpace Sequence Hub
View TruSeq Targeted RNA Project Data
(secondary analysis with BaseSpace Apps)
*Refers to instruments with catalog number SY-410-1001 and upgrade, or catalog number SY-410-1003
Specifications:
Assay Time 1 day
Hands-On Time 4 hours
Input Quantity 50 ng RNA,50 ng high-quality total RNA,≥ 200 ng FFPE total RNA; Recommended quantity may vary with expression level, target plexity, and sample quality
Content Specifications Choose from 400,000+ pre-designed targeted RNA-Seq assays. Or add content to a fixed panel or previously designed custom panel.
Multiplexing Up to 384 samples per sequencing run
Mechanism of Action Amplification
Method Targeted RNA Sequencing
Variant Class Single Nucleotide Polymorphisms (SNPs),Gene Fusions,Transcript Variants
Specialized Sample Types FFPE
"
"Illumina/HiSeq Rapid Duo cBot Sample Loading Kit/CT-403-2001/1 Ea
" Illumina 產(chǎn)品編號: CT-403-2001美 元 價: $440.00會 員 價: 待定品 牌: Illumina產(chǎn) 地: 美國公 司: Illumina, Inc.產(chǎn)品分類: 分子類>二代測序>簇生成和測序試劑公司分類: Cluster Generation & Sequencing Reagents "Product Highlights:
The HiSeq Rapid Duo cBot Sample LoADIng Kit allows maximum indexing freedom in rapid run mode by enabling individually addressable lanes. This kit is an optional accessory for HiSeq Rapid Cluster kits (which require a cBot instrument), and is designed for use in the rapid run workflow of HiSeq 2500 and 1500 sequencers.
Load each flow cell lane independently
Maximize indexing possibilities
Separate precious samples physically
Load different samples in each lane
The HiSeq Rapid Duo cBot Sample LoADIng Kit allows each rapid flow cell lane to be loaded with a unique sample template pool. The duo kit accomplishes individual lane loADIng by allowing a cBot instrument to be used for the template hybridization and first extension steps of the cluster generation process. To use the cBot to load 2 libraries onto a rapid flow cell, 1 HiSeq Rapid Duo cBot Sample LoADIng Kit is required. Each kit contains sufficient reagents for loADIng 1 flow cell.
A specifically designed duo manifold directs each of the 2 samples into the 2 separate rapid flow cell lanes. The cBot portion takes about an hour, after which the flow cell is moved to the HiSeq 2500 or 1500 for further cluster generation steps using a HiSeq Rapid Cluster Kit."
"Illumina/PhiX Control v3/FC-110-3001/1 Ea
" Illumina "產(chǎn)品編號: FC-110-3001美 元 價: $160.00會 員 價: 待定品 牌: Illumina產(chǎn) 地: 美國公 司: Illumina, Inc.產(chǎn)品分類: 分子類>二代測序>簇生成和測序試劑公司分類: Cluster Generation & Sequencing Reagents
Size: 1 Ea" "Product Highlights:
PhiX Control v3 is a reliable, adapter-ligated library used as a control for Illumina sequencing runs. The library is derived from the small, well-characterized PhiX genome, offering several benefits for sequencing and alignment.
The versatile PhiX Control v3 is provided as a ready-to-use library, and can be utilized in diverse applications to add value to your workflow and increase confidence in your results.
The PhiX library provides a quality control for cluster generation, sequencing, and alignment, and a calibration control for cross-talk matrix generation, phasing, and prephasing. It can be rapidly aligned to estimate relevant sequencing by synthesis (SBS) metrics such as phasing and error rate.
Depending on the application, PhiX Control v3 may also be utilized:
As a high-concentration spike-in control for unbalanced samples (genomes with AT or GC content of less than 40% or greater than 60%)
As a low-concentration spike-in control for alignment calculations and quantification efficiency
As a dedicated control lane alongside low-diversity samples
As a control for troubleshooting cluster generation problems, to help determine whether an error is related to library preparation
Specifications:
System Compatibility MiSeq,Genome Analyzer IIx,HiSeq 2000,HiSeq X Ten,HiScanSQ,NextSeq 550,HiSeq 3000,HiSeq X Five,HiSeq 1000,MiSeqDx in Research Mode,MiniSeq,HiSeq 1500,NextSeq 500,MiSeq FGx in Research Mode,HiSeq 2500,NovaSeq 6000,HiSeq 4000
Reagent Type Sequencing Control
Technology Sequencing"
"Illumina/TruSeq Small RNA Set A MiniSeq Kit (1 library prep and 2 MiniSeq reagents)/20005613/1 Ea
" Illumina 產(chǎn)品編號: 20005613美 元 價: $3200.00會 員 價: 待定品 牌: Illumina產(chǎn) 地: 美國公 司: Illumina, Inc.產(chǎn)品分類: 分子類>二代測序>DNA文庫制備試劑盒公司分類: Library Preparation Kits "Product Highlights:
TruSeq Small RNA Library Preparation Kits provide reagents to generate small RNA libraries directly from total RNA. MicroRNAs (miRNAs) generated by Dicer processing are efficiently targeted by the included modified adapters.
These kits enable multiplexed sequencing with the introduction of 48 unique indexes, allowing miRNA and small RNA discovery and profiling throughput to match the unparalleled output of Illumina sequencing. Indexes are added in a universal amplification reaction, greatly reducing ligation bias and ensuring accurate measurement of miRNA expression.
Workflow improvements enable streamlined sample preparation, allowing economical studies covering all small RNA transcripts in any species. CompatIBLe applications include finding novel miRNAs, characterizing variation such as isomers with single-base resolution, and analyzing differential expression without prior assumptions.
TruSeq Small RNA Sample Datasets
The Human Brain Reference RNA (HBRR) and Universal Human Reference RNA (UHRR) samples were prepared using the TruSeq Small RNA Library Prep Kit. These libraries were sequenced on the MiniSeq System using the MiniSeq High Output Reagent Kit at a 1 x 36 bp read length configuration. The total yield was 0.91 Gb with 97% of bases at or above Q30.
Browse the Data In BaseSpace Sequence Hub:
View Run (primary analysis and metrics)
View Project (secondary analysis with BaseSpace Apps)
Specifications:
Assay Time ~10.5 hours
Hands-On Time ~30 minutes
Input Quantity 25 to 100 ng total RNA from species with polyA tails
Content Specifications Captures the coding transcriptome with strand information
Mechanism of Action Oligo-dT beads capture polyA tails
Multiplexing Up to 24-plex pooling with additional NeoPrep runs
Sample Throughput Up to 16 samples per NeoPrep library card
Species Category Drosophila,Any Species,Mouse,Zebrafish,Human,Rat,Plant,Nematode
System Compatibility MiSeq,NextSeq 550,MiniSeq,NextSeq 500
Specialized Sample Types FFPE,Low Input
Technology Sequencing
Automation CapABIlity Liquid Handling Robots
Variant Class Novel Transcripts,Transcript Variants
Method miRNA and Small RNA Sequencing"
illumina 15073345 Streck cell free DNA BCT CE
illumina 20000215 TruSight HLA v2 Sequencing Panel (24 samples)
illumina 20000766 BovineSNP50-24 v3 BeadChip (48 samples)
illumina 20000767 BovineSNP50-24 v3 BeadChip (288 samples)
illumina 20000768 Infinium® BovineSNP50-24 v3.0 BeadChip Kit (1152 samples)
illumina 20001090 Infinium Multi-Ethnic AMR/AFR-8 v1.0 Kit (16 samples)
illumina 20001091 Infinium Multi-Ethnic AMR/AFR-8 v1.0 Kit (48 samples)
illumina 20001092 Infinium Multi-Ethnic AMR/AFR-8 v1.0 Kit (96 samples)
illumina 20001093 Infinium Multi-Ethnic AMR/AFR-8 v1.0 Kit (384 samples)
illumina 20001100 Infinium Multi-Ethnic EUR/EAS/SAS-8 v1.0 Kit (16 samples)
illumina 20001101 Infinium Multi-Ethnic EUR/EAS/SAS-8 v1.0 Kit (48 samples)
illumina 20001102 Infinium Multi-Ethnic EUR/EAS/SAS-8 v1.0 Kit (96 samples)
illumina 20001103 Infinium Multi-Ethnic EUR/EAS/SAS-8 v1.0 Kit (384 samples)
illumina 20001112 Infinium Omni2.5-8 v1.3 Kit (16 samples)
illumina 20001113 Infinium Omni2.5-8 v1.3 Kit (48 samples)
illumina 20001114 Infinium Omni2.5-8 v1.3 Kit (96 samples)
illumina 20001115 Infinium Omni2.5-8 v1.3 Kit (384 samples)
illumina 20001122 Infinium OmniExpress-24 v1.2Kit (48 samples)
illumina 20001123 Infinium OmniExpress-24 v1.2Kit (288 samples)
illumina 20001124 Infinium OmniExpress-24 v1.2Kit (1152 samples)
illumina 20001332 BaseSpace HT Onsite Sequence Hub
illumina 20001333 BaseSpace HT Onsite Sequence Hub (2X)
illumina 20001334 BaseSpace HT Onsite Seq Hub (3X+Rack)
illumina 20001335 BaseSpace HT Onsite Sequence Hub (4X+rack)-Annual Software License
illumina 20003583 Infinium Omni2.5Exome-8 v1.3 Kit (16 samples)
illumina 20003606 Infinium Omni2.5Exome-8 v1.3 Kit (48 samples)
illumina 20003607 Infinium Omni2.5Exome-8 v1.3 Kit (96 samples)
illumina 20003608 Infinium Omni2.5Exome-8 v1.3 Kit (384 samples)
illumina 20004136 MiniSeq Operational Qualification
illumina 20004138 MiniSeq Installation and Operational Qualification
illumina 20004207 Infinium OmniExpressExome-8 v1.4 Kit (16 samples)
illumina 20004208 Infinium OmniExpressExome-8 v1.4 Kit (48 samples)
illumina 20004209 Infinium OmniExpressExome-8 v1.4 Kit (96 samples)
illumina 20004330 Infinium OmniExpressExome-8 v1.4 Kit (384 samples)
illumina 20004337 Infinium OmniZhongHua-8 v1.3 Kit (16 samples)
illumina 20004338 Infinium OmniZhongHua-8 v1.3 Kit (48 samples)
illumina 20004339 Infinium OmniZhongHua-8 v1.3 Kit (96 samples)
illumina 20004340 Infinium OmniZhongHua-8 v1.3 Kit (384 samples)
illumina 20004347 Infinium QC Array-24 v1.0 Kit (48 samples)
illumina 20004348 Infinium QC Array-24 v1.0 Kit (288 samples)
illumina 20004349 Infinium QC Array-24 v1.0 Kit (1152 samples)
illumina 20004359 TruSeq® Custom Amplicon Low Input INCa Consortium
illumina 20004470 BRCA DNA Repair Panel - TSCA LI (16 samples)
illumina 20004545 MiniSeq Performance Qualification
illumina 20004795 TruSeq Bovine Parentage Kit (96 indexes, 96 samples)
illumina 20005132 Infinium® Global Screening Array-24 v1.0 Kit (48 samples)
illumina 20005133 Infinium® Global Screening Array-24 v1.0 Kit (288 samples)
illumina 20005134 Infinium® Global Screening Array-24 v1.0 Kit (1152 samples)
illumina 20005140 Infinium® Omni5Exome-4 v1.3 Kit (16 samples)
illumina 20005141 Infinium® Omni5Exome-4 v1.3 Kit (48 samples)
illumina 20005142 Infinium® Omni5Exome-4 v1.3 Kit (96 samples)
illumina 20005143 Infinium® Omni5Exome-4 v1.3 Kit (384 samples)
illumina 20005150 Infinium® Omni5-4 v1.2 Kit (16 samples)
illumina 20005151 Infinium® Omni5-4 v1.2 Kit (48 samples)
illumina 20005152 Infinium® Omni5-4 v1.2 Kit (96 samples)
illumina 20005153 Infinium® Omni5-4 v1.2 Kit (384 samples)
illumina 20005160 cBot 2 Barcoded Strip Tubes
illumina 20005170 TruSight HLA v2 Sequencing Panel (24 samples, automated)
illumina 20005395 GGP BovineLD-24 v3.0 Kit (48 samples)
illumina 20005396 GGP BovineLD-24 v3.0 Kit (288 samples)
illumina 20005397 GGP BovineLD-24 v3.0 Kit (1152 samples)
illumina 20005398 GGP BovineLD-24 v4.0 Kit (48 samples)
illumina 20005399 GGP BovineLD-24 v4.0 Kit (288 samples)
illumina 20005460 GGP BovineLD-24 v4.0 Kit (1152 samples)
illumina 20005461 GGP PorcineLD-24 Kit (48 samples)
illumina 20005462 GGP PorcineLD-24 Kit (288 samples)
illumina 20005463 GGP PorcineLD-24 Kit (1152 samples)
illumina 20005464 GGP Bovine 150K-24 Kit (48 samples)
illumina 20005465 GGP Bovine 150K-24 Kit (288 samples)
illumina 20005466 GGP Bovine 150K-24 Kit (1152 samples)
illumina 20005467 GGP Bos IndicusHD-24 Kit (48 samples)
illumina 20005468 GGP Bos IndicusHD-24 Kit (288 samples)
illumina 20005469 GGP Bos IndicusHD-24 Kit (1152 samples)
illumina 20005470 GGP PorcineHD-24 Kit (48 samples)
illumina 20005471 GGP PorcineHD-24 Kit (288 samples)
illumina 20005472 GGP PorcineHD-24 Kit (1152 samples)
illumina 20005473 GGP GIGA-MUGA-24 Kit (48 samples)
illumina 20005474 GGP GIGA-MUGA-24 Kit (288 samples)
illumina 20005475 GGP GIGA-MUGA-24 Kit (1152 samples)
illumina 20005476 GGP Equine-24 Kit (48 samples)
illumina 20005477 GGP Equine-24 Kit (288 samples)
illumina 20005478 GGP Equine-24 Kit (1152 samples)
illumina 20005610 TruSight Tumor 15 MiniSeq Kit
illumina 20005611 TruSight RNA Pan-Cancer Set A MiniSeq Kit
illumina 20005612 TruSight Cancer MiniSeq Kit
illumina 20005613 TruSeq Small RNA Set A MiniSeq Kit (1 library prep and 2 MiniSeq reagents)
illumina 20005614 TruSeq Small RNA Set B MiniSeq Kit (1 library prep and 2 MiniSeq reagents)
illumina 20005615 TruSeq Small RNA Set C MiniSeq Kit (1 library prep and 2 MiniSeq reagents)
illumina 20005616 TruSeq Small RNA Set D MiniSeq Kit (1 library prep and 2 MiniSeq reagents)
illumina 20005636 BRCA DNA Repair Panel - TSCA LI (96 samples)
illumina 20005718 TruSeq® Custom Amplicon Kit Dx
illumina 20006259 TruSeq® Custom Amplicon Dx – FFPE QC
illumina 20006996 Illumina® Certified Pre-Owned NextSeq® 500 System
illumina 20007420 Infinium® XT Assay PB20 Kit
illumina 20007795 GGP Potato-24 v1.0 Kit (48 samples)
illumina 20007796 GGP Potato-24 v1.0 Kit (288 samples)
illumina 20007797 GGP Potato-24 v1.0 Kit (1152 samples)
illumina 20010179 TruSight HLA-B Primers v2
illumina 20010184 TruSight® Oncology Library Prep
illumina 20010185 TruSight Oncology DNA Library Prep
illumina 20010186 TruSight® Oncology RNA Library Prep
illumina 20010187 TruSight® Oncology Enrichment
illumina 20010188 TruSight® Tumor 170 Content Set
illumina 20010190 TruSight HLA-DRB Primers v2
illumina 20011069 Infinium XT Starter Kit (48 BeadChip batches)
illumina 20011100 Infinium® XT Starter Kit (24 Beadchips)
illumina 20011101 Infinium® XT Upgrade Kit (24 Beadchips)
illumina 20011102 Infinium® 96-XT Tip Guide Set
illumina 20011754 Infinium® Glass Back Plate Rack
illumina 20011756 XCG Glass Back Plate (8)
illumina 20011757 Infinium Te-Flow Chamber Frames (8)
illumina 20011758 Infinium Te-Flow Chamber Clamps (16)
illumina 20011759 XT Dual Hyb Insert and Baseplate
illumina 20011760 XT Flow-Through Chamber Assembly Tray
illumina 20012126 Infinium® XT HT Workflow Training Kit, Reagents Only
illumina 20012127 XT Hyb Chamber Gasket
illumina 20012552 MiSeq® Dx Reagent Kit v3
illumina 20012860 NovaSeq 6000 S2 Reagent Kit (300 cycles)
illumina 20012861 NovaSeq 6000 S2 Reagent Kit (200 cycles)
illumina 20012862 NovaSeq 6000 S2 Reagent Kit (100 cycles)
illumina 20012863 NovaSeq 6000 S1 Reagent Kit (300 cycles)
illumina 20012864 NovaSeq 6000 S1 Reagent Kit (200 cycles)
illumina 20012865 NovaSeq 6000 S1 Reagent Kit (100 cycles)
illumina 20012866 NovaSeq 6000 S4 Reagent Kit (300 cycles)
illumina 20013012 Infinium® ShrimpLD-24 v1.0 BeadChip Kit (48 samples)
illumina 20013013 Infinium® ShrimpLD-24 v1.0 BeadChip Kit (288 samples)
illumina 20013014 Infinium® ShrimpLD-24 v1.0 BeadChip Kit (1152 samples)
illumina 20014015 NovaSeq Library Tubes Accessory Pack (24 tubes)
illumina 20014279 SureCell™ Whole Transcriptome Analysis 3' Library Prep Kit (2 Cartridges Kit)
illumina 20014280 SureCell™ Whole Transcriptome Analysis 3' Library Prep Kit (6 Cartridges Kit)
illumina 20015238 Infinium PsychArray-24 v1.2 Kit (48 samples)
illumina 20015239 Infinium PsychArray-24 v1.2 Kit (288 samples)
illumina 20015240 Infinium PsychArray-24 v1.2 Kit (1152 samples)
illumina 20015246 Infinium Exome-24 v1.1 Kit (48 samples)
illumina 20015247 Infinium Exome-24 v1.1 Kit (288 samples)
illumina 20015248 Infinium Exome-24 v1.1 Kit (1152 samples)
illumina 20015254 Infinium Core-24 v1.1 Kit (48 Samples)
illumina 20015255 Infinium Core-24 v1.1 Kit (288 samples)
illumina 20015256 Infinium Core-24 v1.1 Kit (1152 samples)
illumina 20015262 Infinium CoreExome-24 v1.2 Kit (48 Samples)
illumina 20015263 Infinium CoreExome-24 v1.2 Kit (288 samples)
illumina 20015264 Infinium CoreExome-24 v1.2 Kit (1152 samples)
illumina 20015526 Infinium XT ST Upgrade Kit (Up to 12 BeadChip Batches)
illumina 20015949 TruSeq DNA CD Indexes (96 Indexes, 96 Samples)
illumina 20015960 TruSeq DNA Single Indexes Set A (12 Indexes, 24 Samples)
illumina 20015961 TruSeq DNA Single Indexes Set B (12 Indexes, 24 Samples)
illumina 20015962 TruSeq DNA PCR-Free Low Throughput Library Prep Kit (24 samples)
illumina 20015963 TruSeq DNA PCR-Free High Throughput Library Prep Kit (96 samples)
illumina 20015964 TruSeq Nano DNA Low Throughput Library Prep Kit (24 samples)
illumina 20015965 TruSeq Nano DNA High Throughput Library Prep Kit (96 samples)
illumina 20016098 NovaSeq® 6000 Operational Qualification
illumina 20016100 NovaSeq® 6000 Installation and Operational Qualification
illumina 20016317 Infinium Asian Screening Array-24 v1.0 Kit (48 samples)
illumina 20016318 Infinium Asian Screening Array-24 v1.0 Kit (288 samples)
illumina 20016319 Infinium Asian Screening Array-24 v1.0 Kit (1152 samples)
illumina 20016332 NovaSeq® 6000 Performance Qualification
illumina 20018621 TruSight Tumor 170 Kit, For Use with NextSeq plus Watson for Genomics
illumina 20018622 TruSight Tumor 170 Kit plus Watson for Genomics
illumina 20018679 TruSeq Bovine Parentage Sequencing Panel for MiniSeq
illumina 20018704 Nextera DNA Flex Library Prep (24 Samples)
illumina 20018705 Nextera DNA Flex Library Prep (96 Samples)
illumina 20018706 Flex Lysis Reagent Kit
illumina 20018707 Nextera™ DNA CD Indexes (24 Indexes, 24 Samples)
illumina 20018708 Nextera™ DNA CD Indexes (96 Indexes, 96 Samples)
illumina 20019101 AmpliSeq™ Library PLUS (24 Reactions) for Illumina®
illumina 20019102 AmpliSeq™ Library PLUS (96 Reactions) for Illumina®
illumina 20019103 AmpliSeq™ Library PLUS (384 Reactions) for Illumina®
illumina 20019105 AmpliSeq™ CD Indexes Set A for Illumina® (96 Indexes, 96 Samples)
illumina 20019108 Ampliseq™ CD Indexes Large Volume for Illumina® (96 Indexes, 96 Samples)
illumina 20019109 AmpliSeq™ Comprehensive Panel v3 for Illumina®
illumina 20019160 AmpliSeq™ Comprehensive Cancer Panel for Illumina®
illumina 20019161 AmpliSeq™ Cancer HotSpot Panel v2 for Illumina®
illumina 20019164 AmpliSeq™ Focus Panel for Illumina®
illumina 20019166 AmpliSeq™ Exome Panel for Illumina®
illumina 20019168 AmpliSeq™ BRCA Panel for Illumina®
illumina 20019169 AmpliSeq™ Immune Response Panel for Illumina®
illumina 20019170 AmpliSeq™ Transcriptome Human Gene Expression Panel for Illumina®
illumina 20019792 TruSeq RNA CD Index Plate (96 Indexes, 96 Samples)
illumina 20020181 TruSeq® DNA Library Prep for Enrichment (24 Samples)
illumina 20020182 TruSeq® DNA Library Prep for Enrichment (96 Samples)
illumina 20020183 Exome Panel (45Mb)
illumina 20020187 Nextera™ DNA Library Prep for Enrichment (24 Samples)
illumina 20020188 Nextera™ DNA Library Prep for Enrichment (96 Samples)
illumina 20020189 TruSeq® RNA Library Prep for Enrichment (48 Samples)
illumina 20020490 TruSeq® RNA Enrichment (12 enrichments)
illumina 20020492 TruSeq RNA Single Indexes Set A (12 Indexes, 48 Samples)
illumina 20020493 TruSeq RNA Single Indexes Set B (12 Indexes, 48 Samples)
illumina 20020590 IDT for Illumina – TruSeq DNA UD Indexes (24 Indexes, 96 Samples)
illumina 20020591 IDT for Illumina – TruSeq RNA UD Indexes (24 Indexes, 96 Samples)
illumina 20020594 TruSeq® Stranded mRNA Library Prep (48 Samples)
illumina 20020595 TruSeq Stranded mRNA Library Prep (96 Samples)
illumina 20020596 TruSeq® Stranded Total RNA Library Prep Human/Mouse/Rat (48 Samples)
illumina 20020597 TruSeq® Stranded Total RNA Library Prep Human/Mouse/Rat (96 Samples)
illumina 20020598 TruSeq Stranded Total RNA Library Prep Gold (48 Samples)
illumina 20020599 TruSeq® Stranded Total RNA Library Prep Gold (96 Samples)
illumina 20020610 TruSeq® Stranded Total RNA Library Prep Plant (48 Samples)
illumina 20020611 TruSeq® Stranded Total RNA Library Prep Plant (96 Samples)
illumina 20020612 TruSeq® Stranded Total RNA Library Prep Globin (48 Samples)
illumina 20020613 TruSeq® Stranded Total RNA Library Prep Globin (96 Samples)
illumina 20020614 TruSeq Exome Kit (24 Samples)
illumina 20020615 TruSeq® Exome Kit (96 Samples)
illumina 20020616 Nextera™ Exome Kit (24 Samples)
illumina 20020617 Nextera™ Exome Kit (96 Samples)
illumina 20021533 iSeq 100 i1 Reagent
illumina 20021534 iSeq 100 i1 Reagent 4 pack
illumina 20021663 NovaSeq Xp Flow Cell Dock
illumina 20021664 NovaSeq XP 2-Lane Kit
illumina 20021665 NovaSeq Xp 4-Lane Kit
illumina 20021666 NovaSeq™ Xp 2-Lane Manifold Pack
illumina 20021667 NovaSeq™ Xp 4-Lane Manifold Pack
illumina 20022370 IDT for Illumina – TruSeq DNA UD Indexes (96 Indexes, 96 Samples)
illumina 20022371 IDT for Illumina – TruSeq RNA UD Indexes (96 Indexes, 96 Samples)
illumina 20022654 Ampliseq™ cDNA Synthesis for Illumina®
illumina 20023394 TruSight cfDNA UMI for HiSeq 2500 (48 Samples)
illumina 20023395 TruSight cfDNA UMI for HiSeq 4000 (48 Samples)
illumina 20023396 TruSight cfDNA UMI for NovaSeq S2 (48 Samples)
illumina 20023611 iSeq 100 Installation and Operational Qualification
illumina 20023612 iSeq 100 Installation, Operational, and Performance Qualification
illumina 20024144 Illumina® Free Adapter Blocking Reagent (12 reactions)
illumina 20024145 Illumina® Free Adapter Blocking Reagent (48 reactions)
illumina 20024444 Infinium Global Screening-24 v2.0 Kit (48 samples)
illumina 20024445 Infinium Global Screening-24 v2.0 Kit (288 samples)
illumina 20024446 Infinium Global Screening-24 v2.0 Kit (1152 samples)
illumina 20024566 Infinium Core-24 v1.2 Kit (48 Samples)
illumina 20024567 Infinium Core-24 v1.2 Kit (288 samples)
illumina 20024568 Infinium Core-24 v1.2 Kit (1152 samples)
illumina 20024586 TruSight Oncology UMI Reagents (16 indexes, 48 samples)
illumina 20024631 Infinium OmniExpress-24 v1.3 Kit (48 Samples)
illumina 20024632 Infinium OmniExpress-24 v1.3 Kit (288 Samples)
illumina 20024633 Infinium OmniExpress-24 v1.3 Kit (1152 Samples)
illumina 20024662 Infinium CoreExome-24 v1.3 Kit (48 Samples)
illumina 20024663 Infinium CoreExome-24 v1.3 Kit (288 samples)
illumina 20024664 Infinium CoreExome-24 v1.3 Kit (1152 samples)
illumina 20024907 NextSeq 500/550 High Output Kit v2.5 (150 Cycles)
illumina 20025872 NextSeq 550 Dx Performance Qualification (PQ)
illumina 20025873 MiSeq Dx Performance Qualification (PQ)
illumina 20025874 AmpliSeq™ for Illumina®, Sequencing Service
illumina 20025875 Nextera Rapid Capture Custom Enrichment, Custom Sequencing Service
illumina 20025876 Nextera DNA Flex, Custom Sequencing Service
illumina 20025877 Titanium, Custom Sequencing Service
illumina 15033616R REFURB,ASSY,MiSeq2
illumina A1-99-101 Teflon-coated replacement probes for Tecan Robot (1)
illumina A1-99-102 Tip Depth Gauge
illumina A1-99-104 Infinium Te-Flow Male Connector
illumina A1-99-105 Infinium Te-Flow Rack
illumina A1-99-107 Infinium Te-Flow Tubing
illumina A1-99-109 Infinium Te-Flow Thermometer Assembly
illumina BB1206 Scriptseq Complete (Bacteria) with Ribo-Zero Bacteria rRNA Removal (6 reactions)
illumina BB1224 ScriptSeq Complete Kit (Bacteria) 24 reactions
illumina BD-220-1001 Block E1 Buffer - Large Volume Bottle
illumina BD-60-402 Infinium Hybridization Chamber (1)
illumina BD-60-403 Replacement Infinium Hybridization Chamber Gasket (1)
illumina BD-60-450 Infinium BeadChip Wash Rack (1)
illumina BD-60-460 Infinium BeadChip Glass Tray (1)
illumina BD-60-500 Infinium BeadChip Boxes (10)
illumina BD-60-601 Infinium MIDI Heatblock Insert
illumina BEP1206 ScriptSeq Complete Gold Kit (Epidemiology) 6 reactions
illumina BEP1224 ScriptSeq Complete Gold Kit (Epidemiology) 24 reactions
illumina BG1206 ScriptSeq Complete Gold Kit (H/M/R) 6 reactions
illumina BG1224 ScriptSeq Complete Gold Kit (H/M/R) 24 reactions
illumina BGGB1306 ScriptSeq Complete Gold Kit (Blood) 6 reactions
illumina BGGB1324 ScriptSeq Complete Gold Kit (Blood) 24 reactions
illumina BGY1306 ScriptSeq Complete Gold Kit (Yeast) 6 reactions
illumina BGY1324 ScriptSeq Complete Gold Kit (Yeast) 24 reactions
illumina BHMR1205 ScriptSeq Complete Kit (H/M/R) 6 reactions
illumina BHMR1224 ScriptSeq Complete Kit (H/M/R) 24 reactions
illumina BPL1205 ScriptSeq Complete Kit (Plant Leaf) 6 reactions
illumina BPL1224 ScriptSeq Complete Kit (Plant Leaf) 24 reactions
illumina BSR1206 ScriptSeq Complete Kit (Plant Seed/Root) 6 reactions
illumina CT-403-2001 HiSeq Rapid Duo cBot Sample Loading Kit
illumina CT-901-2002 Genomic Sequencing Primer Kit (up to 10 lanes)
illumina DX-102-1001 MiSeqDx Cystic Fibrosis Clinical Sequencing Assay (6 runs, 48 samples)
illumina DX-102-1004 MiSeqDx Cystic Fibrosis 139-Variant Assay (2 runs, 96 samples)
illumina DX-103-1001 MiSeqDx Universal Kit (2 runs, up to 96 samples)
illumina DX-410-1001 MiSeqDx™ System
illumina EC-200-1002 Eco™ Plates (40 plates)
illumina EC-200-1003 Eco™ Adhesive Seals (40 seals)
illumina EC-800-1001 Spare, Cable, H1, Power Entry
illumina EC-800-1006 Spare, Power Supply, Main 350W, 24V
illumina EC-800-1011 Spare, Power Supply, M2, ATX-HV, 6-32VIN, 140W
illumina EC-800-1013 Spare, Assy, PCBA, MCU, Programmed
illumina EGIDX81312 TruSeq DNA Methylation Index PCR Primers (10 reactions, 12 indexes)
illumina EGMK81312 TruSeq DNA Methylation Kit (12 reactions)
illumina EGMK91324 TruSeq DNA Methylation Kit (24 reactions)
illumina EGMK91396 TruSeq DNA Methylation Kit (96 reactions)
illumina FC-110-3001 PhiX Control v3
illumina FC-110-3002 NextSeq™ PhiX Control Kit
illumina FC-121-0202 TruSight Cancer
illumina FC-121-0205 TruSight Inherited Disease Sequencing Panel (48 samples)
illumina FC-121-1003 TruSeq Dual Index Sequencing Primer Box, Single-Read
illumina FC-121-1011 Nextera Index Kit (24 indexes, 96 samples)
illumina FC-121-1012 Nextera Index Kit (96 indexes, 384 samples)
illumina FC-121-1030 Nextera DNA Library Prep Kit (24 samples)
illumina FC-121-1031 Nextera DNA Library Prep Kit (96 samples)
illumina FC-121-3001 TruSeq DNA PCR-Free LT Library Preparation Kit - Set A (12 Set A index tubes, 24 samples)
illumina FC-121-3002 TruSeq DNA PCR-Free LT Library Preparation Kit - Set B (12 Set B index tubes, 24 samples)
illumina FC-121-3003 TruSeq DNA PCR-Free HT Library Preparation Kit (96 indexes in plate format, 96 samples)
illumina FC-121-4001 TruSeq Nano DNA LT Library Preparation Kit - Set A (12 Set A index tubes, 24 samples)
illumina FC-121-4002 TruSeq Nano DNA LT Library Preparation Kit - Set B (12 Set B index tubes, 24 samples)
illumina FC-121-4003 TruSeq Nano DNA HT Library Preparation Kit (96 indexes in plate format, 96 samples)
illumina FC-121-9999 TruSeq FFPE DNA Library Prep QC Kit (24 samples)
illumina FC-123-1203 TruSight™ Enrichment Kit (24 Indices - 48 Samples)
illumina FC-123-1205 TruSight™ Enrichment Kit (24 Indices - 96 Samples)
illumina FC-126-1001 TruSeq Synthetic Long-Read DNA Library Prep Kit (4 samples)
illumina FC-126-1002 TruSeq Synthetic Long-Read DNA Barcode Kit (1 barcode plate)
illumina FC-126-1003 TruSeq Synthetic Long-Read DNA Barcode Kit (4 barcode plates)
illumina FC-126-1004 TruSeq Synthetic Long-Read DNA Accessory Kit
illumina FC-130-1003 TruSeq Custom Amplicon Index Kit (96 indexes, 384 samples)
illumina FC-130-1005 TruSeq Index Plate Fixture Kit (2 fixtures)
illumina FC-130-1006 TruSeq Custom Amplicon Filter Plate (1 plate)
illumina FC-130-1007 TruSeq Index Plate Fixture & Collar Kit (2 each)
illumina FC-130-1008 TruSeq Amplicon - Cancer Panel (96 samples)
illumina FC-130-1010 TruSight Myeloid Sequencing Panel (96 samples)
illumina FC-130-2001 TruSight Tumor 26
illumina FC-131-1001 Nextera XT Index Kit (24 indexes, 96 samples)
illumina FC-131-1002 Nextera XT Index Kit (96 indexes, 384 samples)
illumina FC-131-1024 Nextera XT DNA Library Preparation Kit (24 samples)
illumina FC-131-1096 Nextera XT DNA Library Preparation Kit (96 samples)
illumina FC-131-2001 Nextera XT Index Kit v2 Set A (96 indexes, 384 samples)
illumina FC-131-2002 Nextera XT Index Kit v2 Set B (96 indexes, 384 samples)
illumina FC-131-2003 Nextera XT Index Kit v2 Set C (96 indexes, 384 samples)
illumina FC-131-2004 Nextera XT Index Kit v2 Set D (96 indexes, 384 samples)
illumina FC-132-1001 Nextera Mate Pair Library Prep Kit (12 indexes, 48 gel-free samples or 12 gel-plus samples)
illumina FC-140-1000 Nextera Rapid Capture Exome (8 rxn x 1 plex)
illumina FC-140-1001 Nextera Rapid Capture Exome (2 rxn x 12 plex)
illumina FC-140-1002 Nextera Rapid Capture Exome (4 rxn x 12 plex)
illumina FC-140-1003 Nextera Rapid Capture Exome (8 rxn x 12 plex)
illumina FC-140-1004 Nextera Rapid Capture Expanded Exome (2 rxn x 12 plex)
illumina FC-140-1005 Nextera Rapid Capture Expanded Exome (4 rxn x 12 plex)
illumina FC-140-1006 Nextera Rapid Capture Expanded Exome (8 rxn x 12 plex)
illumina FC-140-1083 Nextera Rapid Capture Exome (8 rxn x 3 plex)
illumina FC-140-1086 Nextera Rapid Capture Exome (8 rxn x 6 plex)
illumina FC-140-1089 Nextera Rapid Capture Exome (8 rxn x 9 plex)
illumina FC-140-1101 TruSight Rapid Capture (1 index, 8 samples, 8 enrichments)
illumina FC-140-1102 TruSight Rapid Capture (2 indexes, 8 samples, 4 enrichments)
illumina FC-140-1103 TruSight Rapid Capture (4 indexes, 16 samples, 4 enrichments)
illumina FC-140-1104 TruSight Rapid Capture(24 indexes, 48 samples, 4 enrichments)
illumina FC-140-1105 TruSight Rapid Capture (24 indexes, 96 samples, 8 enrichments)
illumina FC-140-1106 TruSight Rapid Capture (96 indexes, 288 samples, 24 enrichments)
illumina FC-141-1006 TruSight One Sequencing Kit (9 samples)
illumina FC-141-1007 TruSight One Sequencing Panel (36 samples)
illumina FC-141-1010 TruSight Cardio Sequencing Kit for MiSeq and MiSeqDx (12 indexes, 12 samples, 1 enrichment)
illumina FC-141-1011 TruSight Cardio Sequencing Kit for NextSeq (48 indexes, 48 samples, 4 enrichments)
illumina FC-141-2007 TruSight One Expanded Sequencing Panel (36 samples)
illumina FC-142-1001 TruSight® HLA Sequencing Panel (24 samples)
illumina FC-144-1000 TruSeq Rapid Exome Library Prep Kit (8 samples)
illumina FC-144-1001 TruSeq Rapid Exome Library Prep Kit (24 samples)
illumina FC-144-1002 TruSeq Rapid Exome Library Prep Kit (48 samples)
illumina FC-144-1003 TruSeq Rapid Exome Library Prep Kit (72 samples)
illumina FC-144-1004 TruSeq Rapid Exome Library Prep Kit (96 samples)
illumina FC-150-1001 TruSeq Exome Library Prep Kit (24 samples)
illumina FC-150-1002 TruSeq Exome Library Prep Kit (48 samples)
illumina FC-150-1003 TruSeq Exome Library Prep Kit (72 samples)
illumina FC-150-1004 TruSeq Exome Library Prep Kit (96 samples)
illumina FC-151-1002 TruSeq-Methyl Capture EPIC Library Prep Kit (12 samples, 4 indexes)
illumina FC-151-1003 TruSeq-Methyl Capture EPIC Library Prep Kit (48 samples, 12 indexes)
illumina FC-401-3001 TruSeq SBS Kit v3-HS (200 cycles)
illumina FC-401-3002 TruSeq SBS Kit v3-HS (50 cycles)
illumina FC-401-4002 HiSeq SBS Kit V4 50 cycle kit
illumina FC-401-4003 HiSeq SBS Kit V4 250 cycle kit
illumina FC-402-4021 HiSeq Rapid SBS Kit v2 (200 cycles)
illumina FC-402-4022 HiSeq Rapid SBS Kit v2 (50 cycles)
illumina FC-402-4023 HiSeq Rapid SBS Kit v2 (500 cycles)
illumina FC-404-2001 NextSeq 500/550 Mid Output v2 kit (150 cycles)
illumina FC-404-2002 NextSeq 500/550 High Output v2 kit (150 cycles)
illumina FC-404-2003 NextSeq 500/550 Mid Output v2 kit (300 cycles)
illumina FC-404-2004 NextSeq 500/550 High Output v2 kit (300 cycles)
illumina FC-404-2005 NextSeq 500/550 High Output v2 kit (75 cycles)
illumina FC-410-1001 HiSeq 3000/4000 SBS Kit (50 cycles)
illumina FC-410-1002 HiSeq 3000/4000 SBS Kit (150 cycles)
illumina FC-410-1003 HiSeq 3000/4000 SBS Kit (300 cycles)
illumina FC-420-1001 MiniSeq High Output Reagent Kit (75-cycles)
illumina FC-420-1002 MiniSeq High Output Reagent Kit (150-cycles)
illumina FC-420-1003 MiniSeq High OutputReagent Kit (300-cycles)
illumina FC-420-1004 MiniSeq Mid Output Kit (300-cycles)
illumina FC-451-1001 ForenSeq Index Adapter Fixture
illumina FC-501-2501 HiSeq X Ten Reagent Kit v2.5
illumina FC-501-2521 HiSeq X Ten Reagent Kit v2.5 - 10 pack
illumina FC-502-2501 HiSeq X Five Reagent Kit v2.5
illumina FC-502-2521 HiSeq X Five Reagent Kit v2.5 - 10 pack
illumina FC-901-1001 Hybridization Manifold (0801-1320)
illumina FC-901-1002 Amplification Manifold (0801-1321)
illumina FC-901-1003 Cs, Bridge Manifold
illumina GD-300-2001 TruSeq SR Cluster Kit v2 - cBot - GA
illumina GD-304-2001 TruSeq cBot Multi-Primer Re-hybridization Kit v2
illumina GD-305-2001 HiSeq X™ cBot™ Multi-Primer Rehybridization Kit v2
illumina GD-310-1001 HiSeq® 3000/4000 cBot™ Multi-Primer Rehybridization Kit
illumina GD-401-3001 TruSeq SR Cluster Kit v3-cBot-HS
illumina GD-401-4001 HiSeq SR Cluster Kit v4 cBot
illumina GD-402-4002 HiSeq SR Rapid Cluster Kit v2
illumina GD-403-4001 HiSeq® Multi-Primer Rehybridization Kit v4
illumina GD-404-1001 HiSeq Rapid Rehybridization Kit
illumina GD-410-1001 HiSeq 3000/4000 SR Cluster Kit
illumina GZG1206 Globin-Zero Gold rRNA Removal Kit 6 reactions
illumina GZG1224 Globin-Zero Gold rRNA Removal Kit 24 reactions
illumina IP-202-1012 TruSeq ChIP Library Preparation Kit - Set A (12 indexes, 48 rxns)
illumina IP-202-1024 TruSeq ChIP Sample Preparation Kit - Set B (12 indexes, 48 rxns)
illumina MRZB12424 Ribo-Zero rRNA Removal Kit (Bacteria) 24 reactions
illumina MRZE706 Ribo-Zero Gold rRNA Removal Kit (Epidemiology) 6 reactions
illumina MRZE724 rRNA Removal Kit (Epidemiology) 24 reactions
illumina MRZG12324 Ribo-Zero Gold rRNA Removal Kit (H/M/R) (24 reactions)
illumina MRZG126 Ribo-Zero Gold rRNA Removal Kit (H/M/R) (6 reactions)
illumina MRZGN126 Ribo-Zero rRNA Removal Kit (Gram-Negative Bacteria) 6 reactions
illumina MRZGP126 Ribo-Zero rRNA Removal Kit (Gram-Positive Bacteria) 6 reactions
illumina MRZH11124 Ribo-Zero rRNA Removal Kit (H/M/R) 24 reactions
illumina MRZH116 Ribo-Zero rRNA Removal Kit (H/M/R) 6 reactions
illumina MRZMB126 Ribo-Zero rRNA Removal Kit (Bacteria) 6 reactions
illumina MRZPL116 Ribo-Zero rRNA Removal Kit (Plant Leaf) 6 reactions
illumina MRZPL1224 Ribo-Zero rRNA Removal Kit (Plant Leaf) 24 reactions
illumina MRZSR116 Ribo-Zero rRNA Removal Kit (Plant Seed/Root) 6 reactions
illumina MRZY1306 Ribo-Zero Gold rRNA Removal Kit (Yeast) 6 reactions
illumina MRZY1324 Ribo-Zero Gold rRNA Removal Kit (Yeast) 24 reactions
illumina MS-102-2001 MiSeq Reagent Kit v2 (50-cycles)
illumina MS-102-2002 MiSeq Reagent Kit v2 (300-cycles)
illumina MS-102-2003 MiSeq Reagent Kit v2 (500-cycles)
illumina MS-102-2021 20-pack MiSeq Reagent Kit v2 (50-cycles)
illumina MS-102-2022 20-pack MiSeq Reagent Kit v2 (300-cycles)
illumina MS-102-2023 20-pack MiSeq Reagent Kit v2 (500-cycles)
illumina MS-102-3001 MiSeq Reagent Kit v3 (150-cycle)
illumina MS-102-3003 MiSeq Reagent Kit v3 (600-cycle)
illumina MS-102-9999 MiSeq® Disposable Wash Tubes
illumina MS-103-1001 MiSeq Reagent Nano Kit v2 (300-cycles)
illumina MS-103-1002 MiSeq Reagent Micro Kit v2 (300-cycles)
illumina MS-103-1003 MiSeq Reagent Nano Kit v2 (500-cycles)
illumina OP-101-1001 TruSight Tumor 15 MiSeq Kit
illumina OP-101-1002 TruSight Tumor 15 (Library Prep Only)
illumina OP-101-1003 TruSight Tumor 170 Kit, For Use with NextSeq (24 Samples)
illumina OP-101-1004 TruSight Tumor 170 Kit (24 Samples)
illumina PE-121-1003 TruSeq Dual Index Sequencing Primer Box, Paired-End
illumina PE-401-3001 TruSeq PE Cluster Kit v3-cBot-HS
illumina PE-401-4001 HiSeq PE Cluster Kit V4 - cBot
illumina PE-402-4002 HiSeq PE Rapid Cluster Kit v2
illumina PE-410-1001 HiSeq 3000/4000 PE Cluster Kit
illumina PR-40-415101-00 SurePlex DNA Amplification System (50 reactions)
illumina RH-101-1001 VeriSeq PGS Kit (96 samples)
illumina RH-102-1001 MiSeq Reagent Kit v3 - PGS (24 samples)
illumina RH-103-1001 HumanKaryomap-12 DNA Analysis Kit (24 samples)
illumina RS-122-2001 TruSeq RNA Library Preparation Kit v2, Set A (48 samples, 12 indexes)
illumina RS-122-2002 TruSeq RNA Library Preparation Kit v2, Set B (48 samples, 12 indexes)
illumina RS-122-2101 TruSeq Stranded mRNA Library Preparation Kit Set A (48 samples, 12 indexes)
illumina RS-122-2102 TruSeq Stranded mRNA Library Preparation Kit Set B (48 samples, 12 indexes)
illumina RS-122-2103 TruSeq Stranded mRNA Library Prep Kit High Throughput (96 samples, 96 indexes)
illumina RS-122-2201 TruSeq Stranded Total RNA Library Prep Kit with Ribo-Zero Human/Mouse/Rat Set A (48 samples, 12 indexes)
illumina RS-122-2202 TruSeq Stranded Total RNA Library Prep Kit with Ribo-Zero Human/Mouse/Rat Set B (48 samples, 12 indexes)
illumina RS-122-2203 TruSeq Stranded Total RNA Library Prep Kit with Ribo-Zero Human/Mouse/Rat High Throughput (96 samples, 96 indexes)
illumina RS-122-2301 TruSeq Stranded Total RNA Library Prep Kit with Ribo-Zero Gold Set A (48 samples, 12 indexes)
illumina RS-122-2302 TruSeq Stranded Total RNA Library Prep Kit with Ribo-Zero Gold Set B (48 samples, 12 indexes)
illumina RS-122-2303 TruSeq Stranded Total RNA Library Prep Kit with Ribo-Zero Gold High Throughput (96 samples, 96 indexes)
illumina RS-122-2401 TruSeq Stranded Total RNA Kit with Ribo-Zero Plant, Set A (48 samples, 12 indexes)
illumina RS-122-2402 TruSeq Stranded Total RNA Kit with Ribo-Zero Plant, Set B (48 samples, 12 indexes)
illumina RS-122-2403 TruSeq Stranded Total RNA Kit with Ribo-Zero Plant, High Throughput (96 samples, 96 indexes)
illumina RS-122-2501 TruSeq Stranded Total RNA Library Prep Kit with Ribo-Zero Globin Set A (48 samples, 12 indexes)
illumina RS-122-2502 TruSeq Stranded Total RNA Library Prep Kit with Ribo-Zero Globin Set B (48 samples, 12 indexes)
illumina RS-122-2503 TruSeq Stranded Total RNA Library Prep Kit with Ribo-Zero Globin High Throughput (96 samples, 96 indexes)
illumina RS-200-0012 TruSeq Small RNA Library Prep Kit -Set A (24 rxns) (Set A: indexes 1-12)
illumina RS-200-0024 TruSeq Small RNA Library Prep Kit -Set B (24 rxns) (Set B: indexes 13-24)
illumina RS-200-0036 TruSeq Small RNA Library Prep Kit -Set C (24 rxns) (Set C: indexes 25-36)
illumina RS-200-0048 TruSeq Small RNA Library Prep Kit -Set D (24 rxns) (Set D: indices 37-48)
illumina RS-301-2001 TruSeq RNA Access Library Prep Kit - Set A (12 indexes, 48 samples)
illumina RS-301-2002 TruSeq RNA Access Library Prep Kit - Set B (12 indexes, 48 samples)
illumina RS-303-1002 TruSight RNA Pan-Cancer Panel Set A
illumina RS-303-1003 TruSight RNA Pan-Cancer Panel Set B
illumina RS-304-1002 TruSight RNA Fusion Panel Set A (48 samples)
illumina RS-304-1003 TruSight RNA Fusion Panel Set B (48 samples)
illumina RSBC10948 ScriptSeq Index PCR Primers (Set 1)
illumina RT-401-1001 TruSeq Targeted RNA Index Kit (48 indexes, 48 samples)
illumina RT-402-1001 TruSeq Targeted RNA Index Kit A (96 indexes, 384 samples)
illumina RT-402-1002 TruSeq Targeted RNA Index Kit B (96 indexes, 384 samples)
illumina RT-402-1003 TruSeq Targeted RNA Index Kit C (96 indexes, 384 samples)
illumina RT-402-1004 TruSeq Targeted RNA Index Kit D (96 indexes, 384 samples)
illumina SC-16-350 Isolation Table Set
illumina SC-30-401 Infinium Automation Kit- 8 Tip Tecan Non-LIMS (110V)
illumina SC-30-402 Infinium Automation Kit- 8 Tip Tecan Non-LIMS (220V)
illumina SC-30-403 Infinium Automation Kit- 8 Tip Tecan LIMS Ready (110V)
illumina SC-30-404 Infinium Automation Kit- 8 Tip Tecan LIMS Ready (220V)
illumina SC-60-503 SciGene TruTemp Heating System (110V)
illumina SC-60-504 SciGene TruTemp Heating System (220V)
illumina SE-104-1009 Infinium HD Ultra-24 Robotic Tip Guide D
illumina SE-104-1011 Infinium HD Super-8 Robotic Tip Guide E
illumina SE-104-1013 Infinium LCG Robotic Tip Guide F
illumina SE-104-1015 Infinium HTS-24 Robotic Tip Guide G
illumina SE-202-1001 Illumina® LIMS Base Module Server Upgrade (110V)
illumina SE-202-1002 Illumina® LIMS Base Module Server Upgrade (220V)
illumina SP-101-1002 cBot™ Operational Qualification
illumina SP-101-1006 cBot™ Installation and Operational Qualification
illumina SP-101-2006 cBot™ 2 Installation and Operational Qualification
illumina SP-102-1102 HiSeq X™ Operational Qualification
illumina SP-102-1103 HiSeq X™ Performance Qualification
illumina SP-102-1106 HiSeq X™ Installation and Operational Qualification
illumina SP-102-2501 HiSeq® 2500 Installation Qualification
illumina SP-102-2502 HiSeq® 2500 Operational Qualification
illumina SP-102-2503 HiSeq® 2500 Performance Qualification
illumina SP-102-2506 HiSeq® 2500 Installation and Operational Qualification
illumina SP-102-3002 HiSeq 3000 Operational Qualification
illumina SP-102-3003 HiSeq® 3000 Performance Qualification
illumina SP-102-3006 HiSeq® 3000 Installation and Operational Qualification
illumina SP-102-4002 HiSeq 4000 Operational Qualification
illumina SP-102-4003 HiSeq® 4000 Performance Qualification
illumina SP-102-4006 HiSeq® 4000 Installation and Operational Qualification
illumina SP-103-1001 MiSeq® Installation Qualification
illumina SP-103-1002 MiSeq® Operational Qualification
illumina SP-103-1003 MiSeq® Performance Qualification
illumina SP-103-1006 MiSeq® Installation and Operational Qualification
illumina SP-104-1002 NextSeq® 500 Operational Qualification
illumina SP-104-1006 NextSeq® 500 Installation and Operational Qualification
illumina SP-104-5503 NextSeq® 550 Performance Qualification
illumina SP-104-5506 NextSeq® 550 Installation and Operational Qualification
illumina SP-106-1002 MiSeq FGx™ Operational Qualification
illumina SP-106-1003 MiSeq FGx™ Performance Qualification
illumina SP-201-1002 NeoPrep™ Operational Qualification
illumina SP-201-1006 NeoPrep™ Installation and Operational Qualification
illumina SP-301-1002 iScan® Operational Qualification
illumina SP-301-1006 iScan® Installation and Operational Qualification
illumina SP-503-1002 MiSeqDx™ Operational Qualification
illumina SP-503-1006 MiSeqDx® Installation and Operational Qualification
illumina SR-1000-1 SuperRox Reference Dye
illumina SSIP1202 ScriptSeq Index PCR Primers (Set 2)
illumina SSIP1203 ScriptSeq Index PCR Primers (Set 3)
illumina SSIP1204 ScriptSeq Index PCR Primers (Set 4)
illumina SSIP1234 ScriptSeq Index PCR Primers (Sets 1-4)
illumina SSV21106 ScriptSeq RNA-Seq Library Preparation Kit 6 reactions
illumina SSV21124 ScriptSeq RNA-Seq Library Preparation Kit 24 reactions
illumina SW-361-1001 BaseSpace® Correlation Engine - Small Academic Lab License
illumina SW-361-1002 BaseSpace® Correlation Engine - Large Academic Lab License
illumina SY-312-2001 cBot 2
illumina SY-401-2015 cBot Manifold for HiSeq
illumina SY-410-1003 MiSeq® System
illumina SY-410-1101 Certified Pre-Owned MiSeq System
illumina SY-411-1001 MiSeq FGx™ Sequencing System
illumina SY-411-1002 MiSeq FGx™ Upgrade Kit
illumina SY-415-1001 NextSeq® 500 Sequencing System
illumina SY-415-1002 NextSeq® 550 Sequencing System
illumina SY-415-1003 NextSeq® 500 to NextSeq® 550 Upgrade
illumina SY-420-1001 MiniSeq System
illumina TG-101-3001 TG TruSeq SBS Kit v3 - HS (200-cycles)
illumina TG-101-3002 TG TruSeq SBS Kit v3 - HS (50-cycles)
illumina TG-101-4002 TG HiSeq® SBS Kit v4 (50 cycles)
illumina TG-110-3001 TG PhiX Control Kit v3
illumina TG-141-1005 TG TruSight Inherited Disease Sequencing Panel (48 Samples)
illumina TG-142-1001 TG MiSeq Reagent Nano Kit, v2 (300 cycles)
illumina TG-142-1002 TG MiSeq Reagent Micro Kit v2 (300 cycles)
illumina TG-142-1003 TG MiSeq Reagent Kit, v2 (300 cycles)
illumina TG-142-1013 TG MiSeq Reagent Kit v2 (500 cycles)
illumina TG-142-1022 TG MiSeq® Reagent Kit v2 (300 cycles) - 20 Pack
illumina TG-142-3003 TG MiSeq Reagent Kit v3 (600 cycle)
illumina TG-143-1001 MiSeq FGx Reagent Kit
illumina TG-160-2002 TG NextSeq® 500/550 High Output Kit v2 (150 cycles)
illumina TG-160-2004 TG NextSeq® 500/550 High Output Kit v2 (300 cycles)
illumina TG-160-2005 TG NextSeq® 500/550 High Output Kit v2 (75 cycles)
illumina TG-160-2105 TG NextSeq® 500/550 High Output Kit v1.2 (75 cycles)
illumina TG-190-1001 TG VeriSeq™ NIPT Sample Prep Kit (48 samples)
illumina TG-202-1001 TG TruSeq® Nano DNA LT Sample Prep Kit, Set A (24 Samples)
illumina TG-202-1002 TG TruSeq® Nano DNA LT Sample Prep Kit, Set B (24 Samples)
illumina TG-202-1003 TG TruSeq® Nano DNA HT Sample Preparation Kit (96 Samples)
illumina TG-280-1001 TG Truseq® Nano DNA Accessory Kit
illumina TG-301-3101 TG TruSeq® SR Cluster Kit v1–cBot™ - HS
illumina TG-301-4001 TG HiSeq® SR Cluster Kit v4 - cBot™
illumina TG-401-4001 TG HiSeq® PE Cluster Kit v4 – cBot™
illumina TG-403-2001 TG HiSeq® Rapid PE Cluster Kit v2
illumina TG-403-2002 TG HiSeq® Rapid SR Cluster Kit v2
illumina TG-404-2002 TG HiSeq® Rapid SBS Kit v2 (200 Cycle)
illumina TG-450-1001 ForenSeq DNA Signature Prep Kit
illumina WG-10-201 Infinium BeadChip Expansion Package
illumina WG-10-202 Infinium Teflow Chamber (1)
illumina WG-10-203 Infinium HD Te-Flow Chamber Spacers (box of 500)
illumina WG-10-207 Infinium Staining Rack (1)
illumina WG-10-211 Infinium Water Circulator and Teflow Rack Kit 110V
illumina WG-10-212 Infinium Water Circulator and Teflow Rack Kit 220V
illumina WG-100-1001 Infinium HTS/LCG Te-Flow Chambers
illumina WG-100-1002 Infinium HTS/LCG Te-Flow Chamber Spacers (box 500)
illumina WG-100-2001 Infinium HTS/LCG Te-Flow Glass Kit (8)
illumina WG-100-2002 Infinium HTS/LCG Te-Flow Glass Kit (24)
illumina WG-15-301 Infinium Hybridization Chamber Inserts (8)
illumina WG-15-306 Infinium Accessory Starter Kit - Mid Throughput (110V)
illumina WG-15-308 InfiniumAccessory Starter Kit - High Throughput (110V)
illumina WG-15-310 Infinium Multi-Sample Alignment Fixture (1)
illumina WG-316-1001 Infinium Multi-Ethnic Global-8 v1.0 Kit (16 samples)
illumina WG-316-1002 Infinium Multi-Ethnic Global-8 v1.0 Kit (48 samples)
illumina WG-316-1003 Infinium Multi-Ethnic Global-8 v1.0 Kit (96 samples)
illumina WG-316-1004 Infinium Multi-Ethnic Global-8 v1.0 Kit (384 samples)
illumina WG-317-1001 Infinium MethylationEPIC BeadChip Kit (16 samples)
illumina WG-317-1002 Infinium MethylationEPIC BeadChip Kit (32 samples)
illumina WG-317-1003 Infinium MethylationEPIC BeadChip Kit (96 samples)
illumina WG-320-2101 HumanCytoSNP-12 v2.1 BeadChip Kit (12 samples)
illumina WG-320-2102 HumanCytoSNP-12 v2.1 BeadChip Kit (24 samples)
illumina WG-320-2103 HumanCytoSNP-12 v2.1 BeadChip Kit (48 samples)
illumina WG-320-2104 HumanCytoSNP-12 v2.1 BeadChip Kit (288 samples)
illumina WG-320-2105 HumanCytoSNP-12 v2.1 BeadChip Kit (1152 samples)
illumina WG-321-1001 Infinium FFPE QC Kit (384 reactions)
illumina WG-321-1002 Infinium HD FFPE DNA Restore Kit (24 samples)
illumina WG-321-1003 HumanCytoSNP FFPE-12 v2.1 DNA Analysis BeadChip Kit (24 samples)
illumina WG-321-1004 HumanCytoSNP FFPE-12 v2.1 DNA Analysis BeadChip Kit (48 samples)
illumina WG-322-1101 Infinium CytoSNP-850K v1.1 BeadChip Kit (8 samples)
illumina WG-322-1102 Infinium CytoSNP-850K v1.1 BeadChip Kit (16 samples)
illumina WG-322-1103 Infinium CytoSNP-850K v1.1 BeadChip Kit (48 samples)
illumina WG-322-1104 Infinium CytoSNP-850K v1.1 BeadChip Kit(96 samples)
illumina WG-330-2001 Infinium Core-24 Kit (48 samples)
illumina WG-330-2002 Infinium Core-24 Kit (288 samples)
illumina WG-330-2003 Infinium Core-24 Kit (1152 samples)
illumina WG-331-1101 Infinium CoreExome-24 v1.1 Kit (48 samples)
illumina WG-331-1102 Infinium CoreExome-24 v1.1 Kit (288 samples)
illumina WG-331-1103 Infinium CoreExome-24 v1.1 Kit (1152 samples)
illumina WG-355-1001 Infinium OncoArray-500K BeadChip Kit (48 samples)
illumina WG-355-1002 Infinium OncoArray-500K BeadChip Kit (288 samples)
illumina WG-355-1003 Infinium OncoArray-500K v1.0 BeadChip Kit (1152 samples)
illumina WG-357-1001 Infinium ImmunoArray-24 v2 BeadChip Kit (48 samples)
illumina WG-357-1002 Infinium ImmunoArray-24 v2 BeadChip Kit (288 samples)
illumina WG-357-1003 Infinium ImmunoArray-24 v2 BeadChip Kit (1152 samples)
illumina WG-358-1001 Infinium Exome-24 v1.0 Kit (48 samples)
illumina WG-358-1002 Infinium Exome-24 v1.0 Kit (288 samples)
illumina WG-358-1003 Infinium Exome-24 v1.0 Kit (1152 samples)
illumina WG-410-2001 PorcineSNP60v2 BeadChip (48 samples)
illumina WG-410-2002 PorcineSNP60v2 BeadChip (288 samples)
illumina WG-410-2003 PorcineSNP60v2 BeadChip (1152 samples)
illumina WG-420-1001 OvineSNP50 BeadChip (48 samples)
illumina WG-420-1002 OvineSNP50 BeadChip (288 samples)
illumina WG-420-1003 OvineSNP50 BeadChip (1152 samples)
illumina WG-440-1001 CanineHD BeadChip (48 samples)
illumina WG-440-1002 CanineHD BeadChip (288 samples)
illumina WG-440-1003 CanineHD BeadChip (1152 samples)
illumina WG-450-1002 BovineHD BeadChip (48 samples)
illumina WG-450-1003 BovineHD BeadChip (96 samples)
illumina WG-450-1004 BovineHD BeadChip (384 samples)
illumina WG-451-2001 BovineLD v2.0 BeadChip (48 samples)
illumina WG-451-2002 BovineLD v2.0 BeadChip (288 samples)
illumina WG-451-2003 BovineLD v2.0 BeadChip (1152 samples)
illumina WG-455-1001 MaizeLD BeadChip Kit (48 samples)
illumina WG-455-1002 MaizeLD BeadChip Kit (288 samples)
illumina WG-455-1003 MaizeLD BeadChip Kit (1152 samples)
illumina WG-500-1001 MaizeSNP50 Beadchip (48 samples)
illumina WG-500-1002 MaizeSNP50 BeadChip (288 samples)
illumina WG-500-1003 MaizeSNP50 BeadChip (1152 samples)
Illumina 簇生成和測序試劑 MS-102-3003
產(chǎn)品咨詢